©TOKYO-SKYTREE FEATURES HF cables are noted for the following features: Super flexibility, for installation. Larger average power rating. Smaller attenuation value. Customized cable length available. Excellent V.S.W.R. Light weight and easy handling. Due to its corrugated outer conductor, can handle external pressure on. Cable uses its own unique oxygen-free copper to create copper Toughlex, as the outer conductor. Connector Inner conductor Insulator Outer conductor Jacket HFcable 2 APPLICATION Broadcasting Mainly used as the main and branch feeders for transmission. (a) Medium-wave, short-wave radio broadcasting (b) FM radio broadcasting (c) VHF-TV broadcasting (d) UHF-TV broadcasting General use (a) Radar equipment (b) Antenna feeder (c) Microwave relay installation 3 HF-203D-S 8" Air dielectric coaxial cable Structure Item Diameter (mm) Materials Inner conductor 89.1 Corrugated copper Insulator 196 PFA Outer conductor 215 Corrugated copper Jacket 226 Polyethylene, Black Mechanical Characteristics Item Specification Cable weight 15 kg/m Minimum bending radius Single 1700 mm Repeated 2500 mm Tensile strength 4700 N Flat plate crush strength 5000 N/50mm Amb. 40℃ Electrical Characteristics Item Specification Impedance 50 Ω Velocity 96 % Direct current resistance (Loop resistance) 16 mΩ/100m Insulation resistance 1000 MΩ-km Peak voltage 20000 V Peak power rating 4000 kW Jacket spark 8000 V RMS Maximum frequency 650 MHz V.S.W.R. Frequency range (MHz) Specified channel Specified band ( *1) Within range 10 - 30 - 1.07 - 30 - 230 1.05 1.10 1.15 230 - 470 - 1.10 - 470 - 650 1.05 1.10 1.15 0.5 0.011 4000 4000 1 0.015 4000 4000 10 0.048 1395 1270 30 0.085 785 715 50 0.115 600 545 100 0.168 412 375 200 0.252 280 255 300 0.321 222 201 400 0.391 187 170 500 0.461 163 148 600 0.531 147 133 650 0.55 138 125 Condition 1) Attenuation • Ambient temperature 20ºC, Nominal value 2) Average power • Ambient temperature 40℃ & 50ºC • Inner conductor temperature 150ºC • V.S.W.R.=1.0 *1: Less than 30MHz band 1.6 1.4 Accessories 1.2 - Structure Type Female flange Gas through 203D-WFP-10FS Female flange Gas barrier 203D-WFS-11FS Factor (K) Connector/Flange type Standard Amb. 50℃ Frequency Attenuation Average power Average power (MHz) (dB/100m) (kW) (kW) 1 0.8 0.6 0.4 0.2 0 0 20 40 60 Temperature Factor (K) of Ambient temperature and Average power P=PoxK Po: Ambient temperature 40℃ & 50ºC P: Ambient temperature TºC K: Factor K=(150-T)/110 Po=40℃ (Blue line) K=(150-T)/100 Po=50℃ (Red line) 4 80 100 HF-152D 6-1/8" Air dielectric coaxial cable Structure Item Diameter (mm) Materials Inner conductor 66.7 Corrugated copper Insulator 147 Polyethylene Outer conductor 162 Corrugated copper Jacket 174 Polyethylene, Black Mechanical Characteristics Item Specification Cable weight 9.1 kg/m Minimum bending radius Single 1200 mm Repeated 2000 mm Tensile strength Flat plate crush strength 5000 N 5000 N/50mm Amb. 40℃ Item Specification Impedance 50 Ω Velocity 96 % Amb. 50℃ Frequency Attenuation Average power Average power (MHz) (dB/100m) (kW) (kW) Electrical Characteristics 0.5 0.013 2505 2170 1 0.0185 1770 1530 10 0.058 550 480 30 0.11 315 275 50 0.135 244 210 100 0.19 171 148 200 0.275 120 104 Direct current resistance (Loop resistance) 23 mΩ/100m Insulation resistance 1000 MΩ-km Peak voltage 17000 V Peak power rating 2890 kW 300 0.34 97.0 84.0 Jacket spark 8000 V RMS 400 0.395 83.5 72.5 Maximum frequency 860 MHz 500 0.45 74.5 64.5 600 0.495 68.0 59.0 700 0.54 63.0 54.5 800 0.58 58.5 51.0 850 0.6 56.5 49.5 V.S.W.R. Frequency range (MHz) Specified channel Specified band (*1) Within range 10 - 30 - 1.05 - 30 - 230 1.05 1.05 1.10 230 - 470 - 1.10 - 470 - 770 1.05 1.05 1.10 770 - 850 1.05 1.10 1.15 Condition 1) Attenuation • Ambient temperature 20ºC, Nominal value 2) Average power • Ambient temperature 40℃ & 50ºC • Inner conductor temperature 115ºC • V.S.W.R.=1.0 *1: Less than 30MHz band 2 1.8 Accessories 1.6 Connector/Flange type EIA 6-1/8" JEITA BFX-152D 1.4 Structure Type Female flange Gas through 152D-EFP-11FS Female flange Gas barrier 152D-EFS-11FS Male flange Gas through 152D-WMP-10FS Female flange Gas through 152D-WFP-10RS Coupling Gas barrier 152D-WGS-11NFS Factor (K) Standard 1.2 1 0.8 0.6 0.4 0.2 0 0 20 40 60 Temperature 80 100 Factor (K) of Ambient temperature and Average power P=PoxK Po: Ambient temperature 40℃ & 50ºC P: Ambient temperature TºC K: Factor K=(115-T)/75 Po=40℃ (Blue line) K=(115-T)/65 Po=50℃ (Red line) 5 HF-120D 5-1/2" Air dielectric coaxial cable Structure Item Diameter (mm) Materials Inner conductor 58 Corrugated copper Insulator 127 Polyethylene Outer conductor 140.5 Corrugated copper Jacket 148 Polyethylene, Black Mechanical Characteristics Item Specification Cable weight 7.8 kg/m Minimum bending radius Single 900 mm Repeated 1600 mm Tensile strength 3500 N Flat plate crush strength 3000 N/50mm Amb. 40℃ Electrical Characteristics Item Specification Impedance 50 Ω Velocity 96 % Direct current resistance (Loop resistance) 27 mΩ/100m Insulation resistance 1000 MΩ-km Peak voltage 15000 V Peak power rating 2250 kW Jacket spark 8000 V RMS Maximum frequency 950 MHz V.S.W.R. Frequency range (MHz) Specified channel Specified band ( *1) Within range 10 - 30 - 1.05 - 30 - 230 1.05 1.05 1.10 230 - 470 - 1.10 - 470 - 770 1.05 1.05 1.10 770 - 950 1.05 1.10 1.15 *1: Less than 30MHz band 0.5 0.015 1885 1635 1 0.0215 1330 1155 10 0.0675 415 360 30 0.12 240 208 50 0.155 185 160 100 0.22 130 112 200 0.315 91.0 78.5 300 0.39 74.0 64.0 400 0.455 64.0 55.5 500 0.515 57.0 49.5 600 0.57 52.0 45.0 700 0.62 48.5 42.0 800 0.665 45.5 39.0 900 0.715 42.5 37.0 950 0.74 41.5 36.0 Condition 1) Attenuation • Ambient temperature 20ºC, Nominal value 2) Average power • Ambient temperature 40ºC & 50ºC • Inner conductor temperature 115ºC • V.S.W.R.=1.0 2 Accessories 1.8 Connector / Flange type IEC 4-1/2" JEITA BFX-120D 1.6 Structure Type 1.4 1.2 Female flange Gas through 120D-105D-IFP-11FS Female flange Gas barrier 120D-105D-IFS-11FS Male flange Gas through 120D-WMP-10FS Female flange Gas through 120D-WFP-10RS Coupling Gas barrier 120D-WGS-11NFS Factor (K) Standard Amb. 50℃ Frequency Attenuation Average power Average power (MHz) (dB/100m) (kW) (kW) 1 0.8 0.6 0.4 0.2 0 0 20 40 60 Temperature Factor (K) of Ambient temperature and Average power P=PoxK Po: Ambient temperature 40ºC & 50ºC P: Ambient temperature TºC K: Factor K=(115-T)/75 Po=40℃ (Blue line) K=(115-T)/65 Po=50℃ (Red line) 6 80 100 HF-105D 5" Air dielectric coaxial cable Structure Item Diameter (mm) Materials Inner conductor 45 Corrugated copper Insulator 98 Polyethylene Outer conductor 109 Corrugated copper Jacket 117 Polyethylene, Black Mechanical Characteristics Item Specification Cable weight 4.85 kg/m Minimum bending radius Single 500 mm Repeated 1300 mm Tensile strength 3000 N Flat plate crush strength 3000 N/50mm Amb. 40℃ Electrical Characteristics Item Specification Impedance 50 Ω Velocity 96 % Direct current resistance (Loop resistance) 42 mΩ/100m Insulation resistance 1000 MΩ-km Peak voltage 12500 V Peak power rating 1560 kW Jacket spark 8000 V RMS Maximum frequency 1130 MHz V.S.W.R. Frequency range (MHz) Specified channel Specified band ( *1) Within range 10 - 30 - 1.05 - 30 - 230 1.05 1.05 1.10 230 - 470 - 1.10 - 470 - 770 1.05 1.05 1.10 770 - 960 1.05 1.10 1.15 *1: Less than 30MHz band 0.5 0.0195 1200 1040 1 0.028 848 735 10 0.088 266 230 30 0.155 153 132 50 0.2 118 102 100 0.285 82.5 71.5 200 0.41 58.0 50.0 300 0.505 47.0 40.5 400 0.585 40.5 35.0 500 0.66 36.0 31.5 600 0.73 33.0 28.5 700 0.79 30.5 26.5 800 0.85 28.5 24.5 900 0.91 26.5 23.0 1000 0.96 25.5 22.0 Condition 1) Attenuation • Ambient temperature 20ºC, Nominal value 2) Average power • Ambient temperature 40ºC & 50ºC • Inner conductor temperature 115ºC • V.S.W.R.=1.0 Accessories 2 Connector / Flange type EIA 6-1/8" IEC 4-1/2" EIA 3-1/8" JEITA BFX-120D JEITA BFX-77D 1.8 Structure 1.6 Type 1.4 Female flange Gas through 105D-152D-EFP-11FS Female flange Gas barrier 105D-152D-EFS-11FS Female flange Gas through 105D-IFP-11FS Female flange Gas barrier 105D-IFS-11FS 0.6 Female flange Gas through 105D-77D-EFP-11FS 0.4 Female flange Gas barrier 105D-77D-EFS-11FS Male flange Gas through 105D-120D-WMP-10FS Female flange Gas through 105D-120D-WFP-10RS Coupling Gas barrier 105D-120D-WGS-11NFS Male flange Gas through 105D-77D-WMP-10FS Female flange Gas through 105D-77D-WFP-10RS Coupling Gas barrier 105D-77D-WGS-11NFS Factor (K) Standard Amb. 50℃ Frequency Attenuation Average power Average power (MHz) (dB/100m) (kW) (kW) 1.2 1 0.8 0.2 0 0 20 40 60 Temperature 80 100 Factor (K) of Ambient temperature and Average power P=PoxK Po: Ambient temperature 40ºC & 50ºC P: Ambient temperature TºC K: Factor K=(115-T)/75 Po=40℃ (Blue line) K=(115-T)/65 Po=50℃ (Red line) 7 HF-100D 4" Air dielectric coaxial cable Structure Item Diameter (mm) Materials Inner conductor 38.2 Corrugated copper Insulator 84 Polyethylene Outer conductor 94.6 Corrugated copper Jacket 100 Polyethylene, Black Mechanical Characteristics Item Specification Cable weight 3.7 kg/m Minimum bending radius Single 450 mm Repeated 1000 mm Tensile strength 3000 N Flat plate crush strength 2500 N/50mm Amb. 40℃ Electrical Characteristics Item Specification Impedance 50 Ω Velocity 96 % Direct current resistance (Loop resistance) 55 mΩ/100m Insulation resistance 1000 MΩ-km Peak voltage 10000 V Peak power rating 1000 kW Jacket spark 8000 V RMS Maximum frequency 1400 MHz V.S.W.R. Frequency range (MHz) Specified channel Specified band ( *1) Within range 10 - 30 - 1.05 - 30 - 230 1.05 1.05 1.10 230 - 470 - 1.10 - 470 - 770 1.05 1.05 1.10 770 - 960 1.05 1.10 1.15 *1: Less than 30MHz band 0.5 0.0223 945 790 1 0.0315 665 558 10 0.101 210 175 30 0.177 120 100 50 0.23 92.5 77.4 100 0.33 64.9 54.3 200 0.475 45.2 37.8 300 0.59 36.5 30.6 400 0.67 31.4 26.3 500 0.78 27.9 23.3 600 0.865 25.3 21.2 700 0.94 23.3 19.45 800 1.02 21.6 18.10 900 1.085 20.3 17.00 1000 1.15 19.15 16.05 Condition 1) Attenuation • Ambient temperature 20ºC, Nominal value 2) Average power • Ambient temperature 40ºC & 50ºC • Inner conductor temperature 115ºC • V.S.W.R.=1.0 Accessories 2 Connector / Flange type EIA 6-1/8" IEC 4-1/2” EIA 3-1/8” JEITA BFX-120D JEITA BFX-77D 8 1.8 Structure 1.6 Type 1.4 Female flange Gas through 100D-152D-EFP-11FS Female flange Gas barrier 100D-152D-EFS-11FS Female flange Gas through 100D-IFP-11FS Female flange Gas barrier 100D-IFS-11FS 0.6 Female flange Gas through 100D-77D-EFP-11FS 0.4 Female flange Gas barrier 100D-77D-EFS-11FS Male flange Gas through 100D-120D-WMP-10FS Female flange Gas through 100D-120D-WFP-10RS Coupling Gas barrier 100D-120D-WGS-11NFS Male flange Gas through 100D-77D-WMP-10FS Female flange Gas through 100D-77D-WFP-10RS Coupling Gas barrier 100D-77D-WGS-11NFS Factor (K) Standard Amb. 50℃ Frequency Attenuation Average power Average power (MHz) (dB/100m) (kW) (kW) 1.2 1 0.8 0.2 0 0 20 40 60 Temperature Factor (K) of Ambient temperature and Average power P=PoxK Po: Ambient temperature 40ºC & 50ºC P: Ambient temperature TºC K: Factor K=(115-T)/75 Po=40℃ (Blue line) K=(115-T)/65 Po=50℃ (Red line) 80 100 HF-77D 3-1/8" Air dielectric coaxial cable Structure Item Diameter (mm) Materials Inner conductor 33 Corrugated copper Insulator 71 Polyethylene Outer conductor 81 Corrugated copper Jacket 88 Polyethylene, Black Mechanical Characteristics Item Specification Cable weight 3.0 kg/m Minimum bending radius Single 400 mm Repeated 800 mm Tensile strength 3000 N Flat plate crush strength 2000 N/50mm Amb. 40℃ Electrical Characteristics Item Specification Impedance 50 Ω Velocity 96 % Direct current resistance (Loop resistance) 60 mΩ/100m Insulation resistance 1000 MΩ-km Peak voltage 9700 V Peak power rating 940 kW Jacket spark 8000 V RMS Maximum frequency 1550 MHz V.S.W.R. Frequency range (MHz) Specified channel Specified band ( *1) Within range 10 - 30 - 1.05 - 30 - 230 1.05 1.05 1.10 230 - 470 - 1.10 - 470 - 770 1.05 1.05 1.10 770 - 960 1.05 1.10 1.15 *1: Less than 60MHz band 0.5 0.026 740 645 1 0.04 523 455 10 0.12 165 143 30 0.21 93.5 81.5 50 0.27 72.5 63.0 100 0.39 50.5 44.0 200 0.56 35.5 31.0 300 0.68 29.0 25.0 400 0.80 25.0 21.5 500 0.90 22.4 19.5 600 0.99 20.5 17.8 700 1.10 19.0 16.5 800 1.20 17.8 15.5 900 1.25 16.7 14.6 1000 1.30 15.9 13.8 1500 1.65 13.2 11.5 Condition 1) Attenuation • Ambient temperature 20ºC, Nominal value 2) Average power • Ambient temperature 40ºC & 50ºC • Inner conductor temperature 115ºC • V.S.W.R.=1.0 Accessories 2 Connector / Flange type EIA 3-1/8" JEITA BFX-77D 1.8 Structure 1.6 Type 1.4 Female flange Gas through 77D-EFP-11FS Female flange Gas barrier 77D-EFS-11FS Male flange Gas through 77D-WMP-10FS Female flange Gas through 77D-WFP-10RS 0.6 Coupling Gas barrier 77D-WGS-11NFS 0.4 Factor (K) Standard Amb. 50℃ Frequency Attenuation Average power Average power (MHz) (dB/100m) (kW) (kW) 1.2 1 0.8 0.2 0 0 20 40 60 Temperature 80 100 Factor (K) of Ambient temperature and Average power P=PoxK Po: Ambient temperature 40ºC & 50ºC P: Ambient temperature TºC K: Factor K=(115-T)/75 Po=40℃ (Blue line) K=(115-T)/65 Po=50℃ (Red line) 9 HF-70D 3" Air dielectric coaxial cable Structure Item Diameter (mm) Materials Inner conductor 30.1 Corrugated copper Insulator 65 Polyethylene Outer conductor 74 Corrugated copper Jacket 79 Polyethylene, Black Mechanical Characteristics Item Specification Cable weight 2.5 kg/m Minimum bending radius Single 300 mm Repeated 750 mm Tensile strength 2500 N Flat plate crush strength 2000 N/50mm Amb. 40℃ Electrical Characteristics Item Specification Impedance 50 Ω Velocity 96 % Direct current resistance (Loop resistance) 62 mΩ/100m Insulation resistance 1000 MΩ-km Peak voltage 7600 V Peak power rating 578 kW Jacket spark 8000 V RMS Maximum frequency 1800 MHz V.S.W.R. Frequency range (MHz) Specified channel Specified band ( *1) Within range 10 - 30 - 1.05 - 30 - 230 1.05 1.05 1.10 230 - 470 - 1.10 - 470 - 770 1.05 1.05 1.10 770 - 960 1.05 1.10 1.15 *1: Less than 60MHz band Accessories Connector / Flange type EIA 3-1/8" JEITA BFX-77D Structure 0.5 1 10 30 50 88 100 108 174 200 230 300 400 500 600 700 800 900 960 1000 1500 0.028 0.040 0.125 0.220 0.285 0.381 0.407 0.424 0.544 0.586 0.631 0.727 0.849 0.958 1.06 1.15 1.24 1.33 1.38 1.41 1.77 578 436 137 78.6 60.6 45.4 42.5 40.9 31.9 29.7 27.6 24.1 20.7 18.4 16.7 15.3 14.3 13.4 12.9 12.7 10.1 526 372 117 67 51.7 38.7 36.2 34.8 27.2 25.3 23.6 20.5 17.6 15.7 14.2 13.1 12.2 11.4 11 10.8 8.7 Condition 1) Attenuation • Ambient temperature 20ºC, Nominal value 2) Average power • Ambient temperature 40ºC & 50ºC • Inner conductor temperature 115ºC • V.S.W.R.=1.0 Type 2 Female flange Gas through 70D-EFP-11FS 1.8 Female flange Gas barrier 70D-EFS-11FS 1.6 Male flange Gas through 70D-WMP-10FS 1.4 Female flange Gas through 70D-WFP-10RS Coupling Gas barrier 70D-WGS-11NFS Factor (K) Standard Amb. 50℃ Frequency Attenuation Average power Average power (MHz) (dB/100m) (kW) (kW) 1.2 1 0.8 0.6 0.4 0.2 0 0 10 20 40 60 Temperature Factor (K) of Ambient temperature and Average power P=PoxK Po: Ambient temperature 40ºC & 50ºC P: Ambient temperature TºC K: Factor K=(115-T)/75 Po=40℃ (Blue line) K=(115-T)/65 Po=50℃ (Red line) 80 100 HF-50D 2-1/4" Air dielectric coaxial cable Structure Item Diameter (mm) Materials Inner conductor 21.7 Corrugated copper Insulator 47.5 Polyethylene Outer conductor 55.5 Corrugated copper Jacket 60 Polyethylene, Black Mechanical Characteristics Item Specification Cable weight 2 kg/m Minimum bending radius Single 300 mm Repeated 700 mm Tensile strength 2500 N Flat plate crush strength 2500 N/50mm Amb. 40℃ Electrical Characteristics Item Specification Impedance 50 Ω Velocity 95 % Direct current resistance (Loop resistance) 100 mΩ/100m Insulation resistance 1000 MΩ-km Peak voltage 6300 V Peak power rating 397 kW Jacket spark 8000 V RMS Maximum frequency 2500 MHz V.S.W.R. Frequency range (MHz) Specified channel Specified band ( *1) Within range 10 - 30 - 1.05 - 30 - 230 1.05 1.05 1.10 230 - 470 - 1.10 - 470 - 770 1.05 1.05 1.10 770 - 960 1.05 1.10 1.15 960 - 1400 - 1.10 1.15 1400 - 1700 - 1.10 1.15 1700 - 2300 - 1.10 1.15 0.5 0.038 330 285 1 0.055 232 200 10 0.175 72.5 63 30 0.305 41.5 36 50 0.395 32.0 27.5 100 0.565 22.0 19.0 200 0.85 15.5 13.5 300 1.05 12.5 10.5 400 1.25 10.5 9.20 500 1.4 9.40 8.15 600 1.55 8.55 7.40 700 1.65 7.85 6.75 800 1.75 7.25 6.30 900 2 6.80 5.90 1000 2.1 6.40 5.55 2000 3.05 4.30 3.75 2500 3.5 3.80 3.30 Condition 1) Attenuation • Ambient temperature 20ºC, Nominal value 2) Average power • Ambient temperature 40ºC & 50ºC • Inner conductor temperature 115ºC • V.S.W.R.=1.0 *1: Less than 60MHz band 2 1.8 Accessories 1.6 Connector / Flange type EIA 3-1/8" EIA 1-5/8" EIA 7/8" N type JEITA BFX-20D Structure Type Female flange Gas through 50D-77D-EFP-11FS Female flange Gas barrier 50D-77D-EFS-11FS Female flange Gas through 50D-39D-EFP-11FS Female flange Gas barrier 50D-39D-EFS-11FS Female flange Gas through 50D-20D-EFP-11FS Female flange Gas barrier 50D-20D-EFS-11FS Male Gas barrier 50D-NP-11S Female Gas barrier 50D-NJ-11S Male flange Gas through 50D-20D-WMP-10FS Female flange Gas through 50D-20D-WFP-10RS 1.4 Factor (K) Standard Amb. 50℃ Frequency Attenuation Average power Average power (MHz) (dB/100m) (kW) (kW) 1.2 1 0.8 0.6 0.4 0.2 0 0 20 40 60 Temperature 80 100 Factor (K) of Ambient temperature and Average power P=PoxK Po: Ambient temperature 40ºC & 50ºC P: Ambient temperature TºC K: Factor K=(115-T)/75 Po=40℃ (Blue line) K=(115-T)/65 Po=50℃ (Red line) 11 HF-39D 1-5/8" Air dielectric coaxial cable Structure Item Diameter (mm) Materials Inner conductor 17.2 Copper tube Insulator 39.6 Polyethylene Outer conductor 46.3 Corrugated copper Jacket 51 Polyethylene, Black Mechanical Characteristics Item Specification Cable weight 1.9 kg/m Minimum bending radius Single 200 mm Repeated 600 mm Tensile strength 2000 N Flat plate crush strength 2000 N/50mm Amb. 40℃ Electrical Characteristics Item Specification Impedance 50 Ω Velocity 91 % Direct current resistance (Loop resistance) 65 mΩ/100m Insulation resistance 1000 MΩ-km Peak voltage 5200 V Peak power rating 270 kW Jacket spark 8000 V RMS Maximum frequency 2900 MHz Amb. 50℃ Frequency Attenuation Average power Average power (MHz) (dB/100m) (kW) (kW) V.S.W.R. Frequency range (MHz) Specified channel Specified band ( *1) Within range 10 - 30 - 1.05 - 30 - 230 1.05 1.05 1.10 230 - 470 - 1.10 - 470 - 770 1.05 1.05 1.10 770 - 960 1.05 1.10 1.15 960 - 1400 - 1.10 1.15 1400 - 1700 - 1.10 1.15 1700 - 2300 - 1.10 1.15 2300 - 2700 - 1.10 1.15 0.5 0.046 255 222 1 0.065 186 161 10 0.21 58.5 50.5 30 0.37 33.5 29.0 50 0.48 26.0 22.5 100 0.69 18.2 15.5 200 1.01 12.8 11.1 300 1.3 10.35 8.95 400 1.53 8.95 7.75 500 1.77 7.95 6.90 600 1.97 7.25 6.25 700 2.15 6.70 5.80 800 2.34 6.25 5.40 900 2.51 5.85 5.10 1000 2.7 5.55 4.80 2000 4.1 3.90 3.35 2500 4.9 3.45 2.99 Condition 1) Attenuation • Ambient temperature 20ºC, Nominal value 2) Average power • Ambient temperature 40ºC & 50ºC • Inner conductor temperature 115ºC • V.S.W.R.=1.0 2 *1: Less than 60MHz band 1.8 1.6 Accessories Standard EIA 1-5/8" EIA 7/8" JEITA BFX-39D 12 Structure Type Female flange Gas through 39D-EFP-10RZ Female flange Gas barrier 39D-EFS-11RZ Female flange Gas through 39D-20D-EFP-10RZ Female flange Gas barrier 39D-20D-EFS-11RZ Male flange Gas through 39D-WMP-10FS Female flange Gas through 39D-WFP-10RS Coupling Gas barrier 39D-WGS-11NFS Factor (K) 1.4 Connector / Flange type 1.2 1 0.8 0.6 0.4 0.2 0 0 20 40 60 Temperature Factor (K) of Ambient temperature and Average power P=PoxK Po: Ambient temperature 40ºC & 50ºC P: Ambient temperature TºC K: Factor K=(115-T)/75 Po=40℃ (Blue line) K=(115-T)/65 Po=50℃ (Red line) 80 100 HF-39DB 1-5/8" Air dielectric coaxial cable Structure Item Diameter (mm) Materials Inner conductor 18.5 Corrugated copper Insulator 39.8 Polyethylene Outer conductor 46.3 Corrugated copper Jacket 51 Polyethylene, Black Mechanical Characteristics Item Specification Cable weight 1.3 kg/m Minimum bending radius Single 200 mm Repeated 600 mm Tensile strength 1500 N Flat plate crush strength 1200 N/50mm Amb. 40℃ Electrical Characteristics Item Specification Impedance 50 Ω Velocity 94 % Direct current resistance (Loop resistance) 110 mΩ/100m Insulation resistance 1000 MΩ-km Peak voltage 5200 V Peak power rating 270 kW Jacket spark 8000 V RMS Maximum frequency 2900 MHz V.S.W.R. Frequency range (MHz) Specified channel Specified band ( *1) Within range 10 - 30 - 1.05 - 30 - 230 1.05 1.05 1.10 230 - 470 - 1.10 - 470 - 770 1.05 1.05 1.10 770 - 960 1.05 1.10 1.15 960 - 1400 - 1.10 1.15 1400 - 1700 - 1.10 1.15 1700 - 2300 - 1.10 1.15 2300 - 2700 - 1.10 1.15 *1: Less than 60MHz band 0.5 0.045 270 245 1 0.064 200 170 10 0.204 62 53.5 30 0.341 36 31 50 0.444 27.5 24 88 0.596 21.2 18.35 100 0.638 19.85 17.2 108 0.664 19.1 16.55 174 0.858 14.95 12.95 200 0.923 13.93 12.06 300 1.15 11.25 9.76 400 1.35 9.84 8.36 500 1.52 8.55 7.42 600 1.68 7.75 6.74 700 1.84 7.13 6.19 800 1.98 6.64 5.76 900 2.12 6.22 5.4 1000 2.28 5.87 5.09 2000 3.38 4.00 3.46 2500 3.86 3.56 3.05 Condition 1) Attenuation • Ambient temperature 20ºC, Nominal value 2) Average power • Ambient temperature 40ºC & 50ºC • Inner conductor temperature 115ºC • V.S.W.R.=1.0 Accessories 2 Connector / Flange type EIA 1-5/8" EIA 7/8" JEITA BFX-39D 1.8 Structure 1.6 Type 1.4 Female flange Gas through 39DB-EFP-11FS Female flange Gas barrier 39DB-EFS-11FS Female flange Gas through 39DB-20D-EFP-11FS Female flange Gas barrier 39DB-20D-EFS-11FS 0.6 Male flange Gas through 39DB-WMP-10FS 0.4 Female flange Gas through 39DB-WFP-10RS 0.2 Coupling Gas barrier 39DB-WGS-11NFS Factor (K) Standard Amb. 50℃ Frequency Attenuation Average power Average power (MHz) (dB/100m) (kW) (kW) 1.2 1 0.8 0 0 20 40 60 Temperature Factor (K) of Ambient temperature and Average power P=PoxK Po: Ambient temperature 40ºC & 50ºC P: Ambient temperature TºC K: Factor K=(115-T)/75 Po=40℃ (Blue line) K=(115-T)/65 Po=50℃ (Red line) 80 100 13 HF-20D 7/8" Air dielectric coaxial cable Structure Item Diameter (mm) Materials Inner conductor 8.97 Copper tube Insulator 19.8 Polyethylene Outer conductor 25.8 Corrugated copper Jacket 30 Polyethylene, Black Mechanical Characteristics Item Specification Cable weight 0.9 kg/m Minimum bending radius Single 100 mm Repeated 350 mm Tensile strength 900 N Flat plate crush strength 1000 N/50mm Amb. 40℃ Electrical Characteristics Item Specification Impedance 50 Ω Velocity 91 % Direct current resistance (Loop resistance) 155 mΩ/100m Insulation resistance 1000 MΩ-km Peak voltage 2700 V Peak power rating 73 kW Jacket spark 8000 V RMS Maximum frequency 5600 MHz V.S.W.R. Frequency range (MHz) Specified channel Specified band ( *1) Within range 10 - 30 - 1.05 - 30 - 230 1.05 1.05 1.10 230 - 470 - 1.10 - 470 - 770 1.05 1.05 1.10 770 - 960 1.05 1.10 1.15 960 - 1400 - 1.10 1.15 1400 - 1700 - 1.10 1.15 1700 - 2300 - 1.10 1.15 2300 - 2700 - 1.10 1.15 2700 - 3400 - 1.20 - 0.5 0.086 73 73 1 0.125 73 73 10 0.39 27.3 23.5 30 0.68 15.7 13.6 50 0.89 12.1 10.5 100 1.25 8.50 7.35 200 1.82 5.95 5.15 300 2.29 4.80 4.20 400 2.68 4.15 3.60 500 3.02 3.70 3.20 600 3.35 3.35 2.90 700 3.64 3.10 2.70 800 3.92 2.90 2.50 900 4.2 2.70 2.35 1000 4.45 2.55 2.20 2000 6.7 1.80 1.55 3000 8.6 1.45 1.25 4000 10.5 1.20 1.05 5000 12 1.10 0.95 Condition 1) Attenuation • Ambient temperature 20ºC, Nominal value 2) Average power • Ambient temperature 40ºC & 50ºC • Inner conductor temperature 115ºC • V.S.W.R.=1.0 *1: Less than 60MHz band 2 1.8 Accessories 1.6 Connector / Flange type EIA 7/8" N type DIN type JEITA BFX-20D 14 1.4 Structure Type Female flange Gas through 20D-EFP-10RZ Female flange Gas barrier 20D-EFS-11RZ Male Gas barrier 20D-NP-11S Female Gas barrier 20D-NJ-11S Male Gas barrier 20D-DP-11S Female Gas barrier 20D-DJ-11S Male flange Gas through 20D-WMP-10RS Female flange Gas through 20D-WFP-10RS Coupling Gas barrier 20D-WGS-11NFS Factor (K) Standard Amb. 50℃ Frequency Attenuation Average power Average power (MHz) (dB/100m) (kW) (kW) 1.2 1 0.8 0.6 0.4 0.2 0 0 20 40 60 Temperature Factor (K) of Ambient temperature and Average power P=PoxK Po: Ambient temperature 40ºC & 50ºC P: Ambient temperature TºC K: Factor K=(115-T)/75 Po=40℃ (Blue line) K=(115-T)/65 Po=50℃ (Red line) 80 100 HF-15D 5/8" Air dielectric coaxial cable Structure Item Diameter (mm) Materials Inner conductor 6.3 Copper wire Insulator 13.6 Polyethylene Outer conductor 18.9 Corrugated copper Jacket 23 Polyethylene, Black Mechanical Characteristics Item Specification Cable weight 0.75 kg/m Minimum bending radius Single 80 mm Repeated 250 mm Tensile strength 900 N Flat plate crush strength 1000 N/50mm Amb. 40℃ Electrical Characteristics Item Specification Impedance 50 Ω Velocity 90 % Direct current resistance (Loop resistance) 180 mΩ/100m Insulation resistance 1000 MΩ-km Peak voltage 1800 V Peak power rating 32 kW Jacket spark 8000 V RMS Maximum frequency 7600 MHz V.S.W.R. Frequency range (MHz) Specified channel Specified band ( *1) Within range 10 - 30 - 1.05 - 30 - 230 1.05 1.05 1.10 230 - 470 - 1.10 - 470 - 770 1.05 1.05 1.10 770 - 960 1.05 1.10 1.15 960 - 1400 - 1.10 1.15 1400 - 1700 - 1.10 1.15 1700 - 2300 - 1.10 1.15 2300 - 2700 - 1.10 1.15 2700 - 5000 - 1.20 - 0.5 0.12 32 32 1 0.17 32 28 10 0.54 15 13 30 0.94 8.75 7.50 50 1.22 6.75 5.85 100 1.75 4.75 4.10 200 2.50 3.35 2.90 300 3.10 2.70 2.35 400 3.60 2.35 2.00 500 4.00 2.05 1.80 600 4.50 1.90 1.65 700 4.85 1.75 1.52 800 5.20 1.63 1.41 900 5.55 1.55 1.33 1000 5.90 1.45 1.25 2000 8.55 0.98 0.85 3000 10.75 0.81 0.70 4000 12.70 0.69 0.60 5000 14.50 0.575 0.50 Condition 1) Attenuation • Ambient temperature 20ºC, Nominal value 2) Average power • Ambient temperature 40ºC & 50ºC • Inner conductor temperature 115ºC • V.S.W.R.=1.0 *1: Less than 60MHz band 2 1.8 Accessories 1.6 Connector / Flange type EIA 7/8" N type DIN type 1.4 Structure Type Female flange Gas through 15D-EFP-10RZ Female flange Gas barrier 15D-EFS-11RZ Male Gas barrier 15D-NP-11S Female Gas barrier 15D-NJ-11S Male Gas barrier 15D-DP-11S Female Gas barrier 15D-DJ-11S Factor (K) Standard Amb. 50℃ Frequency Attenuation Average power Average power (MHz) (dB/100m) (kW) (kW) 1.2 1 0.8 0.6 0.4 0.2 0 0 20 40 60 Temperature Factor (K) of Ambient temperature and Average power P=PoxK Po: Ambient temperature 40ºC & 50ºC P: Ambient temperature TºC K: Factor K=(115-T)/75 Po=40℃ (Blue line) K=(115-T)/65 Po=50℃ (Red line) 80 100 15 CLAMP Accessories Clamp type B Cable Dimension (mm) Type Draw A W L M 7/8" HCC-20D-B1 70 20 130 M10 HF-39D 1-5/8" HCC-39D-B1 90 25 140 M12 HF-50D 2-1/4" HCC-50D-B1 100 25 120 M12 HF-70D 3" HCC-70D-B1 130 32 130 M12 HF-77D 3-1/8" HCC-77D-B1 140 32 120 M12 HF-100D 4" HCC-100D-B1 170 40 150 M16 HF-105D 5" HCC-105D-B1 185 40 150 M16 HF-120D 5-1/2" HCC-120D-B1 230 55 170 M16 HF-152D 6-1/8" HCC-152D-B1 250 60 210 M20 Draw Draw W A Holes are required in the steel frame to insert and fasten this type of clamp. W HF-20D A CLAMP BAND BAND (1) BOLTS BOLT BAND (2) STAND BOLTS L L STAND BOLT 110 NUTS, SPRING WASHER M M Clamp type C2 Cable Type Dimension (mm) A W B C HF-20D 7/8" HCC-20D-C2 45 20 40 30 HF-39D 1-5/8" HCC-39D-C2 77 25 50 30 HF-50D 2-1/4" HCC-50D-C2 85 25 75 40 HF-70D 3" HCC-70D-C2 110 32 85 46 HF-77D 3-1/8" HCC-77D-C2 120 32 90 46 HF-100D 4" HCC-100D-C2 145 40 100 46 HF-105D 5" HCC-105D-C2 160 40 105 46 This type of clamp can be directly fastened to the steel frame without holes. Clamp can be used upright or the top of the clamp can be A B BAND C CLEAT 16 W detached and fastened side ways. Accessories CLAMP Clamp type C3 Cable Dimension (mm) Type φD W A B HF-20D 7/8" HCC-20D-C3 φ28 30 53 45 HF-39D 1-5/8" HCC-39D-C3 φ50 38 83 45 HF-50D 2-1/4" HCC-50D-C3 φ60 38 94 45 HF-70D 3" HCC-70D-C3 φ79 38 114 45 HF-77D 3-1/8" HCC-77D-C3 φ87 38 123 45 HF-100D 4" HCC-100D-C3 φ102 43 134 45 HF-105D 5" HCC-105D-C3 φ117 43 149 45 This type of clamp can be directly fastened to the steel frame without holes. Clamp can be used upright or the top of the clamp can be detached and fastened side ways. W BAND A φD B CLEAT Recommended clamp spacing Cable B1 type C2 type C3 type HF-20D 7/8" 1.0 1.0 2.0 HF-39D 1-5/8" 1.5 2.0 2.0 HF-50D 2-1/4" 2.0 2.0 2.0 HF-70D 3" 2.0 2.0 1.5 HF-77D 3-1/8" 2.0 2.0 1.0 HF-100D 4" 2.0 1.5 1.5 HF-105D 5" 2.0 1.5 1.0 HF-120D 5-1/2" 2.0 - - HF-152D 6-1/8" 2.0 - - Recommended clamp space is shown in the above table. (terms: wind speed 60m/s) Please choose an appropriate clamp space according to the wind speed condition. Maximum clamp space according to the wind speed condition B1 type clamp Wind speed (m/s) Cable C2 type clamp Wind speed (m/s) C3 type clamp Wind speed (m/s) 40 50 60 70 40 50 60 70 40 50 60 70 HF-20D 7/8" 1.2 1.1 1.0 0.9 1.2 1.1 1.0 0.8 2.0 2.0 2.0 2.0 HF-39D 1-5/8" 1.4 1.3 1.5 1.5 2.5 2.0 2.0 1.5 2.0 2.0 2.0 2.0 HF-50D 2-1/4" 3.0 2.5 2.0 1.5 3.0 2.5 2.0 1.5 2.0 2.0 2.0 2.0 HF-70D 3" 3.0 2.5 2.0 1.4 3.0 3.0 2.0 1.5 2.0 2.0 1.5 1.0 HF-77D 3-1/8" 3.0 2.5 2.0 1.4 3.0 3.0 2.0 1.5 2.0 1.5 1.0 0.5 HF-100D 4" 3.0 2.5 2.0 1.5 2.5 2.0 1.5 1.0 2.0 1.5 1.5 1.0 HF-105D 5” 3.0 2.5 2.0 1.5 2.5 2.0 1.5 1.0 2.0 1.5 1.0 1.0 HF-120D 5-1/2" 3.0 2.5 2.0 1.4 - - - - - - - - HF-152D 6-1/8" 4.0 3.0 2.0 1.5 - - - - - - - - 17 EARTHING KIT Accessories Type N 2-M5 (STAINLESS) Type L HF-20D 7/8" GB-20D-N 35 HF-39D 1-5/8" GB-39D-N 35 HF-50D 2-1/4" GB-50D-N 35 HF-70D 3" GB-70D-N 35 HF-77D 3-1/8" GB-77D-N 35 HF-100D 4" GB-100D-N 65 HF-105D 5" GB-105D-N 65 HF-120D 5-1/2" GB-120D-N 65 HF-152D 6-1/8" GB-152D-N 75 WATER PROOF TAPE BRIDED COPPER STRIP TIGHTENING CLAMP L Cable Dimension GROUNDING WIRE ADHESIVE PVC TAPE Approx,1000 Caution 1. Length of the grounding wire is fixed with the copper terminal already attached. 2. Please prepare water proof tape and adhesive PVC tape on your own. 3. Water proof tape and adhesive PVC tape are separately sold material. 4. Please contact us when you difficult to purchase the material on your country. Type A Cable Dimension (mm) Type L HF-20D 7/8" GB-20D 60 HF-39D 1-5/8" GB-39D 60 HF-50D 2-1/4" GB-50D 80 HF-70D 3" GB-70D 100 HF-77D 3-1/8" GB-77D 100 HF-100D 4" GB-100D 125 HF-105D 5" GB-105D 125 HF-120D 5-1/2" GB-120D 150 HF-152D 6-1/8" GB-152D 200 GB-203D 250 HF-203D-S 8" Construction of Clamping band EARTHING KIT SELF-BONDING TAPE ADHESIVE PVC TAPE APPROX L CABLE CLAMPING BAND COPPER STRANDED WIRE (22mm2) 18 17 COPPER TERMINAL CONPOUND Length of the copper strand wire is adjustable. Copper terminal needs to be attached at the end of the wire separately. WALL GLAND Accessories Type A, Single run 10-M10 BOLTS Type (STAINLESS) ADHESIVE PVC TAPE 7/8" WMS-20D-1A ADHESIVE ALUMINIUM TAPE HF-39D 1-5/8" WMS-39D-1A SELF-BONDING TAPE HF-50D 2-1/4" WMS-50D-1A HF-77D 3-1/8" WMS-77D-1A HF-105D 5" WMS-105D-1A HF-120D 5-1/2" WMS-120D-1A HF-152D 6-1/8" WMS-152D-1A 20 300 130 130 20 20 HF-20D COMPOUND HF CABLE 300 130 ADHESIVE AGENT 130 ADAPTOR CLAMPING BAND GASKET 60 Cable (STAINLESS) This wall gland can be assembled sandwich the cable after it has been threaded before being attached to the wall. 20 PLATE Type A, Dual run Cable Dimension (mm) Type Draw P HF-20D 7/8" WMS-20D-2A 160 HF-39D 1-5/8" WMS-39D-2A 200 HF-50D 2-1/4" WMS-50D-2A 200 HF-77D 3-1/8" WMS-77D-2A 200 HF-105D 5" WMS-105D-2A 400 HF-120D 5-1/2" WMS-120D-2A 400 HF-152D 6-1/8" WMS-152D-2A 440 Draw Draw BOLTS(12-M10) (STAINLESS) ADHESIVE PVC TAPE 14-M10 BOLTS (STAINLESS) ADHESIVE ALUMINIUM TAPE SELF-BONDING TAPE 20 20 P COMPOUND 100 60 100 P 80 100 80 20 20 300 110 120 120 110 20 P PLATE 18-M10 BOLTS (STAINLESS) 1 2 3 4 5 10-M6 BOLTS φ222 60 150 φ174 SUS BAND 2 3 5 COMPOUND SELF BONDING TAPE ADHESIVE ALUMINIUM TAPE ADHESIVE VINYL TAPE ADHESIVE AGENT 400 5 20 φ 20 GASKET 4 150 20 235 200 1 GASKET 500 Draw 40 CLAMPING BAND (STAINLESS) ADAPTOR 20 20 50 φ56 20 ADHESIVE AGENT 300 60 200 50 φ72 20 150 150 130 130 150 150 20 900 19 Accessories WALL GLAND Type 1C, Single run Cable Dimension (mm) Type Draw D1 D2 L P Bolts HF-20D 7/8" WMS-20D-1C 130 80 50 110 8-M5 HF-39D 1-5/8" WMS-39D-1C 130 80 50 110 8-M5 HF-50D 2-1/4" WMS-50D-1C 130 80 50 110 8-M5 HF-70D 3" WMS-70D-1C 200 130 80 170 8-M10 HF-77D 3-1/8" WMS-77D-1C 200 130 80 170 8-M10 HF-100D 4" WMS-100D-1C 230 160 80 200 8-M10 HF-105D 5" WMS-105D-1C 230 160 80 200 8-M10 HF-120D 5-1/2" WMS-120D-1C 260 190 90 230 8-M10 HF-152D 6-1/8" WMS-152D-1C 285 210 95 260 8-M10 This wall gland must be attached to the wall before the cable can be threaded. Draw φ80 φD2 Draw 50 PLATE MOLDED RUBBER (STAINLESS) BOLTS (M5) (STAINLESS) MOLDED RUBBER STAINLESS BAND φ130 10 φ1 20 HF CABLE PLATE (STAINLESS) L HF CABLE BOLTS (M10) (STAINLESS) φD1 φP STAINLESS BAND Accessories HOISTING STOCKING Hoisting Stocking Cable Type Dimension(mm) L1 L2 Rd HF-20D 7/8" HSC-20D 690 390 R20 HF-39D 1-5/8" HSC-39D 820 520 R20 HF-50D 2-1/4" HSC-50D 860 560 R20 HF-70D 3" HSC-70D 940 640 R20 HF-77D 3-1/8" HSC-77D 940 640 R20 HF-100D 4" HSC-100D 1350 1050 R20 HF-105D 5" HSC-105D 1350 1050 R20 HF-120D 5-1/2" HSC-120D 1550 1150 R20 HF-152D 6-1/8" HSC-152D 1700 1250 R20 Rd Material: Stainless wire (stocking) Aluminum (sleeve) HOISTING STOCKING L2 L1 This product is used for pulling the cable up during installation. CLAMPING BAND HF CABLE Fixing use Dimension(mm) Cable Type L1 L2 HF-20D 7/8" HSF-20D 450 300 HF-39D 1-5/8" HSF-39D 600 400 HF-50D 2-1/4" HSF-50D 780 520 HF-70D 3" HSF-70D 910 700 HF-77D 3-1/8" HSF-77D 910 700 HF-100D 4" HSF-100D 1350 900 HF-105D 5" HSF-105D 1350 900 HF-120D 5-1/2" HSF-120D 1800 1200 HF-152D 6-1/8" HSF-152D 1800 1200 Bolt (M16) Eyebolt (M16) TURN BUCKLES Material: Stainless wire (stocking, clamping band) Galvanized steel (eyebolt, turn buckle) This product is used for fixing cable to the tower. Recommended fixation interval is 50m on the vertical part of the tower. Loosening or HOISTING STOCKING L2 L1 tightening the turnbuckles can adjust the tautness of the hoisting stocking. CLAMPING BAND HF CABLE 21 Accessories CONNECTOR and TOOL Connector Cable Type HF-20D 7/8" HF-39D 1-5/8" HF-39DB 1-5/8" HF-50D 2-1/4" HF-70D 3" HF-77D 3-1/8" HF-100D 4" HF-105D 5" HF-120D 5-1/2" HF-152D 6-1/8" See each cable sheet HF-203D-S 8" The structure of the trade type name of connector (1) Flange interface connector 39D − EFP − 10FS Cable size and flange size is same. Cable size Outer conductor size in mm, D means 50Ω Standard of Flange E:EIA I:IEC W:JEITA Inner conductor F:Female M:Male Gas pass/stop P:Gas pass S:Gas stop Gas inlet exist or not 10:Inlet non 11:Inlet exist Flange swivel or not F:Not swivel R:Swivle flange Inner conductor assemble S:Taper nut lock Z:Screw lock (2) Flange interface reducer type connector 3 9 D − 2 0 D − E F P − 10 F S Cable size and flange size is different. Cable size Outer conductor size in mm, D means 50Ω Flange size Outer conductor size in mm, D means 50Ω Standard of Flange E:EIA I:IEC W:JEITA Inner conductor F:Female M:Male Gas pass/stop P:Gas pass S:Gas stop Gas inlet exist or not 10:Inlet non 11:Inlet exist Flange (swivel or not) / Non Flange F:Not swivel flange R:Swivel flange NF:Non Flange Inner conductor assemble S:Taper nut lock Z:Screw lock Cable size Outer conductor size in mm, D means 50Ω Standard of interface N:N type D:DIN-7/16 Inner conductor J:Jack(Female) P:Plug(Male) Gas inlet exist or not 11:Inlet exist 12:Inlet non Inner conductor assemble S:Taper nut lock Z:Screw lock (3) N,DIN type interface connector 3 9 D − N J − 11 S Note:In case of HF-39DB, please use “DB” instead of “D” 22 Accessories CONNECTOR and TOOL Tool Kit Cable Type HF-20D 7/8" FTK-20D HF-39D 1-5/8" FTK-39D HF-50D 2-1/4" FTK-50D HF-70D 3" FTK-70D HF-77D 3-1/8" FTK-77D HF-100D 4" FTK-100D HF-105D 5" FTK-105D HF-120D 5-1/2" FTK-120D HF-152D 6-1/8" FTK-152D HF-203D-S 8" FTK-203D This tool kit is for attaching connectors at the end of the cable. The flaring tool included will enhance V.S.W.R. performance because it is precisely engineered to elminate the risk of connector burnout from hot spots. Gas Inlet Pipe Copper Decabon Vinyl Type 10 GI-C10 6 GI-C6 3/8" GI-C3/8 1/4" GI-C1/4 6 GI-DC6 6 GI-V6 8 GI-V8 9 GI-V9 Gas inlets are used to connect the gas pipe/hose to the connector (gas stop) to inflate gas into the cable. A variety of sizes are available depending on the pipe/hose used. 23 Rigid Coaxial Line DF, WX- Rigid Coaxial Line (with Flange) Standard EIA IEC JEITA Hitachi Type 7/8" WX-20DF 1-5/8" WX-39DF 3-1/8" WX-77DF 6-1/8" WX-152DF Standard 4-1/2" WX-105DF 20D WX-20DF(J) 39D WX-39DF(J) 77D WX-77DF(J) 120D WX-120DF(J) 152D WX-152DF(J) 203D WX-203DF(J) EIA IEC Outer conductor WX-152DNF 4-1/2" WX-105DNF 20D WX-20DNF(J) 39D WX-39DNF(J) 77D WX-77DNF(J) 120D WX-120DNF(J) 152D WX-152DNF(J) 203D WX-203DNF(J) Dimension 4-1/2" 5" 6-1/8" 8" 14.94 31.27 42.8 50.1 64.0 86.2 Outer (mm) 8.66 16.87 33.40 44.73 52.1 66.0 88.2 Inner (mm) 19.94 38.79 76.89 103 120.0 151.9 203 Outer (mm) 22.23 41.30 79.38 106 123.2 155.6 208 2,000 2,000 2,000 5,000 4,000 5,000 4,000 1.6 7/8" 1-5/8" 3-1/8" 4-1/2" 1.4 5" 6-1/8" 8" 50 99.5 99.5 99.5 99.5 99.5 99.5 99.5 Inner (mΩ/m) 1.08 0.36 0.16 0.130 0.107 0.084 0.063 Outer (mΩ/m) 0.23 0.11 0.06 0.035 0.028 0.019 0.011 2,500 5,000 9,900 13,000 15,500 19,500 25,000 63 250 980 1,690 2,403 3,803 6,250 6,200 3,250 1,650 1,200 1,050 860 650 Peak voltage (V) Peak power rating (kW) Maximum frequency (MHz) *The copper tube and the insulator can be separately delivered. Copper tube: WX- □□ DNF-T Specification Size Velocity (%) Insulation resistance (MΩ) > 5,000 VHF < 1.05 UHF < 1.05 100 MHz (dB/100m) 1.24 0.64 0.33 0.25 0.215 0.17 200 MHz (dB/100m) 1.76 0.915 0.47 0.355 0.31 0.25 0.19 500 MHz (dB/100m) 2.79 1.46 0.76 0.58 0.5 0.41 0.315 800 MHz (dB/100m) 3.55 1.86 0.975 0.745 0.65 0.53 - 100 MHz (kW) 12.3 27. 79.4 121 190 250 402 200 MHz (kW) 8.7 19.6 55.7 85.2 133 176 278 500 MHz (kW) 5.5 12.3 34.8 53.2 83.9 109 168 800 MHz (kW) 4.3 9.7 27.4 41.9 66.5 86.3 - Condition 1)Attenuation •Ambient temperature 20 ºC, Nominal value 2)Average power •Ambient temperature 50 ºC •Inner conductor temperature 150 ºC 24 WX-77DNF 6-1/8" 7.39 Impedance (Ω) Average power 2) WX-39DNF 3-1/8" 3-1/8" Item Attenuation 1) 1-5/8" Hitachi Electrical Characteristics V.S.W.R. WX-20DNF 1-5/8" Standard length (mm) Direct current resistance Type 7/8" 7/8" Inner (mm) Inner conductor Size JEITA Size Item DNF-T Rigid Coaxial Line (None Flange) Size Structure DNF, WX- •V.S.W.R.=1.0 0.13 1.2 Factor (K) Type WX- 1.0 0.8 0.6 0.4 0.2 0 0 50 40 60 80 100 Temperature Factor (K) of Ambient temperature and Average power P=Po x K K=(150 -T) / 100 Po: Average power at Ambient temperature 50 ºC P: Average power Ambient temperature T ºC Rigid Coaxial Line 90 degree Elbow (Flange) Standard EIA IEC JEITA Size Type 7/8" ELB-20D 1-5/8" ELB-39D 3-1/8" ELB-77D 6-1/8" ELB-152D 4-1/2" ELB-105D 20D ELB-20D(J) 39D ELB-39D(J) 77D ELB-77D(J) 120D ELB-120D(J) 152D ELB-152D(J) Type ELBAnchor connector Standard Size Type 7/8" ACX-20D 1-5/8" ACX-39D 3-1/8" ACX-77D 6-1/8" ACX-152D IEC 4-1/2" ACX-105D JEITA 120D ACX-120D EIA Standard Size Type 7/8" IEB-20D 1-5/8" IEB-39D 3-1/8" IEB-77D 6-1/8" IEB-152D IEC 4-1/2" IEB-105D JEITA 120D IEB-120D EIA Straight coupling (Indoor use) Standard Size Type 7/8" SCX-20D 1-5/8" SCX-39D 3-1/8" SCX-77D 6-1/8" SCX-152D IEC 4-1/2" SCX-105D JEITA 120D SCX-120D EIA Coupling adaptor (Flange to coupling) Size Type Straight coupling (Indoor use) Size Type 7/8" ICA-20D 7/8" SCX-20D-S 1-5/8" ICA-39D 1-5/8" SCX-39D-S 3-1/8" ICA-77D 3-1/8" SCX-77D-S 6-1/8" ICA-152D 6-1/8" SCX-152D-S IEC 4-1/2" ICA-105D IEC 4-1/2" SCX-105D-S JEITA 120D ICA-120D JEITA 120D SCX-120D-S Standard EIA Inner Support Standard Size Type 7/8" ISX-20D 1-5/8" ISX-39D 3-1/8" ISX-77D 6-1/8" ISX-152D IEC 4-1/2" ISX-105D JEITA 120D ISX-120D EIA D Type IEBD, SCXD, ICAD, SCXD-S, ISXD, ICXD Rigid Coaxial Line (Indoor) 90 degree Elbow (Indoor use) D, ACX- Standard EIA Inner connector Standard Size Type 7/8" ICX-20D 1-5/8" ICX-39D 3-1/8" ICX-77D 6-1/8" ICX-152D IEC 4-1/2" ICX-105D JEITA 120D ICX-120D EIA 25 Dehydrator Type MINILAB, LAB4.50, LAB9.50 This device pressurizes by dry air the coaxial cable to prevent moisture entering, thus increasing the cable performance and lifetime. Manufacturer:CIBRED SUD(Our Partner Company) Item Output pressure Operating voltage MINILAB LAB4.50 LAB9.50 1 to 6 kPa (factory presettable) 10 to 60 kPa 10 to 60 kPa AC 100 - 240 V 50/60 Hz AC 220 - 240 V 50/60 Hz AC 220 - 240 V 50/60 Hz *1) Maximum flow rate 150 Nℓ/h 300 Nℓ/h 1000 Nℓ/h Better than -45 ℃ Better than -45 ℃ Better than -45 ℃ Normal operation ≦ 2.5 W ≦ 30 VA ≦ 30 VA Regeneration phase ≦ 55 W ≦ 80 VA ≦ 160 VA Dew point Power Consumption Outlets Dimension Weight 6 6 4 or 8 Wall mounting 482x88x190 mm 482x131x305 mm 482x310x230 mm Rack 19" mounting 482x88x190 mm 482x131x202 mm 482x310x150 mm Frame N3 mounting 533x88x190 mm 532x131x202 mm 533x310x150 mm Wall mounting 4.2 kg 8.5 kg 14 kg Rack mounting 4.2 kg 8.5 kg 14 kg *1) Others on request Type DHK-2, DHK-3, DHK-15 Item Nominal capacity (little/min.) DHK-2 DHK-3 DHK-15 DHK-15S 2 3 15 15 Operating voltage Consumption power AC100V/AC200V 70(VA) 70(VA) Dew point Pressure Outlets Dimension (mm) Weight (kg) 26 600(W) 600(W) -40 ºC Upper (Mpa) 0.035±0.003 Lower (Mpa) 0.01±0.003 3 0.035±0.003 0.01±0.003 3 to 6 1 to 6 1 to 8 530 x 360 x 120 600 x 450 x 150 950 x 450 x 400 920 x 650 x 210 20 25 80 70 INSTALLATION OF HF CABLES Antenna Pulley Connector Hoisting stocking Protection cover Recommended pulling length per hoisting stocking 50m Wire grip Hoisting stocking (during installation) Band or rope Tower HF Cable Hoisting wire Cable drum Winch 27 Caution when installing cables Please pay attention to the following points in order to keep the electrical and mechanical characteristics of HF cables in optimum working condition. ● Do not bend less than the minimum bending radius specified in this catalog. Bending less than minimum bending radius can cause serious damage to the cable. ● Avoid putting undue pressure on the cable. Do not drop tools or other objects on the cable. ● Do not leave a cut cable unattached. After cutting cable, please attach the connector or waterproof it as soon as possible. ● Maximum pulling tension for the cable must be especially kept within the permissible limit. To prevent damages during cable laying, hoisting and installation. ● Don’t drag the cable on sharp edged objects. To avoid dameages of cable jacket. If dameged, will have influence upon the life of cable. ● When laying/hoidting cable, do not grip the connector portion. To grip the cable portion with hoisting stocking. To protect the connevtor with protection cover. Attenuation value The attenuation values on this catalog are Nominal values. The Maximum values of attenuation are 105% of Nominal values. When requesting information, Please provide us with the following. 1. Frequency band. 2. Cable length. 3. Connector type (EIA, JEITA, DIN, IEC, etc.) 4. If you need the tool kit to attach connectors. - ACX is the code of Anchor Connector for coaxial transmission lines. - WMS is the code of Wall entrygland Molded rubber (single run). - HSC is the code of Hoisting Stocking (installation type). - HSF is the code of Hoisting Stocking (Fix type). - NFS is the code of Not Flange and Screw stop. - ELB is the code of 90 degree ELBow with flange. - IEB is the code of Indoor use 90 degree EIBow not flange. - ICA is the code of Indoor use Coupling Adaptor with Flange. - ISX is the code of Inner Support for rigid coaxial line. - SCX is the code of Straight Coupling for rigid coaxial line. - SCX-S is the code of Straight Coupling with Silver plating for rigid coaxial line. - ICX is the code of Inner Connector for rigid coaxial line. - Specifications subject to change without notice. 28 MEMO MEMO MEMO Cable Materials Company Hulic Asakusabashi Building, 22-16, Asakusabashi 1-chome, Taito-ku, Tokyo 111-0053, Japan Tel: +81-3-6381-1397 Hitachi Metals Europe GmbH Hitachi Metals Hong Kong Ltd. HEAD OFFICE Units 2212-14, 22/F., Miramar Tower, 132 Nathan Road, Tsimshatsui, Kowloon, Hong Kong Tel: +852-2724-4183 Immermannstrasse 14-16, 40210 Dusseldorf, Germany Tel: +49-211-16009-0 LONDON OFFICE Whitebrook Park, Lower Cookham Road, Maidenhead, Berkshire, SL6 8YA United Kingdom Tel: +44-1628-585960 MUNICH OFFICE Radlkoferstraße 2, 81373 Munich, Germany Tel: +49-89-7411-85114 MILANO OFFICE Via Modigliani, 45 - 20090 Segrate (MI) - Italy Tel: +39-02-7530188 Hitachi Cable America Inc. 2 Manhattanville Road, Suite 301, Purchase, NY 10577, U.S.A. Tel: +1-914-694-9200 Hitachi Metals Singapore Pte. Ltd. 12 Gul Avenue, Singapore 629656 Tel: +65-6861-7711 HCAS Thai Trading Co., Ltd. Hitachi Metals Taiwan, Ltd. Taipei Branch 11F, No. 9, Xiangyang Rd, Zhongzheng District Taipei City, Taiwan Tel: +886-2-2311-2777 Hitachi Cable (China) Trading Co., Ltd. H E A D O F F I C E & S A L E S D I VISION 11F, Chong Hing Finance Center, No. 288, NanJing Road (West), Shanghai, 200003, China Tel: +86-21-3366-3000 GUANGZHOU OFFICE Room1001, Goldlion Digital Network Center, 138 Tiyu Road East, Tianhe, Guangzhou 510620, China Tel: +86-20-3878-0319 Hitachi Cable Trading (Dalian F.T.Z.) Co., Ltd. Room 1102, Yoma IFC, No.128 Jinma Road, Dalian Development Area, Dalian, 116600, China Tel: +86-411-8733-2112 Unit 13A, 13th Floor, Ploenchit tower, 898 Ploenchit Road, Limpini, Pathumwan, Bangkok 10330, Thailand. Tel: +66-(0)2-260-6310 h t t p : / / w w w. h i t a c h i - m e t a l s. c o. j p CAT.NO.KTE305D The specifications of products in this catalog are subject to change without pr ior notice. Printed in Japan ’ 14-2 (D)