sMrt single, Dual and triple space DC-DC Converters

Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
19-56 Volt input – 35 Watt – Space qualified
Features
Radiation tolerant space dc-dc converter
• Single event effects (SEE) LET performance to
86 MeV cm2/mg
• Total ionizing dose (TID) guaranteed to 100 krad(Si)
RHA level R, per MIL-STD-883 method 1019
-- 50 - 300 rad(Si)/sec dose rate (Condition A)
-- 10 mrad(Si)/sec dose rate (Condition D)
• Built in MIL-STD-461 EMI filter
• Output trim from 51% to 124% of nominal
• Operating temperature -55° to +125°C
• Qualified to MIL-PRF-38534 Class H and K
• Input voltage range 19 to 56 V
• Transient protection 80 V for 120 ms
• Fully isolated, 5 port isolation
• Dual magnetic feedback
• Fixed high frequency switching
• Remote sense
• Inhibit function
• Synchronization input
models
• Indefinite short circuit protection
Output Voltage (V)
• Meets MIL-STD-704A transient standards
description
The Interpoint® SMRT Series™ of dc-dc converters offers up
to 35 watts of power in a radiation tolerant design. The low
profile SMRT converters are manufactured in our fully certified
and qualified MIL-PRF-38534 production facility and packaged
in hermetically sealed steel cases. They are ideal for use in
programs requiring high reliability, small size, and high levels of
radiation hardness assurance.
The SMRT converters are switching regulators which use a
two-phase, phase shifted flyback design with a nominal switching
frequency of 300 kHz. Close regulation is maintained with
advanced constant frequency pulse width modulation design
techniques. The SMRT’s feed-forward compensation and
discontinuous topologies provide high levels (60 dB peak) of
input-to-output ripple rejection.
Crane Aerospace & Electronics
Power Solutions – Interpoint Products
10301 Willows Rd. NE, Redmond, WA 98052
+1.425.882.3100 • [email protected]
www.craneae.com/interpoint
SINGLE
DUAL
TRIPLE
3.3
Vout A 5 V, Vout B 5 V
+3.3 & ±12
5
Vout A 12 V, Vout B 12 V
+3.3 & ±15
8.7
Vout A 15 V, Vout B 15 V
+5 & ±7
12
+5 & ±12
15
+5 & ±15
Two independent feedback loops are used to regulate the dual
and triple outputs, one feedback loop regulates the two-phased
single output. Each set of outputs is electrically isolated from the
other and from the input. This product configuration eliminates
cross regulation effects between output sets.
Configurations:
• Single Output: One dual-phase output
• Dual Output: Two isolated single-phase outputs
• Triple Output: One single-phased output (Main) isolated
from one single-phase dual output (± Auxiliary)
Page 1 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
19-56 Volt input – 35 Watt – Space qualified
Undervoltage Lockout
Screening
The converters have an undervoltage lockout that will allow
power conversion at approximately 17 volts on a rising input
voltage and a conversion shut-down on a falling voltage at
approximately 14.5 volts.
Inhibit Function
The SMRT Series incorporates an inhibit terminal that can be
used to disable internal switching. It is not recommended to tie
the Inhibit pin of an SMRT directly to the Inhibit pin of another
converter as the SMRT Inhibit pin can sink current. When pulling
multiple inhibit signals low, a separate interface is recommended
for each SMRT. The converter is inhibited when the Inhibit pin
is pulled low (0.4 V). In the inhibit mode the inhibit pin current
requirement is less than ~2 mA. The converter resumes normal
operation when an open circuit is applied to the Inhibit pin or the
Inhibit pin is open (unconnected). The open circuit voltage of the
Inhibit pin is 5 to 6 volts. To enable the converter use an open
collector on the Inhibit pin or leave it unconnected.
Synchronization
The Sync Input pin is isolated which allows Sync Return pin to be
tied to the primary side, secondary side, or float with respect to all
inputs and outputs. Input current into this pin is limited by a series
1 k ohm resistance.
Radiation Tolerance
The SMRT dc-dc converters are designed to provide continuous
normal operation through radiation levels associated with space
missions and in tactical and strategic military environments. The
converters will operate normally in radiation environments with
up to 100 krad(Si) total dose. The converter will not exhibit low
dose rate (LDR) effects at 10 mrad(Si)/sec dose rate up to a TID
of 100 krad.
These levels of radiation tolerance make the SMRT converters
suitable for electronics in programs where operation in high
radiation environments is required.
SMRT converters offer the following screening options: Space
Prototype (O), Class H, or Class K. Radiation tolerant to
Radiation Hardness Assurance (RHA) levels of “-” (O), “P” or
“R”, per MIL-PRF-38534. Interpoint model numbers use an “O” in
the RHA designator position to indicate the “-” (dash) Radiation
Hardness Assurance level of MIL-PRF-38534, which is defined as
“no RHA”. See Table 27 and Table 28 for more information.
EMI
The SMRT has a built-in EMI input filter which brings the
conducted emissions into compliance with both methods of
MIL-STD-461, revisions C-CE03 and D-/E-/F-CE102.
Electrostatic Discharge (ESD) Sensitivity
Per MIL-PRF-38534, the SMRT Series converters are rated to
ESD class 3B defined as sensitivity equal to, or greater than,
8000 volts.
Sense
Tight load regulation is maintained via wide bandwidth magnetic
feedback and through the use of remote sense on single output
models and Vout A on dual output models. The sense pin
function allows a remote connection for the voltage regulation
circuit to compensate for voltage drops between the converter
and the point of use.
Note that if the sense pins are connected but the output voltage
pins are not, the converter may be damaged.
The maximum voltage drop from the output to the sense pin is
shown in Table 1 below.
Nominal Output Voltage (V) 1
Max Voltage drop (V)
Max Voltage at converter
(Vmax) 1
3.3 2
0.58
5
1.0
6.0
1.9
10.58
12
2.68
14.68
15
3.36
18.36
Table 1: Maximum Voltage Drop Using Remote Sense
Single and Dual Models only
8.7
2
3.88
Notes for Table 1
1. Do not exceed maximum voltage.
2. The sense pin function for 3.3 and 8.7 is only available on single output
models.
www.craneae.com/interpoint
Page 2 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
19-56 Volt input – 35 Watt – Space qualified
Output Voltage Trim
There are two possible methods for output voltage trim. Trim can
be achieved using the provided trim pin or in some cases the
sense pin. The preferred method is the use of the trim pin. Every
converter in the SMRT family provides a trim pin that allows at
least one output to be adjusted. See Table 3 and Table 4 for
maximum adjust range for each output voltage. The single output
models provide a trim pin and remote sense. The dual output
models allow remote sense on Vout A and have a trim pin on the
Vout B. The triples have a trim pin on the Vout A (main)and a
single trim pin for both Vout B auxiliaries.
Voltage Adjust Feature
Trim Pin (Formulas 1 and 2)
Sense Pin (Formula 3)
For outputs without a trim pin, the output at the converter can be
adjusted up by adding resistance in series with the sense pin.
See Table 2 for a summary of trim features and see below for
details on the trim features. See Formula 1 for trimming down
when using a trim pin, Formula 2 for trimming up when using a
trim pin and Formula 3 when trimming up using Sense A pin on a
dual output model.
NOTE: Do not exceed maximum current rating when trimming
down.
NOTE: Do not exceed maximum power rating when trimming up.
Singles
Duals
Trim and Sense Pin
Triples
Trim B
—
Trim A, Trim B ±
Sense A
—
Table 2: Trim and Sense Voltage Adjust
Output Voltage Trim Details
The output voltage trim pin function is implemented with a
resistor between the trim pin and either the output voltage pin or 1
5
SMRT Single
14
2
13
3
4
1
14
2
the sense pin. Figure 1 and Figure 2 show the connections for
the trim resistor (RTRIM).
13
3
Trim 12
4
11
SMRT Single
5
10
Trim 12
11
10
Sense Return 9
9
8
Sense 8
1
Vout B Return 14
2
1
2
4
5
4
Vout B 13
3
SMRT Dual
13
3
14
5
Trim B 12
SMRT Dual
14
2
8
4
5
8
2
Trim A 12
SMRT Triple
13
3
+Vout B 11
10
4
5
9
SMRT Triple
Trim A 12
11
Vout B Return 10
9
Trim B 8
Trim B 8
Figure 1: Trim Down Diagrams
www.craneae.com/interpoint
Vout A Return 14
1
Vout A 13
3
11
10
9
11
10
9
1
Trim B 12
Figure 2: Trim Up Diagrams
Page 3 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
19-56 Volt input – 35 Watt – Space qualified
Output Voltage Trim Details (continued)
Trim Down using trim pin, all Models
To trim the output voltage lower than the nominal set point,
connect Rtrim as shown in Figure 1. The value of Rtrim is
calculated by the following equation:
Vnom
K
Vmin
% of VNOM
3.3
3500
3.18
96
5 single and triple
4520
4.16
83
5 dual
7040
4.38
88
7
8020
5.47
78
8.7
9040
6.13
70
12
11030
7.05
58
15
12900
7.65
51
Formula 1: Trim Down Using Trim Pin
Rtrim = K
(V
OUT
) / (V
– VMIN
NOM
– VOUT
)
Where:
K = Multiplication constant from Table 3
Vout = Desired output voltage (must be greater than Vmin)
Vmin = Minimum output voltage from Table 3
Vnom = Nominal set point voltage of the converter
NOTE:
Do not exceed maximum current rating when trimming down.
Table 3: Trim Down Constants when Using Trim Pin
Trim up using trim pin, All Models
To trim the output voltage higher than the nominal set point,
connect Rtrim as shown in Figure 2. The value of Rtrim is
calculated by the following equation:
Vnom
K
VmAX
3.3
3000
3.70
112
5 single and triple
3000
6.26
125
Formula 2: Trim Up Using Trim Pin
% of VNOM
5 dual
5280
5.82
116
7
5300
8.27
118
8.7
5300
10.46
120
12
5300
14.69
122
15
5300
18.54
124
Rtrim = K
(V
MAX –
) / (V
VOUT
out –
Vnom )
Where:
K = Multiplication constant from Table 4
Vout = Desired output voltage (must be less than Vmax)
Vmax = Maximum output voltage from Table 4
Vnom = Nominal set point voltage of the converter
NOTE:
Do not exceed maximum power rating when trimming up.
Table 4: Trim Up Constants when Using Trim Pin
Trim up using Sense A Pin on Dual Models Only
Trim Up Vout A
Formula 3: Trim Up Using Sense A Pin
In addition to remote sensing, the Sense A pin may be used to
increase the regulated output voltage at the Vout A pin. This
is accomplished by attaching a resistor (Radjust) between the
Sense A pin (pin 8) and the Vout A pin (pin 11). The value of
Radjust is calculated by the following equation:
Radjust = 240 Vout – Vnom
Vnom
K
VmAX
% of VNOM
5
1
6.00
120
12
0.98
12.98
108
15
1.134
16.13
107.5
(
max –
))
Vout
Where:
Vout = Desired output voltage (must be less than Vmax)
Vnom = Nominal set point voltage of the converter
Vmax = Maximum achievable output voltage
NOTE:
Do not exceed maximum power rating when trimming up.
Table 5: Trim Up Constants when Using Sense Pin on
Output A of Dual Output Models
www.craneae.com/interpoint
) / ( K + (V
Page 4 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
19-56 Volt input – 35 Watt – Space qualified
Prim. Bias
Bias 1
28V
Vin
Bias 1
Prim. Bias
Error Amp / ref /
compensation
Prim. Bias
EMI Filter
Prim. Bias
Trim
OCP
Vout A Rtn.
28V
Feed forward
compensation
Isolation
Feedback
Vout A Rtn.
28V
Phase A
Sync In
Sense
Sense Rtn.
PWM
Vin Rtn.
Vout A
Bias 2
Clock
Sync Rtn.
Phase B
Prim. Bias
Prim. Bias
PWM
Inhibit
Vout A
OCP
5.1V Z
Vout A Rtn.
Isolation
Feedback
Vout A Rtn.
Primary
Secondary
Figure 3: SMRT Single Block Diagram
www.craneae.com/interpoint
Page 5 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
19-56 Volt input – 35 Watt – Space qualified
Prim. Bias
Bias 1
28V
Vin
Bias 1
Prim. Bias
Error Amp / ref /
compensation
Prim. Bias
EMI Filter
Prim. Bias
OCP
Vout A Rtn.
28V
Feed forward
compensation
Isolation
Feedback
Vout A Rtn
28V
Phase A
Sync In
Sense A
Sense A Rtn.
PWM
Vin Rtn.
Vout A
Bias 2
Clock
Sync Rtn.
Phase B
Prim. Bias
Prim. Bias
PWM
Inhibit
Bias 2
OCP
Error Amp / ref /
compensation
5.1V Z
Vout B
Trim B
Vout B Rtn.
Isolation
Feedback
Vout B Rtn.
Primary
Secondary
Figure 4: SMRT Dual Block Diagram
www.craneae.com/interpoint
Page 6 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
19-56 Volt input – 35 Watt – Space qualified
Prim. Bias
Bias 1
28V
Vin
Bias 1
Prim. Bias
Error Amp / ref /
compensation
Prim. Bias
EMI Filter
PWM
Vin Rtn.
Prim. Bias
Trim A
Vout A Rtn.
OCP
28V
Feed forward
compensation
Isolation
Feedback
Vout A Rtn.
28V
Phase A
Sync In
Vout A
Bias 2
Clock
Sync Rtn.
Phase B
Prim. Bias
Prim. Bias
PWM
Inhibit
Bias 2
OCP
Error Amp / ref /
compensation
5.1V Z
Vout B Pos.
Trim B
Vout B Rtn.
Vout B Neg.
Isolation
Feedback
Primary
Vout B Rtn.
Secondary
Figure 5: SMRT Triple Block Diagram
www.craneae.com/interpoint
Page 7 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
19-56 Volt input – 35 Watt – Space qualified
Pin
PIN OUT
Single Output
Dual Output
Triple Output
1
Vin
Vin
Vin
2
Vin Return
Vin Return
Vin Return
3
Inhibit
Inhibit
Inhibit
4
Sync In
Sync In
Sync In
5
Sync Return
Sync Return
Sync Return
8
Sense
Sense A
Trim B
9
Sense Return
Vout A Return 1
Sense A Return
Vout B Negative
10
Vout A Return
Vout B Return
11
Vout A
Vout A
Vout B Positive
Trim B
Trim A
Vout B
Vout A
Vout B Return
Vout A Return
12
1
Trim
13
Vout A 1
14
Vout A Return
1
1. To meet specifications for Single Output models, Vout A pins (11 and 13) must be tied together and Vout A
Return pins (10 and 14) must be tied together.
Table 6: Pin Out
1
14
2
13
3
TOP VIEW
4
5
12
11
10
9
8
For dimensions see “Figure 66: Case S” on page 41.
Figure 6: Pin Out
PINS NOT IN USE
Inhibit
Leave unconnected
Sync In
Connect to Sync Return
Sense Lines (Single and Dual)
Must be connected to appropriate outputs
Trim
Leave unconnected
Table 7: Pins Not in Use
www.craneae.com/interpoint
Page 8 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
19-56 Volt input – 35 Watt – Space qualified
SMD Numbers
model numbering key
Base Model
Input Voltage
SMRT
28 515 T / K
R
Output Voltage
(single or dual Vout for single or dual models
main and aux. Vout for triple models)
Number of Outputs
(S=single, D=dual, T=triple)
Environmental Screening
Radiation Hardness
Assurance (RHA)
Figure 7: Model Numbering Key
Standard Microcircuit
Drawing (SMD)
SMRT Similar Part
5962R0622001KXC
SMRT283R3S/KR
5962R0622101KXC
SMRT2805S/KR
5962R1220101KXC
SMRT288R7S/KR
5962R0821001KXC
SMRT2812S/KR
5962R0622201KXC
SMRT2815S/KR
5962R0622301KXC
SMRT2805D/KR
5962R0720201KXC
SMRT2812D/KR
5962R0622401KXC
SMRT2815D/KR
5962R0821101KXC
SMRT283R312T/KR
5962R0821201KXC
SMRT283R315T/KR
5962R1322101KXC
SMRT28507T/KR
5962R0622501KXC
SMRT28512T/KR
5962R0622601KXC
SMRT28515T/KR
The SMD number shown is for Class K screening and
Radiation Hardness Assurance (RHA) level R. See the
SMD for the numbers for other screening and radiation
levels. For exact specifications for an SMD product, refer
to the SMD drawing. SMDs can be downloaded from:
www.landandmaritime.dla.mil/programs/smcr
Table 8: SMD Number Cross Reference
To
Category
Options
model Number Options
determine the model number enter one option from
each category in the form below.
Base Model and
Input Voltage
SMRT28
Output Voltage 1
Number of
Outputs 2
Screening 3
RHA 4
3R3, 05, 8R7, 12, 15
S
O
O
05, 12, 15
D
H
P
3R312, 3R315,
T
K
R
_______ 507, 512, 515
Fill in for
Model #
__________
SMRT28
__________
/
Notes:
1. Output Voltage: An R indicates a decimal point. 3R3 is 3.3 volts out. The 3R3 output voltage is only available in single and triple
output models. The 3R312 and 3R315 triple output converters are +3.3 volt main and ±12 or ±15 volt auxiliaries. The 507 triple
output converter is +5 main and ±7 volt auxiliaries. The 512 and 515 triple output converters are +5 volt main and ±12 or ±15 volt
auxiliaries.
2. Number of Outputs: S is a single output, D is a dual output, and T is a triple output
3. Screening: A screening level of O is a Space Prototype and is only used with RHA O. See Table 27 and Table 28 for more
information.
4. RHA: Interpoint model numbers use an “O” in the RHA designator position to indicate the “-” (dash) Radiation Hardness Assurance
level of MIL-PRF-38534, which is defined as “no RHA.” RHA O is only available with screening level O. See Table 28 for more
information.
Table 9: Model Number Options
www.craneae.com/interpoint
Page 9 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
19-56 Volt input – 35 Watt – Space qualified
Table 10: Operating Conditions - all models, 25° case, 28 Vin, unless otherwise specified.
All Models
PARAMETER
CONDITIONS
LEAD SOLDERING TEMPERATURE
1
10 seconds max.
STORAGE TEMPERATURE 1
MIN
TYP
MAX
UNITS
—
-65
—
300
°C
—
+150
°C
CASE OPERATING
FULL POWER
-55
—
+125
TEMPERATURE
ABSOLUTE 1
-55
—
+135
DERATING OUTPUT POWER/CURRENT 1
LINEARLY
ESD RATING
1
From 100% at 125°C to 0% at 135°C
MIL-STD-883 Method 3015
MIL-PRF-38534, 3.9.5.8.2
Class 3B
ISOLATION: input to output or @ 500 VDC
Any pin to case
UNDERVOLTAGE LOCKOUT 1
Rising Vin (Turn on)
Falling Vin (Turn off)
CURRENT LIMIT 2 °C
% OF FULL LOAD
—
­­—
≥8000
V
100
—
—
Megohms
13.07
—
16.37
12.26
—
15.80
V
—
145
—
%
—
50
—
dB
FREE RUN
-55° TO +125°C
270
300
330
kHz
SYNCHRONIZATION 3
INPUT FREQUENCY
270
—
330
kHz
Sync is floating and isolated
DUTY CYCLE 1
20
—
80
%
ACTIVE LOW
—
—
0.8
2.5
—
10
AUDIO REJECTION 1 CONVERSION FREQUENCY
ACTIVE HIGH
1
REFERENCED TO
IF NOT USED
V
SYNC RETURN
CONNECT TO sync return
INHIBIT ACTIVE LOW (OUTPUT DISABLED)
inhibit pin pulled low 1, 4
—
—
0.4
V
Do not apply a voltage to the Inhibit pin
INHIBIT PIN SOURCE
CURRENT 1
—
—
2
mA
REFERENCED TO
INHIBIT ACTIVE HIGH (OUTPUT ENABLED)
Do not apply a voltage to the Inhibit pin
INPUT COMMON
INHIBIT PIN CONDITION
OPEN PIN VOLTAGE 1
OPEN COLLECTOR OR
UNCONNECTED
5
—
6
V
For mean time between failures (MTBF) contact Applications Engineering
[email protected] +1.425.882.3100 option 7
Notes
1. Guaranteed by qualification test and/or analysis. Not an in-line test.
2. Triple outputs: The over-current limit will trigger when the sum of the auxiliary currents reaches 145% (typical value) of the maximum rated “total”
current of the auxiliary outputs.
3. If sync is used at lower end of range, full load operation is not guaranteed.
4. Tested with Inhibit pin at 0 volts.
www.craneae.com/interpoint
Page 10 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
19-56 Volt input – 35 Watt – Space qualified
Table 11: Electrical Characteristics: -55°C to +125°C case, 28 Vin, 100% load, free run, unless otherwise specified.
single output models
PARAMETER
SMRT283R3S
CONDITIONS
SMRT2805S
SMRT288R7S
UNITS
MIN
TYP
MAX
MIN
TYP
MAX
MIN
TYP
MAX
OUTPUT VOLTAGE
3.23
3.30
3.37
4.90
5.00
5.10
8.52
8.70
8.87
OUTPUT CURRENT
—
—
6.97
—
—
6.0
—
—
4.0
A
OUTPUT POWER
—
—
23
—
—
30
—
—
35
W
OUTPUT RIPPLE
TC = 25°C
V
—
—
250
—
—
180
—
—
160
TC = -55°C to +125°C
—
—
280
—
—
180
—
—
200
VIN = 19, 50 V
—
5
30
—
5
30
—
5
30
mV
NL - FL
—
5
40
—
5
40
—
5
40
mV
TOTAL REGULATION 1
VOUT
ALL CONDITIONS OF
LINE, LOAD, AGING,
TEMP AND RADIATION
3.0
—
3.6
4.7
—
5.3
8.3
—
9.1
V
INPUT VOLTAGE
CONTINUOUS
19
28
56
19
28
56
19
28
56
V
10 kHz - 20 MHz
LINE REGULATION
LOAD REGULATION
2
TRANSIENT 120 ms
INPUT CURRENT
INPUT RIPPLE CURRENT
3
EFFICIENCY
LOAD FAULT 4
STEP LOAD RESPONSE 5, 6, 7
STEP LINE RESPONSE
1, 5, 6
1
mV p-p
—
—
80
—
—
80
—
—
80
V
NO LOAD
—
—
110
—
—
110
—
—
115
mA
INHIBITED
—
—
50
—
—
50
—
—
50
10 kHz - 20 MHz
—
10
50
—
10
50
—
10
50
TC = 25°C
61
64
—
67
71
—
74
75.5
—
mA p-p
TC = -55°C to +125°C
60
—
—
66
­—
—
72
­—
—
POWER DISSIPATION
—
—
31
—
—
28
—
—
25
W
RECOVERY 1
—
—
25
—
—
25
—
—
25
ms
TRANSIENT
—
—
±450
—
—
±450
—
—
±450
mV pk
RECOVERY
—
—
3
—
—
3
—
—
4
ms
19 - 50 - 19 VIN
TRANSIENT
—
—
±500
—
—
±500
—
—
±600
mV pk
%
RECOVERY
—
—
4
—
—
4
—
—
4
ms
START-UP 8
DELAY —
—
35
—
—
25
—
—
25
ms
OVERSHOOT
—
—
50
—
—
50
—
—
95
mV pk
CAPACITIVE LOAD 1
TC = 25°C
UNCONDITIONALLY STABLE, START-UP
DELAY INCREASED
—
—
5000
—
—
5000
—
—
5000
µF
Notes
1. Guaranteed by qualification test and/or analysis. Not an in-line test.
2. To maintain regulation above 28 volts input, a minimum load is required of 0% at
28 volts input increasing linearly to 5% at 56 volts input.
3. Converters meet MIL-STD-461 specification revisions for conducted emissions
C-CE03 and D-/E-/F-CE-102. The actual value of input ripple current is much
less, the limit in the characteristic table is based on measurement resolution.
4. Maximum power dissipation when output is shorted.
www.craneae.com/interpoint
5.Recovery time is measured from application of the transient to point at which
VOUT is within 1% of VOUT at final value.
6. Transition time >10 µs.
7. Half load to/from full load.
8 Measured from release of inhibit or input voltage step.
Page 11 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
19-56 Volt input – 35 Watt – Space qualified
Table 12: Electrical Characteristics: -55°C to +125°C case, 28 Vin, 100% load, free run, unless otherwise specified.
single output models
PARAMETER
SMRT2812S
CONDITIONS
SMRT2815S
UNITS
MIN
TYP
MAX
MIN
TYP
MAX
OUTPUT VOLTAGE
11.76
12.00
12.24
14.70
15.00
15.30
OUTPUT CURRENT
—
—
2.92
0
—
2.33
A
OUTPUT POWER
—
—
35
0
—
35
W
OUTPUT RIPPLE
TC = 25°C
10 kHz - 20 MHz
LINE REGULATION
LOAD REGULATION
2
—
—
160
—
—
140
TC = -55°C to +125°C
—
—
200
—
—
180
VIN = 19, 50 V
—
5
30
—
5
30
mV
—
5
40
—
5
40
mV
10.9
—
13.1
14.0
—
16.0
V
19
28
56
19
28
56
V
NL - FL
TOTAL REGULATION 1
VOUT
ALL CONDITIONS OF
LINE, LOAD, AGING,
TEMP AND RADIATION
INPUT VOLTAGE
CONTINUOUS
TRANSIENT 120 ms
INPUT CURRENT
INPUT RIPPLE CURRENT
3
EFFICIENCY
LOAD FAULT 4
STEP LOAD RESPONSE 5, 6, 7
STEP LINE RESPONSE
START-UP 8
CAPACITIVE LOAD 1
TC = 25°C
1, 5, 6
1
mV p-p
—
—
80
—
—
80
V
NO LOAD
—
—
110
—
—
110
mA
INHIBITED
—
—
50
—
—
50
10 kHz - 20 MHz
—
10
50
—
10
50
TC = 25°C
76
78
—
76
80
—
TC = -55°C to +125°C
75
—
—
75
—
—
POWER DISSIPATION
—
—
20
—
—
20
W
RECOVERY 1
—
—
25
—
—
25
ms
TRANSIENT
—
—
±575
—
—
±575
mV pk
RECOVERY
—
—
3
—
—
3
ms
19 - 50 - 19 VIN
TRANSIENT
—
—
±700
—
—
±700
mV pk
mA p-p
%
RECOVERY
—
—
4
—
—
4
ms
DELAY —
—
25
—
—
25
ms
OVERSHOOT
—
—
120
—
—
150
mV pk
UNCONDITIONALLY STABLE, START-UP
DELAY INCREASED
—
—
5000
—
—
5000
µF
Notes
1. Guaranteed by qualification test and/or analysis. Not an in-line test.
2. To maintain regulation above 28 volts input, a minimum load is required of 0% at
28 volts input increasing linearly to 5% at 56 volts input.
3. Converters meet MIL-STD-461 specification revisions for conducted emissions
C-CE03 and D-/E-/F-CE-102. The actual value of input ripple current is much
less, the limit in the characteristic table is based on measurement resolution.
4. Maximum power dissipation when output is shorted.
www.craneae.com/interpoint
V
5.Recovery time is measured from application of the transient to point at which
VOUT is within 1% of VOUT at final value.
6. Transition time >10 µs.
7. Half load to/from full load.
8 Measured from release of inhibit or input voltage step.
Page 12 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
19-56 Volt input – 35 Watt – Space qualified
Table 13: Electrical Characteristics: -55°C to +125°C case, 28 Vin, 100% load, free run, unless otherwise specified.
DUAL output models
PARAMETER
OUTPUT VOLTAGE
OUTPUT CURRENT 2
OUTPUT POWER 2
OUTPUT RIPPLE
10 kHz - 20 MHz ± VOUT
LINE REGULATION
LOAD REGULATION
3
SMRT2805D
SMRT2815D
MIN
TYP
MAX
MIN
TYP
MAX
MIN
TYP
MAX
Vout A
4.90
5.00
5.10
11.76
12.00
12.24
14.70
15.00
15.30
Vout B
4.90
5.00
5.10
11.76
12.00
12.24
14.70
15.00
15.30
Vout A
—
—
3.0
—
—
1.46
—
—
1.17
Vout B
—
—
3.0
—
—
1.46
—
—
1.17
Vout A
—
—
15
—
—
17.5
—
—
17.5
Vout B
—
—
15
—
—
17.5
—
—
17.5
TC = 25°C
UNITS
V
A
W
—
—
180
—
—
150
—
—
140
TC = -55°C to +125°C
—
—
200
—
—
200
—
—
180
VIN = 19, 50 V
—
—
30
—
5
25
—
5
30
mV
—
5
40
—
5
50
—
5
40
mV
±4.6
—
±5.4
±10.9
—
±13.1
±14.0
—
±16.0
V
19
28
56
19
28
56
19
28
56
V
V
NL - FL
TOTAL REGULATION 1
VOUT
ALL CONDITIONS OF
LINE, LOAD, AGING,
TEMP AND RADIATION
INPUT VOLTAGE
CONTINUOUS
TRANSIENT 120 ms
INPUT CURRENT
SMRT2812D
CONDITIONS
1
—
—
80
—
—
80
—
—
80
NO LOAD
—
—
110
—
—
100
—
—
110
INHIBITED
—
—
50
—
—
50
—
—
50
mV p-p
mA
INPUT RIPPLE CURRENT 4
10 kHz - 20 MHz
—
10
50
—
10
50
—
10
50
EFFICIENCY
TC = 25°C
67
70
—
76
76
—
76
80
—
TC = -55°C to +125°C
66
—
—
75
—
—
75
—
—
POWER DISSIPATION
—
—
28
—
—
20
—
—
20
W
RECOVERY 1
—
—
25
—
—
25
—
—
25
ms
TRANSIENT
—
—
±450
—
—
±450
—
—
±575
mV pk
RECOVERY
—
—
3
—
—
2
—
—
3
ms
19 - 50 - 19 VIN
TRANSIENT
—
—
±500
—
—
±1000
—
—
±700
mv pk
RECOVERY
—
—
4
—
—
3
—
—
4
ms
DELAY
—
—
25
—
—
20
—
—
25
ms
OVERSHOOT
—
—
50
—
—
350
—
—
150
mV pk
UNCONDITIONALLY STABLE, START-UP
DELAY INCREASED
—
—
5000
—
—
5000
—
—
5000
µF
LOAD FAULT 5
STEP LOAD RESPONSE 6, 7, 8
STEP LINE RESPONSE 1, 6, 7
START-UP 9
CAPACITIVE LOAD 1, 10
TC = 25°C
Notes
1. Guaranteed by qualification test and/or analysis. Not an in-line test.
2. The specified maximum current/power is available from each output.
3. To maintain regulation above 28 volts input, a minimum load is required of 0% at
28 volts input increasing linearly to 5% at 56 volts input. Applies to both outputs.
4. Converters meet MIL-STD-461 specification revisions for conducted emissions
C-CE03 and D-/E-/F-CE-102. The actual value of input ripple current is much
less, the limit in the characteristic table is based on measurement resolution.
5. Maximum power dissipation when output is shorted.
www.craneae.com/interpoint
mA p-p
%
6. Recovery time is measured from application of the transient to point at which
VOUT is within 1% of VOUT at final value.
7. Transition time >10 µs.
8. Half load to/from full load.
9. Measured from release of inhibit or input voltage step.
10. Applies to each output.
Page 13 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
19-56 Volt input – 35 Watt – Space qualified
Table 14: Electrical Characteristics: -55°C to +125°C case, 28 Vin, 100% load, free run, unless otherwise specified.
triple output model – SMRT283R312T
3.3 (Main)
±12 (Auxiliaries)
UNITS
PARAMETER
CONDITIONS
MIN
TYP
MAX
MIN
TYP
MAX
OUTPUT VOLTAGE
Main and Pos. Aux
3.23
3.30
3.37
11.76
12.00
12.24
Neg. Aux.
—
—
—
-11.58
-12.00
-12.42
Either Output
—
—
4.5
—
±0.625
11
max Total AUX
—
—
—
—
—
1.25
Either Output
—
—
15
—
±7.5
12 1
MAX Total AUX
—
—
—
—
—
15
TC = 25°C
—
—
180
—
—
140
TC = -55°C to +125°C
—
—
200
—
—
150
LINE REGULATION
Main and POS. Aux
—
—
30
—
5
30
VIN = 19, 50 V
Neg. Aux.
—
—
—
—
10
70
LOAD REGULATION 3
Main & +Aux., NL - FL
—
5
40
—
5
40
Balanced Aux.
-Aux., NL - FL
—
—
—
—
10
300
TOTAL REGULATION 1
VOUT
ALL CONDITIONS OF LINE,
LOAD, AGING, TEMP AND
RADIATION
3.0
—
3.6
±10.9
—
±13.1
V
CROSS REGULATION 1, 4, 5
TC = 25°C
Effect on Negative Auxiliary
—
—
—
—
—
2.5
%
19
—
28
56
—
—
—
V
—
80
—
—
—
V
NO LOAD
—
—
110
—
—
—
INHIBITED
—
—
50
—
—
—
10 kHz - 20 MHz
—
10
50
—
—
—
OUTPUT CURRENT 2
OUTPUT POWER 2
OUTPUT RIPPLE
10 kHz - 20 MHz
INPUT VOLTAGE
CONTINUOUS
TRANSIENT 120 ms
INPUT CURRENT
INPUT RIPPLE CURRENT 6
EFFICIENCY 7
LOAD FAULT 8
STEP LOAD RESPONSE 9, 10, 11, 12
1
V
A
W
mV p-p
mV
mV
mA
mA p-p
TC = 25°C
69
70.5
—
—
—
—
TC = -55°C TO +125°C
68
—
—
—
—
—
POWER DISSIPATION
—
—
28
—
—
—
RECOVERY 1
—
—
25
—
—
25
ms
TRANSIENT
—
—
±450
—
—
±450
mV pk
%
W
RECOVERY
—
—
3
—
—
3
ms
STEP LINE RESPONSE 1, 9, 10
19 - 50 - 19 VIN TRANSIENT
RECOVERY
—
—
±500
—
—
±750
mV pk
—
—
4
—
—
4
ms
START-UP 13
DELAY —
—
35
—
—
25
ms
OVERSHOOT
—
0
50
—
0
120
mV pk
UNCONDITIONALLY STABLE,
START-UP DELAY INCREASED
—
—
5000
—
—
1000
µF
CAPACITIVE LOAD 1, 14
TC = 25°C
Notes: See page 19
www.craneae.com/interpoint
Page 14 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
19-56 Volt input – 35 Watt – Space qualified
Table 15: Electrical Characteristics: -55°C to +125°C case, 28 Vin, 100% load, free run, unless otherwise specified.
triple output model – SMRT283R315T
3.3 (Main)
±15 (Auxiliaries)
PARAMETER
CONDITIONS
MIN
TYP
MAX
MIN
TYP
MAX
OUTPUT VOLTAGE
Main and Pos. Aux
3.23
3.30
3.37
14.70
15.00
15.30
-14.48
-15.00
-15.53
Neg. Aux.
OUTPUT CURRENT 2
UNITS
V
Either Output
—
—
4.5
—
±0.5
0.8 1
max Total AUX
—
—
—
—
—
1.0
Either Output
—
—
15
—
±7.5
12 1
MAX Total AUX
—
—
—
—
—
15
TC = 25°C
—
—
180
—
—
140
TC = -55°C to +125°C
—
—
200
—
—
150
LINE REGULATION 3
Main and POS. Aux
—
—
30
VIN = 19, 50 V
Neg. Aux.
LOAD REGULATION
Main & +Aux., NL - FL
—
5
40
—
5
40
Balanced Aux.
-Aux., NL - FL
—
—
—
—
—
300
TOTAL REGULATION 1
VOUT
ALL CONDITIONS OF LINE,
LOAD, AGING, TEMP AND
RADIATION
3.0
—
3.6
±14.0
—
±16.0
V
CROSS REGULATION 1, 4, 5
TC = 25°C
Effect on Negative Auxiliary
—
—
—
—
—
2.5
%
CONTINUOUS
19
28
56
—
—
—
V
TRANSIENT 120 ms 1
—
—
80
—
—
—
V
NO LOAD
—
—
110
—
—
—
INHIBITED
—
—
50
—
—
—
OUTPUT POWER 2
OUTPUT RIPPLE
10 kHz - 20 MHz
INPUT VOLTAGE
INPUT CURRENT
—
5
30
—
10
70
A
W
mV p-p
mV
mV
mA
INPUT RIPPLE CURRENT 6
10 kHz - 20 MHz
—
10
50
—
—
—
EFFICIENCY 7
TC = 25°C
70
71
—
—
—
—
TC = -55°C to +125°C
68
—
—
—
—
—
POWER DISSIPATION
—
—
28
—
—
—
W
RECOVERY 1
—
—
25
—
—
25
ms
TRANSIENT
—
—
±450
—
—
±450
mV pk
RECOVERY
—
—
3
—
—
3
ms
LOAD FAULT 8
STEP LOAD RESPONSE 9, 10, 11, 12
STEP LINE RESPONSE
START-UP
13
CAPACITIVE LOAD 1, 14
TC = 25°C
1, 9, 10
19 - 50 - 19 VIN TRANSIENT
%
—
—
±500
—
—
±750
mV pk
RECOVERY
—
—
4
—
—
4
ms
DELAY —
—
35
—
—
25
ms
OVERSHOOT
—
0
50
—
0
150
mV pk
UNCONDITIONALLY STABLE,
START-UP DELAY INCREASED
—
—
5000
—
—
1000
µF
Notes: See page 19
www.craneae.com/interpoint
mA p-p
Page 15 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
19-56 Volt input – 35 Watt – Space qualified
Table 16: Electrical Characteristics: -55°C to +125°C case, 28 Vin, 100% load, free run, unless otherwise specified.
triple output model – SMRT28507T
PARAMETER
OUTPUT VOLTAGE
5 (Main)
±7 (Auxiliaries)
CONDITIONS
MIN
TYP
MAX
Main and Pos. Aux
4.90
5.00
5.10
Neg. Aux.
OUTPUT CURRENT 2
MIN
TYP
MAX
6.86
7.00
7.14
-6.79
7.00
-7.21
UNITS
V
Either Output
—
—
3.0
—
±1.00
1.2 1
max Total AUX
—
—
—
—
—
2.0
Either Output
—
—
15
—
±7.0
11.2 1
MAX Total AUX
—
—
—
—
—
14
TC = 25°C
—
—
180
—
—
170
TC = -55°C to +125°C
—
—
180
—
—
190
LINE REGULATION 3
Main and POS. Aux
—
—
30
—
—
100
VIN = 19, 50 V
Neg. Aux.
—
—
—
—
—
150
LOAD REGULATION
Main & +Aux., NL - FL
—
5
40
—
5
150
Balanced Aux.
-Aux., NL - FL
—
—
—
—
—
350
TOTAL REGULATION 1
VOUT
ALL CONDITIONS OF LINE,
LOAD, AGING, TEMP AND
RADIATION
4.7
—
5.3
±6.53
—
±7.47
V
CROSS REGULATION 1, 4, 5
TC = 25°C
Effect on Negative Auxiliary
—
—
—
—
—
2.5
%
CONTINUOUS
19
28
56
—
—
—
V
V
OUTPUT POWER 2
OUTPUT RIPPLE
10 kHz - 20 MHz
INPUT VOLTAGE
TRANSIENT 120 ms
1
—
—
80
—
—
—
NO LOAD
—
—
110
—
—
—
INHIBITED
—
—
50
—
—
—
INPUT RIPPLE CURRENT 6
10 kHz - 20 MHz
—
10
50
—
—
—
EFFICIENCY 7
TC = 25°C
70
71
—
—
—
—
TC = -55°C to +125°C
69
—
—
—
—
—
POWER DISSIPATION
—
—
28
—
—
—
RECOVERY 1
INPUT CURRENT
LOAD FAULT 8
A
W
mV p-p
mV
mV
mA
mA p-p
%
W
—
—
25
—
—
25
ms
STEP LOAD RESPONSE 9, 10, 11, 12 TRANSIENT
—
—
±300
—
—
±400
mV pk
RECOVERY
—
—
3
—
—
3
ms
STEP LINE RESPONSE 1, 9, 10
19 - 50 - 19 VIN TRANSIENT
RECOVERY
—
—
±500
—
—
±750
mV pk
—
—
3
—
—
3
ms
START-UP 13
DELAY —
—
25
—
—
25
ms
OVERSHOOT
—
0
50
—
0
70
mV pk
UNCONDITIONALLY STABLE,
START-UP DELAY INCREASED
—
—
5000
—
—
1000
µF
CAPACITIVE LOAD 1, 14
TC = 25°C
Notes: See page 19
www.craneae.com/interpoint
Page 16 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
19-56 Volt input – 35 Watt – Space qualified
Table 17: Electrical Characteristics: -55°C to +125°C case, 28 Vin, 100% load, free run, unless otherwise specified.
triple output model – SMRT28512T
5 (Main)
±12 (Auxiliaries)
PARAMETER
CONDITIONS
MIN
TYP
MAX
OUTPUT VOLTAGE
Main and Pos. Aux
4.90
5.00
5.10
Neg. Aux.
OUTPUT CURRENT 2
MIN
TYP
MAX
11.76
12.00
12.24
-11.58
-12.00
-12.42
UNITS
V
Either Output
—
—
3.0
—
±0.625
11
max Total AUX
—
—
—
—
—
1.25
Either Output
—
—
15
—
±7.5
12 1
MAX Total AUX
—
—
—
—
—
15
TC = 25°C
—
—
180
—
—
140
TC = -55°C to +125°C
—
—
200
—
—
150
LINE REGULATION 3
Main and POS. Aux
—
—
30
—
5
30
VIN = 19, 50 V
Neg. Aux.
—
20
70
LOAD REGULATION
Main & +Aux., NL - FL
—
5
40
—
5
40
Balanced Aux.
-Aux., NL - FL
—
—
—
—
10
300
TOTAL REGULATION 1
VOUT
ALL CONDITIONS OF LINE,
LOAD, AGING, TEMP AND
RADIATION
4.7
—
5.3
±10.9
—
±13.1
V
CROSS REGULATION 1, 4, 5
TC = 25°C
Effect on Negative Auxiliary
—
—
—
—
—
2.5
%
CONTINUOUS
19
28
56
—
—
—
V
V
OUTPUT POWER 2
OUTPUT RIPPLE
10 kHz - 20 MHz
INPUT VOLTAGE
TRANSIENT 120 ms
INPUT CURRENT
INPUT RIPPLE CURRENT 6
EFFICIENCY 7
LOAD FAULT 8
1
—
—
80
—
—
—
NO LOAD
—
—
110
—
—
—
INHIBITED
—
—
50
—
—
—
10 kHz - 20 MHz
—
10
50
—
—
—
TC = 25°C
69
75
—
—
—
—
TC = -55°C to +125°C
68
—
—
—
—
—
POWER DISSIPATION
—
—
25
—
—
—
A
W
mV p-p
mV
mV
mA
mA p-p
%
W
RECOVERY 1
—
—
25
—
—
25
ms
STEP LOAD RESPONSE 9, 10, 11, 12
TRANSIENT
—
—
±450
—
—
±450
mV pk
RECOVERY
—
—
3
—
—
3
ms
STEP LINE RESPONSE 1, 9, 10
19 - 50 - 19 VIN TRANSIENT
RECOVERY
—
—
±500
—
—
±750
mV pk
—
—
4
—
—
4
ms
START-UP 13
DELAY —
—
25
—
—
25
ms
OVERSHOOT
—
0
50
—
0
120
mV pk
UNCONDITIONALLY STABLE,
START-UP DELAY INCREASED
—
—
5000
—
—
1000
µF
CAPACITIVE LOAD 1, 14
TC = 25°C
Notes: See page 19
www.craneae.com/interpoint
Page 17 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
19-56 Volt input – 35 Watt – Space qualified
Table 18: Electrical Characteristics: -55°C to +125°C case, 28 Vin, 100% load, free run, unless otherwise specified.
triple output model – SMRT28515T
5 (Main)
±15 (Auxiliaries)
PARAMETER
CONDITIONS
MIN
TYP
MAX
OUTPUT VOLTAGE
Main and Pos. Aux
4.92
5.00
5.08
Neg. Aux.
OUTPUT CURRENT 2
MIN
TYP
MAX
14.77
15.00
15.23
-14.70
-15.00
-15.30
UNITS
V
Either Output
—
—
3.0
—
±0.5
0.80 1
max Total AUX
—
—
—
—
—
1
Either Output
—
—
15
—
±7.5
11.25 1
MAX Total AUX
—
—
—
—
—
15
TC = 25°C
—
—
180
—
—
150
TC = -55°C to +125°C
—
—
200
—
—
200
LINE REGULATION 3
Main and POS. Aux
—
5
25
—
—
25
VIN = 19, 50 V
Neg. Aux.
—
20
35
LOAD REGULATION
Main & +Aux., NL - FL
—
5
50
—
5
50
Balanced Aux.
-Aux., NL - FL
—
—
—
—
—
500
TOTAL REGULATION 1
VOUT
ALL CONDITIONS OF LINE,
LOAD, AGING, TEMP AND
RADIATION
4.7
—
5.3
±14.0
—
±16.0
V
CROSS REGULATION 1, 4, 5
TC = 25°C
Effect on Negative Auxiliary
—
—
—
—
—
2.5
%
CONTINUOUS
19
28
56
—
—
—
V
V
OUTPUT POWER 2
OUTPUT RIPPLE
10 kHz - 20 MHz
INPUT VOLTAGE
TRANSIENT 120 ms
1
A
W
mV p-p
mV
mV
—
—
80
—
—
—
NO LOAD
—
—
110
—
—
—
INHIBITED
—
—
50
—
—
—
INPUT RIPPLE CURRENT 6
10 kHz - 20 MHz
—
10
50
—
—
—
EFFICIENCY 7
TC = 25°C
72
75
—
—
—
—
TC = -55°C to +125°C
70
—
—
—
—
—
POWER DISSIPATION
—
—
25
—
—
—
RECOVERY 1
—
—
35
—
—
35
ms
STEP LOAD RESPONSE 9, 10, 11, 12
TRANSIENT
—
—
±250
—
—
±350
mV pk
RECOVERY
—
—
1
—
—
1
ms
STEP LINE RESPONSE 1, 9, 10
19 - 50 - 19 VIN TRANSIENT
RECOVERY
—
—
±500
—
—
±750
mV pk
—
—
1.5
—
—
1.5
ms
START-UP 13
DELAY —
—
25
—
—
20
ms
OVERSHOOT
—
0
200
—
0
350
mV pk
UNCONDITIONALLY STABLE,
START-UP DELAY INCREASED
—
—
5000
—
—
1000
µF
INPUT CURRENT
LOAD FAULT 8
CAPACITIVE LOAD 1, 14
TC = 25°C
Notes: See page 19
www.craneae.com/interpoint
Page 18 of 44
SMRT28 Rev AH - 2015.02.20
mA
mA p-p
%
W
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
19-56 Volt input – 35 Watt – Space qualified
Electrical Characteristics: -55°C to +125°C case, 28 Vin, 100% load, free run, unless otherwise specified.
NOTES: For triple output models on Table 14 through Table 18. 1. Guaranteed by qualification test and/or analysis. Not an in-line test.
2. Up to the maximum specified auxiliary output current/power is available from either auxiliary output provided the total auxiliary output current/
power does not exceed the total current/power specified.
3. To maintain regulation above 28 volts input, a minimum load is required of 0% at 28 volts input increasing linearly to 5% at 56 volts input. Applies
to each output.
4. To maintain the cross regulation specification, one of the auxiliaries must always provide a minimum of 20% of the total auxiliary power used.
Negative Vout cross regulation is referenced to 50%/50% balanced loads (at 100% of total rated output power - full load).
5. Cross regulation is measured under the following conditions:
Condition 1: +POUT = 20 - 80%,/- POUT = 80 - 20%
Condition 2: - POUT = 20 - 80%, /+ POUT = 80 - 20%
6. Converters meet MIL-STD-461 specification revisions for conducted emissions C-CE03 and D-/E-/F-CE-102. The actual value of input ripple
current is much less, the limit in the characteristic table is based on measurement resolution.
7. Efficiency measured with all outputs at full load.
8. Maximum power dissipation when all outputs are shorted simultaneously.
9.Recovery time is measured from application of the transient to point at which VOUT is within 1% of VOUT at final value.
10. Transition time >10 µs.
11. Half load to/from full load.
12. The step load specification for the negative auxiliary output is guaranteed by qualification test. It is not an in-line test.
13. Measured from release of inhibit or input voltage step.
14. Applies to each auxiliary.
www.craneae.com/interpoint
Page 19 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
50 Volt Input Specifications
Table 19: Electrical Characteristics: -55°C to +125°C case, 50 Vin, 100% load, free run, unless otherwise specified.
single output models
SMRT283R3S
SMRT2805S
SMRT288R7S
UNITS
PARAMETER
CONDITIONS
MIN
TYP
MAX
MIN
TYP
MAX
MIN
TYP
MAX
OUTPUT VOLTAGE
28 VIN
3.23
3.30
3.37
4.90
5.00
5.10
8.52
8.70
8.87
V
0.28
—
6.97
0.24
—
6.0
0.16
—
4.0
A
W
OUTPUT CURRENT
OUTPUT POWER
OUTPUT RIPPLE
TC = 25°C
10 kHz - 20 MHz
TC = -55°C to +125°C
LINE REGULATION 2
0.92
—
23
1.2
—
30
1.4
—
35
—
—
250
—
—
200
—
—
200
—
—
280
—
—
200
—
—
200
mV p-p
—
—
30
—
—
30
—
—
30
VIN = 56 V
—
—
60
—
—
60
—
—
30
LOAD REGULATION
TOTAL REGULATION 1
VOUT
5% - FL
—
—
80
—
—
70
—
—
80
mV
ALL CONDITIONS OF
LINE, LOAD, AGING,
TEMP AND RADIATION
3.0
—
3.6
4.7
—
5.3
8.3
—
9.1
V
INPUT VOLTAGE
CONTINUOUS
19
28
56
19
28
56
19
28
56
V
TRANSIENT 1 120 ms
—
—
80
—
—
80
—
—
80
V
INPUT CURRENT
INPUT RIPPLE CURRENT 3
EFFICIENCY
LOAD FAULT 4
STEP LOAD RESPONSE 5, 6, 7
STEP LINE RESPONSE
1, 5, 6
NO LOAD
—
—
100
—
—
100
—
—
105
INHIBITED
—
—
55
—
—
55
—
—
55
10 kHz - 20 MHz
—
—
60
—
—
60
—
—
60
mV
mA
mA p-p
TC = 25°C
60
—
—
66
—
—
72
—
—
TC = -55°C to +125°C
60
—
—
66
—
—
72
—
—
POWER DISSIPATION
—
—
33
—
—
33
—
—
28
W
RECOVERY 1
—
—
25
—
—
25
—
—
25
ms
%
TRANSIENT
—
—
±450
—
—
±450
—
—
±450
mV pk
RECOVERY
—
—
3
—
—
3
—
—
4
ms
19 - 56 - 19 VIN
TRANSIENT
—
—
±500
—
—
±500
—
—
±500
mV pk
RECOVERY
—
—
4
—
—
4
—
—
4
ms
START-UP 8
DELAY —
—
35
—
—
25
—
—
25
ms
OVERSHOOT
—
—
50
—
—
50
—
—
95
mV pk
CAPACITIVE LOAD 1
TC = 25°C
UNCONDITIONALLY STABLE, START-UP
DELAY INCREASED
—
—
5000
—
—
5000
—
—
5000
µF
Notes
1. Guaranteed by qualification test and/or analysis. Not an in-line test.
2. To maintain regulation above 28 volts input, a minimum load is required of 0% at
28 volts in increasing linearly to 5% at 56 volts in.
2. Converters meet MIL-STD-461 specification revisions for conducted emissions
C-CE03 and D-/E-/F-CE-102. The actual value of input ripple current is much
less, the limit in the characteristic table is based on measurement resolution.
4. Maximum power dissipation when output is shorted.
www.craneae.com/interpoint
5.Recovery time is measured from application of the transient to point at which
VOUT is within 1% of VOUT at final value.
6. Transition time >10 µs.
7. Half load to/from full load.
8. Measured from release of inhibit or input voltage step.
Page 20 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
50 Volt Input Specifications
Table 20: Electrical Characteristics: -55°C to +125°C case, 50 Vin, 100% load, free run, unless otherwise specified.
single output models
SMRT2812S
SMRT2815S
UNITS
PARAMETER
CONDITIONS
MIN
TYP
MAX
MIN
TYP
MAX
OUTPUT VOLTAGE
28 VIN
11.76
12.00
12.24
14.70
15.00
15.30
0.116
—
2.92
0.093
—
2.33
A
1.4
—
35
1.4
—
35
W
OUTPUT CURRENT
OUTPUT POWER
OUTPUT RIPPLE
TC = 25°C
10 kHz - 20 MHz
TC = -55°C to +125°C
LINE REGULATION 2
LOAD REGULATION
TOTAL REGULATION
VOUT
1
INPUT VOLTAGE
—
200
—
—
180
—
200
—
—
180
—
—
25
—
—
30
—
—
50
—
—
60
5% - FL
—
—
70
—
—
90
mV
10.9
—
13.1
14.0
—
16.0
V
19
28
56
19
28
56
V
V
ALL CONDITIONS OF
LINE, LOAD, AGING,
TEMP AND RADIATION
CONTINUOUS
1
—
—
80
—
—
80
NO LOAD
120 ms
—
—
100
—
—
100
INHIBITED
—
—
55
—
—
55
INPUT RIPPLE CURRENT 3
10 kHz - 20 MHz
—
—
60
—
—
60
EFFICIENCY
TC = 25°C
72
—
—
72
—
—
TC = -55°C to +125°C
72
—
—
72
—
—
POWER DISSIPATION
—
—
28
—
—
28
LOAD FAULT 4
STEP LOAD RESPONSE 5, 6, 7
STEP LINE RESPONSE 1, 5, 6
START-UP 8
CAPACITIVE LOAD 1
TC = 25°C
mV
mA
mA p-p
%
W
RECOVERY 1
—
—
25
—
—
25
ms
TRANSIENT
—
—
±575
—
—
±575
mV pk
RECOVERY
—
—
3
—
—
3
ms
19 - 56 - 19 VIN
TRANSIENT
—
—
±700
—
—
±700
mV pk
RECOVERY
—
—
4
—
—
4
ms
DELAY —
—
25
—
—
25
ms
OVERSHOOT
—
—
120
—
—
150
mV pk
UNCONDITIONALLY STABLE, START-UP
DELAY INCREASED
—
—
5000
—
—
5000
µF
Notes
1. Guaranteed by qualification test and/or analysis. Not an in-line test.
2. To maintain regulation above 28 volts input, a minimum load is required of 0% at
28 volts in increasing linearly to 5% at 56 volts in.
2. Converters meet MIL-STD-461 specification revisions for conducted emissions
C-CE03 and D-/E-/F-CE-102. The actual value of input ripple current is much
less, the limit in the characteristic table is based on measurement resolution.
4. Maximum power dissipation when output is shorted.
www.craneae.com/interpoint
mV p-p
VIN = 56 V
TRANSIENT
INPUT CURRENT
—
—
V
5.Recovery time is measured from application of the transient to point at which
VOUT is within 1% of VOUT at final value.
6. Transition time >10 µs.
7. Half load to/from full load.
8. Measured from release of inhibit or input voltage step.
Page 21 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
50 Volt Input Specifications
Table 21: Electrical Characteristics: -55°C to +125°C case, 50 Vin, 100% load, free run, unless otherwise specified.
DUAL output models
SMRT2805D
SMRT2812D
SMRT2815D
UNITS
PARAMETER
CONDITIONS
MIN
TYP
MAX
MIN
TYP
MAX
MIN
TYP
MAX
OUTPUT VOLTAGE
Vout A
4.90
5.00
5.10
11.76
12.00
12.24
14.70
15.00
15.30
28 VIN
Vout B
4.90
5.00
5.10
11.76
12.00
12.24
14.70
15.00
15.30
Vout A
0.12
—
3.0
0.06
—
1.46
0.05
—
1.17
Vout B
0.12
—
3.0
0.06
—
1.46
0.05
—
1.17
Vout A
0.60
—
15
0.70
—
17.5
0.70
—
17.5
Vout B
0.60
—
15
0.70
—
17.5
0.70
—
17.5
—
—
200
—
—
170
—
—
180
—
—
200
—
—
200
—
—
180
—
—
30
—
—
25
—
—
30
VIN = 56 V
—
—
60
—
—
25
—
—
60
50 Vin, 5% - FL
—
—
70
—
—
100
—
—
70
mV
±4.6
—
±5.4
±10.9
—
±13.1
±14.0
—
±16.0
V
CONTINUOUS
19
28
56
19
28
56
19
28
56
V
TRANSIENT 120 ms
—
—
80
—
—
80
—
—
80
V
NO LOAD
—
—
100
—
—
100
—
—
100
INHIBITED
—
—
55
—
—
55
—
—
55
OUTPUT CURRENT 2
OUTPUT POWER 2
OUTPUT RIPPLE
10 kHz - 20 MHz ± VOUT
TC = 25°C
TC = -55°C to +125°C
LINE REGULATION 3
LOAD REGULATION
TOTAL REGULATION 1
VOUT
INPUT VOLTAGE
INPUT CURRENT
ALL CONDITIONS OF
LINE, LOAD, AGING,
TEMP AND RADIATION
V
A
W
mV p-p
mV
mA
INPUT RIPPLE CURRENT 4
10 kHz - 20 MHz
—
—
60
—
—
60
—
—
60
EFFICIENCY
TC = 25°C
66
—
—
72
—
—
72
—
—
TC = -55°C to +125°C
66
—
—
72
—
—
70
—
—
POWER DISSIPATION
—
—
33
—
—
28
—
—
28
W
RECOVERY 1
—
—
25
—
—
25
—
—
25
ms
LOAD FAULT 5
STEP LOAD RESPONSE 6, 7, 8
STEP LINE RESPONSE 1, 6, 7
mA p-p
%
TRANSIENT
—
—
±450
—
—
±450
—
—
±575
mV pk
RECOVERY
—
—
3
—
—
2
—
—
3
ms
19 - 56 - 19 VIN
TRANSIENT
—
—
±500
—
—
±1000
—
—
±700
mv pk
RECOVERY
—
—
4
—
—
3
—
—
4
ms
START-UP 9
DELAY
—
—
25
—
—
20
—
—
25
ms
OVERSHOOT
—
—
50
—
—
350
—
—
150
mV pk
CAPACITIVE LOAD 1, 10
TC = 25°C
UNCONDITIONALLY STABLE, START-UP
DELAY INCREASED
—
—
5000
—
—
5000
—
—
5000
µF
Notes
1. Guaranteed by qualification test and/or analysis. Not an in-line test.
2. The specified maximum current/power is available from each output.
3. To maintain regulation above 28 volts input, a minimum load is required of 0% at
28 volts input increasing linearly to 5% at 56 volts input. Applies to both outputs.
4. Converters meet MIL-STD-461 specification revisions for conducted emissions
C-CE03 and D-/E-/F-CE-102. The actual value of input ripple current is much
less, the limit in the characteristic table is based on measurement resolution.
5. Maximum power dissipation when output is shorted.
www.craneae.com/interpoint
6. Recovery time is measured from application of the transient to point at which
VOUT is within 1% of VOUT at final value.
7. Transition time >10 µs.
8. Half load to/from full load.
9. Measured from release of inhibit or input voltage step.
10. Applies to each output.
Page 22 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
50 Volt Input Specifications
Table 22: Electrical Characteristics: -55°C to +125°C case, 50 Vin, 100% load, free run, unless otherwise specified.
triple output model – SMRT283R312T
3.3 (Main)
±12 (Auxiliaries)
UNITS
PARAMETER
CONDITIONS
MIN
TYP
MAX
MIN
TYP
MAX
OUTPUT VOLTAGE
Main and Pos. Aux
3.23
3.30
3.37
11.76
12.00
12.24
28 VIN
Neg. Aux.
—
—
—
-11.58
-12.00
-12.42
0.18
—
4.5
±0.04
±0.63
11
—
—
—
—
—
1.25
0.60
—
15
0.48
±7.5
12 1
Max Total Aux
—
—
—
—
—
15
TC = 25°C
—
—
200
—
—
150
TC = -55°C to +125°C
—
—
200
—
—
150
Main and POS. Aux
—
—
30
—
—
30
Neg. Aux.
—
—
—
—
—
70
LINE REGULATION 3
Main and POS. Aux
—
—
60
—
—
60
VIN = 56 V
Neg. Aux.
—
—
—
—
—
140
LOAD REGULATION
Main & +Aux., 5% - FL
—
—
100
—
—
120 Balanced Aux.
-Aux., 5% - FL
—
—
—
—
—
300
TOTAL REGULATION 1
VOUT
ALL CONDITIONS OF LINE, LOAD,
AGING, TEMP AND RADIATION
3.0
—
3.6
±10.9
—
±13.1
V
CROSS REGULATION 1, 4, 5
TC = 25°C
Effect on Negative Auxiliary
—
—
—
—
—
2.5
%
CONTINUOUS
19
28
56
—
—
—
V
V
OUTPUT CURRENT 2
Max Total Aux.
OUTPUT POWER 2
OUTPUT RIPPLE
10 kHz - 20 MHz
LINE REGULATION 3
INPUT VOLTAGE
TRANSIENT 120 ms
1
V
A
W
mV p-p
mV
mV
mV
—
—
80
—
—
—
NO LOAD
—
—
100
—
—
—
INHIBITED
—
—
55
—
—
—
INPUT RIPPLE CURRENT 6
10 kHz - 20 MHz
—
—
60
—
—
—
EFFICIENCY 7
TC = 25°C
67
—
—
—
—
—
TC = -55°C to +125°C
67
—
—
—
—
—
POWER DISSIPATION
—
—
35
—
—
—
RECOVERY 1
—
—
2.5
—
—
2.5
ms
TRANSIENT
—
—
±450
—
—
±450
mV pk
INPUT CURRENT
LOAD FAULT 8
STEP LOAD RESPONSE 9, 10, 11, 12
mA
mA p-p
%
W
RECOVERY
—
—
2.5
—
—
2.5
ms
STEP LINE RESPONSE 1, 9, 10
19 - 56 - 19 VIN TRANSIENT
RECOVERY
—
—
±500
—
—
±750
mV pk
—
—
4
—
—
4
ms
START-UP 13
DELAY —
—
35
—
—
25
ms
OVERSHOOT
—
—
50
—
—
120
mV pk
UNCONDITIONALLY STABLE,
START-UP DELAY INCREASED
—
—
5000
—
—
1000
µF
CAPACITIVE LOAD 1, 14
TC = 25°C
Notes: See page 28
www.craneae.com/interpoint
Page 23 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
50 Volt Input Specifications
Table 23: Electrical Characteristics: -55°C to +125°C case, 50 Vin, 100% load, free run, unless otherwise specified.
triple output model – SMRT283R315T
3.3 (Main)
±15 (Auxiliaries)
PARAMETER
CONDITIONS
MIN
TYP
MAX
MIN
TYP
MAX
OUTPUT VOLTAGE
Main and Pos. Aux
3.23
3.30
3.37
14.70
15.00
15.30
28 VIN
Neg. Aux.
-14.48
-15.00
-15.53
OUTPUT CURRENT 2
0.18
—
4.5
±0.02
±0.5
0.8 1
—
—
—
—
—
1.0
0.06
—
15
0.48
±7.5
12 1
Max Total Aux
—
—
—
—
—
15
TC = 25°C
—
—
200
—
—
150
TC = -55°C to +125°C
—
—
200
—
—
150
Main and POS. Aux
—
—
30
—
—
30
Neg. Aux.
—
—
—
—
—
70
Max Total Aux.
OUTPUT POWER 2
OUTPUT RIPPLE
10 kHz - 20 MHz
LINE REGULATION 3
LINE REGULATION 3
Main and POS. Aux
—
—
60
—
—
60
VIN = 56 V
Neg. Aux.
—
—
—
—
—
140
Main & +Aux., 50 Vin, 5% - FL
-Aux., 50 Vin, 5% - FL
—
—
100
—
—
120 —
—
—
—
—
300
LOAD REGULATION
Balanced Aux.
TOTAL REGULATION 1
VOUT
ALL CONDITIONS OF LINE, LOAD,
AGING, TEMP AND RADIATION
CROSS REGULATION 1, 4, 5
TC = 25°C
INPUT VOLTAGE
INPUT CURRENT
V
—
—
—
—
—
2.5
%
CONTINUOUS
19
28
56
—
—
—
V
TRANSIENT 120 ms 1
—
—
80
—
—
—
V
NO LOAD
—
—
95
—
—
—
INHIBITED
—
—
55
—
—
—
—
60
—
—
—
—
—
—
—
TC = -55°C to +125°C
68
—
—
—
—
—
mA
mA p-p
%
POWER DISSIPATION
—
—
35
—
—
—
W
RECOVERY 1
—
—
25
—
—
25
ms
TRANSIENT
—
—
±350
—
—
±350
mV pk
RECOVERY
—
—
2.5
—
—
2.5
ms
19 - 56 - 19 VIN TRANSIENT
—
—
±500
—
—
±750
mV pk
RECOVERY
—
—
4
—
—
4
ms
DELAY —
—
35
—
—
25
ms
OVERSHOOT
—
—
50
—
—
150
mV pk
UNCONDITIONALLY STABLE,
START-UP DELAY INCREASED
—
—
5000
—
—
1000
µF
Notes: See page 28
www.craneae.com/interpoint
mV
±16.0
—
CAPACITIVE LOAD 1, 14
TC = 25°C
mV
—
—
START-UP
mV
±14.0
68
13
mV p-p
3.6
TC = 25°C
STEP LINE RESPONSE
W
—
10 kHz - 20 MHz
1, 9, 10
A
3.0
EFFICIENCY 7
STEP LOAD RESPONSE 9, 10, 11, 12
V
Effect on Negative Auxiliary
INPUT RIPPLE CURRENT 6
LOAD FAULT 8
UNITS
Page 24 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
50 Volt Input Specifications
Table 24: Electrical Characteristics: -55°C to +125°C case, 50 Vin, 100% load, free run, unless otherwise specified.
triple output model – SMRT28507T
5 (Main)
±7 (Auxiliaries)
PARAMETER
CONDITIONS
MIN
TYP
MAX
OUTPUT VOLTAGE
Main and Pos. Aux
4.90
5.00
5.10
28 VIN
Neg. Aux.
OUTPUT CURRENT 2
Max Total Aux.
OUTPUT POWER 2
Max Total Aux
OUTPUT RIPPLE
TC = 25°C
10 kHz - 20 MHz
LINE REGULATION 3
MIN
TYP
MAX
6.86
7.00
7.14
-6.79
7.00
-7.21
0.12
—
3.0
±0.04
±1.00
1.2 1
—
—
—
—
—
2.0
0.60
—
15
0.28
±7.0
11.2 1
—
—
—
—
—
14
—
—
230
—
—
200
TC = -55°C TO +125°C
—
—
230
—
—
200
Main and POS. Aux
—
—
30
—
—
100
Neg. Aux.
—
—
—
—
—
150
UNITS
V
A
W
mV p-p
mV
LINE REGULATION 3
Main and POS. Aux
—
—
30
—
—
100
VIN = 56 V
Neg. Aux.
—
—
—
—
—
150
Main & +Aux., 50 Vin, 5% - FL
—
—
100
—
—
120 Balanced Aux.
-Aux., 50 Vin, 5% - FL
ALL CONDITIONS OF LINE, LOAD,
AGING, TEMP AND RADIATION
—
—
—
—
—
300
4.7
—
5.3
±6.53
—
±7.47
V
Effect on Negative Auxiliary
—
—
—
—
—
2.5
%
CONTINUOUS
19
28
56
—
—
—
V
V
LOAD REGULATION
TOTAL REGULATION 1
VOUT
CROSS REGULATION
TC = 25°C
1, 4, 5
INPUT VOLTAGE
TRANSIENT 120 ms
1
—
—
80
—
—
—
NO LOAD
—
—
95
—
—
—
INHIBITED
—
—
55
—
—
—
INPUT RIPPLE CURRENT 6
10 kHz - 20 MHz
—
—
60
—
—
—
EFFICIENCY 7
TC = 25°C
INPUT CURRENT
LOAD FAULT 8
STEP LOAD RESPONSE 9, 10, 11, 12
mV
mV
mA
mA p-p
68
—
—
—
—
—
TC = -55°C TO +125°C
68
—
—
—
—
—
POWER DISSIPATION
—
—
33
—
—
—
RECOVERY 1
—
—
25
—
—
25
ms
TRANSIENT
—
—
±300
—
—
±400
mV pk
%
W
RECOVERY
—
—
2
—
—
2
ms
STEP LINE RESPONSE 1, 9, 10
19 - 56 - 19 VIN TRANSIENT
RECOVERY
—
—
±500
—
—
±750
mV pk
—
—
4
—
—
4
ms
START-UP 13
DELAY —
—
20
—
—
20
ms
OVERSHOOT
—
—
50
—
—
70
mV pk
UNCONDITIONALLY STABLE,
START-UP DELAY INCREASED
—
—
5000
—
—
1000
µF
CAPACITIVE LOAD 1, 14
TC = 25°C
Notes: See page 28
www.craneae.com/interpoint
Page 25 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
50 Volt Input Specifications
Table 25: Electrical Characteristics: -55°C to +125°C case, 50 Vin, 100% load, free run, unless otherwise specified.
triple output model – SMRT28512T
5 (Main)
±12 (Auxiliaries)
PARAMETER
CONDITIONS
MIN
TYP
MAX
MIN
TYP
MAX
OUTPUT VOLTAGE
Main and Pos. Aux
4.90
5.00
5.10
11.76
12.00
12.24
28 VIN
Neg. Aux.
-11.58
-12.00
-12.42
OUTPUT CURRENT 2
0.12
—
3.0
±0.03
±0.63
11
—
—
—
—
—
1.25
0.60
—
15
0.48
±7.5
12 1
MAX Total AUX
—
—
—
—
—
15
TC = 25°C
—
—
200
—
—
150
TC = -55°C to +125°C
—
—
200
—
—
150
Main and POS. Aux
—
—
30
—
—
30
Neg. Aux.
—
—
—
—
—
70
max Total AUX
OUTPUT POWER 2
OUTPUT RIPPLE
10 kHz - 20 MHz
LINE REGULATION 3
LINE REGULATION 3
Main and POS. Aux
—
—
60
—
—
60
VIN = 56 V
Neg. Aux.
—
—
—
—
—
140
Main & +Aux., 50 Vin, 5% - FL
-Aux., 50 Vin, 5% - FL
—
—
100
—
—
120 —
—
—
—
—
300
LOAD REGULATION
Balanced Aux.
TOTAL REGULATION 1
VOUT
CROSS REGULATION 1, 4, 5
TC = 25°C
INPUT VOLTAGE
ALL CONDITIONS OF LINE, LOAD,
AGING, TEMP AND RADIATION
A
W
mV p-p
mV
mV
mV
4.7
—
5.3
±10.9
—
±13.1
V
—
—
—
—
—
2.5
%
CONTINUOUS
19
28
56
—
—
—
V
V
TRANSIENT 120 ms
1
—
—
80
—
—
—
—
—
100
—
—
—
INHIBITED
—
—
55
—
—
—
INPUT RIPPLE CURRENT 6
10 kHz - 20 MHz
—
—
60
—
—
—
EFFICIENCY 7
TC = 25°C
70
—
—
—
—
—
TC = -55°C to +125°C
70
—
—
—
—
—
POWER DISSIPATION
—
—
33
—
—
—
LOAD FAULT 8
V
Effect on Negative Auxiliary
NO LOAD
INPUT CURRENT
UNITS
mA
mA p-p
%
W
RECOVERY 1
—
—
25
—
—
25
ms
STEP LOAD RESPONSE 9, 10, 11, 12
TRANSIENT
—
—
±350
—
—
±350
mV pk
RECOVERY
—
—
2.5
—
—
2.5
ms
STEP LINE RESPONSE 1, 9, 10
19 - 56 - 19 VIN TRANSIENT
RECOVERY
—
—
±500
—
—
±750
mV pk
—
—
4
—
—
4
ms
START-UP 13
DELAY —
—
20
—
—
20
ms
OVERSHOOT
—
—
50
—
—
120
mV pk
UNCONDITIONALLY STABLE,
START-UP DELAY INCREASED
—
—
5000
—
—
1000
µF
CAPACITIVE LOAD 1, 14
TC = 25°C
Notes: See page 28
www.craneae.com/interpoint
Page 26 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
50 Volt Input Specifications
Table 26: Electrical Characteristics: -55°C to +125°C case, 50 Vin, 100% load, free run, unless otherwise specified.
triple output model – SMRT28515T
5 (Main)
±15 (Auxiliaries)
PARAMETER
CONDITIONS
MIN
TYP
MAX
MIN
TYP
MAX
OUTPUT VOLTAGE
Main and Pos. Aux
4.92
5.00
5.08
14.77
15.00
15.23
28 VIN
Neg. Aux.
-14.70
-15.00
-15.30
OUTPUT CURRENT 2
0.12
—
3.0
±0.02
±0.5
0.80 1
—
—
—
—
—
1
0.60
—
15
0.30
±7.5
11.25 1
Max Total Aux
—
—
—
—
—
15
TC = 25°C
—
—
200
—
—
200
—
—
200
—
—
200
Max Total Aux.
OUTPUT POWER 2
OUTPUT RIPPLE
10 kHz - 20 MHz
LINE REGULATION 3
TC = -55°C to +125°C
Main and POS. Aux
—
—
25
—
—
25
Neg. Aux.
—
—
—
—
—
35
LINE REGULATION 3
Main and POS. Aux
—
—
50
—
—
50
VIN = 56 V
Neg. Aux.
—
—
—
—
—
70
Main & +Aux., 50 Vin, 5% - FL
-Aux., 50 Vin, 5% - FL
—
—
100
—
—
120 —
—
—
—
—
300
LOAD REGULATION
Balanced Aux.
TOTAL REGULATION 1
VOUT
CROSS REGULATION 1, 4, 5
TC = 25°C
INPUT VOLTAGE
ALL CONDITIONS OF LINE, LOAD,
AGING, TEMP AND RADIATION
UNITS
V
A
W
mV p-p
mV
mV
mV
4.7
—
5.3
±14.0
—
±16.0
V
Effect on Negative Auxiliary
—
—
—
—
—
2.5
%
CONTINUOUS
19
28
56
—
—
—
V
V
TRANSIENT 120 ms
1
—
—
80
—
—
—
NO LOAD
—
—
100
—
—
—
INHIBITED
—
—
55
—
—
—
INPUT RIPPLE CURRENT 6
10 kHz - 20 MHz
—
—
50
—
—
—
EFFICIENCY 7
TC = 25°C
70
—
—
—
—
—
TC = -55°C to +125°C
70
—
—
—
—
—
POWER DISSIPATION
—
—
33
—
—
—
RECOVERY 1
—
—
35
—
—
35
ms
STEP LOAD RESPONSE 9, 10, 11, 12
TRANSIENT
—
—
±250
—
—
±350
mV pk
RECOVERY
—
—
1
—
—
1
ms
STEP LINE RESPONSE 1, 9, 10
19 - 56 - 19 VIN TRANSIENT
RECOVERY
—
—
±500
—
—
±750
mV pk
—
—
1.5
—
—
1.5
ms
START-UP 13
DELAY —
—
25
—
—
20
ms
OVERSHOOT
—
—
200
—
—
350
mV pk
UNCONDITIONALLY STABLE,
START-UP DELAY INCREASED
—
—
5000
—
—
1000
µF
INPUT CURRENT
LOAD FAULT 8
CAPACITIVE LOAD 1, 14
TC = 25°C
Notes: See page 28
www.craneae.com/interpoint
Page 27 of 44
SMRT28 Rev AH - 2015.02.20
mA
mA p-p
%
W
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
50 Volt Input Specifications
Electrical Characteristics: -55°C to +125°C case, 50 Vin, 100% load, free run, unless otherwise specified.
Notes: For triple output models on Table 22 through Table 26.
1. Guaranteed by qualification test and/or analysis. Not an in-line test.
2. Up to the maximum specified auxiliary output current/power is available from either auxiliary output provided the total auxiliary output current/
power does not exceed the total current/power specified.
3. To maintain regulation above 28 volts input, a minimum load is required of 0% at 28 volts input increasing linearly to 5% at 56 volts in. Load
percentage applies to the main output and also to the sum of the auxiliaries.
4. To maintain the cross regulation specification, one of the auxiliaries must always provide a minimum of 20% of the total auxiliary power used. Negative Vout cross regulation is referenced to 50%/50% balanced loads (at 100% of total rated output power - full load).
5. Cross regulation is measured under the following conditions:
Condition 1: +POUT = 20 - 80%,/- POUT = 80 - 20%
Condition 2: - POUT = 20 - 80%, /+ POUT = 80 - 20%
6. Converters meet MIL-STD-461 specification revisions for conducted emissions C-CE03 and D-/E-/F-CE-102. The actual value of input ripple current is much less, the limit in the characteristic table is based on measurement resolution.
7. Efficiency measured with all outputs at full load.
8. Maximum power dissipation when all outputs are shorted simultaneously.
9. Recovery time is measured from application of the transient to point at which VOUT is within 1% of VOUT at final value
10. Transition time >10 µs.
11. Half load to/from full load.
12. The Step Load specification for the negative auxiliary output is guaranteed by qualification test. It is not an in-line test.
13. Measured from release of inhibit or input voltage step.
14. Applies to each auxiliary. www.craneae.com/interpoint
Page 28 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
Single Output Representative PlotS
Typical Performance Plots: Vin as specified, 25°C case, 100% load, free run, unless otherwise
These are examples for reference only and are not guaranteed specifications.
Emission Level (dB µA)
90
NARROWBAND
CE
03
70
LIM
IT
50
30
10
.015
0.1
10
1
Frequency (MHz), 28 Vin
50
SMRT Single MIL-STD-461C, CE03
Figure 8
Emission Level (dB µV)
100
CE1
02 A
80
Ca
nd D
CL
imit
s
60
40
20
.01
0.1
1
10
Frequency (MHz), 28 Vin
SMRT Single MIL-STD-461 D-F, CE102
Figure 9
0.0
Audio Rejection (dB)
-20.0
-40.0
-60.0
-80.0
-100.0
100
-34.3 dB
1k
10 k
Frequency (Hz), 28 Vin
SMRT Single Audio Rejection
Figure 10
www.craneae.com/interpoint
Page 29 of 44
SMRT28 Rev AH - 2015.02.20
100 k
specified.
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
Single Output Representative PlotS
100 mV/div
Vout
20 V/div
Vin
Vin
100 mV/div
20 V/div
Typical Performance Plots: Vin as specified, 25°C case, 100% load, free run, unless otherwise
These are examples for reference only and are not guaranteed specifications.
Vout
100 µs/div
100 µs/div
Vin 56 to 19 V, full resistive load
Vin 19 TO 56 V, full resistive load
SMRT2805S Representative of Single Output Line Transient
SMRT2805S Representative of Single Output Line Transient
Figure 12
100 mV/div
100 mV/div
Figure 11
1 ms/div
1 ms/div
Load 50 - 100 - 50%, 28 Vin
Load 50 - 100 - 50%, 50 Vin
SMRT2805S Representative of Single Output Load Transient
SMRT2805S Representative of Single Output Load Transient
Figure 14
20 V/div
Figure 13
20 V/div
specified.
Vin
Vin
Vout
2 V/div
2 V/div
Vout
4 ms/div
4 ms/div
Full resistive load, 28 Vin
Full resistive load, 50 Vin
SMRT2805S Representative of Single Turn On Delay
Figure 15
www.craneae.com/interpoint
SMRT2805S Representative of Single Turn On Delay
Figure 16
Page 30 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
Single Output Efficiency and Gain Phase, All Models
Typical Performance Plots: Vin as specified, 25°C case, 100% load, free run, unless otherwise
These are examples for reference only and are not guaranteed specifications.
specified.
Efficiency
180.0
GAIN
30.0
Gain (dB)
58
GAIN (dB)
56
54
52
90.0
10.0
45.0
0.0
PHASE
-10.0
-20.0
10
15
20
M1
3.0 kHz
0.1 dB
72.7 deg
-30.0
25
-40.0
Vin=19
Vin=28
Vin=50
Vin=56
Output
Power
(Watts)
-50.0
100
50.0
28 V
180.0
GAIN
30.0
50 V
135.0
20.0
56 V
GAIN (dB)
Gain (dB)
Efficiency (%)
225.0
40.0
70
60
90.0
10.0
45.0
0.0
PHASE
-10.0
-30.0
-40.0
5
10
15
20
25
30
-50.0
Output Power (Watts)
Vin=19
Vin=28
Vin=50
Vin=56
Output
Power
(Watts)
0.0
-45.0
M1
4.9 kHz
-0.1 dB
72.4 deg
-20.0
55
50
-225.0
M2
Figure 18
Efficiency
19 V
-180.0
Frequency (Hz), 28 Vin
Figure 17
65
-135.0
SMRT283R3S Gain Phase
SMRT283R3S Efficiency
75
10 k
-45.0
-90.0
M2
19.5 kHz
-13.4 dB
0.1 deg
M1
1k
0.0
100
M2
18.9 kHz
-14.1 dB
0.2 deg
M1
1k
10 k
PHASE (deg)
5
Output Power (Watts)
Efficiency (%)
135.0
20.0
PHASE (deg)
56 V
50 V
19 V
60
50
225.0
40.0
62
Efficiency (%)
Efficiency (%)
50.0
Phase (deg)
28 V
64
Phase (deg)
66
-90.0
-135.0
-180.0
-225.0
M2
Frequency (Hz), 28 Vin
SMRT2805S Efficiency
SMRT2805S Gain Phase
Figure 19
Figure 20
Efficiency
70
19 V
180.0
GAIN (dB)
60
55
10
15
20
25
30
45.0
0.0
0.0
PHASE
-10.0
Vin=19
Vin=28
Vin=50
35
M1
1.7 kHz
0.1 dB
76.2 deg
-30.0
-40.0
Output Power (Watts)
-50.0
100
1k
M1
Frequency (Hz), 28 Vin
SMRT288R7S Efficiency
-135.0
-180.0
M2
10 k
SMRT288R7S Gain Phase
Figure 21
Figure 22
Page 31 of 44
SMRT28 Rev AH - 2015.02.20
-45.0
-90.0
M2
13.5 kHz
-17.3 dB
0.0 deg
Vin=56
Output Power (Watts)
www.craneae.com/interpoint
90.0
10.0
-20.0
5
135.0
GAIN
20.0
65
50
225.0
40.0
30.0
56 V
50 V
Gain (dB)
Efficiency (%)
Efficiency (%)
75
50.0
PHASE (deg)
28 V
Phase (deg)
80
-225.0
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
Single Output Efficiency and Gain Phase, All Models
Typical Performance Plots: Vin as specified, 25°C case, 100% load, free run, unless otherwise
These are examples for reference only and are not guaranteed specifications.
specified.
Efficiency
50 V
19 V
GAIN (dB)
60
55
10
15
45.0
0.0
PHASE
-10.0
20
25
30
35
Vin=19
Vin=28
Vin=50
M1
1.7 kHz
-0.0 dB
74.6 deg
-40.0
Vin=56
Output Power (Watts)
-50.0
100
1k
28 V
50 V
56 V
65
60
225.0
180.0
-30.0
20
25
30
Output Power (Watts)
Vin=19
Vin=28
Vin=50
Vin=56
Output Power (Watts)
35
45.0
0.0
PHASE
-10.0
50
15
-40.0
-50.0
100
M2
14.4 kHz
27.2 dB
0.1 deg
M1
1k
Frequency (Hz), 28 Vin
-135.0
-180.0
10 k
SMRT2815S Gain Phase
Figure 25
Figure 26
Page 32 of 44
-45.0
-90.0
M1
821.1 Hz
0.0 dB
66.7 deg
SMRT2815S Efficiency
www.craneae.com/interpoint
90.0
0.0
-20.0
10
135.0
GAIN
10.0
55
5
10 k
40.0
20.0
Gain (dB)
Efficiency (%)
Efficiency (%)
70
-225.0
M2
50.0
30.0
19 V
-180.0
Figure 24
Efficiency
75
M1
-135.0
SMRT2812S Gain Phase
Figure 23
80
-90.0
M2
9.6 kHz
-16.2 dB
0.1 deg
Frequency (Hz), 28 Vin
SMRT2812S Efficiency
85
0.0
-45.0
-30.0
Output Power (Watts)
90.0
10.0
-20.0
5
135.0
GAIN
20.0
65
50
180.0
SMRT28 Rev AH - 2015.02.20
M2
-225.0
Phase (deg)
70
225.0
40.0
30.0
56 V
Gain (dB)
Efficiency (%)
Efficiency (%)
75
50.0
PHASE (deg)
28 V
Phase (deg)
80
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
Dual Output Representative PlotS
Typical Performance Plots: Vin as specified, 25°C case, 100% load, free run, unless otherwise
These are examples for reference only and are not guaranteed specifications.
Emission Level (dB µA)
90
70
specified.
NARROWBAND
CE
03
LIM
IT
50
30
10
.015
0.1
1
Frequency (MHz), 28 Vin
10
50
SMRT Dual MIL-STD-461C, CE03
Figure 27
Emission Level (dB µV)
100
CE1
02 A
80
Ca
nd D
CL
imit
s
60
40
20
.01
0.1
1
10
Frequency (MHz), 28 Vin
SMRT Dual MIL-STD-461 D-F, CE102
0.0
0.0
-20.0
-20.0
Audio Rejection (dB)
Audio Rejection (dB)
Figure 28
-40.0
-60.0
-80.0
-100.0
100
1k
-20.0 dB
10 k
-40.0
-60.0
-80.0
-100.0
100 k
100
Frequency (Hz), 28 Vin
10 k
Frequency (Hz), 28 Vin
SMRT Dual Audio Rejection, Vout A
SMRT Dual Audio Rejection, Vout B
Figure 29
www.craneae.com/interpoint
-21.6 dB
1k
Figure 30
Page 33 of 44
SMRT28 Rev AH - 2015.02.20
100 k
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
Dual Output Representative PlotS
20 V/div
Vin
Vout A
200 mV/div
200 mV/div
20 V/div
Typical Performance Plots: Vin as specified, 25°C case, 100% load, free run, unless otherwise
These are examples for reference only and are not guaranteed specifications.
Vout B
Vin
Vout A
Vout B
100 µs/div
100 µs/div
Vin 19 to 56 V, full resistive load
SMRT2812D Representative of Dual Output Line Transient
Figure 31
Vin 56 to 19 V, full resistive load
SMRT2812D Representative of Dual Output Line Transient
Figure 32
Vout A
200 mV/div
200 mV/div
Vout A
Vout B
Vout B
1 ms/div
1 ms/div
Load 50 - 100 - 50%, 28 Vin
SMRT2812D Representative of Dual Output Load Transient
Load 50 - 100 - 50%, 50 Vin
SMRT2812D Representative of Dual Output Load Transient
Figure 34
20 V/div
20 V/div
Figure 33
Vin
Vin
Vout A
5 V/div
5 V/div
Vout A
Vout B
4 ms/div
Vout B
4 ms/div
Full resistive load, 28 Vin
Full resistive load, 50 Vin
SMRT2812D Representative of Dual Turn On Delay
SMRT2812D Representative of Dual Turn On Delay
Figure 35
www.craneae.com/interpoint
specified.
Figure 36
Page 34 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
Dual Output Efficiency and Gain Phase, All Models
Typical Performance Plots: Vin as specified, 25°C case, 100% load, free run, unless otherwise
These are examples for reference only and are not guaranteed specifications.
specified.
Efficiency
50.0
50 V
19 V
65
180.0
GAIN
30.0
56 V
(dB)
Gain
GAIN (dB)
Efficiency (%)
Efficiency (%)
70
225.0
40.0
60
55
135.0
20.0
90.0
10.0
45.0
0.0
PHASE
-10.0
M1
5.0 kHz
0.1 dB
78.9 deg
-20.0
50
5
10
15
20
25
-30.0
30
-40.0
Output Power (Watts)
Vin=19
Vin=28
Vin=50
Vin=56
-50.0
Output Power (Watts)
100
M2
20.8 kHz
-11.8 dB
-0.0 deg
M1
1k
-45.0
-90.0
-135.0
-180.0
-225.0
M2
10 k
0.0
PHASE (deg)
28 V
Phase (deg)
75
Frequency (Hz), 28 Vin
SMRT2805D Efficiency
SMRT2805D Gain Phase
Figure 37
Figure 38
Efficiency
50.0
56 V
50 V
19 V
65
GAIN (dB)
60
55
50
135.0
20.0
90.0
10.0
45.0
0.0
PHASE
-10.0
-45.0
M1
6.7 kHz
-0.3 dB
49.4 deg
-20.0
-30.0
5
10
15
20
25
30
35
-40.0
Output Power (Watts)
Vin=19
Vin=28
Vin=50
M2
13.5 kHz
-8.6 dB
-0.1 deg
-50.0
Vin=56
Output Power (Watts)
0.0
100
-90.0
-135.0
-180.0
M1
1k
PHASE (deg)
70
180.0
GAIN
30.0
Gain (dB)
Efficiency (%)
Efficiency (%)
75
225.0
40.0
28 V
Phase (deg)
80
-225.0
M2
10 k
Frequency (Hz), 28 Vin
SMRT2812D Efficiency
SMRT2812D Gain Phase
Figure 40
Figure 39
Efficiency
70
56 V
50 V
19 V
GAIN (dB)
65
60
55
50
180.0
30.0
Gain (dB)
Efficiency (%)
75
225.0
40.0
135.0
GAIN
20.0
90.0
10.0
45.0
0.0
0.0
PHASE
-10.0
M1
4.7 kHz
-0.1 dB
60.2 deg
-20.0
5
10
15
20
25
30
-30.0
35
-40.0
Output Power (Watts)
Vin=19
Vin=28
Vin=50
Vin=56
-50.0
Output Power (Watts)
100
M1
Frequency (Hz), 28 Vin
SMRT2815D Efficiency
10 k
SMRT2815D Gain Phase
Figure 41
www.craneae.com/interpoint
1k
M2
15.4 kHz
-13.8 dB
0.2 deg
Figure 42
Page 35 of 44
SMRT28 Rev AH - 2015.02.20
-45.0
PHASE (deg)
80
Efficiency (%)
50.0
28 V
-90.0
-135.0
-180.0
M2
Phase (deg)
85
-225.0
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
Triple Output Representative PlotS
Typical Performance Plots: Vin as specified, 25°C case, 100% load, free run, unless otherwise
These are examples for reference only and are not guaranteed specifications.
Emission Level (dB µA)
90
specified.
NARROWBAND
CE
03
70
LIM
IT
50
30
10
0.1
.015
10
1
Frequency (MHz), 28 Vin
50
SMRT Triple MIL-STD-461C, CE03
Figure 43
Emission Level (dB µV)
100
CE1
02 A
80
Ca
nd D
CL
imit
s
60
40
20
0.1
.01
1
10
Frequency (MHz), 28 Vin
SMRT Triple MIL-STD-461 D-F, CE102
0.0
0.0
-20.0
-20.0
Audio Rejection (dB)
Audio Rejection (dB)
Figure 44
-40.0
-60.0
-40.0
-60.0
-80.0
-80.0
-100.0
100
1k
10 k
-42.5 dB
-100.0
100 k
100
Frequency (Hz), 28 Vin
10 k
Frequency (Hz), 28 Vin
SMRT Triple Audio Rejection, Main
SMRT Triple Audio Rejection, +Aux
Figure 45
www.craneae.com/interpoint
-34.9 dB
1k
Figure 46
Page 36 of 44
SMRT28 Rev AH - 2015.02.20
100 k
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
TRiple Output Representative PlotS
100 mV/div
Vin
200 mV/div
+Aux
+Aux
Main
20 V/div
+Aux
10 V/div
+Aux
-Aux
1 ms/div
Vin
2 V/div
Main
2 V/div
-Aux
Figure 49
Vin
10 V/div
+Aux
Load 50 - 100 - 50%, 28 Vin
SMRT283R312T Representative
of Triple Output Load Transient
Figure 48
20 V/div
100 mV/div
Main
500 mV/div
1 ms/div
SMRT283R312T Representative
of Triple Output Line Transient
Figure 47
-Aux
4 ms/div
4 ms/div
Load 50 - 100 - 50%, 50 Vin
Full resistive load, 28 Vin
Full resistive load, 50 Vin
SMRT283R312T Representative
of Triple Output Load Transient
SMRT283R312T Representative
of Triple Output Turn On Delay
SMRT283R312T Representative
of Triple Output Turn On Delay
Figure 50
Figure 51
-Aux Voltage Change (%)
1.0%
0.0%
-1.0%
-2.0%
-3.0%
-4.0%
-5.0%
20%
-Aux 20% to 80% +Aux 20% fixed
30%
40%
50%
60%
70%
80%
Aux Load (%)
-55 C
25 C
125 C
-55 C
25 C
125 C
+Aux Load (%), 28 Vin
-55°C 25°C 125°C
SMRT283R312T Cross Regulation
Figure 53
www.craneae.com/interpoint
Cross Regulation
(Vin = 28 Volts)
3.0%
-Aux 20% fixed, +Aux 20% to 80%
8.0%
6.0%
-Aux Voltage Change (%)
-Aux 20% fixed, +Aux 20% to 80%
-Aux Voltage Change (%)
2.0%
10.0%
4.0%
2.0%
0.0%
-2.0%
-4.0%
-6.0%
-8.0%
20%
-Aux 20% to 80% +Aux 20% fixed
30%
40%
50%
60%
70%
80%
-Aux 20% fixed, +Aux 20% to 80%
2.0%
1.0%
-Aux Voltage Change (%)
!"#$%&%'(%")*+,-%
3.0%
Figure 52
Cross Regulation
(Vin = 28 Volts)
Cross Regulation
4.0%
-Aux Voltage Change (%)
-Aux
Vin 56 to 19 V, full resistive load
Vin 19 to 56 V, full resistive load
SMRT283R312T Representative
of Triple Output Line Transient
-Aux Voltage Change (%)
+Aux
100 µs/div
100 µs/div
specified.
Main
500 mV/div
Main
Main
200 mV/div
Vin
20 V/div
20 V/div
Typical Performance Plots: Vin as specified, 25°C case, 100% load, free run, unless otherwise
These are examples for reference only and are not guaranteed specifications.
0.0%
-1.0%
-2.0%
-3.0%
-4.0%
20%
-Aux 20% to 80% +Aux 20% fixed
30%
40%
Aux Load (%)
-55 C
25 C
125 C
50%
60%
70%
Aux Load (%)
-55 C
25 C
125 C
+Aux Load (%), 28 Vin
-55°C 25°C 125°C
SMRT28507T Cross Regulation
Figure 54
Page 37 of 44
SMRT28 Rev AH - 2015.02.20
-55 C
25 C
125 C
-55 C
25 C
125 C
+Aux Load (%), 28 Vin
-55°C 25°C 125°C
SMRT28515T Cross Regulation
Figure 55
80%
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
TRiple Output Representative PlotS
Typical Performance Plots: Vin as specified, 25°C case, 100% load, free run, unless otherwise
These are examples for reference only and are not guaranteed specifications.
specified.
Efficiency
75
28 V
Efficiency (%)
Efficiency (%)
70
56 V
50 V
19 V
65
60
55
50
5
10
15
20
25
30
Output Power (Watts)
Vin=19
Vin=28
Vin=50
Vin=56
Output Power (Watts)
SMRT283R312T Efficiency
Figure 56
50.0
225.0
180.0
40.0
180.0
135.0
30.0
20.0
90.0
20.0
10.0
45.0
-45.0
-10.0
-20.0
M1
3.1 kHz
-0.0 dB
74.9 deg
-30.0
-40.0
-50.0
100
1k
M2
22.7 kHz
-13.7 dB
0.1 deg
M1
10 k
M2
45.0
0.0
PHASE
-10.0
-90.0
-20.0
-135.0
-30.0
-180.0
-40.0
-225.0
-50.0
100
Frequency (Hz), 28 Vin
M2
19.2 kHz
-29.5 dB
0.1 deg
M1
1k
Figure 58
Page 38 of 44
SMRT28 Rev AH - 2015.02.20
-45.0
10 k
-135.0
-180.0
M2
SMRT283R312T Gain Phase, +Aux
Representative of all 12 V +Aux models
Figure 57
0.0
-90.0
M1
1.0 kHz
0.0 dB
69.5 deg
Frequency (Hz), 28 Vin
SMRT283R312T Gain Phase, Main Vout
Representative of all 3.3 V Main models
www.craneae.com/interpoint
90.0
10.0
-225.0
Phase (deg)
0.0
135.0
GAIN
Phase (deg)
Gain (dB)
PHASE
0.0
Gain (dB)
GAIN
30.0
Gain (dB)
225.0
40.0
Phase (deg)
50.0
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
TRiple Output Representative PlotS
Typical Performance Plots: Vin as specified, 25°C case, 100% load, free run, unless otherwise
These are examples for reference only and are not guaranteed specifications.
specified.
Efficiency
75
28 V
Efficiency (%)
Efficiency (%)
70
56 V
50 V
19 V
65
60
55
50
5
10
15
20
25
30
Output Power (Watts)
Vin=19
Vin=28
Vin=50
Vin=56
Output Power (Watts)
SMRT283R315T Efficiency
Figure 59
28 V
Gain (dB)
Efficiency (%)
Efficiency (%)
180.0
60
90.0
10.0
PHASE
0.0
-10.0
M1
2.1 kHz
-0.0 dB
76.9 deg
-30.0
50
5
10
15
20
25
-40.0
30
-50.0
Output Power (Watts)
Vin=19
Vin=28
Vin=50
Vin=56
Output Power (Watts)
100
1k
Figure 60
Figure 61
Efficiency
80
28 V
Efficiency (%)
Efficiency (%)
56 V
50 V
19 V
65
60
55
50
5
10
15
20
25
Output Power (Watts)
Vin=19
Vin=28
Vin=50
Vin=56
Output Power (Watts)
SMRT28512T Efficiency
Figure 62
www.craneae.com/interpoint
M1
10 k
-135.0
-180.0
M2
SMRT28507T Gain Phase, +Aux
70
Page 39 of 44
0.0
-90.0
M2
19.3 kHz
-19.1 dB
0.0 deg
Frequency (Hz), 28 Vin
SMRT28507T Efficiency
75
45.0
-45.0
-20.0
55
135.0
GAIN
20.0
56 V
50 V
19 V
225.0
40.0
30.0
70
65
50.0
SMRT28 Rev AH - 2015.02.20
30
-225.0
Phase (deg)
Efficiency
75
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
TRiple Output Representative PlotS
Typical Performance Plots: Vin as specified, 25°C case, 100% load, free run, unless otherwise
These are examples for reference only and are not guaranteed specifications.
specified.
Efficiency
80
28 V
75
Efficiency (%)
Efficiency (%)
70
56 V
50 V
19 V
65
60
55
50
5
10
15
20
25
30
Output Power (Watts)
Vin=19
Vin=28
Vin=50
Vin=56
Output Power (Watts)
SMRT28515T Efficiency
Figure 63
50.0
225.0
180.0
40.0
180.0
30.0
135.0
30.0
90.0
20.0
Gain (dB)
10.0
45.0
PHASE
0.0
-10.0
0.0
-45.0
M1
6.0 kHz
-0.0 dB
67.6 deg
-20.0
-30.0
-40.0
-50.0
100
1k
M2
20.1 kHz
-10.7 dB
-0.1 deg
M1
10 k
M2
45.0
PHASE
0.0
-10.0
-20.0
-135.0
-30.0
-180.0
-40.0
-225.0
-50.0
-90.0
M1
750.7 Hz
0.0 dB
65.8 deg
100
M2
18.3 kHz
-31.9 dB
-0.2 deg
M1
1k
10 k
Frequency (Hz), 28 Vin
-135.0
-180.0
M2
SMRT28515T Gain Phase, +Aux
Representative of all 15 V +Aux models
Figure 64
Figure 65
Page 40 of 44
0.0
-45.0
SMRT28515T Gain Phase, Main Vout
Representative of all 5 V Main models
www.craneae.com/interpoint
90.0
10.0
-90.0
Frequency (Hz), 28 Vin
135.0
GAIN
SMRT28 Rev AH - 2015.02.20
-225.0
Phase (deg)
GAIN
20.0
Gain (dB)
225.0
40.0
Phase (deg)
50.0
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
19-56 Volt input – 35 Watt – Space qualified
BOTTOM VIEW CASE S
Seal hole: 0.135 ±0.005 (3.43 ±0.13)
Angled corner
indicates pin 1
6 x 0.135 (3.43) dia.
1.700 (43.18)
14
1
1.500 (38.10)
13
2
1.300 (33.02)
12
3
1.100 (27.94)
11
4
0.900 (22.86)
10
5
0.700 (17.78)
9
0.500 (12.70)
8
Case dimensions in inches (mm)
Tolerance ±0.005 (0.13) for three decimal places
±0.01 (0.3) for two decimal places
unless otherwise specified
CAUTION
Heat from reflow or wave soldering may damage the device.
Solder pins individually with heat application not exceeding 300°C for 10 seconds per pin
Materials
Header Cold Rolled Steel/Nickel
Cover
Kovar/Nickel
Pins
#52 alloy/gold, ceramic seal
Gold plating of 50 - 150 microinches included in pin diameter
Seal hole 0.123 ±0.002 (3.12 ±0.051)
Case S, Rev E, 2013.05.15
Please refer to the numerical dimensions for accuracy.
Figure 66: Case S
www.craneae.com/interpoint
Page 41 of 44
SMRT28 Rev AH - 2015.02.20
2.705 max (68.71)
2x 1.550 (39.37)
Weight: 100 gms maximum
2x 2.550 (64.77)
0.00
0.00
2x 0.150 (3.81)
0.220 (5.59)
0.050 (1.27)
0.00
0.400 max (10.16)
3x 0.125 (3.15)
0.262 (6.65)
12 x 0.040 ± 0.002 dia.
(1.02 ± 0.05)
12 x 0.270 max (6.86)
1.675 (42.5)
2.205 max (56.01)
3x 2.075 (52.68)
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
19-56 Volt input – 35 Watt – Space qualified
Tableisforreferenceonly.SeeindividualSeries'datasheetsforspecificscreening.
dc-dc conVerterS PrototyPe, claSS h and claSS K,
Mil-Prf-38534 eleMent eValuation
non-QMl 1
QMl
PrototyPe
/o
coMPonent-leVel teSt PerforMed
ElementElectrical
M/S
2
claSS h
M/S
n
2
/h
P
claSS K
3
M/S
2
/K
P3
n
n
n
n
Visual
n
n
n
n
InternalVisual
n
n
TemperatureCycling
n
n
ConstantAcceleration
n
n
InterimElectrical
n
Burn-in
n
PostBurn-inElectrical
n
SteadyStateLife
n
VoltageConditioningAging
n
VisualInspection
n
FinalElectrical
n
n
n
n
WireBondEvaluation
n
n
n
n
SEM
n
Notes
1.Non-QMLproductsmaynotmeetalloftherequirementsofMIL-PRF-38534.
2.M/S=Activecomponents(microcircuitandsemiconductordie)
3.P=Passivecomponents,ClassHandKelementevaluation.Notapplicabletospaceprototype(“O”)elementevaluation.
Definitions:
ElementEvaluation:Componenttesting/screeningperMIL-STD-883asdeterminedbyMIL-PRF-38534
SEM:ScanningElectronMicroscopy
table 1: eleMent eValuatIOn–dc-dc cOnVerterS prOtOtype, claSS h and claSS k
Table 27: Element Evaluation
www.craneae.com/interpoint
Page 42 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
19-56 Volt input – 35 Watt – Space qualified
Tableisforreferenceonly.SeeindividualSeries'datasheetsforspecificscreening.
dc-dc conVerterS PrototyPe, claSS h and claSS K
Mil-Prf-38534 enVironMental Screening and rha1 P or r
non-QMl 2
PrototyPe
teSt PerforMed
/oo
claSS K
/hP
/hr
/KP
/Kr
n4
n4
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n
n4
n4
n
n
n4
n4
n
n
n
n
non-destruct wire bond pull, Method 2023
pre-cap Inspection, Method 2017, 2032
claSS h
QMl 3
temperature Cycle (10 times) (Qual100times)
Method1010,Cond.C,-65°Cto+150°C,ambient
Constant acceleration
Method2001,3000g(Qual5000g)
pInD, test Method 2020, Cond. a
pre burn-in test, group a, subgroups 1 and 4
burn-in Method 1015, +125°C case, typical
n
5
96hours
n
160hours
n
n
2x160hours(includesmid-BItest)
Final electrical test, MIL-prF-38534, group a,
Subgroups1and4:+25°Ccase
n
Subgroups1through6,-55°C,+25°C,+125°Ccase
n
n
n
n
Hermeticity test
GrossLeak,Method1014,Cond.C
n
n
n
n
n
FineLeak,Method1014,Cond.A
n
n
n
n
n
radiography, Method 2012
n
n
post radiography electrical test, +25°C case
n4
n4
n
n
Final visual inspection, Method 2009
n
rHa p: 30 krad(si) total dose
n
n
rHa r: 100 krad(si) total dose
single event effect (see)
n
n
n
1
n
n
n
n
n
LinearEnergyTransfer(LET)86MeVcm2/mg
TestmethodsarereferencedtoMIL-STD-883asdeterminedbyMIL-PRF-38534.
Notes
1.OurRedmondfacilityhasaDLAapprovedRHAplanforInterpointpower
products.OurSMDproductswithRHA“P”or“R”codemeetDLArequirements.
2.“OO”prototypesarenon-QMLproductsandmaynotmeetalloftherequirements
ofMIL-PRF-38534.“O”intheRHAdesignatorpositioninInterpointmodel
numbersindicatesDLARHA“-”definedasnoRHA.
3.AllprocessesareQMLqualifiedandperformedbycertifiedoperators.
4.NotrequiredbyDLAbutperformedtoassureproductquality.
5.Burn-intemperaturedesignedtobringthecasetemperatureto+125°Cminimum.
Burn-inisapoweredtest.
Table 28: Environmental Screening and RHA Levels
table 2: enVIrOnMental ScreenIng and rha–dc-dc cOnVerterS prOtOtype, claSS h and claSS k, rha p Or r
See “Table 29: RHA Acronyms” on page 44
www.craneae.com/interpoint
Page 43 of 44
SMRT28 Rev AH - 2015.02.20
Crane Aerospace & Electronics Power Solutions
SMRT Single, Dual and Triple Space DC-DC Converters
19-56 Volt input – 35 Watt – Space qualified
Notes: For “Table 28: Environmental Screening and RHA Levels”
1. Our Redmond site has a DLA approved RHA plan for Interpoint power
products. Our SMD products with RHA “P” or “R” level meet DLA
requirements.
2. “OO” prototypes are non-QML products and may not meet all of the
requirements of MIL-PRF-38534. “O” in the RHA designator position in
Interpoint model numbers indicates DLA RHA “-” defined as no RHA.
3. All processes are QML qualified and performed by certified operators.
4. Not required by DLA but performed to assure product quality.
5. Burn-in temperature designed to bring the case temperature to +125°C
minimum. Burn-in is a powered test.
6. High dose rate test.
7. Low dose rate test.
8. No SEGR, SEL or SEU. SET is within the transient limits as specified
in the Electrical Characteristic tables.
Acronym
Definition
HDR
high dose rate
LDR
low dose rate
LET
linear energy transfer
MeV
million electron volts
RHA
radiation hardness assurance
SEE
single event effect
SEGR
single event gate rupture
SEL
single event latch-up
SET
single event transient
SEU
single event upset
TID
total ionizing dose
Table 29: RHA Acronyms
SMRT28 Single, Dual and Triple SMRT28 Rev AH - 2015.02.20. This revision supersedes all previous releases. All technical information is believed
to be accurate, but no responsibility is assumed for errors or omissions. Crane Electronics, Inc reserves the right to make changes in products
or specifications without notice. Interpoint is a registered trademark of Crane Co. and SMRT Series is a trademark of Crane Electronics, Inc. Copyright © 1999-2015 Crane Electronics, Inc. All rights reserved. www.craneae.com/interpoint
Page 44 of 44