UCAP16-58 ULTRACAPACITOR MODULE

UCAP16-58
ULTRACAPACITOR MODULE
The Intronics Power Inc. UCAP16-58 Ultracapacitor Module is a versatile high power
energy storage subsystem with applications in many fields.
FEATURES
� Consists of six series connected 350 Farad
ultracapacitors
� Includes individual cell balancing circuitry
� Operating Temperature Range -40 to +65
degrees C
� 5800 watt max surge power
� High current capability printed circuit board
� High current screw connector
APPLICATIONS
�
�
�
�
�
�
�
�
Remote site monitoring
Solar energy storage
Battery augmentation
Vehicle electrical system stabilization
Regenerative energy capture
Solar powered electric gates
Remote weather stations
Highway emergency telephones and signage
1400 PROVIDENCE HIGHWAY •
BUILDING 2 NORWOOD,
MASSACHUSETTS 02062-5015
PHONE: 781-551-5500 FAX: 781-551-5555
GENERAL
Ultracapacitors are similar to other capacitors, except
they have much greater capacitance, and are generally
rated at 2.7 volts or less. Therefore, they are generally
connected in series for higher voltage applications. To
ensure that each individual ultracapacitor in such a
series configuration is not charged above its rated
voltage, a cell balancing circuit is often included.
1/2C(V1²-V2²) . So for example, charging the module
to 16V and discharging it to 11V will mean the storage
and release of 4313 joules. So discharging only 31%of
the stored voltage releases 55% of the stored energy.
BALANCING CIRCUIT
The balancing circuit consists of high efficiency LED
in series with a silicon diode connected across each
ultracapacitor in the module. The exponential forward
OVERVIEW
VI characteristics of the LED and diode leaks current at
approximately 20 mA from any ultracapacitor in the
The Intronics UCAP16-58 module consists of six
module when its voltage approaches its maximum
series connected 350 farad ultracapacitors with
rating of 2.7V. If the external power source can deliver
individual cell balancing circuitry. This module is
more than 20 mA to the module, some form of external
intended for use as part of larger systems where reliable
voltage limiting will be necessary. The balancing
energy storage is essential.
circuit will only balance the voltage between
ultracapacitors in the module. It will not limit the
Ultracapacitors are similar to other capacitors, except
module voltage.
they have much greater capacitance, and are generally
Another benefit of the balancing circuit design is that
rated at 2.7 volts or less. Therefore, they are generally
the LEDs in the circuit will give a rough indication of
connected in series for higher voltage applications. To
the charge state of the module. If the LEDs are bright,
ensure that each individual ultracapacitor in such a
the module is fully charged. If they are dim, it is above
series configuration is not charged above its rated
approximately 12V. If one or more LED is significantly
voltage, a cell balancing circuit is often included.
different from the others, it may indicate a failed or
marginal ultracapacitor.
The printed circuit board has extra thick (4oz) copper
and high current screw type terminals. It can be used
SELF DISCHARGE
with solder connections, ring terminals and screws, as
well as the high current screw terminal connector.
The balancing circuit is designed to leak current from
each individual ultracapacitor as its voltage approaches
the its maximum rated voltage of 2.7V. Thus,
ENERGY STORAGE
ultracapacitors that are higher charged will leak more
than ultracapacitors that are less charged, thus
This module has a capacitance of 58.3 farads at a
balancing the total module voltage equally between all
maximum rated voltage of 16.4V. The stored energy of
the ultracapacitors in the module. As the ultracapacitor
a capacitor is 1/2CV² , so if fully charged to 16.4V, this
voltage decreases, the leakage falls off rapidly,
module will store 7840 joules (watt seconds). If
becoming less than 1% per day when the module
charged to one voltage (V1) and discharged to a lower
voltage is under 13.4V (Chart 2).
voltage (V2), the stored and released voltage is the
difference between 1/2C(V1)² and 1/2C(V2)² or
1400 PROVIDENCE HIGHWAY •
BUILDING 2 NORWOOD,
MASSACHUSETTS 02062-5015
PHONE: 781-551-5500 FAX: 781-551-5555
NORMAL OPERATING CONDITIONS
SPECIFICATIONS
Voltage 0-16.4V
Max Continuous Current 21 Amps RMS
Max Peak Current (1 second, non repetitive) 220
Amps
Storage Temperature Range -40 to +70 degrees C
Operating Temperature Range -40 to +65 degrees C
Stored energy 7650 joules (2.12 WH)
Max Output Power 5856 Watts
Dimensions 5” x 3.1” x 2.7” high
Weight 1.0 lb (.45 Kg)
ABSOLUTE MAXIMUM RATINGS
Maximum Voltage
17.1V
Maximum Short Circuit Current
840 Amps
CONNECTIONS
Connector Wire Entry .216” x. 225” (Accepts #4
AWG wire)
PCB Wire Solder Hole .100” dia (accepts #10 AWG
wire)
PCB Terminal Lug Hole .193” dia (accepts #10
screw)
% loss per day VS days
PHYSICAL
2.00%
1.80%
1.60%
1.40%
PCB Copper Laminate 4 oz/sq ft
PCB Mounting Holes 4 X .193” dia (accept #10
screw)
Dimensions 5” x 2.8” x 2.7” high
Weight 1.0 lb (.45 Kg)
1.20%
1.00%
0.80%
0.60%
0.40%
0.20%
0.00%
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41
43
45
47
49
51
Module Voltage VS Days
% Voltage loss per day VS Module Voltage
18
16.00%
16
14.00%
14
12.00%
12
10
Volts
8.00%
Volts
10.00%
8
6.00%
4.00%
2.00%
0.00%
18
16
14
12
10
8
6
4
2
6
4
2
0
MODULE VOLTAGE
0
1
2
3
4
5
6
7
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56
Days
1400 PROVIDENCE HIGHWAY • BUILDING 2
NORWOOD, MASSACHUSETTS 02062-5015
PHONE: 781-551-5500 FAX: 781-551-5555