COMMERCIAL GRADE 8.0 x 2.5 x 3.8mm LOW

COMMERCIAL GRADE 8.0 x 2.5 x 3.8mm
LOW FREQUENCY SMD CRYSTAL
AKC25M
Pb in High Temperature Solder
(exempt per RoHS 2002/95/EC Annex (7))
RoHS
Compliant
8.0 x 2.5 x 3.8 mm
FEATURES:
APPLICATIONS:
• Low frequency 32.768kHz
• 2.5mm height ideal for high density circuit boards
• Suitable for RoHS reflow profile
• Extended temperature -40°C to +85°C
• Wide range in communication & measuring equipment
• Commercial applications
• Wireless communications
• PDA and Palm Pilots
STANDARD SPECIFICATIONS:
PARAMETERS
ABRACON P/N
Nominal Frequency
AKC25M Series
32.768 kHz
Operating Temperature
Turn-over Temperature
Storage Temperature
Frequency Tolerance
Capacitance Ratio
-40°C to + 85°C
+25°C to ±5°C
-55°C to +125°C
±20 ppm max.
450 typ.
Frequency Coefficient ( )
Equivalent Series Resistance
- 0.034±0.006 ppm/T²
50 kohms max.
Load Capacitance CL
12.5 pF (see option)
Shunt Capacitance C0
1.35 pF typ.
Drive Level
1.0 W max.
Aging @ 25°C ± 3°C first year
± 3 ppm max.
Insulation Resistance
500 M
with 100 Vdc ±15V
OPTIONS AND PART IDENTIFICATION:
(Left blank if standard)
AKC25M - 32.768kHz -
Load Capacitance
Blank: 12.5pF
9: 9pF
7: 7pF
ABRACON IS
ISO9001:2008
CERTIFIED
Freq. Tolerance
Blank: ± 20 ppm
1: ± 10 ppm
5: ± 15 ppm
3: ± 25 ppm
4: ± 30 ppm
-
-
Packaging
Blank: Bulk
T: Tape & Reel
Visit www.abracon.com for Terms & Conditions of Sale Revised: 07.19.10
30332 Esperanza, Rancho Santa Margarita, California 92688
tel 949-546-8000 | fax 949-546-8001 | www.abracon.com
COMMERCIAL GRADE 8.0 x 2.5 x 3.8mm
LOW FREQUENCY SMD CRYSTAL
AKC25M
Pb in High Temperature Solder
(exempt per RoHS 2002/95/EC Annex (7))
RoHS
Compliant
8.0 x 2.5 x 3.8 mm
OUTLINE DRAWING:
Dimensions: (inches) mm
REFLOW PROFILE
TAPE & REEL: T = Tape and reel 3,000pcs/reel
Dimensions: mm
ATTENTION: Abracon Corporation’s products are COTS – Commercial-Off-The-Shelf products; suitable for Commercial, Industrial and, where designated, Automotive Applications. Abracon’s products are not specifically designed for Military, Aviation, Aerospace, Life-dependant Medical applications or any application requiring high reliability where component failure could result in loss of life and/or property. For applications requiring high reliability and/or presenting an extreme
operating environment, written consent and authorization from Abracon Corporation is required. Please contact Abracon Corporation for more information.
ABRACON IS
ISO9001:2008
CERTIFIED
CERTIFIED
Visit www.abracon.com for Terms & Conditions of Sale Revised: 07.19.10
30332 Esperanza, Rancho Santa Margarita, California 92688
tel 949-546-8000 | fax 949-546-8001 | www.abracon.com