high frequency coaxial transmission cables

©TOKYO-SKYTREE
FEATURES
HF cables are noted for the following features:
Super flexibility, for installation.
Larger average power rating.
Smaller attenuation value.
Customized cable length available.
Excellent V.S.W.R.
Light weight and easy handling. Due to its corrugated outer conductor,
can handle external pressure on.
Cable uses its own unique oxygen-free copper to create copper Toughlex,
as the outer conductor.
Connector
Inner conductor
Insulator
Outer conductor
Jacket
HFcable
2
APPLICATION
Broadcasting
Mainly used as the main and branch feeders for transmission.
(a) Medium-wave, short-wave radio broadcasting
(b) FM radio broadcasting
(c) VHF-TV broadcasting
(d) UHF-TV broadcasting
General use
(a) Radar equipment
(b) Antenna feeder
(c) Microwave relay installation
3
HF-203D-S
8"
Air dielectric coaxial cable
Structure
Item
Diameter (mm)
Materials
Inner conductor
89.1
Corrugated copper
Insulator
196
PFA
Outer conductor
215
Corrugated copper
Jacket
226
Polyethylene, Black
Mechanical Characteristics
Item
Specification
Cable weight
15 kg/m
Minimum bending radius
Single
1700 mm
Repeated
2500 mm
Tensile strength
4700 N
Flat plate crush strength
5000 N/50mm
Amb. 40℃
Electrical Characteristics
Item
Specification
Impedance
50 Ω
Velocity
96 %
Direct current resistance
(Loop resistance)
16 mΩ/100m
Insulation resistance
1000 MΩ-km
Peak voltage
20000 V
Peak power rating
4000 kW
Jacket spark
8000 V RMS
Maximum frequency
650 MHz
V.S.W.R.
Frequency range (MHz) Specified channel Specified band ( *1) Within range
10 - 30
-
1.07
-
30 - 230
1.05
1.10
1.15
230 - 470
-
1.10
-
470 - 650
1.05
1.10
1.15
0.5
0.011
4000
4000
1
0.015
4000
4000
10
0.048
1395
1270
30
0.085
785
715
50
0.115
600
545
100
0.168
412
375
200
0.252
280
255
300
0.321
222
201
400
0.391
187
170
500
0.461
163
148
600
0.531
147
133
650
0.55
138
125
Condition
1) Attenuation
• Ambient temperature 20ºC, Nominal value
2) Average power
• Ambient temperature 40℃ & 50ºC
• Inner conductor temperature 150ºC
• V.S.W.R.=1.0
*1: Less than 30MHz band
1.6
1.4
Accessories
1.2
-
Structure
Type
Female flange
Gas through
203D-WFP-10FS
Female flange
Gas barrier
203D-WFS-11FS
Factor (K)
Connector/Flange type
Standard
Amb. 50℃
Frequency Attenuation Average power Average power
(MHz)
(dB/100m) (kW)
(kW)
1
0.8
0.6
0.4
0.2
0
0
20
40
60
Temperature
Factor (K) of Ambient temperature and Average power
P=PoxK
Po: Ambient temperature 40℃ & 50ºC
P: Ambient temperature TºC
K: Factor K=(150-T)/110 Po=40℃ (Blue line)
K=(150-T)/100 Po=50℃ (Red line)
4
80
100
HF-152D
6-1/8"
Air dielectric coaxial cable
Structure
Item
Diameter (mm)
Materials
Inner conductor
66.7
Corrugated copper
Insulator
147
Polyethylene
Outer conductor
162
Corrugated copper
Jacket
174
Polyethylene, Black
Mechanical Characteristics
Item
Specification
Cable weight
9.1 kg/m
Minimum bending radius
Single
1200 mm
Repeated
2000 mm
Tensile strength
Flat plate crush
strength
5000 N
5000 N/50mm
Amb. 40℃
Item
Specification
Impedance
50 Ω
Velocity
96 %
Amb. 50℃
Frequency Attenuation Average power Average power
(MHz)
(dB/100m) (kW)
(kW)
Electrical Characteristics
0.5
0.013
2505
2170
1
0.0185
1770
1530
10
0.058
550
480
30
0.11
315
275
50
0.135
244
210
100
0.19
171
148
200
0.275
120
104
Direct current resistance
(Loop resistance)
23 mΩ/100m
Insulation resistance
1000 MΩ-km
Peak voltage
17000 V
Peak power rating
2890 kW
300
0.34
97.0
84.0
Jacket spark
8000 V RMS
400
0.395
83.5
72.5
Maximum frequency
860 MHz
500
0.45
74.5
64.5
600
0.495
68.0
59.0
700
0.54
63.0
54.5
800
0.58
58.5
51.0
850
0.6
56.5
49.5
V.S.W.R.
Frequency range (MHz) Specified channel Specified band (*1)
Within range
10 - 30
-
1.05
-
30 - 230
1.05
1.05
1.10
230 - 470
-
1.10
-
470 - 770
1.05
1.05
1.10
770 - 850
1.05
1.10
1.15
Condition
1) Attenuation
• Ambient temperature 20ºC, Nominal value
2) Average power
• Ambient temperature 40℃ & 50ºC
• Inner conductor temperature 115ºC
• V.S.W.R.=1.0
*1: Less than 30MHz band
2
1.8
Accessories
1.6
Connector/Flange type
EIA 6-1/8"
JEITA
BFX-152D
1.4
Structure
Type
Female flange
Gas through
152D-EFP-11FS
Female flange
Gas barrier
152D-EFS-11FS
Male flange
Gas through
152D-WMP-10FS
Female flange
Gas through
152D-WFP-10RS
Coupling
Gas barrier
152D-WGS-11NFS
Factor (K)
Standard
1.2
1
0.8
0.6
0.4
0.2
0
0
20
40
60
Temperature
80
100
Factor (K) of Ambient temperature and Average power
P=PoxK
Po: Ambient temperature 40℃ & 50ºC
P: Ambient temperature TºC
K: Factor K=(115-T)/75 Po=40℃ (Blue line)
K=(115-T)/65 Po=50℃ (Red line)
5
HF-120D
5-1/2"
Air dielectric coaxial cable
Structure
Item
Diameter (mm)
Materials
Inner conductor
58
Corrugated copper
Insulator
127
Polyethylene
Outer conductor
140.5
Corrugated copper
Jacket
148
Polyethylene, Black
Mechanical Characteristics
Item
Specification
Cable weight
7.8 kg/m
Minimum bending radius
Single
900 mm
Repeated
1600 mm
Tensile strength
3500 N
Flat plate crush strength
3000 N/50mm
Amb. 40℃
Electrical Characteristics
Item
Specification
Impedance
50 Ω
Velocity
96 %
Direct current resistance
(Loop resistance)
27 mΩ/100m
Insulation resistance
1000 MΩ-km
Peak voltage
15000 V
Peak power rating
2250 kW
Jacket spark
8000 V RMS
Maximum frequency
950 MHz
V.S.W.R.
Frequency range (MHz) Specified channel Specified band ( *1) Within range
10 - 30
-
1.05
-
30 - 230
1.05
1.05
1.10
230 - 470
-
1.10
-
470 - 770
1.05
1.05
1.10
770 - 950
1.05
1.10
1.15
*1: Less than 30MHz band
0.5
0.015
1885
1635
1
0.0215
1330
1155
10
0.0675
415
360
30
0.12
240
208
50
0.155
185
160
100
0.22
130
112
200
0.315
91.0
78.5
300
0.39
74.0
64.0
400
0.455
64.0
55.5
500
0.515
57.0
49.5
600
0.57
52.0
45.0
700
0.62
48.5
42.0
800
0.665
45.5
39.0
900
0.715
42.5
37.0
950
0.74
41.5
36.0
Condition
1) Attenuation
• Ambient temperature 20ºC, Nominal value
2) Average power
• Ambient temperature 40ºC & 50ºC
• Inner conductor temperature 115ºC
• V.S.W.R.=1.0
2
Accessories
1.8
Connector / Flange type
IEC 4-1/2"
JEITA
BFX-120D
1.6
Structure
Type
1.4
1.2
Female flange
Gas through
120D-105D-IFP-11FS
Female flange
Gas barrier
120D-105D-IFS-11FS
Male flange
Gas through
120D-WMP-10FS
Female flange
Gas through
120D-WFP-10RS
Coupling
Gas barrier
120D-WGS-11NFS
Factor (K)
Standard
Amb. 50℃
Frequency Attenuation Average power Average power
(MHz)
(dB/100m) (kW)
(kW)
1
0.8
0.6
0.4
0.2
0
0
20
40
60
Temperature
Factor (K) of Ambient temperature and Average power
P=PoxK
Po: Ambient temperature 40ºC & 50ºC
P: Ambient temperature TºC
K: Factor K=(115-T)/75 Po=40℃ (Blue line)
K=(115-T)/65 Po=50℃ (Red line)
6
80
100
HF-105D
5"
Air dielectric coaxial cable
Structure
Item
Diameter (mm)
Materials
Inner conductor
45
Corrugated copper
Insulator
98
Polyethylene
Outer conductor
109
Corrugated copper
Jacket
117
Polyethylene, Black
Mechanical Characteristics
Item
Specification
Cable weight
4.85 kg/m
Minimum bending radius
Single
500 mm
Repeated
1300 mm
Tensile strength
3000 N
Flat plate crush strength
3000 N/50mm
Amb. 40℃
Electrical Characteristics
Item
Specification
Impedance
50 Ω
Velocity
96 %
Direct current resistance
(Loop resistance)
42 mΩ/100m
Insulation resistance
1000 MΩ-km
Peak voltage
12500 V
Peak power rating
1560 kW
Jacket spark
8000 V RMS
Maximum frequency
1130 MHz
V.S.W.R.
Frequency range (MHz) Specified channel Specified band ( *1) Within range
10 - 30
-
1.05
-
30 - 230
1.05
1.05
1.10
230 - 470
-
1.10
-
470 - 770
1.05
1.05
1.10
770 - 960
1.05
1.10
1.15
*1: Less than 30MHz band
0.5
0.0195
1200
1040
1
0.028
848
735
10
0.088
266
230
30
0.155
153
132
50
0.2
118
102
100
0.285
82.5
71.5
200
0.41
58.0
50.0
300
0.505
47.0
40.5
400
0.585
40.5
35.0
500
0.66
36.0
31.5
600
0.73
33.0
28.5
700
0.79
30.5
26.5
800
0.85
28.5
24.5
900
0.91
26.5
23.0
1000
0.96
25.5
22.0
Condition
1) Attenuation
• Ambient temperature 20ºC, Nominal value
2) Average power
• Ambient temperature 40ºC & 50ºC
• Inner conductor temperature 115ºC
• V.S.W.R.=1.0
Accessories
2
Connector / Flange type
EIA 6-1/8"
IEC 4-1/2"
EIA 3-1/8"
JEITA
BFX-120D
JEITA
BFX-77D
1.8
Structure
1.6
Type
1.4
Female flange
Gas through
105D-152D-EFP-11FS
Female flange
Gas barrier
105D-152D-EFS-11FS
Female flange
Gas through
105D-IFP-11FS
Female flange
Gas barrier
105D-IFS-11FS
0.6
Female flange
Gas through
105D-77D-EFP-11FS
0.4
Female flange
Gas barrier
105D-77D-EFS-11FS
Male flange
Gas through
105D-120D-WMP-10FS
Female flange
Gas through
105D-120D-WFP-10RS
Coupling
Gas barrier
105D-120D-WGS-11NFS
Male flange
Gas through
105D-77D-WMP-10FS
Female flange
Gas through
105D-77D-WFP-10RS
Coupling
Gas barrier
105D-77D-WGS-11NFS
Factor (K)
Standard
Amb. 50℃
Frequency Attenuation Average power Average power
(MHz)
(dB/100m) (kW)
(kW)
1.2
1
0.8
0.2
0
0
20
40
60
Temperature
80
100
Factor (K) of Ambient temperature and Average power
P=PoxK
Po: Ambient temperature 40ºC & 50ºC
P: Ambient temperature TºC
K: Factor K=(115-T)/75 Po=40℃ (Blue line)
K=(115-T)/65 Po=50℃ (Red line)
7
HF-100D
4"
Air dielectric coaxial cable
Structure
Item
Diameter (mm)
Materials
Inner conductor
38.2
Corrugated copper
Insulator
84
Polyethylene
Outer conductor
94.6
Corrugated copper
Jacket
100
Polyethylene, Black
Mechanical Characteristics
Item
Specification
Cable weight
3.7 kg/m
Minimum bending radius
Single
450 mm
Repeated
1000 mm
Tensile strength
3000 N
Flat plate crush strength
2500 N/50mm
Amb. 40℃
Electrical Characteristics
Item
Specification
Impedance
50 Ω
Velocity
96 %
Direct current resistance
(Loop resistance)
55 mΩ/100m
Insulation resistance
1000 MΩ-km
Peak voltage
10000 V
Peak power rating
1000 kW
Jacket spark
8000 V RMS
Maximum frequency
1400 MHz
V.S.W.R.
Frequency range (MHz) Specified channel Specified band ( *1) Within range
10 - 30
-
1.05
-
30 - 230
1.05
1.05
1.10
230 - 470
-
1.10
-
470 - 770
1.05
1.05
1.10
770 - 960
1.05
1.10
1.15
*1: Less than 30MHz band
0.5
0.0223
945
790
1
0.0315
665
558
10
0.101
210
175
30
0.177
120
100
50
0.23
92.5
77.4
100
0.33
64.9
54.3
200
0.475
45.2
37.8
300
0.59
36.5
30.6
400
0.67
31.4
26.3
500
0.78
27.9
23.3
600
0.865
25.3
21.2
700
0.94
23.3
19.45
800
1.02
21.6
18.10
900
1.085
20.3
17.00
1000
1.15
19.15
16.05
Condition
1) Attenuation
• Ambient temperature 20ºC, Nominal value
2) Average power
• Ambient temperature 40ºC & 50ºC
• Inner conductor temperature 115ºC
• V.S.W.R.=1.0
Accessories
2
Connector / Flange type
EIA 6-1/8"
IEC 4-1/2”
EIA 3-1/8”
JEITA
BFX-120D
JEITA
BFX-77D
8
1.8
Structure
1.6
Type
1.4
Female flange
Gas through
100D-152D-EFP-11FS
Female flange
Gas barrier
100D-152D-EFS-11FS
Female flange
Gas through
100D-IFP-11FS
Female flange
Gas barrier
100D-IFS-11FS
0.6
Female flange
Gas through
100D-77D-EFP-11FS
0.4
Female flange
Gas barrier
100D-77D-EFS-11FS
Male flange
Gas through
100D-120D-WMP-10FS
Female flange
Gas through
100D-120D-WFP-10RS
Coupling
Gas barrier
100D-120D-WGS-11NFS
Male flange
Gas through
100D-77D-WMP-10FS
Female flange
Gas through
100D-77D-WFP-10RS
Coupling
Gas barrier
100D-77D-WGS-11NFS
Factor (K)
Standard
Amb. 50℃
Frequency Attenuation Average power Average power
(MHz)
(dB/100m) (kW)
(kW)
1.2
1
0.8
0.2
0
0
20
40
60
Temperature
Factor (K) of Ambient temperature and Average power
P=PoxK
Po: Ambient temperature 40ºC & 50ºC
P: Ambient temperature TºC
K: Factor K=(115-T)/75 Po=40℃ (Blue line)
K=(115-T)/65 Po=50℃ (Red line)
80
100
HF-77D
3-1/8"
Air dielectric coaxial cable
Structure
Item
Diameter (mm)
Materials
Inner conductor
33
Corrugated copper
Insulator
71
Polyethylene
Outer conductor
81
Corrugated copper
Jacket
88
Polyethylene, Black
Mechanical Characteristics
Item
Specification
Cable weight
3.0 kg/m
Minimum bending radius
Single
400 mm
Repeated
800 mm
Tensile strength
3000 N
Flat plate crush strength
2000 N/50mm
Amb. 40℃
Electrical Characteristics
Item
Specification
Impedance
50 Ω
Velocity
96 %
Direct current resistance
(Loop resistance)
60 mΩ/100m
Insulation resistance
1000 MΩ-km
Peak voltage
9700 V
Peak power rating
940 kW
Jacket spark
8000 V RMS
Maximum frequency
1550 MHz
V.S.W.R.
Frequency range (MHz) Specified channel Specified band ( *1) Within range
10 - 30
-
1.05
-
30 - 230
1.05
1.05
1.10
230 - 470
-
1.10
-
470 - 770
1.05
1.05
1.10
770 - 960
1.05
1.10
1.15
*1: Less than 60MHz band
0.5
0.026
740
645
1
0.04
523
455
10
0.12
165
143
30
0.21
93.5
81.5
50
0.27
72.5
63.0
100
0.39
50.5
44.0
200
0.56
35.5
31.0
300
0.68
29.0
25.0
400
0.80
25.0
21.5
500
0.90
22.4
19.5
600
0.99
20.5
17.8
700
1.10
19.0
16.5
800
1.20
17.8
15.5
900
1.25
16.7
14.6
1000
1.30
15.9
13.8
1500
1.65
13.2
11.5
Condition
1) Attenuation
• Ambient temperature 20ºC, Nominal value
2) Average power
• Ambient temperature 40ºC & 50ºC
• Inner conductor temperature 115ºC
• V.S.W.R.=1.0
Accessories
2
Connector / Flange type
EIA 3-1/8"
JEITA
BFX-77D
1.8
Structure
1.6
Type
1.4
Female flange
Gas through
77D-EFP-11FS
Female flange
Gas barrier
77D-EFS-11FS
Male flange
Gas through
77D-WMP-10FS
Female flange
Gas through
77D-WFP-10RS
0.6
Coupling
Gas barrier
77D-WGS-11NFS
0.4
Factor (K)
Standard
Amb. 50℃
Frequency Attenuation Average power Average power
(MHz)
(dB/100m) (kW)
(kW)
1.2
1
0.8
0.2
0
0
20
40
60
Temperature
80
100
Factor (K) of Ambient temperature and Average power
P=PoxK
Po: Ambient temperature 40ºC & 50ºC
P: Ambient temperature TºC
K: Factor K=(115-T)/75 Po=40℃ (Blue line)
K=(115-T)/65 Po=50℃ (Red line)
9
HF-70D
3"
Air dielectric coaxial cable
Structure
Item
Diameter (mm)
Materials
Inner conductor
30.1
Corrugated copper
Insulator
65
Polyethylene
Outer conductor
74
Corrugated copper
Jacket
79
Polyethylene, Black
Mechanical Characteristics
Item
Specification
Cable weight
2.5 kg/m
Minimum bending radius
Single
300 mm
Repeated
750 mm
Tensile strength
2500 N
Flat plate crush strength
2000 N/50mm
Amb. 40℃
Electrical Characteristics
Item
Specification
Impedance
50 Ω
Velocity
96 %
Direct current resistance
(Loop resistance)
62 mΩ/100m
Insulation resistance
1000 MΩ-km
Peak voltage
7600 V
Peak power rating
578 kW
Jacket spark
8000 V RMS
Maximum frequency
1800 MHz
V.S.W.R.
Frequency range (MHz) Specified channel Specified band ( *1) Within range
10 - 30
-
1.05
-
30 - 230
1.05
1.05
1.10
230 - 470
-
1.10
-
470 - 770
1.05
1.05
1.10
770 - 960
1.05
1.10
1.15
*1: Less than 60MHz band
Accessories
Connector / Flange type
EIA 3-1/8"
JEITA
BFX-77D
Structure
0.5
1
10
30
50
88
100
108
174
200
230
300
400
500
600
700
800
900
960
1000
1500
0.028
0.040
0.125
0.220
0.285
0.381
0.407
0.424
0.544
0.586
0.631
0.727
0.849
0.958
1.06
1.15
1.24
1.33
1.38
1.41
1.77
578
436
137
78.6
60.6
45.4
42.5
40.9
31.9
29.7
27.6
24.1
20.7
18.4
16.7
15.3
14.3
13.4
12.9
12.7
10.1
526
372
117
67
51.7
38.7
36.2
34.8
27.2
25.3
23.6
20.5
17.6
15.7
14.2
13.1
12.2
11.4
11
10.8
8.7
Condition
1) Attenuation
• Ambient temperature 20ºC, Nominal value
2) Average power
• Ambient temperature 40ºC & 50ºC
• Inner conductor temperature 115ºC
• V.S.W.R.=1.0
Type
2
Female flange
Gas through
70D-EFP-11FS
1.8
Female flange
Gas barrier
70D-EFS-11FS
1.6
Male flange
Gas through
70D-WMP-10FS
1.4
Female flange
Gas through
70D-WFP-10RS
Coupling
Gas barrier
70D-WGS-11NFS
Factor (K)
Standard
Amb. 50℃
Frequency Attenuation Average power Average power
(MHz)
(dB/100m) (kW)
(kW)
1.2
1
0.8
0.6
0.4
0.2
0
0
10
20
40
60
Temperature
Factor (K) of Ambient temperature and Average power
P=PoxK
Po: Ambient temperature 40ºC & 50ºC
P: Ambient temperature TºC
K: Factor K=(115-T)/75 Po=40℃ (Blue line)
K=(115-T)/65 Po=50℃ (Red line)
80
100
HF-50D
2-1/4"
Air dielectric coaxial cable
Structure
Item
Diameter (mm)
Materials
Inner conductor
21.7
Corrugated copper
Insulator
47.5
Polyethylene
Outer conductor
55.5
Corrugated copper
Jacket
60
Polyethylene, Black
Mechanical Characteristics
Item
Specification
Cable weight
2 kg/m
Minimum bending radius
Single
300 mm
Repeated
700 mm
Tensile strength
2500 N
Flat plate crush strength
2500 N/50mm
Amb. 40℃
Electrical Characteristics
Item
Specification
Impedance
50 Ω
Velocity
95 %
Direct current resistance
(Loop resistance)
100 mΩ/100m
Insulation resistance
1000 MΩ-km
Peak voltage
6300 V
Peak power rating
397 kW
Jacket spark
8000 V RMS
Maximum frequency
2500 MHz
V.S.W.R.
Frequency range (MHz) Specified channel Specified band ( *1) Within range
10 - 30
-
1.05
-
30 - 230
1.05
1.05
1.10
230 - 470
-
1.10
-
470 - 770
1.05
1.05
1.10
770 - 960
1.05
1.10
1.15
960 - 1400
-
1.10
1.15
1400 - 1700
-
1.10
1.15
1700 - 2300
-
1.10
1.15
0.5
0.038
330
285
1
0.055
232
200
10
0.175
72.5
63
30
0.305
41.5
36
50
0.395
32.0
27.5
100
0.565
22.0
19.0
200
0.85
15.5
13.5
300
1.05
12.5
10.5
400
1.25
10.5
9.20
500
1.4
9.40
8.15
600
1.55
8.55
7.40
700
1.65
7.85
6.75
800
1.75
7.25
6.30
900
2
6.80
5.90
1000
2.1
6.40
5.55
2000
3.05
4.30
3.75
2500
3.5
3.80
3.30
Condition
1) Attenuation
• Ambient temperature 20ºC, Nominal value
2) Average power
• Ambient temperature 40ºC & 50ºC
• Inner conductor temperature 115ºC
• V.S.W.R.=1.0
*1: Less than 60MHz band
2
1.8
Accessories
1.6
Connector / Flange type
EIA 3-1/8"
EIA 1-5/8"
EIA 7/8"
N type
JEITA
BFX-20D
Structure
Type
Female flange
Gas through
50D-77D-EFP-11FS
Female flange
Gas barrier
50D-77D-EFS-11FS
Female flange
Gas through
50D-39D-EFP-11FS
Female flange
Gas barrier
50D-39D-EFS-11FS
Female flange
Gas through
50D-20D-EFP-11FS
Female flange
Gas barrier
50D-20D-EFS-11FS
Male
Gas barrier
50D-NP-11S
Female
Gas barrier
50D-NJ-11S
Male flange
Gas through
50D-20D-WMP-10FS
Female flange
Gas through
50D-20D-WFP-10RS
1.4
Factor (K)
Standard
Amb. 50℃
Frequency Attenuation Average power Average power
(MHz)
(dB/100m) (kW)
(kW)
1.2
1
0.8
0.6
0.4
0.2
0
0
20
40
60
Temperature
80
100
Factor (K) of Ambient temperature and Average power
P=PoxK
Po: Ambient temperature 40ºC & 50ºC
P: Ambient temperature TºC
K: Factor K=(115-T)/75 Po=40℃ (Blue line)
K=(115-T)/65 Po=50℃ (Red line)
11
HF-39D
1-5/8"
Air dielectric coaxial cable
Structure
Item
Diameter (mm)
Materials
Inner conductor
17.2
Copper tube
Insulator
39.6
Polyethylene
Outer conductor
46.3
Corrugated copper
Jacket
51
Polyethylene, Black
Mechanical Characteristics
Item
Specification
Cable weight
1.9 kg/m
Minimum bending radius
Single
200 mm
Repeated
600 mm
Tensile strength
2000 N
Flat plate crush strength
2000 N/50mm
Amb. 40℃
Electrical Characteristics
Item
Specification
Impedance
50 Ω
Velocity
91 %
Direct current resistance
(Loop resistance)
65 mΩ/100m
Insulation resistance
1000 MΩ-km
Peak voltage
5200 V
Peak power rating
270 kW
Jacket spark
8000 V RMS
Maximum frequency
2900 MHz
Amb. 50℃
Frequency Attenuation Average power Average power
(MHz)
(dB/100m) (kW)
(kW)
V.S.W.R.
Frequency range (MHz) Specified channel Specified band ( *1) Within range
10 - 30
-
1.05
-
30 - 230
1.05
1.05
1.10
230 - 470
-
1.10
-
470 - 770
1.05
1.05
1.10
770 - 960
1.05
1.10
1.15
960 - 1400
-
1.10
1.15
1400 - 1700
-
1.10
1.15
1700 - 2300
-
1.10
1.15
2300 - 2700
-
1.10
1.15
0.5
0.046
255
222
1
0.065
186
161
10
0.21
58.5
50.5
30
0.37
33.5
29.0
50
0.48
26.0
22.5
100
0.69
18.2
15.5
200
1.01
12.8
11.1
300
1.3
10.35
8.95
400
1.53
8.95
7.75
500
1.77
7.95
6.90
600
1.97
7.25
6.25
700
2.15
6.70
5.80
800
2.34
6.25
5.40
900
2.51
5.85
5.10
1000
2.7
5.55
4.80
2000
4.1
3.90
3.35
2500
4.9
3.45
2.99
Condition
1) Attenuation
• Ambient temperature 20ºC, Nominal value
2) Average power
• Ambient temperature 40ºC & 50ºC
• Inner conductor temperature 115ºC
• V.S.W.R.=1.0
2
*1: Less than 60MHz band
1.8
1.6
Accessories
Standard
EIA 1-5/8"
EIA 7/8"
JEITA
BFX-39D
12
Structure
Type
Female flange
Gas through
39D-EFP-10RZ
Female flange
Gas barrier
39D-EFS-11RZ
Female flange
Gas through
39D-20D-EFP-10RZ
Female flange
Gas barrier
39D-20D-EFS-11RZ
Male flange
Gas through
39D-WMP-10FS
Female flange
Gas through
39D-WFP-10RS
Coupling
Gas barrier
39D-WGS-11NFS
Factor (K)
1.4
Connector / Flange type
1.2
1
0.8
0.6
0.4
0.2
0
0
20
40
60
Temperature
Factor (K) of Ambient temperature and Average power
P=PoxK
Po: Ambient temperature 40ºC & 50ºC
P: Ambient temperature TºC
K: Factor K=(115-T)/75 Po=40℃ (Blue line)
K=(115-T)/65 Po=50℃ (Red line)
80
100
HF-39DB
1-5/8"
Air dielectric coaxial cable
Structure
Item
Diameter (mm)
Materials
Inner conductor
18.5
Corrugated copper
Insulator
39.8
Polyethylene
Outer conductor
46.3
Corrugated copper
Jacket
51
Polyethylene, Black
Mechanical Characteristics
Item
Specification
Cable weight
1.3 kg/m
Minimum bending radius
Single
200 mm
Repeated
600 mm
Tensile strength
1500 N
Flat plate crush strength
1200 N/50mm
Amb. 40℃
Electrical Characteristics
Item
Specification
Impedance
50 Ω
Velocity
94 %
Direct current resistance
(Loop resistance)
110 mΩ/100m
Insulation resistance
1000 MΩ-km
Peak voltage
5200 V
Peak power rating
270 kW
Jacket spark
8000 V RMS
Maximum frequency
2900 MHz
V.S.W.R.
Frequency range (MHz) Specified channel Specified band ( *1) Within range
10 - 30
-
1.05
-
30 - 230
1.05
1.05
1.10
230 - 470
-
1.10
-
470 - 770
1.05
1.05
1.10
770 - 960
1.05
1.10
1.15
960 - 1400
-
1.10
1.15
1400 - 1700
-
1.10
1.15
1700 - 2300
-
1.10
1.15
2300 - 2700
-
1.10
1.15
*1: Less than 60MHz band
0.5
0.045
270
245
1
0.064
200
170
10
0.204
62
53.5
30
0.341
36
31
50
0.444
27.5
24
88
0.596
21.2
18.35
100
0.638
19.85
17.2
108
0.664
19.1
16.55
174
0.858
14.95
12.95
200
0.923
13.93
12.06
300
1.15
11.25
9.76
400
1.35
9.84
8.36
500
1.52
8.55
7.42
600
1.68
7.75
6.74
700
1.84
7.13
6.19
800
1.98
6.64
5.76
900
2.12
6.22
5.4
1000
2.28
5.87
5.09
2000
3.38
4.00
3.46
2500
3.86
3.56
3.05
Condition
1) Attenuation
• Ambient temperature 20ºC, Nominal value
2) Average power
• Ambient temperature 40ºC & 50ºC
• Inner conductor temperature 115ºC
• V.S.W.R.=1.0
Accessories
2
Connector / Flange type
EIA 1-5/8"
EIA 7/8"
JEITA
BFX-39D
1.8
Structure
1.6
Type
1.4
Female flange
Gas through
39DB-EFP-11FS
Female flange
Gas barrier
39DB-EFS-11FS
Female flange
Gas through
39DB-20D-EFP-11FS
Female flange
Gas barrier
39DB-20D-EFS-11FS
0.6
Male flange
Gas through
39DB-WMP-10FS
0.4
Female flange
Gas through
39DB-WFP-10RS
0.2
Coupling
Gas barrier
39DB-WGS-11NFS
Factor (K)
Standard
Amb. 50℃
Frequency Attenuation Average power Average power
(MHz)
(dB/100m) (kW)
(kW)
1.2
1
0.8
0
0
20
40
60
Temperature
Factor (K) of Ambient temperature and Average power
P=PoxK
Po: Ambient temperature 40ºC & 50ºC
P: Ambient temperature TºC
K: Factor K=(115-T)/75 Po=40℃ (Blue line)
K=(115-T)/65 Po=50℃ (Red line)
80
100
13
HF-20D
7/8"
Air dielectric coaxial cable
Structure
Item
Diameter (mm)
Materials
Inner conductor
8.97
Copper tube
Insulator
19.8
Polyethylene
Outer conductor
25.8
Corrugated copper
Jacket
30
Polyethylene, Black
Mechanical Characteristics
Item
Specification
Cable weight
0.9 kg/m
Minimum bending radius
Single
100 mm
Repeated
350 mm
Tensile strength
900 N
Flat plate crush strength
1000 N/50mm
Amb. 40℃
Electrical Characteristics
Item
Specification
Impedance
50 Ω
Velocity
91 %
Direct current resistance
(Loop resistance)
155 mΩ/100m
Insulation resistance
1000 MΩ-km
Peak voltage
2700 V
Peak power rating
73 kW
Jacket spark
8000 V RMS
Maximum frequency
5600 MHz
V.S.W.R.
Frequency range (MHz) Specified channel Specified band ( *1) Within range
10 - 30
-
1.05
-
30 - 230
1.05
1.05
1.10
230 - 470
-
1.10
-
470 - 770
1.05
1.05
1.10
770 - 960
1.05
1.10
1.15
960 - 1400
-
1.10
1.15
1400 - 1700
-
1.10
1.15
1700 - 2300
-
1.10
1.15
2300 - 2700
-
1.10
1.15
2700 - 3400
-
1.20
-
0.5
0.086
73
73
1
0.125
73
73
10
0.39
27.3
23.5
30
0.68
15.7
13.6
50
0.89
12.1
10.5
100
1.25
8.50
7.35
200
1.82
5.95
5.15
300
2.29
4.80
4.20
400
2.68
4.15
3.60
500
3.02
3.70
3.20
600
3.35
3.35
2.90
700
3.64
3.10
2.70
800
3.92
2.90
2.50
900
4.2
2.70
2.35
1000
4.45
2.55
2.20
2000
6.7
1.80
1.55
3000
8.6
1.45
1.25
4000
10.5
1.20
1.05
5000
12
1.10
0.95
Condition
1) Attenuation
• Ambient temperature 20ºC, Nominal value
2) Average power
• Ambient temperature 40ºC & 50ºC
• Inner conductor temperature 115ºC
• V.S.W.R.=1.0
*1: Less than 60MHz band
2
1.8
Accessories
1.6
Connector / Flange type
EIA 7/8"
N type
DIN type
JEITA
BFX-20D
14
1.4
Structure
Type
Female flange
Gas through
20D-EFP-10RZ
Female flange
Gas barrier
20D-EFS-11RZ
Male
Gas barrier
20D-NP-11S
Female
Gas barrier
20D-NJ-11S
Male
Gas barrier
20D-DP-11S
Female
Gas barrier
20D-DJ-11S
Male flange
Gas through
20D-WMP-10RS
Female flange
Gas through
20D-WFP-10RS
Coupling
Gas barrier
20D-WGS-11NFS
Factor (K)
Standard
Amb. 50℃
Frequency Attenuation Average power Average power
(MHz)
(dB/100m) (kW)
(kW)
1.2
1
0.8
0.6
0.4
0.2
0
0
20
40
60
Temperature
Factor (K) of Ambient temperature and Average power
P=PoxK
Po: Ambient temperature 40ºC & 50ºC
P: Ambient temperature TºC
K: Factor K=(115-T)/75 Po=40℃ (Blue line)
K=(115-T)/65 Po=50℃ (Red line)
80
100
HF-15D
5/8"
Air dielectric coaxial cable
Structure
Item
Diameter (mm)
Materials
Inner conductor
6.3
Copper wire
Insulator
13.6
Polyethylene
Outer conductor
18.9
Corrugated copper
Jacket
23
Polyethylene, Black
Mechanical Characteristics
Item
Specification
Cable weight
0.75 kg/m
Minimum bending radius
Single
80 mm
Repeated
250 mm
Tensile strength
900 N
Flat plate crush strength
1000 N/50mm
Amb. 40℃
Electrical Characteristics
Item
Specification
Impedance
50 Ω
Velocity
90 %
Direct current resistance
(Loop resistance)
180 mΩ/100m
Insulation resistance
1000 MΩ-km
Peak voltage
1800 V
Peak power rating
32 kW
Jacket spark
8000 V RMS
Maximum frequency
7600 MHz
V.S.W.R.
Frequency range (MHz) Specified channel Specified band ( *1) Within range
10 - 30
-
1.05
-
30 - 230
1.05
1.05
1.10
230 - 470
-
1.10
-
470 - 770
1.05
1.05
1.10
770 - 960
1.05
1.10
1.15
960 - 1400
-
1.10
1.15
1400 - 1700
-
1.10
1.15
1700 - 2300
-
1.10
1.15
2300 - 2700
-
1.10
1.15
2700 - 5000
-
1.20
-
0.5
0.12
32
32
1
0.17
32
28
10
0.54
15
13
30
0.94
8.75
7.50
50
1.22
6.75
5.85
100
1.75
4.75
4.10
200
2.50
3.35
2.90
300
3.10
2.70
2.35
400
3.60
2.35
2.00
500
4.00
2.05
1.80
600
4.50
1.90
1.65
700
4.85
1.75
1.52
800
5.20
1.63
1.41
900
5.55
1.55
1.33
1000
5.90
1.45
1.25
2000
8.55
0.98
0.85
3000
10.75
0.81
0.70
4000
12.70
0.69
0.60
5000
14.50
0.575
0.50
Condition
1) Attenuation
• Ambient temperature 20ºC, Nominal value
2) Average power
• Ambient temperature 40ºC & 50ºC
• Inner conductor temperature 115ºC
• V.S.W.R.=1.0
*1: Less than 60MHz band
2
1.8
Accessories
1.6
Connector / Flange type
EIA 7/8"
N type
DIN type
1.4
Structure
Type
Female flange
Gas through
15D-EFP-10RZ
Female flange
Gas barrier
15D-EFS-11RZ
Male
Gas barrier
15D-NP-11S
Female
Gas barrier
15D-NJ-11S
Male
Gas barrier
15D-DP-11S
Female
Gas barrier
15D-DJ-11S
Factor (K)
Standard
Amb. 50℃
Frequency Attenuation Average power Average power
(MHz)
(dB/100m) (kW)
(kW)
1.2
1
0.8
0.6
0.4
0.2
0
0
20
40
60
Temperature
Factor (K) of Ambient temperature and Average power
P=PoxK
Po: Ambient temperature 40ºC & 50ºC
P: Ambient temperature TºC
K: Factor K=(115-T)/75 Po=40℃ (Blue line)
K=(115-T)/65 Po=50℃ (Red line)
80
100
15
CLAMP
Accessories
Clamp type B
Cable
Dimension (mm)
Type
Draw
A
W
L
M
7/8"
HCC-20D-B1
70
20
130
M10
HF-39D
1-5/8"
HCC-39D-B1
90
25
140
M12
HF-50D
2-1/4"
HCC-50D-B1
100
25
120
M12
HF-70D
3"
HCC-70D-B1
130
32
130
M12
HF-77D
3-1/8"
HCC-77D-B1
140
32
120
M12
HF-100D
4"
HCC-100D-B1
170
40
150
M16
HF-105D
5"
HCC-105D-B1
185
40
150
M16
HF-120D
5-1/2"
HCC-120D-B1
230
55
170
M16
HF-152D
6-1/8"
HCC-152D-B1
250
60
210
M20
Draw
Draw
W
A
Holes are required in the steel frame to insert and fasten this
type of clamp.
W
HF-20D
A
CLAMP BAND
BAND (1)
BOLTS
BOLT
BAND (2)
STAND BOLTS
L
L
STAND BOLT
110
NUTS, SPRING WASHER
M
M
Clamp type C2
Cable
Type
Dimension (mm)
A
W
B
C
HF-20D
7/8"
HCC-20D-C2
45
20
40
30
HF-39D
1-5/8"
HCC-39D-C2
77
25
50
30
HF-50D
2-1/4"
HCC-50D-C2
85
25
75
40
HF-70D
3"
HCC-70D-C2
110
32
85
46
HF-77D
3-1/8"
HCC-77D-C2
120
32
90
46
HF-100D
4"
HCC-100D-C2
145
40
100
46
HF-105D
5"
HCC-105D-C2
160
40
105
46
This type of clamp can be directly fastened to the steel frame
without holes.
Clamp can be used upright or the top of the clamp can be
A
B
BAND
C
CLEAT
16
W
detached and fastened side ways.
Accessories
CLAMP
Clamp type C3 Cable
Dimension (mm)
Type
φD
W
A
B
HF-20D
7/8"
HCC-20D-C3
φ28
30
53
45
HF-39D
1-5/8"
HCC-39D-C3
φ50
38
83
45
HF-50D
2-1/4"
HCC-50D-C3
φ60
38
94
45
HF-70D
3"
HCC-70D-C3
φ79
38
114
45
HF-77D
3-1/8"
HCC-77D-C3
φ87
38
123
45
HF-100D
4"
HCC-100D-C3
φ102
43
134
45
HF-105D
5"
HCC-105D-C3
φ117
43
149
45
This type of clamp can be directly fastened to the steel frame
without holes.
Clamp can be used upright or the top of the clamp can be
detached and fastened side ways.
W
BAND
A
φD
B
CLEAT
Recommended clamp spacing
Cable
B1 type
C2 type
C3 type
HF-20D
7/8"
1.0
1.0
2.0
HF-39D
1-5/8"
1.5
2.0
2.0
HF-50D
2-1/4"
2.0
2.0
2.0
HF-70D
3"
2.0
2.0
1.5
HF-77D
3-1/8"
2.0
2.0
1.0
HF-100D
4"
2.0
1.5
1.5
HF-105D
5"
2.0
1.5
1.0
HF-120D
5-1/2"
2.0
-
-
HF-152D
6-1/8"
2.0
-
-
Recommended clamp space is shown in the above table. (terms: wind speed 60m/s)
Please choose an appropriate clamp space according to the wind speed condition.
Maximum clamp space according to the wind speed condition
B1 type clamp
Wind speed (m/s)
Cable
C2 type clamp
Wind speed (m/s)
C3 type clamp
Wind speed (m/s)
40
50
60
70
40
50
60
70
40
50
60
70
HF-20D
7/8"
1.2
1.1
1.0
0.9
1.2
1.1
1.0
0.8
2.0
2.0
2.0
2.0
HF-39D
1-5/8"
1.4
1.3
1.5
1.5
2.5
2.0
2.0
1.5
2.0
2.0
2.0
2.0
HF-50D
2-1/4"
3.0
2.5
2.0
1.5
3.0
2.5
2.0
1.5
2.0
2.0
2.0
2.0
HF-70D
3"
3.0
2.5
2.0
1.4
3.0
3.0
2.0
1.5
2.0
2.0
1.5
1.0
HF-77D
3-1/8"
3.0
2.5
2.0
1.4
3.0
3.0
2.0
1.5
2.0
1.5
1.0
0.5
HF-100D
4"
3.0
2.5
2.0
1.5
2.5
2.0
1.5
1.0
2.0
1.5
1.5
1.0
HF-105D
5”
3.0
2.5
2.0
1.5
2.5
2.0
1.5
1.0
2.0
1.5
1.0
1.0
HF-120D
5-1/2"
3.0
2.5
2.0
1.4
-
-
-
-
-
-
-
-
HF-152D
6-1/8"
4.0
3.0
2.0
1.5
-
-
-
-
-
-
-
-
17
EARTHING KIT
Accessories
Type N
2-M5 (STAINLESS)
Type
L
HF-20D
7/8"
GB-20D-N
35
HF-39D
1-5/8"
GB-39D-N
35
HF-50D
2-1/4"
GB-50D-N
35
HF-70D
3"
GB-70D-N
35
HF-77D
3-1/8"
GB-77D-N
35
HF-100D
4"
GB-100D-N
65
HF-105D
5"
GB-105D-N
65
HF-120D
5-1/2"
GB-120D-N
65
HF-152D
6-1/8"
GB-152D-N
75
WATER PROOF TAPE
BRIDED COPPER STRIP
TIGHTENING CLAMP
L
Cable
Dimension
GROUNDING WIRE
ADHESIVE PVC TAPE
Approx,1000
Caution
1. Length of the grounding wire is fixed with the copper terminal already attached.
2. Please prepare water proof tape and adhesive PVC tape on your own.
3. Water proof tape and adhesive PVC tape are separately sold material.
4. Please contact us when you difficult to purchase the material on your country.
Type A
Cable
Dimension (mm)
Type
L
HF-20D
7/8"
GB-20D
60
HF-39D
1-5/8"
GB-39D
60
HF-50D
2-1/4"
GB-50D
80
HF-70D
3"
GB-70D
100
HF-77D
3-1/8"
GB-77D
100
HF-100D
4"
GB-100D
125
HF-105D
5"
GB-105D
125
HF-120D
5-1/2"
GB-120D
150
HF-152D
6-1/8"
GB-152D
200
GB-203D
250
HF-203D-S 8"
Construction of Clamping band
EARTHING KIT
SELF-BONDING TAPE
ADHESIVE PVC TAPE
APPROX
L
CABLE
CLAMPING BAND
COPPER STRANDED WIRE
(22mm2)
18
17
COPPER
TERMINAL
CONPOUND
Length of the copper strand wire is adjustable.
Copper terminal needs to be attached at the end of the wire
separately.
WALL GLAND
Accessories
Type A, Single run
10-M10 BOLTS
Type
(STAINLESS)
ADHESIVE PVC TAPE
7/8"
WMS-20D-1A
ADHESIVE ALUMINIUM TAPE
HF-39D
1-5/8"
WMS-39D-1A
SELF-BONDING TAPE
HF-50D
2-1/4"
WMS-50D-1A
HF-77D
3-1/8"
WMS-77D-1A
HF-105D
5"
WMS-105D-1A
HF-120D
5-1/2"
WMS-120D-1A
HF-152D
6-1/8"
WMS-152D-1A
20
300
130
130
20
20
HF-20D
COMPOUND
HF CABLE
300
130
ADHESIVE AGENT
130
ADAPTOR
CLAMPING BAND
GASKET
60
Cable
(STAINLESS)
This wall gland can be assembled sandwich the cable after it
has been threaded before being attached to the wall.
20
PLATE
Type A, Dual run
Cable
Dimension (mm)
Type
Draw
P
HF-20D
7/8"
WMS-20D-2A
160
HF-39D
1-5/8"
WMS-39D-2A
200
HF-50D
2-1/4"
WMS-50D-2A
200
HF-77D
3-1/8"
WMS-77D-2A
200
HF-105D
5"
WMS-105D-2A
400
HF-120D
5-1/2"
WMS-120D-2A
400
HF-152D
6-1/8"
WMS-152D-2A
440
Draw
Draw
BOLTS(12-M10)
(STAINLESS)
ADHESIVE PVC TAPE
14-M10 BOLTS
(STAINLESS)
ADHESIVE ALUMINIUM TAPE
SELF-BONDING TAPE
20
20
P
COMPOUND
100
60
100
P
80
100
80
20
20
300
110
120
120
110
20
P
PLATE
18-M10 BOLTS
(STAINLESS)
1
2
3
4
5
10-M6 BOLTS
φ222
60
150
φ174
SUS BAND
2
3
5
COMPOUND
SELF BONDING TAPE
ADHESIVE ALUMINIUM TAPE
ADHESIVE VINYL TAPE
ADHESIVE AGENT
400
5
20
φ
20
GASKET
4
150
20
235
200
1
GASKET
500
Draw
40
CLAMPING BAND
(STAINLESS)
ADAPTOR
20
20
50
φ56
20
ADHESIVE AGENT
300
60
200
50
φ72
20
150
150
130
130
150
150
20
900
19
Accessories
WALL GLAND
Type 1C, Single run
Cable
Dimension (mm)
Type
Draw
D1
D2
L
P
Bolts
HF-20D
7/8"
WMS-20D-1C
130
80
50
110
8-M5
HF-39D
1-5/8"
WMS-39D-1C
130
80
50
110
8-M5
HF-50D
2-1/4"
WMS-50D-1C
130
80
50
110
8-M5
HF-70D
3"
WMS-70D-1C
200
130
80
170
8-M10
HF-77D
3-1/8"
WMS-77D-1C
200
130
80
170
8-M10
HF-100D
4"
WMS-100D-1C
230
160
80
200
8-M10
HF-105D
5"
WMS-105D-1C
230
160
80
200
8-M10
HF-120D
5-1/2"
WMS-120D-1C
260
190
90
230
8-M10
HF-152D
6-1/8"
WMS-152D-1C
285
210
95
260
8-M10
This wall gland must be attached to the wall before the cable can be threaded.
Draw
φ80
φD2
Draw
50
PLATE
MOLDED RUBBER
(STAINLESS)
BOLTS (M5)
(STAINLESS)
MOLDED RUBBER
STAINLESS BAND
φ130
10
φ1
20
HF CABLE
PLATE
(STAINLESS)
L
HF CABLE
BOLTS (M10)
(STAINLESS)
φD1
φP
STAINLESS BAND
Accessories
HOISTING STOCKING
Hoisting Stocking
Cable
Type
Dimension(mm)
L1
L2
Rd
HF-20D
7/8"
HSC-20D
690
390
R20
HF-39D
1-5/8"
HSC-39D
820
520
R20
HF-50D
2-1/4"
HSC-50D
860
560
R20
HF-70D
3"
HSC-70D
940
640
R20
HF-77D
3-1/8"
HSC-77D
940
640
R20
HF-100D
4"
HSC-100D
1350
1050
R20
HF-105D
5"
HSC-105D
1350
1050
R20
HF-120D
5-1/2"
HSC-120D
1550
1150
R20
HF-152D
6-1/8"
HSC-152D
1700
1250
R20
Rd
Material: Stainless wire (stocking)
Aluminum (sleeve)
HOISTING STOCKING
L2
L1
This product is used for pulling the cable up during installation.
CLAMPING BAND
HF CABLE
Fixing use
Dimension(mm)
Cable
Type
L1
L2
HF-20D
7/8"
HSF-20D
450
300
HF-39D
1-5/8"
HSF-39D
600
400
HF-50D
2-1/4"
HSF-50D
780
520
HF-70D
3"
HSF-70D
910
700
HF-77D
3-1/8"
HSF-77D
910
700
HF-100D
4"
HSF-100D
1350
900
HF-105D
5"
HSF-105D
1350
900
HF-120D
5-1/2"
HSF-120D
1800
1200
HF-152D
6-1/8"
HSF-152D
1800
1200
Bolt (M16)
Eyebolt (M16)
TURN BUCKLES
Material: Stainless wire (stocking, clamping band)
Galvanized steel (eyebolt, turn buckle)
This product is used for fixing cable to the tower.
Recommended fixation interval is 50m on the vertical part of the tower. Loosening or
HOISTING STOCKING
L2
L1
tightening the turnbuckles can adjust the tautness of the hoisting stocking.
CLAMPING BAND
HF CABLE
21
Accessories
CONNECTOR and TOOL
Connector
Cable
Type
HF-20D
7/8"
HF-39D
1-5/8"
HF-39DB
1-5/8"
HF-50D
2-1/4"
HF-70D
3"
HF-77D
3-1/8"
HF-100D
4"
HF-105D
5"
HF-120D
5-1/2"
HF-152D
6-1/8"
See each cable sheet
HF-203D-S 8"
The structure of the trade type name of connector
(1) Flange interface connector
39D − EFP − 10FS
Cable size and flange size is same.
Cable size
Outer conductor size in mm, D means 50Ω
Standard of Flange
E:EIA I:IEC W:JEITA
Inner conductor
F:Female M:Male
Gas pass/stop
P:Gas pass S:Gas stop
Gas inlet exist or not
10:Inlet non 11:Inlet exist
Flange swivel or not
F:Not swivel R:Swivle flange
Inner conductor assemble
S:Taper nut lock Z:Screw lock
(2) Flange interface reducer type connector
3 9 D − 2 0 D − E F P − 10 F S
Cable size and flange size is different.
Cable size
Outer conductor size in mm, D means 50Ω
Flange size
Outer conductor size in mm, D means 50Ω
Standard of Flange
E:EIA I:IEC W:JEITA
Inner conductor
F:Female M:Male
Gas pass/stop
P:Gas pass S:Gas stop
Gas inlet exist or not
10:Inlet non 11:Inlet exist
Flange (swivel or not) / Non Flange F:Not swivel flange R:Swivel flange NF:Non Flange
Inner conductor assemble
S:Taper nut lock Z:Screw lock
Cable size
Outer conductor size in mm, D means 50Ω
Standard of interface
N:N type D:DIN-7/16
Inner conductor
J:Jack(Female) P:Plug(Male)
Gas inlet exist or not
11:Inlet exist 12:Inlet non
Inner conductor assemble
S:Taper nut lock Z:Screw lock
(3) N,DIN type interface connector
3 9 D − N J − 11 S
Note:In case of HF-39DB, please use “DB” instead of “D”
22
Accessories
CONNECTOR and TOOL
Tool Kit
Cable
Type
HF-20D
7/8"
FTK-20D
HF-39D
1-5/8"
FTK-39D
HF-50D
2-1/4"
FTK-50D
HF-70D
3"
FTK-70D
HF-77D
3-1/8"
FTK-77D
HF-100D
4"
FTK-100D
HF-105D
5"
FTK-105D
HF-120D
5-1/2"
FTK-120D
HF-152D
6-1/8"
FTK-152D
HF-203D-S 8"
FTK-203D
This tool kit is for attaching connectors at the end of the cable. The flaring tool included
will enhance V.S.W.R. performance because it is precisely engineered to elminate the
risk of connector burnout from hot spots.
Gas Inlet
Pipe
Copper
Decabon
Vinyl
Type
10
GI-C10
6
GI-C6
3/8"
GI-C3/8
1/4"
GI-C1/4
6
GI-DC6
6
GI-V6
8
GI-V8
9
GI-V9
Gas inlets are used to connect the gas pipe/hose to the connector (gas stop) to inflate
gas into the cable. A variety of sizes are available depending on the pipe/hose used.
23
Rigid Coaxial Line
DF, WX-
Rigid Coaxial Line (with Flange)
Standard
EIA
IEC
JEITA
Hitachi
Type
7/8"
WX-20DF
1-5/8"
WX-39DF
3-1/8"
WX-77DF
6-1/8"
WX-152DF
Standard
4-1/2"
WX-105DF
20D
WX-20DF(J)
39D
WX-39DF(J)
77D
WX-77DF(J)
120D
WX-120DF(J)
152D
WX-152DF(J)
203D
WX-203DF(J)
EIA
IEC
Outer conductor
WX-152DNF
4-1/2"
WX-105DNF
20D
WX-20DNF(J)
39D
WX-39DNF(J)
77D
WX-77DNF(J)
120D
WX-120DNF(J)
152D
WX-152DNF(J)
203D
WX-203DNF(J)
Dimension
4-1/2"
5"
6-1/8"
8"
14.94
31.27
42.8
50.1
64.0
86.2
Outer (mm)
8.66
16.87
33.40
44.73
52.1
66.0
88.2
Inner (mm)
19.94
38.79
76.89
103
120.0
151.9
203
Outer (mm)
22.23
41.30
79.38
106
123.2
155.6
208
2,000
2,000
2,000
5,000
4,000
5,000
4,000
1.6
7/8"
1-5/8"
3-1/8"
4-1/2"
1.4
5"
6-1/8"
8"
50
99.5
99.5
99.5
99.5
99.5
99.5
99.5
Inner (mΩ/m)
1.08
0.36
0.16
0.130
0.107
0.084
0.063
Outer (mΩ/m)
0.23
0.11
0.06
0.035
0.028
0.019
0.011
2,500
5,000
9,900
13,000 15,500 19,500 25,000
63
250
980
1,690
2,403
3,803
6,250
6,200
3,250
1,650
1,200
1,050
860
650
Peak voltage (V)
Peak power rating (kW)
Maximum frequency (MHz)
*The copper tube and the insulator
can be separately delivered.
Copper tube: WX- □□ DNF-T
Specification
Size
Velocity (%)
Insulation resistance (MΩ)
> 5,000
VHF
< 1.05
UHF
< 1.05
100 MHz (dB/100m)
1.24
0.64
0.33
0.25
0.215
0.17
200 MHz (dB/100m)
1.76
0.915
0.47
0.355
0.31
0.25
0.19
500 MHz (dB/100m)
2.79
1.46
0.76
0.58
0.5
0.41
0.315
800 MHz (dB/100m)
3.55
1.86
0.975
0.745
0.65
0.53
-
100 MHz (kW)
12.3
27.
79.4
121
190
250
402
200 MHz (kW)
8.7
19.6
55.7
85.2
133
176
278
500 MHz (kW)
5.5
12.3
34.8
53.2
83.9
109
168
800 MHz (kW)
4.3
9.7
27.4
41.9
66.5
86.3
-
Condition
1)Attenuation
•Ambient temperature 20 ºC, Nominal value
2)Average power
•Ambient temperature 50 ºC •Inner conductor temperature 150 ºC
24
WX-77DNF
6-1/8"
7.39
Impedance (Ω)
Average power 2)
WX-39DNF
3-1/8"
3-1/8"
Item
Attenuation 1)
1-5/8"
Hitachi
Electrical Characteristics
V.S.W.R.
WX-20DNF
1-5/8"
Standard length (mm)
Direct current
resistance
Type
7/8"
7/8"
Inner (mm)
Inner conductor
Size
JEITA
Size
Item
DNF-T
Rigid Coaxial Line (None Flange)
Size
Structure
DNF, WX-
•V.S.W.R.=1.0
0.13
1.2
Factor (K)
Type WX-
1.0
0.8
0.6
0.4
0.2
0
0
50
40
60
80
100
Temperature
Factor (K) of Ambient temperature and Average power
P=Po x K K=(150 -T) / 100
Po: Average power at Ambient temperature 50 ºC
P: Average power Ambient temperature T ºC
Rigid Coaxial Line
90 degree Elbow (Flange)
Standard
EIA
IEC
JEITA
Size
Type
7/8"
ELB-20D
1-5/8"
ELB-39D
3-1/8"
ELB-77D
6-1/8"
ELB-152D
4-1/2"
ELB-105D
20D
ELB-20D(J)
39D
ELB-39D(J)
77D
ELB-77D(J)
120D
ELB-120D(J)
152D
ELB-152D(J)
Type ELBAnchor connector
Standard
Size
Type
7/8"
ACX-20D
1-5/8"
ACX-39D
3-1/8"
ACX-77D
6-1/8"
ACX-152D
IEC
4-1/2"
ACX-105D
JEITA
120D
ACX-120D
EIA
Standard
Size
Type
7/8"
IEB-20D
1-5/8"
IEB-39D
3-1/8"
IEB-77D
6-1/8"
IEB-152D
IEC
4-1/2"
IEB-105D
JEITA
120D
IEB-120D
EIA
Straight coupling (Indoor use)
Standard
Size
Type
7/8"
SCX-20D
1-5/8"
SCX-39D
3-1/8"
SCX-77D
6-1/8"
SCX-152D
IEC
4-1/2"
SCX-105D
JEITA
120D
SCX-120D
EIA
Coupling adaptor (Flange to coupling)
Size
Type
Straight coupling (Indoor use)
Size
Type
7/8"
ICA-20D
7/8"
SCX-20D-S
1-5/8"
ICA-39D
1-5/8"
SCX-39D-S
3-1/8"
ICA-77D
3-1/8"
SCX-77D-S
6-1/8"
ICA-152D
6-1/8"
SCX-152D-S
IEC
4-1/2"
ICA-105D
IEC
4-1/2"
SCX-105D-S
JEITA
120D
ICA-120D
JEITA
120D
SCX-120D-S
Standard
EIA
Inner Support
Standard
Size
Type
7/8"
ISX-20D
1-5/8"
ISX-39D
3-1/8"
ISX-77D
6-1/8"
ISX-152D
IEC
4-1/2"
ISX-105D
JEITA
120D
ISX-120D
EIA
D
Type IEBD, SCXD,
ICAD, SCXD-S,
ISXD, ICXD
Rigid Coaxial Line (Indoor)
90 degree Elbow (Indoor use)
D, ACX-
Standard
EIA
Inner connector
Standard
Size
Type
7/8"
ICX-20D
1-5/8"
ICX-39D
3-1/8"
ICX-77D
6-1/8"
ICX-152D
IEC
4-1/2"
ICX-105D
JEITA
120D
ICX-120D
EIA
25
Dehydrator
Type MINILAB, LAB4.50, LAB9.50
This device pressurizes by dry air the coaxial cable to prevent moisture entering,
thus increasing the cable performance and lifetime.
Manufacturer:CIBRED SUD(Our Partner Company)
Item
Output pressure
Operating voltage
MINILAB
LAB4.50
LAB9.50
1 to 6 kPa (factory presettable)
10 to 60 kPa
10 to 60 kPa
AC 100 - 240 V
50/60 Hz
AC 220 - 240 V
50/60 Hz
AC 220 - 240 V
50/60 Hz
*1)
Maximum flow rate
150 Nℓ/h
300 Nℓ/h
1000 Nℓ/h
Better than -45 ℃
Better than -45 ℃
Better than -45 ℃
Normal operation
≦ 2.5 W
≦ 30 VA
≦ 30 VA
Regeneration phase
≦ 55 W
≦ 80 VA
≦ 160 VA
Dew point
Power
Consumption
Outlets
Dimension
Weight
6
6
4 or 8
Wall mounting
482x88x190 mm
482x131x305 mm
482x310x230 mm
Rack 19" mounting
482x88x190 mm
482x131x202 mm
482x310x150 mm
Frame N3 mounting
533x88x190 mm
532x131x202 mm
533x310x150 mm
Wall mounting
4.2 kg
8.5 kg
14 kg
Rack mounting
4.2 kg
8.5 kg
14 kg
*1) Others on request
Type DHK-2, DHK-3, DHK-15
Item
Nominal capacity (little/min.)
DHK-2
DHK-3
DHK-15
DHK-15S
2
3
15
15
Operating voltage
Consumption power
AC100V/AC200V
70(VA)
70(VA)
Dew point
Pressure
Outlets
Dimension (mm)
Weight (kg)
26
600(W)
600(W)
-40 ºC
Upper (Mpa)
0.035±0.003
Lower (Mpa)
0.01±0.003
3
0.035±0.003
0.01±0.003
3 to 6
1 to 6
1 to 8
530 x 360 x 120 600 x 450 x 150 950 x 450 x 400 920 x 650 x 210
20
25
80
70
INSTALLATION OF HF CABLES
Antenna
Pulley
Connector
Hoisting stocking
Protection cover
Recommended pulling length
per hoisting stocking
50m
Wire grip
Hoisting stocking
(during installation)
Band or rope
Tower
HF Cable
Hoisting wire
Cable drum
Winch
27
Caution when installing cables
Please pay attention to the following points in order to keep the electrical and mechanical characteristics of HF
cables in optimum working condition.
● Do not bend less than the minimum bending radius specified in this catalog.
Bending less than minimum bending radius can cause serious damage to the cable.
● Avoid putting undue pressure on the cable.
Do not drop tools or other objects on the cable.
● Do not leave a cut cable unattached.
After cutting cable, please attach the connector or waterproof it as soon as possible.
● Maximum pulling tension for the cable must be especially kept within the permissible limit.
To prevent damages during cable laying, hoisting and installation.
● Don’t drag the cable on sharp edged objects.
To avoid dameages of cable jacket. If dameged, will have influence upon the life of cable.
● When laying/hoidting cable, do not grip the connector portion.
To grip the cable portion with hoisting stocking.
To protect the connevtor with protection cover.
Attenuation value
The attenuation values on this catalog are Nominal values.
The Maximum values of attenuation are 105% of Nominal values.
When requesting information, Please provide us with the following.
1. Frequency band.
2. Cable length.
3. Connector type (EIA, JEITA, DIN, IEC, etc.)
4. If you need the tool kit to attach connectors.
- ACX is the code of Anchor Connector for coaxial transmission lines.
- WMS is the code of Wall entrygland Molded rubber (single run).
- HSC is the code of Hoisting Stocking (installation type).
- HSF is the code of Hoisting Stocking (Fix type).
- NFS is the code of Not Flange and Screw stop.
- ELB is the code of 90 degree ELBow with flange.
- IEB is the code of Indoor use 90 degree EIBow not flange.
- ICA is the code of Indoor use Coupling Adaptor with Flange.
- ISX is the code of Inner Support for rigid coaxial line.
- SCX is the code of Straight Coupling for rigid coaxial line.
- SCX-S is the code of Straight Coupling with Silver plating for rigid coaxial line.
- ICX is the code of Inner Connector for rigid coaxial line.
- Specifications subject to change without notice.
28
MEMO
MEMO
MEMO
Cable Materials Company
Hulic Asakusabashi Building,
22-16, Asakusabashi 1-chome, Taito-ku, Tokyo 111-0053, Japan
Tel: +81-3-6381-1397
Hitachi Metals Europe GmbH
Hitachi Metals Hong Kong Ltd.
HEAD OFFICE
Units 2212-14, 22/F., Miramar Tower, 132 Nathan Road,
Tsimshatsui, Kowloon, Hong Kong
Tel: +852-2724-4183
Immermannstrasse 14-16, 40210 Dusseldorf, Germany
Tel: +49-211-16009-0
LONDON OFFICE
Whitebrook Park, Lower Cookham Road, Maidenhead,
Berkshire, SL6 8YA United Kingdom
Tel: +44-1628-585960
MUNICH OFFICE
Radlkoferstraße 2, 81373 Munich, Germany
Tel: +49-89-7411-85114
MILANO OFFICE
Via Modigliani, 45 - 20090 Segrate (MI) - Italy
Tel: +39-02-7530188
Hitachi Cable America Inc.
2 Manhattanville Road, Suite 301, Purchase, NY 10577, U.S.A.
Tel: +1-914-694-9200
Hitachi Metals Singapore Pte. Ltd.
12 Gul Avenue, Singapore 629656
Tel: +65-6861-7711
HCAS Thai Trading Co., Ltd.
Hitachi Metals Taiwan, Ltd. Taipei Branch
11F, No. 9, Xiangyang Rd, Zhongzheng District Taipei City, Taiwan
Tel: +886-2-2311-2777
Hitachi Cable (China) Trading Co., Ltd.
H E A D O F F I C E & S A L E S D I VISION
11F, Chong Hing Finance Center, No. 288, NanJing Road (West),
Shanghai, 200003, China
Tel: +86-21-3366-3000
GUANGZHOU OFFICE
Room1001, Goldlion Digital Network Center, 138 Tiyu Road East,
Tianhe, Guangzhou 510620, China
Tel: +86-20-3878-0319
Hitachi Cable Trading (Dalian F.T.Z.) Co., Ltd.
Room 1102, Yoma IFC, No.128 Jinma Road, Dalian
Development Area, Dalian, 116600, China
Tel: +86-411-8733-2112
Unit 13A, 13th Floor, Ploenchit tower, 898 Ploenchit Road,
Limpini, Pathumwan, Bangkok 10330, Thailand.
Tel: +66-(0)2-260-6310
h t t p : / / w w w. h i t a c h i - m e t a l s. c o. j p
CAT.NO.KTE305D
The specifications of products in this catalog are subject to change without pr ior notice.
Printed in Japan ’
14-2