MA-COM MD-160

MD-160
Termination-Insensitive Mixer,
1 - 1500 MHz
Features
n
n
n
n
n
n
V 3.00
RH-3
Third Order Intermodulation Ratio is Insensitive to Port
Mismatches
Conversion Loss: 7 dB Typical Midband
VSWR: Typically Less than 1.5:1 @ Midband
Impedance: 50 Ohms Nominal
Maximum Input Power: 350 mW max. @ 25°C,
Derated to 85°C @ 3.5 mW/°C
MIL-STD-883 Screening Available
Description
The unique design of the termination insensitive mixer
(TIM) enables it to apply high reverse voltage to diodes
during their “off” phase, in the LO cycle. This allows for
higher power level performance with minimum distortion.
In addition the TIM has internal loads that provide a good
match and also absorb mixer generated LO frequency
terms. Combined, these features give the mixer its
insensitivity to external mismatches, plus superior VSWR.
Pin Configuration
Pin No.
Function
Pin No.
Function
1
LO
5
GND
2
GND
6
GND
3*
IF
7*
IF
4
GND
8
RF
* P3 and P7 are connected together to make IF Port.
Electrical Specifications1: TA = -55°C to +85°C
Parameter
Test Conditions
Frequency
Units
Min
Typ
Max
Frequency Range
RF, LO Ports
IF Port (3 dB BW)
1 - 1500
1 - 1000
MHz
MHz
—
—
—
—
—
—
5 - 1000 MHz
1 - 1500 MHz
dB
dB
—
—
—
—
7.5
9.0
LO to RF
1 - 5 MHz
5 - 500 MHz
500 - 1500 MHz
dB
dB
dB
20
28
25
—
—
—
—
—
—
LO to IF
1 - 5 MHz
5 - 500 MHz
500 - 1500 MHz
dB
dB
dB
20
28
17
—
—
—
—
—
—
RF to IF
1 - 5 MHz
5 - 500 MHz
500 - 1500 MHz
dB
dB
dB
20
25
17
—
—
—
—
—
—
dBm
dBm
—
—
+15
+13
—
—
Conversion Loss 2
Isolation
RF Input
1 dB Compression 3
1 dB Desensitization 3
1. All specifications apply when operated at +13 dBm available LO power with 50 ohm source and load impedance.
2. For IF Frequencies of 5 - 1000 MHz and an RF of –10 dBm or lower.
3. These characteristics apply @ +20 dBm LO power.
This product contains elements protected by United States Patent Number 4,224,572.
Termination-Insensitive Mixer, 1 - 1500 MHz
MD-160
V 3.00
Electrical Specifications: TA = -55°C to +85°C
Parameter
Test Conditions
Frequency
Units
Min
Typ
Max
SSB Noise Figure
Within 1 dB of Conversion Loss
Max.
—
—
—
—
—
3rd Order Input
Intercept
PLO +13 dBm
15 MHz
500 MHz
1000 MHz
dBm
dBm
dBm
—
—
—
+18
+20
+19
—
—
—
PLO +20 dBm
15 MHz
500 MHz
1000 MHz
dBm
dBm
dBm
—
—
—
+23
+25
+25
—
—
—
@ IF VSWR 3.0:1
—
dB
—
3
—
3rd Order Intercept
Degradation
Typical Performance Curves
Isolation
Conversion Loss
+6 dBm
+8 dBm
+10 dBm
+13 dBm
+20 dBm
L-R
L-X
10
40
9
8
7
30
20
6
10
5
0.5
5.0
50.0
500.0
1000.0
1500.0
0.5
2000.0
5.0
13 dBm
500.0
1000.0
1500.0
2000.0
3rd Order intercept vs. IF Port
Termination
3rd Order Intercept
10 dBm
50.0
Frequency (MHz)
Frequency (MHz)
17 dBm
50 Ohm
+10 dBm LO
20 dBm
30
3.0:1 VSWR
30
3rd Order Intercept (dBm)
3rd Order Intercept (dBm)
R-X
50
Isolation (dB)
Conversion Loss (dB)
11
25
20
25
20
15
15
0.5
5.0
50.0
500.0
1000.0
1500.0
2000.0
Frequency (MHz)
Specifications subject to change without notice.
n North America: Tel. (800) 366-2266
n Asia/Pacific: Tel.+81-44-844-8296, Fax +81-44-844-8298
n Europe: Tel. +44 (1344) 869 595, Fax+44 (1344) 300 020
Visit www.macom.com for additional data sheets and product information.
0.5
5.0
50.0
500.0
1000.0
1500.0
2000.0
Frequency (MHz)
2
Termination-Insensitive Mixer, 1 - 1500 MHz
MD-160
V 3.00
Typical Performance Curves
VSWR
IF Port Response
3.0
3
2.5
VSWR
Relative Response (dB)
LO
4
2
IF
RF
2.0
1.5
1
0
1.0
0.5
5.0
50.0
500.0
1000.0
1500.0
2000.0
Frequency (MHz)
0.5
5.0
50.0
500.0
1000.0
1500.0
2000.0
Frequency (MHz)
Ordering Information
Part Number
Package
MD-160 PIN
RH-3
Specifications subject to change without notice.
n North America: Tel. (800) 366-2266
n Asia/Pacific: Tel.+81-44-844-8296, Fax +81-44-844-8298
n Europe: Tel. +44 (1344) 869 595, Fax+44 (1344) 300 020
Visit www.macom.com for additional data sheets and product information.
3