Intel®Server System H2000JF Family Technical Product Specification Intel order number: G39462-013 Revision 2.2 November, 2013 Enterprise Platforms and Services Division Intel® Server System H2000JF Family TPS Revision History Revision History Date Revision Number Modifications January, 2012 1.0 Initial release. February, 2012 1.1 Added environmental data. March, 2012 1.2 May, 2012 1.3 July, 2012 1.4 August, 2012 1.5 October, 2012 1.6 November, 2012 1.7 January, 2013 1.8 June, 2013 1.9 September, 2013 2.0 October, 2013 2.1 Updated environmental specifications. Updated environmental specifications with ASHRAE specification. Updated Processor TDP to conditional support 135W. Added new bridge board for 6G SAS support. Added riser support for non-transparent bridge. Updated safety notice to rail kit installation. Updated InfiniBand* usage recommendation. Corrected typo in USB device beep in POST. Added new 6G SAS module solution. Updated power redundant scheme. Updated link to Rail specification. Updated system specification. Updated description of double width add-in card. Updated warning message on PSU configuration. Updated E5-2600V2 support information. Updated Rail installation note. Updated power working mode. Updated POST LED decode table, Video POST decode table, and POST error beep code. Updated IOM carrier specification. November, 2013 2.2 Updated chassis air flow specification. ii Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS Disclaimers Disclaimers INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN INTEL'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER AND INTEL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. A "Mission Critical Application" is any application in which failure of the Intel Product could result, directly or indirectly, in personal injury or death. SHOULD YOU PURCHASE OR USE INTEL'S PRODUCTS FOR ANY SUCH MISSION CRITICAL APPLICATION, YOU SHALL INDEMNIFY AND HOLD INTEL AND ITS SUBSIDIARIES, SUBCONTRACTORS AND AFFILIATES, AND THE DIRECTORS, OFFICERS, AND EMPLOYEES OF EACH, HARMLESS AGAINST ALL CLAIMS COSTS, DAMAGES, AND EXPENSES AND REASONABLE ATTORNEYS' FEES ARISING OUT OF, DIRECTLY OR INDIRECTLY, ANY CLAIM OF PRODUCT LIABILITY, PERSONAL INJURY, OR DEATH ARISING IN ANY WAY OUT OF SUCH MISSION CRITICAL APPLICATION, WHETHER OR NOT INTEL OR ITS SUBCONTRACTOR WAS NEGLIGENT IN THE DESIGN, MANUFACTURE, OR WARNING OF THE INTEL PRODUCT OR ANY OF ITS PARTS. Intel may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or characteristics of any features or instructions marked "reserved" or "undefined". Intel reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. The information here is subject to change without notice. Do not finalize a design with this information. The products described in this document may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are available on request. Contact your local Intel sales office or your distributor to obtain the latest specifications and before placing your product order. Copies of documents which have an order number and are referenced in this document, or other Intel literature, may be obtained by calling 1-800-548-4725, or go to: http://www.intel.com/design/literature. Revision 2.2 Intel order number: G39462-013 iii Table of Contents Intel® Server System H2000JF Family TPS Table of Contents 1. Introduction .......................................................................................................................... 1 1.1 Chapter Outline ........................................................................................................ 1 1.2 Server Board Use Disclaimer .................................................................................. 2 2. Product Overview ................................................................................................................. 3 2.1 System Views .......................................................................................................... 5 2.2 System Dimensions ................................................................................................. 5 2.3 System Level Environmental Limits ......................................................................... 6 2.3.1 High Temperature Ambience (HTA) Support ........................................................... 7 2.3.2 Set Throttling Mode ............................................................................................... 11 2.3.3 Altitude ................................................................................................................... 11 2.3.4 Set Fan Profile ....................................................................................................... 11 2.3.5 Fan PWM Offset .................................................................................................... 11 2.3.6 Quiet Fan Idle Mode .............................................................................................. 11 2.3.7 Thermal Sensor Input for Fan Speed Control ........................................................ 12 2.4 System Parts ......................................................................................................... 13 2.5 Hard Drive and Peripheral Bays ............................................................................ 14 2.6 Server Board Overview .......................................................................................... 14 2.7 Front Bezel Support ............................................................................................... 17 2.8 Rack and Cabinet Mounting Options ..................................................................... 18 3. Power Subsystem .............................................................................................................. 19 3.1 Mechanical Overview ............................................................................................. 19 3.1.1 AC Power Supply Unit Dimension Overview ......................................................... 19 3.1.2 AC Power Supply Unit General Data ..................................................................... 20 3.1.3 AC Input Connector ............................................................................................... 20 3.1.4 AC Power Cord Specification Requirements ......................................................... 20 3.1.5 Power Supply Unit DC Output Connector .............................................................. 20 3.1.6 Handle Retention ................................................................................................... 21 3.1.7 LED Marking and Identification .............................................................................. 21 3.1.8 Power Cage with Power Distribution Board ........................................................... 22 3.1.9 Power Cage Output Pin Assignment ..................................................................... 22 3.2 AC Input Specification ........................................................................................... 24 3.2.1 Input Voltage and Frequency ................................................................................. 24 3.2.2 AC Input Power Factor .......................................................................................... 24 3.2.3 Efficiency ............................................................................................................... 24 3.2.4 AC Line Fuse ......................................................................................................... 25 3.2.5 AC Line Inrush ....................................................................................................... 25 3.2.6 AC Line Dropout/Holdup ........................................................................................ 25 3.2.7 AC Line Fast Transient (EFT) Specification .......................................................... 26 3.2.8 Hot Plug ................................................................................................................. 26 iv Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS 3.2.9 3.2.10 3.2.11 3.2.12 3.2.13 3.2.14 3.2.15 3.2.16 3.2.17 3.2.18 3.3 3.3.1 3.3.2 3.3.3 3.3.4 3.3.5 3.3.6 3.3.7 3.3.8 3.3.9 3.3.10 3.3.11 3.3.12 3.3.13 3.3.14 3.3.15 3.4 3.4.1 3.4.2 3.5 3.5.1 3.5.2 3.5.3 3.6 3.6.1 3.6.2 3.6.3 3.7 3.7.1 3.7.2 3.8 Revision 2.2 Table of Contents Susceptibility Requirements .................................................................................. 26 Electrostatic Discharge Susceptibility .................................................................... 26 Fast Transient/Burst .............................................................................................. 26 Radiated Immunity ................................................................................................. 26 Surge Immunity ...................................................................................................... 26 AC Line Transient Specification ............................................................................. 27 Power Recovery .................................................................................................... 27 Voltage Interruptions .............................................................................................. 27 AC Line Isolation .................................................................................................... 27 AC Power Inlet ....................................................................................................... 28 DC Ouput Specification ......................................................................................... 28 Output Power/Currents .......................................................................................... 28 Standby Output ...................................................................................................... 28 Voltage Regulation ................................................................................................ 29 Dynamic Loading ................................................................................................... 29 Capacitive Loading ................................................................................................ 29 Ripple/Noise .......................................................................................................... 29 Grounding .............................................................................................................. 30 Closed Loop Stability ............................................................................................. 30 Residual Voltage Immunity in Standby Mode ........................................................ 30 Common Mode Noise ............................................................................................ 30 Soft Starting ........................................................................................................... 30 Zero Load Stability Requirement ........................................................................... 31 Hot Swap Requirement .......................................................................................... 31 Forced Load Sharing ............................................................................................. 31 Timing Requirement .............................................................................................. 31 Power Supply Cold Redundancy Support ............................................................. 32 1200W CRPS Cold Redundancy ........................................................................... 33 1600W CRPS Cold Redundancy ........................................................................... 33 Control And Indicator Functions ............................................................................ 33 PSON# Input Signal ............................................................................................... 34 PWOK (Power Good) Output Signal ...................................................................... 34 SMBAlert# Signal ................................................................................................... 34 Protection Circuits .................................................................................................. 35 Current Limit (OCP) ............................................................................................... 35 Over Voltage Protection (OVP) .............................................................................. 35 Over Thermal Protection (OTP) ............................................................................. 36 PMBus* .................................................................................................................. 36 PSU Address Lines A0 .......................................................................................... 36 Accuracy ................................................................................................................ 37 Power Management Policy .................................................................................... 37 Intel order number: G39462-013 v Table of Contents Intel® Server System H2000JF Family TPS 4. Cooling Subsystem ............................................................................................................ 39 4.1 Processor Heatsink ................................................................................................ 39 4.2 Node Cooling Fans ................................................................................................ 40 4.3 Power Supply Fan ................................................................................................. 41 4.4 Air Duct Module ..................................................................................................... 41 4.5 Drive Bay Population Requirement ........................................................................ 42 5. System Boards in the Node Tray ...................................................................................... 43 5.1 Node Docking Board .............................................................................................. 43 5.1.1 Overview of Node Docking Board .......................................................................... 43 5.1.2 Pin-out Definition on Node Docking Board ............................................................ 44 5.2 Bridge Board .......................................................................................................... 45 5.2.1 Overview of Bridge Board ...................................................................................... 45 5.2.2 Pin-out Definition on Bridge Board ........................................................................ 47 5.3 6Gbs SAS Support Option 1 .................................................................................. 48 5.3.1 Overview of Bridge Board ...................................................................................... 48 5.3.2 Pin-out Definition on SAS 6Gbs Bridge Board ....................................................... 50 5.4 6Gbs SAS Support Option 2 .................................................................................. 51 5.4.1 Bridge Board .......................................................................................................... 51 5.4.2 Riser Card .............................................................................................................. 53 5.4.3 SAS Controller Module .......................................................................................... 55 6. Hard Disk Drive Support .................................................................................................... 57 6.1 Hard Disk Drive Bays Scheme .............................................................................. 57 6.2 Hard Drive Carrier .................................................................................................. 57 6.3 Hot-Swap Hard Drive Support ............................................................................... 58 6.3.1 Backplane Feature Set .......................................................................................... 59 6.3.2 Backplane Block Diagram ...................................................................................... 60 6.3.3 3.5" Hot Swap Backplane Connector Scheme ...................................................... 60 6.3.4 2.5" Hot Swap Backplane Connector Scheme ...................................................... 61 6.3.5 Backplane LED Support ........................................................................................ 63 6.3.6 Backplane Connector Definition ............................................................................ 63 7. Front Panel Control and Indicators .................................................................................. 67 7.1 Control Panel Button .............................................................................................. 68 7.2 Control Panel LED Indicators ................................................................................ 68 7.2.1 Power/Sleep LED .................................................................................................. 69 7.2.2 System Status LED ................................................................................................ 69 7.2.3 System Status LED – BMC Initialization ................................................................ 70 8. Configuration Jumpers ...................................................................................................... 71 8.1 Force Integrated BMC Update (J6B1) ................................................................... 72 8.2 Force ME Update (J1E2) ....................................................................................... 73 8.3 Password Clear (J1E3) .......................................................................................... 73 8.4 BIOS Recovery Mode (J1E1) ................................................................................ 74 vi Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS Table of Contents 8.5 Reset BIOS Settings (J1D5) .................................................................................. 75 9. PCI Express* Riser Card and Assembly .......................................................................... 77 9.1 PCI Express* Riser for Slot 1 ................................................................................. 77 9.1.1 Overview of PCI-Express* Riser ............................................................................ 77 9.1.2 Pin-out Definition on Slot 1 Riser ........................................................................... 77 9.2 PCI Express* Riser with IOM Carrier for Slot 2 (Optional) ..................................... 82 9.2.1 Overview of PCI-E* Riser with IOM Carrier ........................................................... 82 9.2.2 Pin-out Definition on Slot 2 Riser and IOM Carrier ................................................ 83 Appendix A: Integration and Usage Tips ................................................................................ 89 Appendix B: POST Code LED Decoder .................................................................................. 90 Appendix C: Video POST Code Errors ................................................................................... 95 Glossary................................................................................................................................... 102 Reference Documents ............................................................................................................ 105 Revision 2.2 Intel order number: G39462-013 vii List of Figures Intel® Server System H2000JF Family TPS List of Figures Figure 1. System Overview (Air Duct Removed) .......................................................................... 5 Figure 2. Compute Node Scheme (Rear View) ............................................................................ 5 Figure 3. Fan Control Model ....................................................................................................... 13 Figure 4. Major System Parts ..................................................................................................... 13 Figure 5. Intel® Server System H2312JF Drive Bay Overview .................................................... 14 Figure 6. Intel® Server System H2216JF Drive Bay Overview .................................................... 14 Figure 7. Intel® Server Board S2600JFQ/S2600JFF .................................................................. 15 Figure 8. Intel® Server Board S2600JF Components ................................................................. 16 Figure 9. Back Panel Feature Overview ..................................................................................... 16 Figure 10. Light-Guided Diagnostic LED Locations(Block A) ..................................................... 17 Figure 11. System Bezel Front View ........................................................................................... 17 Figure 12. AC Power Supply Unit Dimension Overview ............................................................. 19 Figure 13. Power Cage Overview ............................................................................................... 22 Figure 14. Power Distribution Board ........................................................................................... 23 Figure 15. AC Power Cord Specification .................................................................................... 28 Figure 16. Turn On/Off Timing (Power Supply Signals) .............................................................. 32 Figure 17. Power Supply Device Address .................................................................................. 36 Figure 18. PMBus* Monitoring Accuracy .................................................................................... 37 Figure 19. Processor Heatsink Overview .................................................................................... 39 Figure 20. Node Fan Set and Power/Control Connection ........................................................... 41 Figure 21. Compute Node Air Duct (Top View) .......................................................................... 42 Figure 22. Compute Node Tray Overview .................................................................................. 43 Figure 23. Node Docking Board .................................................................................................. 43 Figure 24. Bridge Board Overview .............................................................................................. 45 Figure 25. Connectors on Bridge Board ..................................................................................... 46 Figure 26. SAS 6Gbs Bridge Board Overview ............................................................................ 49 Figure 27. Connectors and Components on Spare Bridge Board .............................................. 50 Figure 28. Overview of the Bridge Board .................................................................................... 52 Figure 29. Connectors on Bridge Board ..................................................................................... 52 Figure 30. Overview of the Riser Card ........................................................................................ 53 Figure 31. SAS Controller Module Overview .............................................................................. 56 Figure 32. HDD Scheme for H2312JF ........................................................................................ 57 Figure 33. HDD Scheme for H2216JF ........................................................................................ 57 Figure 34. 3.5-inch HDD Assembly Overview ............................................................................. 58 Figure 35. 2.5-inch HDD Assembly Overview ............................................................................. 58 Figure 36. Passive Backplane Block Diagram (for One Node) ................................................... 60 Figure 37. 3.5" Backplane Component and Connectors (Front View) ........................................ 60 Figure 38. 3.5" Backplane Component and Connectors (Back View) ......................................... 61 Figure 39. 2.5" Backplane Component and Connectors (Front View) ........................................ 62 viii Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS List of Figures Figure 40. 2.5" Backplane Component and Connectors (Back View) ......................................... 62 Figure 41. Hard Drive Carrier LED .............................................................................................. 63 Figure 42. Front Control Panel .................................................................................................... 67 Figure 43. Jumper Locations and Functions ............................................................................... 71 Figure 44. PCI Express* Riser for Riser Slot 1 ........................................................................... 77 Figure 45. PCI Express* Riser with Bracket for Riser Slot 2 ....................................................... 82 Figure 46. IOM Carrier ................................................................................................................ 82 Figure 47. Diagnostic LED Location ........................................................................................... 90 Revision 2.2 Intel order number: G39462-013 ix List of Tables Intel® Server System H2000JF Family TPS List of Tables Table 1. System Feature Set ........................................................................................................ 3 Table 2. System SKU Matrix ......................................................................................................... 4 Table 3. Chassis Dimension (SKU: H2312JF) .............................................................................. 5 Table 4. Chassis Dimension (SKU: H2216JF) .............................................................................. 6 Table 5. System Environmental Limits Summary ......................................................................... 6 Table 6. Ambient Temperature versus System Configuration ...................................................... 9 Table 7. Specification Data for AC Power Supply Unit ............................................................... 20 Table 8. AC Power Cord Specification ........................................................................................ 20 Table 9. DC Output Power Connector ........................................................................................ 20 Table 10. Power Supply Status LED ........................................................................................... 21 Table 11. Pin Assignment of Power Ouput Connector ............................................................... 23 Table 12. Pin Assignment of Control Signal Connector .............................................................. 23 Table 13. AC Input Rating ........................................................................................................... 24 Table 14. Typical Power Factor .................................................................................................. 24 Table 15. Platinum Efficiency Requirement ................................................................................ 25 Table 16. AC Power Holdup Requirement .................................................................................. 25 Table 17. Performance Criteria ................................................................................................... 26 Table 18. AC Line Sag Transient Performance .......................................................................... 27 Table 19. AC Line Surge Transient Performance ....................................................................... 27 Table 20. Load Ratings for Single Power Supply Unit ................................................................ 28 Table 21. Voltage Regulation Limits ........................................................................................... 29 Table 22. Transient Load Requirements ..................................................................................... 29 Table 23. Capacitive Loading Conditions ................................................................................... 29 Table 24. Ripple and Noise ......................................................................................................... 30 Table 25. Timing Requirement .................................................................................................... 31 Table 26. 1200W CRPS Cold Redundancy Threshold ............................................................... 33 Table 27. 1600W CRPS Cold Redundancy Threshold ............................................................... 33 Table 28. PSON# Signal Characteristics .................................................................................... 34 Table 29. PWOK Signal Characteristics ..................................................................................... 34 Table 30. SMBAlert# Signal Characteristics ............................................................................... 35 Table 31. Over Current Protection .............................................................................................. 35 Table 32. Over Voltage Protection (OVP) Limits ........................................................................ 36 Table 33. PSU Addressing .......................................................................................................... 37 Table 34. PMBus* Accuracy ....................................................................................................... 37 Table 35. Power Management Policy ......................................................................................... 38 Table 36. 8-Pin Connector Pin-Out for Node Dual Rotor Fans ................................................... 41 Table 37. Main Power Input Connector ...................................................................................... 44 Table 38. Fan Control Signal Connector ..................................................................................... 44 Table 39. Node Fan Connector ................................................................................................... 44 x Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS List of Tables Table 40. Main Power Output Connector .................................................................................... 45 Table 41. Card Edge Connector Pin-out ..................................................................................... 47 Table 42. AHCI SATA0 DOM Connector Pin-out ........................................................................ 48 Table 43. USB 2.0 Type-A Connector Pin-out ............................................................................ 48 Table 44. 5V_AUX Power Connector Pin-out ............................................................................. 48 Table 45. Pin-out of Card Edge to Base Board ........................................................................... 50 Table 46. Pin-out of Card Edge to Hot Swap Back Plane ........................................................... 51 Table 47. Pin-out of Mini SAS Connector ................................................................................... 51 Table 48. Card Edge Pin-out of Bridge Board to SAS Controller ................................................ 53 Table 49. Card Edge Pin-out of Riser Card to SAS Controller ................................................... 53 Table 50. Card Edge Pin-out of Riser Card to PCIe Slot2 of Baseboard .................................... 54 Table 51. Hard Drive Carrier Status LED Functions ................................................................... 63 Table 52. Hard Drive Carrier Activity LED Functions .................................................................. 63 Table 53. Backplane Input Power Connector Pin-out ................................................................. 64 Table 54. 2-Blade Compute Node Power Connector Pin-out ..................................................... 64 Table 55. 2x40 Pin Connector Pin-out for Node Bridge Board ................................................... 64 Table 56. Front Panel Connector Pin-out ................................................................................... 65 Table 57. Power Supply Control Connector Pin-out ................................................................... 66 Table 58. Front Control Button Function ..................................................................................... 68 Table 59. Front LED Indicator Functions .................................................................................... 68 Table 60. Power LED Operation ................................................................................................. 69 Table 61. System Status LED Operation .................................................................................... 69 Table 62. Force Integrated BMC Update Jumper ....................................................................... 72 Table 63. Force Integrated BMC Update Jumper ....................................................................... 72 Table 64. Force ME Update Jumper ........................................................................................... 73 Table 65. BIOS Password Clear Jumper .................................................................................... 74 Table 66. BIOS Recovery Mode Jumper .................................................................................... 74 Table 67. Reset BIOS Jumper .................................................................................................... 75 Table 68. Riser Card Edge Pin-out ............................................................................................. 77 Table 69. PCI Express* Slot Pin-out on Riser Card .................................................................... 80 Table 70. Dedicated NIC Port LED Functionality ........................................................................ 83 Table 71. Riser Card Edge Pin-out ............................................................................................. 83 Table 72 PCI Express* Slot Pin-out on Riser Card ..................................................................... 85 Table 73. IO Module Slot on Carrier ........................................................................................... 87 Table 74. POST Code Diagnostic LED Location ........................................................................ 90 Table 75. POST Progress Code LED Example .......................................................................... 91 Table 76. Diagnostic LED POST Code Decoder ........................................................................ 91 Table 77. POST Error Message and Message ........................................................................... 95 Table 78. POST Error Beep Codes .......................................................................................... 100 Revision 2.2 Intel order number: G39462-013 xi List of Tables Intel® Server System H2000JF Family TPS <This page is intentionally left blank.> xii Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS 1. Introduction Introduction This Technical Product Specification (TPS) provides system specific information detailing the features, functionality, and high-level architecture of the Intel® Server System H2000JF family. You can also refer to the Intel® Server Board S2600JF Family Technical Product Specification to obtain greater detail of functionality and architecture of the server board integrated in this server system. In addition, you can obtain design-level information for specific subsystems by ordering the External Product Specifications (EPS) or External Design Specifications (EDS) for a given subsystem. EPS and EDS documents are not publicly available. They are only made available under NDA with Intel and must be ordered through your local Intel representative. For a complete list of available documents, refer to the Reference Documents section at the end of this document. The Intel® Server System H2000JF may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Refer to the Intel® Server Board S2600JF/Intel® Server System H2000JF Specification Update for published errata. 1.1 Chapter Outline This document is divided into the following chapters: Chapter 1 – Introduction Chapter 2 – Product Overview Chapter 3 – Power Subsystem Chapter 4 – Cooling Subsystem Chapter 5 – System Boards in the Node Tray Chapter 6 – Hard Disk Drive Support Chapter 7 – Front Panel Control and Indicators Chapter 8 – Configuration Jumpers Chapter 9 – PCI Express* Riser Card and Assembly Appendix A – Integration and Usage Tips Appendix B – POST Code LED Decoder Appendix C – Video POST Code Errors Glossary Reference Documents Revision 2.2 Intel order number: G39462-013 1 Intel® Server System H2000JF Family TPS Introduction 1.2 Server Board Use Disclaimer Intel Corporation server boards support add-in peripherals and contain a number of high-density VLSI and power delivery components that need adequate airflow to cool. Intel ensures through its own chassis development and testing that when Intel server building blocks are used together, the fully integrated system will meet the intended thermal requirements of these components. It is the responsibility of the system integrator who chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of air flow required for their specific application and environmental conditions. Intel Corporation cannot be held responsible if components fail or the server board does not operate correctly when used outside any of their published operating or non-operating limits. 2 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS 2. Product Overview Product Overview The Intel® Server System H2000JF family includes two major SKUs: H2312JF and H2216JF, which are rack mount 2U 4-node server systems, purpose-built for high-density and lowest total cost of ownership in dense computing applications, such as HPC and IPDC. The system is integrated with four units of Intel® Server Board S2600JF, and supports up to twelve 3.5" or sixteen 2.5" hot-swap SAS or SATA hard drives with Common Redundant Power Supply (CRPS) capability. This chapter provides a high-level overview of the system features. The following chapters provide greater detail for each major system component or feature. Table 1. System Feature Set Feature Processor Memory Chipset System Connectors/Headers System Fan Support Description ® ® Support Intel Xeon Processor E5-2600 and E5-2600V2 series processors: Up to eight GT/s Intel® QuickPath Interconnect (Intel® QPI) LGA 2011 Socket R Thermal Design Power (TDP) up to 135W with conditional ambient temperature Unbuffered DDR3 and registered DDR3 with ECC DIMMs Memory DDR3 data transfer rates of 800/1066/1333/1600/1867 MT/s Load Reduced DDR3 DIMM DDR3 standard I/O voltage of 1.5V (all speed) and DDR3 Low Voltage of 1.35V (1600MT/s or below) Intel® C600 Platform Controller Hub (PCH) with support for optional Storage Upgrade Key External I/O connectors: DB-15 Video connectors Two RJ-45 Network Interface for 10/100/1000 LAN One stacked two port USB 2.0 (Port 0/1) connectors One dedicated 1GbE management port on rIOM carrier (optional) One InfiniBand* QDR QSFP port (Board SKU: S2600JFQ) or One InfiniBand* FDR QSFP port (Board SKU: S2600JFF) Internal connectors/headers: Bridge Slot to extend board I/O with common bridge board SCU0 (Four SAS 3Gb/s ports) to backplane Front control panel signals One SATA (Port 0) 6Gb/s port for DOM Bridge Slot to extend board I/O with spare bridge board Mini SAS port (Four SAS 6Gb/s ports) from add-in RAID card to backplane Front control panel signals One Type-A USB 2.0 connector (USB port 2) One 2x7pin header for system FAN module One DH-10 serial Port A connector One SATA 6Gb/s (Port 1) One 2x4 pin header for Intel® RMM4 Lite One 1x4 pin header for Storage Upgrade Key Three sets of dual rotor fan for each node Add-in Adapter Support Three PCIe Gen III x16 riser slots: Riser slot 1 supports PCIe Gen III x16 Riser with LP PCIe add-in card. Riser slot 2 supports PCIe Gen III x8 Riser (Intel® rIOM). Riser slot 3 cannot be used with bridge board covered. One Bridge Slot for board I/O expansion On-board Video On-board Server Engines* LLC Pilot III Controller Revision 2.2 Intel order number: G39462-013 3 Intel® Server System H2000JF Family TPS Product Overview Feature Hard Disk Drive Description Integrated 2D Video Controller 128MB DDR2 Memory 12x 3.5-inch SATA/SAS HDD bays (SKU: H2312JF) Supported 16x 2.5-inch SATA/SAS HDD bays (SKU: H2216JF) RAID Support Intel® RSTe SW RAID 0/1/10/5 for SATA mode LSI* SW RAID 0/1/10/5 For each node: One Gigabit Ethernet device i350 connect to PCI-E x4 interfaces on the PCH, providing 2GbE ports for each node One QSFP port from Mellanox* ConnectX-3* to support QDR/FDR Infiniband* based on board SKU One dedicated 1GbE management port with RMM4 Lite installed 1200w AC Common Redundant Power Supply (CRPS), 80 plus Platinum with PFC, supporting CRPS configuration. Chassis SKU: H2312JFJR, H2216JFJR LAN System Power 1600w AC Common Redundant Power Supply (CRPS), 80 plus Platinum with PFC, supporting CRPS configuration. Chassis SKU: H2312JFKR, H2216JFKR Server Management On-board ServerEngines* LLC Pilot III* Controller Support for Intel® Remote Management Module 4 Lite solutions Intel® Light-Guided Diagnostics on field replaceable units Support for Intel® System Management Software Support for Intel® Intelligent Power Node Manager (Need PMBus*-compliant power supply) Table 2. System SKU Matrix Board SKU vs Chassis S2600JF 3.5” HDD with 1200W CRPS H2312JFJR 2.5” HDD with 1200W CRPS H2216JFJR 3.5” HDD with 1600W CRPS H2312JFKR 2.5” HDD with 1600W CRPS H2216JFKR S2600JFQ H2312JFQJR H2216JFQJR H2312JFQKR H2216JFQKR S2600JFF H2312JFFJR H2216JFFJR H2312JFFKR H2216JFFKR The Intel® Server System H2000JF family supports all Intel® Xeon® processor E5-2600 series with TDP 135W (8-core, 6-core) and below, or 80W (4-core) and below. You can find a full list of supported processors at the Intel® Support Website: http://www.intel.com/p/en_US/support/highlights/server/ss-h2000jf. 4 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS 2.1 Product Overview System Views Figure 1. System Overview (Air Duct Removed) Figure 2. Compute Node Scheme (Rear View) Caution: Installing two Power Supply Units with different wattage ratings on a system is not supported. This does not provide Power Supply Redundancy and causes the system to log multiple errors. 2.2 System Dimensions Table 3. Chassis Dimension (SKU: H2312JF) Height 87.9mm 3.46'' Width 438mm 17.24'' Depth Weight 771mm kg 30 38 30.35'' lbs 66.14 83.78 Chassis – basic configured (2 PSU, 0 drives) Chassis – fully configured (2 PSU, 12 drives) Revision 2.2 Intel order number: G39462-013 5 Intel® Server System H2000JF Family TPS Product Overview Table 4. Chassis Dimension (SKU: H2216JF) Height 87.9mm 3.46'' Width 438mm 17.24'' Depth Weight 733mm kg 29 32 28.86'' lbs 63.93 70.55 Chassis – basic configured (2 PSU, 0 drives) Chassis – fully configured (2 PSU, 16 drives) 2.3 System Level Environmental Limits The following table defines the system level operating and non-operating environmental limits. Table 5. System Environmental Limits Summary Parameter Limits Temperature Operating ASHRAE Class A2 – Continuous Operation. 10ºC to 35ºC (50ºF to 95ºF) with the maximum rate of change not to exceed 10ºC per hour ASHRAE Class A3 – Includes operation up to 40ºC for up to 900 hours per year. ASHRAE Class A4 – Includes operation up to 45ºC for up to 90 hours per year. Shipping -40ºC to 70ºC (-40ºF to 158ºF) Non-Operating 50% to 90%, non-condensing with a maximum wet bulb of 28°C (at temperatures from 25°C to 35°C) Operating Half sine, 2g, 11 mSec Unpackaged Trapezoidal, 25g, velocity change is based on packaged weight Packaged Product Weight: ≥ 40 to < 80 Non-palletized Free Fall Height = 18 inches Palletized (single product) Free Fall Height = NA Unpackaged 5 Hz to 500 Hz 2.20 g RMS random Packaged 5 Hz to 500 Hz 1.09 g RMS random Voltage 90V to 132V and 180V to 264 Frequency 47Hz to 63Hz Source Interrupt No loss of data for power line drop-out of 12 mSec Surge Nonoperating and operating Unidirectional Line to earth Only AC Leads I/O Leads DC Leads Air Discharged 8.0 kV Humidity Shock Vibration AC-DC 2.0 kV 1.0 kV 0.5 kV ESD 6 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS Parameter Product Overview Limits Contact Discharge 8.0 kV Operating -16 to 3048 m (-50 to 10,000 ft) Note: For altitudes above 2950 feet, the maximum operating temperature is derated 1°F/550 ft. Storage -16 to 10,600 m (-50 to 35,000 ft) Acoustics Sound Power Measured – – Air Flow Operation H2312xxKR: 8 to 41 CFM per node H2216xxKR: 8 to 61 CFM per node Power in Watts All range Servers/Rack Mount BA - 3.5'' HDD SKU: 6.9BA at idle and 7.4BA at active mode - 2.5'' HDD SKU: 6.5BA at idle and 7.07BA at active mode Altitude Note: Intel Corporation server boards contain a number of high-density VLSI and power delivery components that need adequate airflow to cool. Intel ensures through its own chassis development and testing that when Intel server building blocks are used together, the fully integrated system will meet the intended thermal requirements of these components. It is the responsibility of the system integrator who chooses not to use Intel developed server building blocks to consult vendor datasheets and operating parameters to determine the amount of airflow required for their specific application and environmental conditions. Intel Corporation cannot be held responsible, if components fail or the server board does not operate correctly when used outside any of its published operating or non-operating limits. Disclaimer Note: Intel ensures the unpackaged server board and system meet the shock requirement mentioned above through its own chassis development and system configuration. It is the responsibility of the system integrator to determine the proper shock level of the board and system if the system integrator chooses different system configuration or different chassis. Intel Corporation cannot be held responsible if components fail or the server board does not operate correctly when used outside any of its published operating or non-operating limits. In order to maintain comprehensive thermal protection, deliver the best system acoustics, and improve fan power efficiency, an intelligent Fan Speed Control (FSC) and thermal management technology (mechanism) is used. Options in <F2> BIOS Setup (BIOS > Advanced > System Acoustic and Performance Configuration) allow for parameter adjustments based on the actual system configuration and usage. Refer to the following sections for a description of each setting. 2.3.1 High Temperature Ambience (HTA) Support To keep the system operating within supported maximum thermal limits, the system must meet the following operating and configuration guidelines: The system operating ambient is designed for sustained operation up to 35ºC (ASHRAE Class A2) with short term excursion based operation up to 45ºC (ASHRAE Class A4). o The system can operate up to 40ºC (ASHRAE Class A3) for up to 900 hours per year. Revision 2.2 Intel order number: G39462-013 7 Product Overview Intel® Server System H2000JF Family TPS o The system can operate up to 45ºC (ASHRAE Class A4) for up to 90 hours per year. o System performance may be impacted when operating within the extended operating temperature range. o There is no long term system reliability impact when operating at the extended temperature range within the approved limits. Specific configuration requirements and limitations are documented in the configuration matrix found in the Intel® Server Board S2600JF Product Family Power Budget and Thermal Configuration Guidelines Tool, available as a download tool online at http://www.intel.com/p/en_US/support/. The CPU-1 processor + CPU heat sink must be installed first. The CPU-2 heat sink must be installed at all times, with or without a processor installed. Memory Slot population requirements: Note: Specified memory slots can be populated with a DIMM or supplied DIMM Blank. Memory population rules apply when installing DIMMs. DIMM Population Rules on CPU-1 – Install DIMMs in order; Channels A, B, C, and D. o DIMM Population on CPU-2 – Install DIMMs in order; Channels E, F, G, and H. o The following system configurations require that specific memory slots be populated at all times using either a DIMM or supplied DIMM Blank o System Configuration – 16x 2.5" hard drive bay or 12x 3.5" hard drive bay configuration + Intel® Server Board S2600JF (8-DIMM server board) All hard drive bays must be populated. Hard drive carriers can be populated with a hard drive or supplied drive blank. With the system operating, the air duct must be installed at all times. In single power supply configurations, the second power supply bay must have the supplied filler blank installed at all times. Thermally, the system can support the following PCI add-in cards: o Add-in cards with a minimum 100 LFM (0.5 m/s) air flow requirement can be installed in any available add-in card slot in both Riser Card #1 and Riser Card for IO Module carrier. o Add-in cards with a >200 LFM air flow requirement cannot be supported. o Note: Most PCI add-in cards have minimum air flow requirements of 100 LFM (0.5m/s). Some high power add-in cards have minimum air flow requirements of 200 LFM (1 m/s). System integrators must verify PCI add-in card air flow requirements from vendor specifications when integrating add-in cards into the system. 8 The system top-cover must be installed at all times when the system is in operation. Supported ambient temperature versus processor TDP is as follows. Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS Product Overview Table 6. Ambient Temperature versus System Configuration Notes: 1. 25°C is limited to elevations of 900m or less. 2. Quad Port IO Modules cannot be installed simultaneously with PCI Cards. 3. Processor – 130W-4C and 135W-8C may have some performance impact. 4. Processors – There may be some performance impact during fan failures. 5. For A3/A4 individual PS selection: a. b. For dual power supply configuration, power budget must fit within single power supply rated load and be installed in dual configuration, or Base System SKUs: H2216JF Base System SKUs: H2312JF For single power supply configuration, power budget must be sized with 30% margin to single power supply rated load. 6. LV refers to low voltage DIMMs (1.35V). 7. When identifying memory in the table, only Rank and Width are required. Capacity is not required. 8. Fan fail of dual-rotor fans refers to one rotor fail. "Fan Fail Support" indicates whether fan fail can be supported with specified configuration in each column. ASHRAE (See note 1) Cooling (See note 8) PS (See note 5) EP Processors (See notes 3 and 4) Revision 2.2 Classifications A2 A3 A4 25C A2 A3 A4 Max Ambient 35C 40C 45C 25C 35C 40C 45C Redundant Fan Configuration ● ● ● ● ● ● ● Fan Fail Support ● ● ● See Power Budget Tool Power Supplies Intel® Xeon® processor E52630L, 60w, 6C ● ● Intel® Xeon® processor E52650L, 70w, 8C ● ● See Power Budget Tool ● Intel order number: G39462-013 See note 1 See note 5 ● ● ● See note 4 ● ● ● See note 4 9 Intel® Server System H2000JF Family TPS Product Overview Memory Type (See note 6 and 7) Add-in Cards (See note 2) Module (See note 2) 10 Intel® Xeon® processor E52620, E5-2630, E5-2640, 95w, 6C ● ● ● ● ● ● ● See note 4 Intel® Xeon® processor E52650, E5-2660, 95w, 8C ● ● ● ● ● ● ● See note 4 Intel® Xeon® processor E52665, E5-2670, 115w, 8C ● ● ● ● ● ● Intel® Xeon® processor E52667, 130w, 6C ● ● ● ● ● See note 4 Intel® Xeon® processor E52680, 130w, 8C ● ● ● See note 4 Intel® Xeon® processor E52690, 135w, 8C ● ● Intel® Xeon® processor E52637, 80w, 2C ● ● ● ● ● ● ● See note 4 Intel® Xeon® processor E52603, E5-2609, 80w, 4C ● ● ● ● ● ● ● See note 4 Intel® Xeon® processor E52643, 130w, 4C ● Dual Rank x8 ● ● ● ● ● ● Dual Rank x4 ● ● ● ● ● Quad Rank x8 ● ● ● ● ● Quad Rank x4 ● ● ● Load Reduced DIMM ● ● ● PCI Cards ● ● ● ● ● ● ● AXX10GBTWLIOM – Dual 10GBASE-T IO Module ● ● ● ● ● ● ● AXX10GBNIAIOM – Dual SFP+ port 10GbE IO Module ● ● ● ● ● ● ● AXX1FDRIBIOM – Single Port FDR Infiniband* IO Module ● ● ● ● ● ● ● AXX2FDRIBIOM – Dual Port FDR Infiniband* IO Module ● ● ● ● ● ● ● AXX4P1GBPWLIOM – Quad Port 1GbE IO Module ● ● ● ● ● ● ● See note 4 ● ● Intel order number: G39462-013 See note 2 See note 2 Revision 2.2 Intel® Server System H2000JF Family TPS 2.3.2 Product Overview Set Throttling Mode This option is used to select the desired memory thermal throttling mechanism. Available settings include [Auto], [DCLTT], [SCLTT], and [SOLTT]. [Auto] – Factory Default Setting: BIOS automatically detects and identifies the appropriate thermal throttling mechanism based on DIMM type, airflow input, and DIMM sensor availability. [DCLTT] – Dynamic Closed Loop Thermal Throttling: For the SOD DIMM with system airflow input [SCLTT] – Static Close Loop Thermal Throttling: For the SOD DIMM without system airflow input [SOLTT] – Static Open Loop Thermal Throttling: For the DIMMs without sensor on DIMM (SOD) 2.3.3 Altitude This option is used to select the proper altitude that the system will be used in. Available settings include: [300m or less], [301m-900m], [901m-1500m], [Above 1500m]. Selecting an altitude range that is lower than the actual altitude the system will be operating at, can cause the fan control system to operate less efficiently, leading to higher system thermals and lower system performance. If the altitude range selected is higher than the actual altitude the system will be operating at, the fan control system may provide better cooling but with higher acoustics and higher fan power consumption. If the altitude is not known, selecting a higher altitude is recommended in order to provide sufficient cooling. 2.3.4 Set Fan Profile This option is used to set the desired Fan Profile. Available settings include [Performance] and [Acoustic]. The Acoustic mode offers the best acoustic experience and appropriate cooling capability covering the mainstream and the majority of the add-in cards used. Performance mode is designed to provide sufficient cooling capability covering all kinds of add-in cards on the market. 2.3.5 Fan PWM Offset This option is reserved for manual adjustment to the minimum fan speed curves. The valid range is from [0 to 100] which stands for 0% to 100% PWM adding to the minimum fan speed. This feature is valid when Quiet Fan Idle Mode is at Enabled state. The default setting is [0]. 2.3.6 Quiet Fan Idle Mode This feature can be [Enabled] or [Disabled]. If enabled, the fans will either shift to lower speeds or stop when the aggregate sensor temperatures are satisfied, indicating the system is at ideal thermal/light loading conditions. When the aggregate sensor temperatures are not satisfied, the fans will shift back to normal control curves. If disabled, the fans will never shift to lower fan speeds or stop, regardless of whether the aggregate sensor temperatures are satisfied. The default setting is [Disabled]. Note: The feature above may or may not be in effect and depends on the actual thermal characteristics of the specified system. Revision 2.2 Intel order number: G39462-013 11 Intel® Server System H2000JF Family TPS Product Overview 2.3.7 Thermal Sensor Input for Fan Speed Control The BMC uses various IPMI sensors as inputs to fan speed control. Some of the sensors are actual physical sensors and some are “virtual” sensors derived from calculations. The following IPMI thermal sensors are used as input to fan speed control: Front Panel Temperature Sensor 1 Server board Temperature Sensor 2 Processor Margin Sensors 3, 5, 6 DIMM Thermal Margin Sensors 3, 5 Exit Air Temperature Sensor 1, 4, 8 Chipset Temperature Sensor 4,6 On-board Ethernet Controller Temperature Sensors 4, 6 Add-In Intel SAS/IO Module Temperature Sensors 4, 6 Power Supply Thermal Sensor 4, 9 Processor VR Temperature Sensors 4, 7 DIMM VR Temperature Sensors 4, 7 BMC Temperature Sensor 4, 7 Global Aggregate Thermal Margin Sensors 8 Notes: 1. For fan speed control in Intel chassis 2. For fan speed control in 3rd party chassis 3. Temperature margin from throttling threshold 4. Absolute temperature 5. PECI value or margin value 6. On-die sensor 7. On-board sensor 8. Virtual sensor 9. Available only when PSU has PMBus* 12 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS Product Overview The following diagram illustrates the fan speed control structure. Figure 3. Fan Control Model 2.4 A B C D System Parts E F G H Compute Node 3 Tray Compute Node 1 Tray Compute Node 4 Tray Compute Node 2 Tray Common Redundant Power Supply HDD bays with Hot Swap Backplane Upper and Lower Power Distribution Boards Front Control Panel Note: Not shown – Rack slide rail and top cover. Figure 4. Major System Parts Revision 2.2 Intel order number: G39462-013 13 Intel® Server System H2000JF Family TPS Product Overview 2.5 Hard Drive and Peripheral Bays Intel®Server System H2312JF Not Supported Intel®Server System H2216JF Not Supported Not Supported Not Supported SATA/SAS Hard Disk Drives (3.5-inch) Up to 12 Not Supported SATA/SAS Hard Disk Drives (2.5-inch) Not Supported Up to 16 Support Support Slim-line SATA Optical Drive Internal USB Floppy Drive SATA DOM Figure 5. Intel® Server System H2312JF Drive Bay Overview Figure 6. Intel® Server System H2216JF Drive Bay Overview 2.6 Server Board Overview The chassis is mechanically and functionally designed to support half-width server board, including Intel® Server Board S2600JF. The following sections provide an overview of the server board feature sets. 14 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS Product Overview Figure 7. Intel® Server Board S2600JFQ/S2600JFF The following figure shows the layout of the server board. Each connector or major component is identified by a number or letter, and a description is given in the following figure. A 2x7 fan control connector I Slot2 (PCIe Gen3x16) Q VGA out Y SATA port 1 B VRS (4 total) J Infiniband* QDR/FDR R Dual port 1Gbe NIC Z PCH C600 C Slot3 (PCIe Gen3x16) K RMM4 lite S NIC Port 2 AA CPU 1 D CPU2 DIMM (4 total) L POST and InfiniBand* Status LED T Serial Port A AB XDP connector E CPU1 DIMM (4 total) M QSFP U NIC Port 1 AC CPU 2 Revision 2.2 Intel order number: G39462-013 15 Intel® Server System H2000JF Family TPS Product Overview F Bridge board connector N USB x2 V Slot1 (PCIe Gen3x16) G IPMB O Debug connector W Integrated BMC H 2x5 USB P Status and ID LED X Storage Upgrade key AD 2x3 PWR connector (2 total) Figure 8. Intel® Server Board S2600JF Components A Description NIC port 1 (RJ45)1 E Description Status LED B NIC port 2 (RJ45)1 F Dual port USB connector C DB15 video out G QSFP Connector2 D ID LED H QSFP status and Diagnostic LED Figure 9. Back Panel Feature Overview Note 1: The Intel® Server System H2312JF and H2216JF require the use of shielded LAN cable to comply with Emission/Immunity regulatory requirements. Use of non shield cables may result in product non-compliance. Note 2: The Intel® Server System H2312JFF and H2216JFF are recommended to use two meters or three meters length cables for better EMI performance. 16 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS A Diagnostic LED Group Product Overview B QSFP Link/Activity LED Figure 10. Light-Guided Diagnostic LED Locations(Block A) 2.7 Front Bezel Support ® Intel Server System H2000JF family provides front panel bezel. The bezel provides protection to system HDD bays with a lock to chassis. The front view of the bezel is as below. Figure 11. System Bezel Front View Revision 2.2 Intel order number: G39462-013 17 Intel® Server System H2000JF Family TPS Product Overview 2.8 Rack and Cabinet Mounting Options The chassis is designed to support 19 inches wide by up to 30 inches deep server cabinets. The system bundles with the following Intel rack mount option: A basic slide rail kit (Product order code – AXXELVRAIL) is designed to mount the chassis into a standard (19 inches by up to 30 inches deep) EIA-310D compatible server cabinet. Caution: THE MAXIMUM RECOMMENDED SERVER WEIGHT FOR THE RACK RAILS CAN BE FOUND at http://www.intel.com/support/motherboards/server/sb/CS-033655.htm. EXCEEDING THE MAXIMUM RECOMMENDED WEIGHT OR MISALIGNMENT OF THE SERVER MAY RESULT IN FAILURE OF THE RACK RAILS HOLDING THE SERVER. Use of a mechanical assist to install and align server into the rack rails is recommended. Advisory Note: The AXXELVRAIL value rack mount rail kit is not designed to support shipment of the server system while installed in a rack. Advisory Note: The AXXELVRAIL only supports specific rack type with 3/8” square and 7.1mm round holes. 18 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS 3. Power Subsystem Power Subsystem The system supports AC 1+1 hot swap power supply module and two power distribution board which can support 2U rack high density server system. Two different power supply units are supported: 1200W and 1600W. The single power supply module has Platinum level energy efficiency, demonstrating climate saver with silver rating. 3.1 Mechanical Overview The power supply module has a simple retention mechanism to retain the module self after it is inserted. This mechanism withstands the specified mechanical shock and vibration requirements. The power distribution board is fixed in the chassis with screws. This specification defines a 1+1 hot swap redundancy power supply that supports 2U server system. Using existing power supply module provided by vendor with updated PMBus* and custom-made power connector board supports four nodes of Intel® Server Board S2600JF. The power supply has two outputs: 12V and 12VSB. The input is auto ranging and power factor corrected. The PMBus* features included in this specification are requirements for AC silver rated box power supply for use in server systems based on Intel® Server System H2000JF Family. This specification is based on the PMBus* Specifications part I and II, revision 1.1. 3.1.1 AC Power Supply Unit Dimension Overview The casing dimension is 73.5mm x 265.0mm x 39/40mm (W x L x H). The power supply contains a single 40mm fan. The power supply has a card edge output that interfaces with a 2x25 card edge connector in the system. The AC plugs directly into the external face of the power supply. Figure 12. AC Power Supply Unit Dimension Overview Revision 2.2 Intel order number: G39462-013 19 Intel® Server System H2000JF Family TPS Power Subsystem 3.1.2 AC Power Supply Unit General Data Following is general specification data for AC Power Supply Unit. Table 7. Specification Data for AC Power Supply Unit Wattage Voltage Heat Dissipation Maximum Inrush Current 1200W/1600W (Energy Smart) 90 – 264 VAC, auto-ranging, 47 Hz-63 Hz 2560 BTU/hr Under typical line conditions and over the entire system ambient operating range, the inrush current may reach 65 A per power supply for 5 ms Platinum Platinum 80 Plus rating Climate Saver (CS) rating 3.1.3 AC Input Connector The power supply has an internal IEC320 C14 power inlet. The inlet is rated for a minimum of 10A at 250VAC. 3.1.4 AC Power Cord Specification Requirements The AC power cord used meets the following specification requirements. Table 8. AC Power Cord Specification Cable Type Wire Size Temperature Rating Amperage Rating Cable Type 3.1.5 SJT 16 AWG 105ºC 13A SJT Power Supply Unit DC Output Connector The DC output connector pin-out is defined as follows. Table 9. DC Output Power Connector A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 A18 20 GND GND GND GND GND GND GND GND GND +12V +12V +12V +12V +12V +12V +12V +12V +12V PSU Output Connector B1 B2 B3 B4 B5 B6 B7 B8 B9 B10 B11 B12 B13 B14 B15 B16 B17 B18 Intel order number: G39462-013 GND GND GND GND GND GND GND GND GND +12V +12V +12V +12V +12V +12V +12V +12V +12V Revision 2.2 Intel® Server System H2000JF Family TPS Power Subsystem PSU Output Connector A19 PMBus* SDA* B19 A0* (SMBus* address) A20 PMBus* SCL* B20 A1* (SMBus* address) A21 PSON B21 12V STBY A22 SMBAlert# B22 Cold Redundancy Bus* A23 Return Sense B23 12V load share bus A24 +12V Remote Sense B24 No Connect A25 PWOK B25 CRPS Compatibility Check pin* * Refer to CRPS Common Requirements Specification. 3.1.6 Handle Retention The power supply has a handle to assist extraction. The module can be inserted and extracted without the assistance of tools. The power supply also has a latch which retains the power supply into the system and prevents the power supply from being inserted or extracted from the system when the AC power cord is pulled into the power supply. The handle protects the operator from any burn hazard through the use of industrial designed plastic handle or equivalent material. 3.1.7 LED Marking and Identification The power supply uses a bi-color LED, Amber and Green, for status indication. The following table shows the LED states for each power supply operating state. Table 10. Power Supply Status LED Power Supply Condition Output ON and OK No AC power to all power supplies AC present / Only 12VSB on (PS off) or PS in Cold redundant state AC cord unplugged or AC power lost, with a second power supply in parallel still with AC input power Power supply warning events where the power supply continues to operate; high temp, high power, high current, slow fan Power supply critical event causing a shutdown; failure, OCP, OVP, Fan Fail Power supply FW updating Revision 2.2 Intel order number: G39462-013 LED State Solid GREEN OFF 1Hz Blink GREEN Solid AMBER 1Hz Blink Amber Solid AMBER 2Hz Blink GREEN 21 Intel® Server System H2000JF Family TPS Power Subsystem 3.1.8 Power Cage with Power Distribution Board The power cage is at the middle of the chassis, consisting of two Power Distribution Boards (PDBs) to support Common Redundant Power Supplies (CRPS). Caution: Installing two Power Supply Units with different wattage ratings on a system is not supported. This does not provide Power Supply Redundancy and causes the system to log multiple errors. Following is the power system overview. A B C Power Distribution Board 1 Power Distribution Board 2 Power Supply Unit #2 (upper) and #1 (lower) Figure 13. Power Cage Overview 3.1.9 Power Cage Output Pin Assignment The power cage provides +12V and +12VSTB output to the system. Each PDB has two 2x9 power output cables to system backplane, together with one 2x8 signal control cable for power management. Refer to the following table for PDB pin assignment. 22 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS A B C D Power Subsystem Main Power Output Connector P1 Power Supply Unit Connector Control Signal Connector Main Power Output Connector P2 Figure 14. Power Distribution Board Table 11. Pin Assignment of Power Ouput Connector Pin Description Pin Description 1 GND 2 +12V 3 GND 4 +12V 5 GND 6 +12V 7 GND 8 +12V 9 GND 10 +12V 11 GND 12 +12V 13 GND 14 +12V 15 GND 16 +12V 17 GND 18 +12V Table 12. Pin Assignment of Control Signal Connector Pin Revision 2.2 Description Pin Description 1 PMBus* SDA 2 A0 (SMBus* Address) 3 PMBus* SCL 4 A1 (SMBus* Address) 5 PSON# 6 12V Load Share Bus 7 SMBAlert# 8 Cold Redundancy Bus Intel order number: G39462-013 23 Intel® Server System H2000JF Family TPS Power Subsystem Pin 3.2 3.2.1 Description Pin Description 9 Return Sense 10 PWOK 11 +12V Remote Sense 12 Compatibility Bus 13 Reserved 14 +12VSB 15 +12VSB 16 Key Pin (removed) AC Input Specification Input Voltage and Frequency The power supply operates within all specified limits over the following input voltage range. Harmonic distortion of up to 10% THD does not cause the power supply to go out of specific limits. The power supply is capable of start-up (power-on) with full rated power load, at line voltage as low as 90VAC. Table 13. AC Input Rating Parameter Min Rated Max Start up VAC Power Off VAC 110VAC 220VAC Frequency 90 Vrms 180 Vrms 47 Hz 100-127 Vrms 200-240 Vrms 50/60 Hz 140 Vrms 264 Vrms 63 Hz 85 VAC± 4VAC 70VAC±5VAC Note: 1. Maximum input current at low input voltage range is measured at 90VAC, at max load. 2. Maximum input current at high input voltage range is measured at 180VAC, at max load. 3. This requirement is not to be used for determining agency input current markings. 3.2.2 AC Input Power Factor The power supply meets the power factor requirements stated in the Energy Star Program Requirements for Computer Servers. These requirements are stated below. Table 14. Typical Power Factor Output Power Power Factor 10% load > 0.80 20% load > 0.90 50% load > 0.90 100% load > 0.95 Note: Tested at 230VAC, 50Hz and 60Hz and 115VAC, 60Hz. Tested according to Generalized Internal Power Supply Efficiency Testing Protocol, Rev 6.4.3. This is posted at http://efficientpowersupplies.epri.com/methods.asp. 3.2.3 Efficiency The following table provides the required minimum efficiency level at various loading conditions. These are provided at different load levels; 100%, 50%, 20%, and 10%. Output is loaded according to the proportional loading method defined by 80 Plus in Generalized Internal Power Supply Efficiency Testing Protocol, Rev 6.4.3. This is posted at: http://efficientpowersupplies.epri.com/methods.asp. 24 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS Power Subsystem Table 15. Platinum Efficiency Requirement Loading 100% of maximum 50% of maximum 20% of maximum 10% of maximum 91% 94% 90% 82% Minimum Efficiency The power supply passes with enough margin to make sure in production that all power supplies meet these efficiency requirements. 3.2.4 AC Line Fuse The power supply has one line fused in the single line fuse on the line (Hot) wire of the AC input. The line fusing is acceptable for all safety agency requirements. The input fuse is a slow blow type. AC inrush current does not cause the AC line fuse to blow under any conditions. All protection circuits in the power supply do not cause the AC fuse to blow unless a component in the power supply has failed. This includes DC output load short conditions. 3.2.5 AC Line Inrush The AC line inrush current does not exceed 65A peak for up to one-quarter of the AC cycle, after which the input current is no more than the specified maximum input current. The peak inrush current is less than the ratings of its critical components (including input fuse, bulk rectifiers, and surge limiting device). The power supply meets the inrush requirements for any rated AC voltage, during turn on at any phase of AC voltage, during a single cycle AC dropout condition as well as upon recovery after AC dropout of any duration, and over the specified temperature range (Top). 3.2.6 AC Line Dropout/Holdup An AC line dropout is defined to be when the AC input drops to 0VAC at any phase of the AC line for any length of time. During an AC dropout the power supply meets dynamic voltage regulation requirements. An AC line dropout of any duration does not cause tripping of control signals or protection circuits. If the AC dropout lasts longer than the holdup time, the power supply will recover and meet all turn on requirements. The power supply meets the AC dropout requirement over rated AC voltages and frequencies. A dropout of the AC line for any duration does not cause damage to the power supply. Table 16. AC Power Holdup Requirement Loading 70% Holdup Time 10.6 msec The 12VSTB output voltage stays in regulation under its full load (static or dynamic) during an AC dropout of 70ms min (=12VSB holdup time) whether the power supply is in ON or OFF state (PSON asserted or de-asserted). Revision 2.2 Intel order number: G39462-013 25 Intel® Server System H2000JF Family TPS Power Subsystem 3.2.7 AC Line Fast Transient (EFT) Specification The power supply meets the EN61000-4-5 directive and any additional requirements in IEC1000-4-5: 1995 and the Level 3 requirements for surge-withstand capability, with the following conditions and exceptions: These input transients do not cause any out-of-regulation conditions, such as overshoot and undershoot, nor cause any nuisance trips of any of the power supply protection circuits. The surge-withstand test does not produce damage to the power supply. The supply meets surge-withstand test conditions under maximum and minimum DC-output load conditions. 3.2.8 Hot Plug The power supply is designed to allow connection into and removal from the system without removing power to the system. During any phase of insertion, start-up, shutdown, or removal, the power supply does not cause any other modules in the system to deviate outside of their specifications. When AC power is applied, the auxiliary supply will turn on providing bias power internal to the supply and the 5VSB standby output. 3.2.9 Susceptibility Requirements The power supply meets the following electrical immunity requirements when connected to a cage with an external EMI filter, which meets the criteria defined in the SSI document EPS Power Supply Specification. For further information on customer standards, request a copy of the customer Environmental Standards Handbook. Table 17. Performance Criteria Level A B C 3.2.10 Description The apparatus continues to operate as intended. No degradation of performance. The apparatus continues to operate as intended. No degradation of performance beyond spec limits. Temporary loss of function is allowed provided the function is self-recoverable or can be restored by the operation of the controls. Electrostatic Discharge Susceptibility The power supply complies with the limits defined in EN 55024: 1998 using the IEC 61000-42:1995 test standard and performance criteria B defined in Annex B of CISPR 24. 3.2.11 Fast Transient/Burst The power supply complies with the limits defined in EN55024: 1998 using the IEC 61000-44:1995 test standard and performance criteria B defined in Annex B of CISPR 24. 3.2.12 Radiated Immunity The power supply complies with the limits defined in EN55024: 1998 using the IEC 61000-43:1995 test standard and performance criteria A defined in Annex B of CISPR 24. 3.2.13 Surge Immunity The power supply is tested with the system for immunity to AC Ring wave and AC Unidirectional wave, both up to 2kV, per EN 55024:1998, EN 61000-4-5:1995 and ANSI C62.45: 1992. 26 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS Power Subsystem The pass criteria include: No unsafe operation is allowed under any condition; all power supply output voltage levels stay within proper spec levels; No change in operating state or loss of data during and after the test profile; No component damage under any condition. The power supply complies with the limits defined in EN55024: 1998 using the IEC 61000-45:1995 test standard and performance criteria B defined in Annex B of CISPR 24. 3.2.14 AC Line Transient Specification AC line transient conditions are defined as sag and surge conditions. Sag conditions are also commonly referred to as “brownout”; these conditions are defined as the conditions when the AC line voltage drops below nominal voltage. Surge conditions are defined as the conditions when the AC line voltage rises above nominal voltage. The power supply meets the requirements under the following AC line sag and surge conditions. Table 18. AC Line Sag Transient Performance AC Line Sag (10 sec interval between each sagging) Duration Sag 0 to ½ AC cycle 95% > 1 AC cycle >30% Operating AC Voltage Nominal AC Voltage ranges Nominal AC Voltage ranges Line Frequency Performance Criteria. 50/60Hz No loss of function or performance 50/60Hz Loss of function acceptable, selfrecoverable Table 19. AC Line Surge Transient Performance AC Line Surge Duration Surge Operating AC Voltage Line Frequency Continuous 10% Nominal AC Voltages 50/60Hz 0 to ½ AC cycle 30% Mid-point of nominal AC Voltages 50/60Hz 3.2.15 Performance Criteria No loss of function or performance No loss of function or performance Power Recovery The power supply recovers automatically after an AC power failure. AC power failure is defined to be any loss of AC power that exceeds the dropout criteria. 3.2.16 Voltage Interruptions The power supply complies with the limits defined in EN55024: 1998/A1: 2001/A2: 2003 using the IEC 61000-4-11: Second Edition: 2004-03 test standard and performance criteria C defined in Annex B of CISPR 24. 3.2.17 AC Line Isolation The power supply meets all safety agency requirements for dielectric strength. Transformers’ isolation between primary and secondary windings complies with the 3000VAC (4242VDC) dielectric strength criteria. If the working voltage between primary and secondary dictates a higher dielectric strength test voltage, the highest test voltage will be used. In addition the insulation system complies with reinforced insulation per safety standard IEC 950. Separation Revision 2.2 Intel order number: G39462-013 27 Intel® Server System H2000JF Family TPS Power Subsystem between the primary and secondary circuits, and primary to ground circuits, complies with the IEC 950 spacing requirements. 3.2.18 AC Power Inlet The AC input connector is an IEC 320 C-14 power inlet. This inlet is rated for 10A/250 VAC. The AC power cord meets the following specification requirements. Cable Type Wire Size SJT 16 AWG Temperature Rating 105ºC Amperage Rating 13 A Voltage 125V Figure 15. AC Power Cord Specification 3.3 3.3.1 DC Ouput Specification Output Power/Currents The following table defines the minimum power and current ratings. The power supply meets both static and dynamic voltage regulation requirements for all conditions. Table 20. Load Ratings for Single Power Supply Unit Note: 1. 2. 3. 3.3.2 Parameter PSU SKU Min Max 1200W 1600W Peak 2,3 1200W 1600W Unit +12V main (200-240VAC) 0.0 100 133 133 175 A +12V main (100-127VAC) 0.0 83 83 110 110 A +12VSTB 0.0 3.0 3.5 3.5 2.4 A 12VSTB provides 4.0A with two power supplies in parallel. The power supply fan is allowed to run in standby mode for loads > 1.5A. Peak combined power for all outputs does not exceed 1600W (for 1200W PSU) and 2100W (for 1600W PSU). Length of time peak power can be supported based on thermal sensor and assertion of the SMBAlert# signal. Minimum peak power duration is 20 seconds without asserting the SMBAlert# signal. Standby Output The 12VSB output is present when an AC input greater than the power supply turn on voltage is applied. 28 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS 3.3.3 Power Subsystem Voltage Regulation The power supply output voltages stay within the following voltage limits when operating at steady state and dynamic loading conditions. These limits include the peak-peak ripple/noise. These are measured at the output connectors. Table 21. Voltage Regulation Limits Parameter Min Nom Max Unit Tolerance +12VSTB +11.40V +12.000V +12.60V Vrms ±5% +12V +11.40V +12.000V +12.60V Vrms ±5% The combined output continuous power of all outputs does not exceed 3200W (1600W from each power supply unit). Each output has a maximum and minimum current rating shown in the table below. The power supply meets both static and dynamic voltage regulation requirements for the minimum dynamic loading conditions. The power supply meets only the static load voltage regulation requirements for the minimum static load conditions. 3.3.4 Dynamic Loading The output voltages remain within limits specified for the step loading and capacitive loading specified in the table below. The load transient repetition rate is tested between 50Hz and 5kHz at duty cycles ranging from 10% to 90%. The load transient repetition rate is only a test specification. The step load may occur anywhere within the MIN load to the MAX load conditions. Table 22. Transient Load Requirements Output +12VSTB +12V Step Load Size 1.0A 60% of max load Load Slew Rate 0.25 A/sec 0.25 A/sec Test Capacitive Load 20 F 2000 F Note: For dynamic condition +12V min loading is 1A. 3.3.5 Capacitive Loading The power supply is stable and meets all requirements with the following capacitive loading conditions. Table 23. Capacitive Loading Conditions 3.3.6 Output +12V Min 500 Max 25,000 Units F +12VSTB 20 3100 F Ripple/Noise The maximum allowed ripple/noise output of the power supply is defined in the table below. This is measured over a bandwidth of 10Hz to 20MHz at the power supply output connectors. A 10F tantalum capacitor in parallel with a 0.1F ceramic capacitor is placed at the point of measurement. Revision 2.2 Intel order number: G39462-013 29 Intel® Server System H2000JF Family TPS Power Subsystem Table 24. Ripple and Noise +12V 120mVp-p 3.3.7 +12VSTB 120mVp-p Grounding The output ground of the pins of the power supply provides the output power return path. The output connector ground pins are connected to the safety ground (power supply enclosure). This grounding is well designed to ensure passing the max allowed Common Mode Noise levels. The power supply is provided with a reliable protective earth ground. All secondary circuits are connected to protective earth ground. Resistance of the ground returns to chassis does not exceed 1.0 m. This path may be used to carry DC current. 3.3.8 Closed Loop Stability The power supply is unconditionally stable under all line/load/transient load conditions including capacitive load ranges specified in Section 4.6. A minimum of: 45 degrees phase margin and 10dB-gain margin is required. The power supply manufacturer provides proof of the unit’s closed-loop stability with local sensing through the submission of Bode plots. Closed-loop stability is ensured at the maximum and minimum loads as applicable. 3.3.9 Residual Voltage Immunity in Standby Mode The power supply is immune to any residual voltage placed on its outputs (Typically a leakage voltage through the system from standby output) up to 500mV. There is no additional heat generated, nor stressing of any internal components with this voltage applied to any individual or all outputs simultaneously. It also does not trip the protection circuits during turn on. The residual voltage at the power supply outputs for no load condition does not exceed 100mV when AC voltage is applied and the PSON# signal is de-asserted. 3.3.10 Common Mode Noise The Common Mode noise on any output does not exceed 350mVp-p over the frequency band of 10Hz to 20MHz. 1. The measurement is made across a 100Ω resistor between each of DC outputs, including ground at the DC power connector and chassis ground (power subsystem enclosure). 2. The test set-up uses a FET probe such as Tektronix model P6046 or equivalent. 3.3.11 Soft Starting The Power Supply contains control circuit which provides monotonic soft start for its outputs without overstress of the AC line or any power supply components at any specified AC line or load conditions. 30 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS 3.3.12 Power Subsystem Zero Load Stability Requirement When the power subsystem operates in a no load condition, it does not need to meet the output regulation specification, but it must operate without any tripping of over-voltage or other fault circuitry. When the power subsystem is subsequently loaded, it begins to regulate and source current without fault. 3.3.13 Hot Swap Requirement Hot swapping a power supply is the process of inserting and extracting a power supply from an operating power system. During this process the output voltages remain within the limits with the capacitive load specified. The hot swap test is conducted when the system is operating under static, dynamic, and zero loading conditions. The power supply uses a latching mechanism to prevent insertion and extraction of the power supply when the AC power cord is inserted into the power supply. 3.3.14 Forced Load Sharing The +12V output has active load sharing. The output shares within 10% at full load. The failure of a power supply does not affect the load sharing or output voltages of the other supplies still operating. The supplies can load share in parallel and operate in a hot-swap/redundant 1+1 configurations. The 12VSB output is not required to actively share current between power supplies (passive sharing). The 12VSB outputs of the power supplies are connected together in the system so that a failure or hot swap of a redundant power supply does not cause these outputs to go out of regulation in the system. 3.3.15 Timing Requirement These are the timing requirements for the power supply operation. The output voltages rise from 10% to within regulation limits (Tvout_rise) within 5 to 70ms. For 12VSB, it is allowed to rise from 1.0 to 25ms. All outputs must rise monotonically. Table below shows the timing requirements for the power supply being turned on and off through the AC input, with PSON held low and the PSON signal, with the AC input applied. Table 25. Timing Requirement Item Description Min 5.0 * Max Units 70 * ms Tvout_rise Output voltage rise time. T sb_on_delay Delay from AC being applied to 12VSB being within regulation. 1500 ms T ac_on_delay Delay from AC being applied to all output voltages being within regulation. 3000 ms T vout_holdup Time 12Vl output voltage stay within regulation after loss of AC. 13 ms T pwok_holdup Delay from loss of AC to de-assertion of PWOK. 10.6 ms T Delay from PSON# active to output voltages within regulation limits. 5 pson_on_delay T pson_pwok Delay from PSON# deactivate to PWOK being de-asserted. T pwok_on Delay from output voltages within regulation limits to PWOK Revision 2.2 Intel order number: G39462-013 100 400 ms 5 ms 500 ms 31 Intel® Server System H2000JF Family TPS Power Subsystem Item Description Min Max Units asserted at turn on. T pwok_off Delay from PWOK de-asserted to output voltages dropping out of regulation limits. 1 ms T pwok_low Duration of PWOK being in the de-asserted state during an off/on cycle using AC or the PSON signal. 100 ms T sb_vout Delay from 12VSB being in regulation to O/Ps being in regulation at AC turn on. 50 Time 12VSBoutput voltage stays within regulation after loss of AC. 70 T 12VSB_holdup 1000 ms ms Note: * The 12VSTB output voltage rise time is from 1.0ms to 25ms. AC Input Tvout_holdup Vout Tpwok_low TAC_on_delay Tsb_on_delay PWOK 12Vsb Tpwok_off Tpwok_on Tsb_on_delay Tpwok_on Tpwok_holdup Tsb_vout Tpwok_off Tpson_pwok T5Vsb_holdup Tpson_on_delay PSON AC turn on/off cycle PSON turn on/off cycle Figure 16. Turn On/Off Timing (Power Supply Signals) 3.4 Power Supply Cold Redundancy Support Power supplies that support cold redundancy can be enabled to go into a low-power state (that is, cold redundant state) in order to provide increased power usage efficiency when system loads are such that both power supplies are not needed. When the power subsystem is in Cold Redundant mode, only the needed power supply to support the best power delivery efficiency is ON. Any additional power supplies, including the redundant power supply, are in Cold Standby state. Each power supply has an additional signal that is dedicated to supporting Cold Redundancy, CR_BUS. This signal is a common bus between all power supplies in the system. CR_BUS is 32 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS Power Subsystem asserted when there is a fault in any power supply OR the power supplies output voltage falls below the Vfault threshold. Asserting the CR_BUS signal causes all power supplies in Cold Standby state to power ON. Enabling power supplies to maintain best efficiency is achieved by looking at the Load Share bus voltage and comparing it to a programmed voltage level through a PMBus* command. Whenever there is no active power supply on the Cold Redundancy bus driving a HIGH level on the bus all power supplies are ON irrespective of their defined Cold Redundant roll (active or Cold Standby). This guarantees that incorrect programming of the Cold Redundancy states of the power supply will never cause the power subsystem to shut down or become over loaded. The default state of the power subsystem is all power supplies ON. There needs to be at least one power supply in Cold Redundant Active state or Standard Redundant state to allow the Cold Standby state power supplies to go into Cold Standby state. Caution: Installing two Power Supply Units with different wattage ratings on a system is not supported. This does not provide Power Supply Redundancy and causes the system to log multiple errors. 3.4.1 1200W CRPS Cold Redundancy If the output power is less than 480W (40%), the Cold redundant function will be enabled. Thus you will see one PSU working normal and the second PSU will be in CR mode. The Power Supply LED will be blinking green. Table 26. 1200W CRPS Cold Redundancy Threshold Cold Standby 1 (02h) 3.4.2 Enable (V) percent power (W) Disable (V) percent power (W) 3.2 40.00% 480(±5%) 1.44 18.00% 432(±5%) 1600W CRPS Cold Redundancy If the output power is less than 640W (40%), the Cold redundant function will be enabled. Thus you will see one PSU working normal and the second PSU will be in CR mode. The Power Supply LED will be blinking green. Table 27. 1600W CRPS Cold Redundancy Threshold Cold Standby 1 (02h) 3.5 Enable (V) percent power (W) Disable (V) percent power (W) 3.2 40.00% 640(±5%) 1.44 18.00% 576(±5%) Control And Indicator Functions The following sections define the input and output signals from the power supply. Signals that can be defined as low true use the following convention: Signal# = low true Revision 2.2 Intel order number: G39462-013 33 Intel® Server System H2000JF Family TPS Power Subsystem 3.5.1 PSON# Input Signal # The PSON signal is required to remotely turn on/off the power supply. PSON# is an active low signal that turns on the +12V power rail. When this signal is not pulled low by the system, or left open, the outputs (except the +12VSB) turn off. This signal is pulled to a standby voltage by a pull-up resistor internal to the power supply. Refer to the following table for the timing diagram. Table 28. PSON# Signal Characteristics Signal Type PSON# = Low PSON# = High or Open Logic level low (power supply ON) Logic level high (power supply OFF) Source current, Vpson = low Power up delay: Tpson_on_delay PWOK delay: T pson_pwok 3.5.2 Accepts an open collector/drain input from the system. Pull-up to VSB located in power supply. ON OFF MIN MAX 0V 1.0V 2.0V 3.46V 4mA 5msec 400msec 50msec PWOK (Power Good) Output Signal PWOK is a power OK signal and will be pulled HIGH by the power supply to indicate that all the outputs are within the regulation limits of the power supply. When any output voltage falls below regulation limits or when AC power has been removed for a time sufficiently long so that power supply operation is no longer guaranteed, PWOK will be de-asserted to a LOW state. See the table below for a representation of the timing characteristics of PWOK. The start of the PWOK delay time is inhibited as long as any power supply output is in current limit. Table 29. PWOK Signal Characteristics Signal Type PWOK = High PWOK = Low Power OK Power Not OK Logic level low voltage, Isink=400uA Logic level high voltage, Isource=200A Sink current, PWOK = low Source current, PWOK = high PWOK delay: Tpwok_on PWOK rise and fall time Power down delay: Tpwok_off 3.5.3 MIN 0V 2.4V 100ms 1ms MAX 0.4V 3.46V 400uA 2mA 1000ms 100sec 200msec SMBAlert# Signal This signal indicates that the power supply is experiencing a problem that the user should investigate. This is asserted due to Critical events or Warning events. The signal is activated in case the critical component temperature reaches a warning threshold, general failure, over- 34 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS Power Subsystem current, over-voltage, under-voltage, or failed fan. This signal may also indicate the power supply is reaching its end of life or is operating in an environment exceeding the specified limits. This signal is to be asserted in parallel with LED turning solid Amber or blinking Amber. Table 30. SMBAlert# Signal Characteristics Signal Type (Active Low) Alert# = High Alert# = Low Logic level low voltage, Isink=4 mA Logic level high voltage, Isink=50 A Sink current, Alert# = low Sink current, Alert# = high Alert# rise and fall time 3.6 Open collector/drain output from power supply. Pullup to VSB located in system. OK Power Alert to system MIN MAX 0V 0.4 V 3.46 V 4 mA 50 A 100 s Protection Circuits Protection circuits inside the power supply cause only the power supply’s main outputs to shut down. If the power supply latches off due to a protection circuit tripping, an AC cycle OFF for 15sec and a PSON# cycle HIGH for 1sec will be able to reset the power supply. 3.6.1 Current Limit (OCP) The power supply has current limit to prevent the outputs from exceeding the values shown in table below. If the current limits are exceeded, the power supply will shut down and latch off. The latch will be cleared by toggling the PSON# signal or by an AC power interruption. The power supply will not be damaged from repeated power cycling in this condition. 12VSB will be auto-recovered after removing OCP limit. Table 31. Over Current Protection Output Voltage PSU SKU +12V +12VSTB 3.6.2 Input Voltage Range 90 – 264VAC 90 – 264VAC Over Current Limits 1200W 1600W 140A min; 170A max 180A min; 200A max 2.5A min; 3A max 2.5A min; 3A max Over Voltage Protection (OVP) The power supply over voltage protection is locally sensed. The power supply will shut down and latch off after an over voltage condition occurs. This latch will be cleared by toggling the PSON# signal or by an AC power interruption. The values are measured at the output of the power supply’s connectors. The voltage does never exceed the maximum levels when measured at the power connectors of the power supply connector during any single point of fail. The voltage does never trip any lower than the minimum levels when measured at the power connector. 12VSB will be auto-recovered after removing OVP limit. Revision 2.2 Intel order number: G39462-013 35 Intel® Server System H2000JF Family TPS Power Subsystem Table 32. Over Voltage Protection (OVP) Limits Output Voltage +12V +12VSB 3.6.3 MIN (V) 13.3 13.3 MAX (V) 14.5 14.5 Over Thermal Protection (OTP) The power supply is protected against over temperature conditions caused by loss of fan cooling or excessive ambient temperature. In an OTP condition the PSU will shut down. When the power supply temperature drops to within specified limits, the power supply will restore power automatically, while the 12VSB remains always on. The OTP circuit has built-in margin so that the power supply does not oscillate on and off due to temperature recovering condition. The OTP trip level has a minimum of 4C of ambient temperature margin. 3.7 PMBus* The PMBus* features are requirements for power supply unit for use in server systems. This specification is based on the PMBus* specifications part I and II, revision 1.1. The power supply device address locations are shown below. Figure 17. Power Supply Device Address The PMBus* from PDB is connected to BMC of all four nodes. Only one board BMC is assigned to be the master BMC and communicate with PSU as single point. Other board BMCs receive PSU data from the master BMC. In case the master BMC is down, one of the slave board BMC will be promoted automatically as master BMC and maintain communication. 3.7.1 PSU Address Lines A0 Address pins A0 is used by end use system to allocate unit address to a power supply in particular slot position. 36 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS Power Subsystem For redundant systems there are two signals to set the address location of the power supply after it is installed in the system, Address0 and Address1. For non-redundant systems the power supply device address locations align with the Address0/Address1 location of 0/0. Table 33. PSU Addressing 3.7.2 PDB addressing Address0 0 1 Power supply PMBus* device B0h B2h Accuracy The sensor commands meet the following accuracy requirements. The accuracies are met over the specified ambient temperature and the full range of rated input voltage. Table 34. PMBus* Accuracy Output Loading 10% - 20% READ_PIN and READ_EIN > 20% - 50% See graphs below READ_FAN +/-500 RPM READ_IOUT +/-5% +/-2% READ_TEMPERATURE +/-2% +/- 3ºC Accuracy, +/-W Accuracy, +/-% PMBus Input power monitoring accuracy 6.0% 25 5.0% 20 4.0% 15 3.0% 10 2.0% Accuracy, +/- W Accuracy, +/-% > 50% - 100% 5 1.0% 950 1000 900 850 800 750 700 650 600 550 500 450 400 350 300 250 200 150 50 100 0 37.5 0.0% Input power, W Figure 18. PMBus* Monitoring Accuracy 3.8 Power Management Policy When working with Intel® Server Board S2600JF, the BMC on each node will monitor its fans and temperature for critical failures. When there is a fan failure and a critical temperature event Revision 2.2 Intel order number: G39462-013 37 Intel® Server System H2000JF Family TPS Power Subsystem at the same time, the node will be powered down. When this occurs, the node will need to be manually powered back on. When system power is beyond 1200W or 1600W in 1+1 mode that it automatically shifts from 1+1 mode to 2+0 mode if power load is high so that would be expected behavior on H2000JF system. Additionally on Intel® Server Board S2600JF, the BMC on node 3 and node 4 will monitor for a power supply over current condition or power supply over temperature condition. If either of these occurs and the Shutdown Policy has been enabled, the node will be powered down. When this occurs, the node will need to be manually powered back on. However, if the over current or over temperature event is detected again, the node will be powered back off. The following table shows the scheme of system power redundancy mode with node behavior. Table 35. Power Management Policy Intel®Server System H2000 Intel®Server System H2000 System Power Redundancy Load with 2x 1200W Load with 2x 1600W Mode supplies supplies System Power Load Unconstrained <1200W <1600W Redundant Mode 1200W< current load < 1800W 1600W< current load < 2160W Optimal Redundant Mode >1800W >2160W Non Redundant Mode System behavior with one PSU AC lost or failed No system throttling. All four nodes work normally. With BIOS setting “server management – shutdown policy” set to “disable”, all nodes in the system may be throttled to maintain power. This may cause lower performance. With BIOS “server management – shutdown policy” set to “enable”, Nodes 3 and 4 will shut down while Nodes 1 and 2 keep running without throttling. Node 1 and Node 2 will have no performance loss. All nodes in the system may shut down. The Shutdown Policy setting is only shown on Node 3 and Node 4, and is disabled by default but can be enabled or disabled in the BIOS setup Server Management page or by using the Set Shutdown Policy command. Caution: Installing two Power Supply Units with different wattage ratings on a system is not supported. This does not provide Power Supply Redundancy and causes the system to log multiple errors. 38 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS 4. Cooling Subsystem Cooling Subsystem The chassis cooling system contains the fan cooling subsystem of each node and common fan cooling in the power supply units. Both node fans and PSU fans work together as thermal solution to the chassis. For each node, several components and configuration requirements make up the cooling subsystem. These include processors, chipsets, VR heatsinks, system fan module, CPU air duct, and drive bay population. All are necessary to provide and regulate the air flow and air pressure needed to maintain the system’s thermals when operating at or below the maximum specified thermal limits. In order to maintain the necessary airflow within the system, you must properly install the air duct, HDD dummy carrier, PSU dummy filler, and the top cover. Each node uses a variable fan speed control engine to provide adequate cooling for the node and whole system at various ambient temperature conditions, under various server workloads, and with the least amount of acoustic noise possible. The fans operate at the lowest speed for any given condition to minimize acoustics. Note: The server system does not support redundant cooling fans. If any of the node fans fail, you must power down the respective node as soon as possible to replace the fan. 4.1 Processor Heatsink A heatsink is included in the system package. This heatsink is designed for optimal cooling and performance. To achieve better cooling performance, you must properly attach the heatsink bottom base with TIM (thermal interface material). ShinEtsu* G-751 or 7783D or Honeywell* PCM45F TIM is recommended. The mechanical performance of the heatsink must satisfy mechanical requirement of Intel® Xeon® E5-2600 series processors. To keep chipsets and VR temperature at or below maximum temperature limit, the heatsink is required if necessary. Figure 19. Processor Heatsink Overview Note: The passive heatsink is Intel standard thermal solution for 1U/2U rack chassis. Revision 2.2 Intel order number: G39462-013 39 Cooling Subsystem 4.2 Intel® Server System H2000JF Family TPS Node Cooling Fans The cooling subsystem for each node consists of three 40 x 40 x 56 dual rotor fans, and CPU air duct. These components provide the necessary cooling and airflow to the system node. To maintain the necessary airflow within the system, the air duct and the top cover must be properly installed. Note: The Intel® Server System H2000JF Family does not support redundant cooling. If one of the node fan fails, it is recommended to replace the failed fan as soon as possible. However, the system design still reserves limited thermal margin to fan failure. For Intel® Server System H2312JF with 12x 3.5'' HDD, the system allows one fan fail at one time per node with ASHRAE-A2. Certain level of CPU throttling will occur during fan fail but the percent is below 1% which is considered to be acceptable from thermal perspective. For 130W CPU configuration, the confidence level of system exit air temperature to meet 70°C is 98% which is acceptable. For 95W CPU configuration, the system exit air temperature can meet 70°C specification. All other system components are within thermal specification. For Intel® Server System H2216JF with 16x 2.5'' HDD, the system allows one fan fail at one time per node with ASHRAE-A2. There is no throttling on CPU. All other system components are within thermal specification. Each fan within the node can support multiple speeds. Fan speed changes automatically when internal ambient temperature of the system or processor temperature changes. The fan speed control algorithm is programmed into the server board’s BIOS. Each fan connector within the module supplies a tachometer signal that allows the BMC to monitor the status of each fan. If one of the fans fails, the system fault LED in the front panel will light up. The fan control signal is from BMC on mother board to Node Docking Board and then distribute to three sets of dual rotor fans. See below for detail. 40 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS Cooling Subsystem Figure 20. Node Fan Set and Power/Control Connection The fan connector pin-out definition is as follows. Table 36. 8-Pin Connector Pin-Out for Node Dual Rotor Fans 4.3 Pin 1 GND Signal Name Ground Description 2 P12V Power Supply +12 V 3 Tach1 Out FAN_TACH1 signal output 4 PWM1 In PWM1 signal input 5 GND Ground 6 P12V Power Supply +12 V 7 Tach2 Out FAN_TACH2 signal output 8 PWM1 In PWM1 signal input Power Supply Fan Each power supply module supports one non-redundant dual rotor 40 mm fan. The fans control the cooling of the power supply and some drive bays. These fans are not replaceable. Therefore, if a power supply fan fails, you must replace the power supply module. 4.4 Air Duct Module Each node requires the use of an air duct module to direct airflow over critical areas within the node. Before slide the node tray into chassis, make sure the air duct is installed properly. Revision 2.2 Intel order number: G39462-013 41 Intel® Server System H2000JF Family TPS Cooling Subsystem Figure 21. Compute Node Air Duct (Top View) 4.5 Drive Bay Population Requirement In order to maintain system thermal requirements, you must fully populate all hard drive bays. Hard drive trays used for hot-swap drives must either have a hard drive installed or not have a hard drive installed. If only one power supply unit is used, a PSU dummy filler must be used to match the airflow requirement. Important Note: If the drive bay is missing or not fully populated, the system will not meet the thermal cooling requirements of the processor, which will most likely result in degraded performance as a result of throttling or thermal shutdown of the system. It is recommended to keep/apply the dummy plastic blocker (as shipped with HDD carrier) on any blank HDD carrier. 42 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS 5. System Boards in the Node Tray System Boards in the Node Tray The Node tray includes mother board, node docking board, bridge board, and node fan set. A B C D Node Docking Board Node Fan Set Baseboard Bridge Board Figure 22. Compute Node Tray Overview 5.1 5.1.1 Node Docking Board Overview of Node Docking Board The Node Docking Board provides hot swap docking of 12V main power between the compute node and the server. It supports three dual rotor fan connections, 12V main power hot swap controller, and current sensing. The HW Power Docking Board is intended to support the usage of compute node of Intel® Server Board S2600JF family. A B C D E F 2x6 pin Minifit Jr main power output connector 8 pin connector for node fan 2 12 pin connector for main power input 8 pin connector for node fan 3 8 pin connector for node fan 1 2x7 pin fan control connector Figure 23. Node Docking Board Revision 2.2 43 Intel order number: G39462-013 Intel® Server System H2000JF Family TPS System Boards in the Node Tray The Node Docking Board implements the following features: Main 12V hot swap connectivity between compute node and chassis power. Current sensing of 12V main power for use with node manager. One 2x6pin mini-fit jr high current connectors for cabling either the HW baseboard or a double width add-in card in a customized chassis. Different cable lengths will be needed for the different depth HW baseboards. 2x7pin fan single connector, discrete cabled to the HW baseboard. Three 8-pin dual rotor fan connectors. Four loose screws used to secure board to the compute node. 5.1.2 Pin-out Definition on Node Docking Board The table below lists the connector type and pin definition on Node Docking Board. Table 37. Main Power Input Connector Pin 1 3 5 7 9 11 Signal Description Pin Lower Blade (Circuit 1) GND 2 GND 4 GND 6 Upper Blade (Circuit 2) P12V 8 P12V 10 P12V 12 Signal Description GND GND GND P12V P12V P12V Table 38. Fan Control Signal Connector Pin 1 3 5 7 9 11 13 Signal Description PWM1 Tach0 Tach2 Tach4 NODE_ON SMBUS_R4 CLK NODE_ADR0 Pin 2 4 6 8 10 12 14 Signal Description Reserved Tach1 Tach3 Tach5 GND SMBUS_R4 DAT NODE_PWRGD Table 39. Node Fan Connector Pin 1 2 3 4 5 6 7 8 44 Signal Description GND P12V TACH1 PWM1 GND P12V TACH2 PWM1 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS System Boards in the Node Tray Table 40. Main Power Output Connector Pin 1 2 3 4 5 6 5.2 Signal Description GND GND GND GND GND GND Pin 7 8 9 10 11 12 Signal Description P12V_HS P12V_HS P12V_HS P12V_HS P12V_HS P12V_HS Bridge Board There are several types of bridge boards that implement different features and functions when working with Intel® Server Board S2600JF family. This section describes the common bridge board which is shipping with H2000JF system. 5.2.1 Overview of Bridge Board The bridge board is a common board across all baseboards going into the H2000JF serials server chassis. The bridge board provides hot swap interconnect of all electrical signals to the backplane of the server chassis (except for main 12V power). It supports up to 4x lanes of SAS/SATA, a 7-pin SATA connector for SATA DOM devices, and type-A USB connector for USB flash device. One bridge board is used per one compute node. The bridge board is secured with three loose screws to the compute node tray. Figure 24. Bridge Board Overview Bridge board passes all electrical connectivity through a 2x40pin card edge hot swap interconnect between compute node and chassis backplane. The bridge board passes the following features (per compute node) to the backplane of the server: Revision 2.2 45 Intel order number: G39462-013 Intel® Server System H2000JF Family TPS System Boards in the Node Tray 4x 6Gb SAS/SATA ports for HSBP drives Two x4 lane 6Gb SAS/SATA re-drivers Four chassis ID signals to determine the physical location of the compute node One SGPIO SFF-8485 interface to the HSBP microcontroller 5V_AUX power generated on HSBP and provided to the compute node 3.3V power generated on HSBP and provided to bridge board to run SAS/SATA redrivers Global PMBus* alert signal for CLST support Four SMBus* interfaces: o SMBUS* R1: For chassis temp sensor and chassis FRU EEPROM device o SMBUS* R5: Connectivity to up to two HSBP controllers and one shared .12V current monitoring device o SMBUS* R7: Connectivity to up to two common redundant power supply (CRPS) module PMBus* o IPMB: For OEM requirement not used on EPSD HW servers o Front panel button signals: Power, reset, NMI, and ID o Front panel LEDs signals: Power, fault, status, fabric activity, ID, HDD activity One 7-pin 6Gb SATA port connector for DOM device docking to the bridge board USB2.0 interface to a 4-pin type-A connector for flash device docking to bridge board 2-Pin 5V_AUX power for the SATA DOM in need of cabling power A B C D E 2x40 pin card edge connector (to backplane) USB 2.0 Type-A connector 2-pin 5V_AUX power AHCI SATA0 DOM port connector 2x40 pin card edge connector (to baseboard slot) Figure 25. Connectors on Bridge Board 46 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS 5.2.2 System Boards in the Node Tray Pin-out Definition on Bridge Board The table below lists the connector pin definition on the bridge board. Table 41. Card Edge Connector Pin-out Pin 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 65 67 69 71 73 75 77 79 Signal Description 5V Aux SATA0_TXN SATA0_TXP GND NODE_PRESENT_N (GND) ALL_NODE_OFF spare GND IPMB-Data IPMB-Clk GND SMBUS_R1 DATA SMBUS_R1 CLK GND SMBUS_R5 DATA SMBUS_R5 CLK GND SMBUS_R7 DATA SMBUS_R7 CLK GND PMBUS Alert_N NODEx_ON_N SGPIO DATA IN SGPIO Data Out SGPIO LD SPKR GND SAS3_RX SAS3_RX GND SAS2_TX SAS2_TX GND SAS1_RX SAS1_RX GND SAS0_TX SAS0_TX GND P3V3 (HSBP Side) and GND (HW Baseboard Side) Pin 2 4 6 8 Signal Description 5V Aux USB2_OC GND SATA0_RXN 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 SATA0_RXP GND USB2_P0P USB2_P0N GND FP HDD_ACT_LED_N FP Activity LED_N FP Health LEDA_N FP Health LEDG_N FP PWR LED_N FP ID LED_N FP ID BTN_N FP RST BTN_N FP PWR BTN_N FP NMI BTN_N SPA_SOUT_N SPA_SIN_N ID3 ID2 ID1 ID0 SGPIO CLK GND SAS3_TX SAS3_TX GND SAS2_RX SAS2_RX GND SAS1_TX SAS1_TX GND SAS0_RX SAS0_RX GND P3V3 (HSBP Side) and SATA_SAS_N (HW Baseboard Side) 80 Revision 2.2 47 Intel order number: G39462-013 Intel® Server System H2000JF Family TPS System Boards in the Node Tray The SATA DOM used on SATA0 port can be either powered by the SATA port, or using external power from 5V-AUX connector. Table 42. AHCI SATA0 DOM Connector Pin-out Pin 1 2 3 4 5 6 7 Signal Description GND SATA0_TXP SATA0_TXN GND SATA0_RXN SATA0_RXP P5V_SATA/GND Table 43. USB 2.0 Type-A Connector Pin-out Pin 1 2 3 4 Signal Description P5V_USB USB2_P0N USB2_P0P GND Table 44. 5V_AUX Power Connector Pin-out Pin 1 2 5.3 Signal Description GND P5V 6Gbs SAS Support Option 1 This bridge board is designed to support 6Gbs SAS signal from internal SAS RAID controller. This bridge board is not connect to SCU ports from baseboard but makes all other power and control signals available to backplane. It ships together with a dedicated SAS cable as a spare of the system. 5.3.1 Overview of Bridge Board The bridge board is a spare board across all baseboards going into the H2000JF serials server chassis, to upgrade the system for 6Gbs SAS support. The bridge board provides hot swap interconnect of all electrical signals to the backplane of the server chassis (except for main 12V power). It supports up to 4x lanes of SAS/SATA and one mini SAS connector for cable connection to PCIe based RAID card or SAS ROC. One bridge board is used per one compute node. The bridge board is secured with several loose screws to the compute node tray. A dedicated mini SAS cable is shipped together with the bridge board, which is mechanically fitted into the node tray. 48 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS System Boards in the Node Tray Figure 26. SAS 6Gbs Bridge Board Overview This bridge board passes all electrical connectivity through a 2x40pin card edge hot swap interconnect between compute node/SAS RAID card and chassis backplane. The bridge board passes the follow features (per compute node) to the backplane of the server: 4x 6Gb SAS/SATA signals through Mini SAS port to HSBP drives Two x4 lane 6Gb SAS/SATA re-drivers Four chassis ID signals to determine the physical location of the compute node One SGPIO SFF-8485 interface to the HSBP microcontroller 5V_AUX power generated on HSBP and provided to the compute node 3.3V power generated on HSBP and provided to bridge board to run SAS/SATA redrivers Global PMBus* alert signal for CLST support Four SMBus* interfaces: o SMBus* R1: For chassis temp sensor and chassis FRU EEPROM device o SMBus* R5: Connectivity to up to two HSBP controllers and one shared .12V current monitoring device o SMBus* R7: Connectivity to up to two common redundant power supply (CRPS) module PMBus* o IPMB: For OEM requirement not used on EPSD HW servers o Front panel button signals: Power, reset, NMI, and ID o Front panel LEDs signals: Power, fault, status, fabric activity, ID, and HDD activity Revision 2.2 49 Intel order number: G39462-013 Intel® Server System H2000JF Family TPS System Boards in the Node Tray A B C 2x40 pin card edge connector (to backplane) 2x40 pin card edge connector (to baseboard bridge slot) 4-port Mini SAS Connector Figure 27. Connectors and Components on Spare Bridge Board 5.3.2 Pin-out Definition on SAS 6Gbs Bridge Board The table below lists the connector pin definition on the bridge board. Table 45. Pin-out of Card Edge to Base Board Pin 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 50 Signal Name 5V_AUX N/C N/C GND NODE_PRESENT_N ALL_NODE_OFF N/C GND IPMB_DATA IPMB_CLK GND SMB_SNSR_DATA SMB_SNSR_CLK GND SMB_HSBP_DATA SMB_HSBP_CLK GND SMB_PMBUS_DATA SMB_PMBUS_CLK GND Pin 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 Signal Name 5V_AUX USB2_OC GND N/C N/C GND N/C N/C GND LED_HDD_ACT_N FP_ACT_LED_N FP_LED_STSA_N FP_LED_STSG_N FP_PWR_LED_N FP_ID_LED_N FP_ID_BTN_N FP_RST_BTN_N FP_PWR_BTN_N FP_NMI_BTN_N SPA_SOUT Pin 41 43 45 47 49 51 53 55 57 59 61 63 65 67 69 71 73 75 77 79 Signal Name PMBUS_ALERT_N NODE_ON_N SGPIO_DATA_IN SGPIO_DATA_OUT SGPIO_LOAD SPEAKER_IN GND N/C N/C GND N/C N/C GND N/C N/C GND N/C N/C GND GND Intel order number: G39462-013 Pin 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 Signal Name SPA_SIN IBMC_NODEID_3 IBMC_NODEID_2 IBMC_NODEID_1 IBMC_NODEID_0 N/C GND N/C N/C GND N/C N/C GND N/C N/C GND N/C N/C GND SAS_SATA_SET_N Revision 2.2 Intel® Server System H2000JF Family TPS System Boards in the Node Tray Table 46. Pin-out of Card Edge to Hot Swap Back Plane Pin 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 Signal Name 5V_AUX N/C N/C GND NODE_PRESENT_N ALL_NODE_OFF 3V3_AUX GND IPMB_DATA IPMB_CLK GND SMB_R1_DATA SMB_R1_CLK GND SMB_HSBP_DATA SMB_HSBP_CLK GND SMB_PMBUS_DATA SMB_PMBUS_CLK GND Pin 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 Signal Name 5V_AUX N/C GND N/C N/C GND N/C N/C GND LED_HDD_ACT_N FP_ACT_LED_N FP_LED_STSA_N FP_LED_STSG_N FP_PWR_LED_N FP_ID_LED_N FP_ID_BTN_R_N FP_RST_BTN_N FP_PWR_BTN_N FP_NMI_BTN__N SPA_SOUT Pin 41 43 45 47 49 51 53 55 57 59 61 63 65 67 69 71 73 75 77 79 Signal Name PMBUS_ALERT_N NODE_ON_N SGPIO_DATA_IN SGPIO_DATA_OUT SGPIO_LOAD SPEAKER_IN GND SAS3_RX_BP_N SAS3_RX_BP_P GND SAS2_TX_BP_N SAS2_TX_BP_P GND SAS1_RX_BP_N SAS1_RX_BP_P GND SAS0_TX_BP_N SAS0_TX_BP_P GND 3V3 Pin 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 Signal Name SPA_SIN IBMC_NODEID_3 IBMC_NODEID_2 IBMC_NODEID_1 IBMC_NODEID_0 SGPIO_CLOCK GND SAS3_TX_BP_N SAS3_TX_BP_P GND SAS2_RX_BP_N SAS2_RX_BP_P GND SAS1_TX_BP_N SAS1_TX_BP_P GND SAS0_RX_BP_N SAS0_RX_BP_P GND 3V3 Table 47. Pin-out of Mini SAS Connector Pin Signal Name Pin Signal Name Pin Signal Name Pin Signal Name A1 GND A10 GND B1 GND B10 SGPIO_DATA_OUT A2 A3 A4 A5 SAS0_TX_P SAS0_TX_N GND SAS1_TX_P A11 A12 A13 A14 N/C GND SAS2_TX_P SAS2_TX_N B2 B3 B4 B5 SAS0_RX_P SAS0_RX_N GND SAS1_RX_P B11 B12 B13 B14 SGPIO_DATA_IN GND SAS2_RX_P SAS2_RX_N A6 A7 SAS1_TX_N GND A15 A16 GND SAS3_TX_P B6 B7 SAS1_RX_N GND B15 B16 GND SAS3_RX_P A8 A9 SGPIO_CLOCK SGPIO_LOAD A17 A18 SAS3_TX_N GND B8 B9 SAS_BP_TYPE N/C B17 B18 SAS3_RX_N GND 5.4 6Gbs SAS Support Option 2 The dedicated 6Gbs SAS controller RMS25LB040 is designed for Intel® Server System H2000JF, together with dedicated bridge board and riser card as total solution kit. This solution leaves the PCIe slot 1 available for additional LP PCIe base add-in card. The solution kit includes three major parts: bridge board, riser card, and SAS controller module. 5.4.1 Bridge Board The bridge board in the solution kit is shown below. The original bridge board in the base system must be replaced with this bridge board in order to install the rest riser card and SAS controller module. Revision 2.2 51 Intel order number: G39462-013 System Boards in the Node Tray Intel® Server System H2000JF Family TPS Figure 28. Overview of the Bridge Board Main connectors on the bridge board are defined as follows. A B C D E 2x40 pin card edge connector (to backplane) SATA DOM Connector Auxiliary SATA DOM Power 2x18 pin card edge connector (to SAS Controller) 2x40 pin card edge connector ( to bridge slot on baseboard) Figure 29. Connectors on Bridge Board The pin-out of card edge to Hot Swap Backplane is the same as defined in 52 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS System Boards in the Node Tray Table 46, and pin-out of card edge to bridge board slot is the same as defined in Table 45. The pin-out of card edge to SAS controller module is defined below. Table 48. Card Edge Pin-out of Bridge Board to SAS Controller Pin A1 A2 A3 A4 A5 A6 A7 A8 A9 Signal Name NC SGPIO_LOAD SGPIO_CLOCK GND SAS3_TX_N SAS3_TX_P GND GND SAS2_RX_N Pin B1 B2 B3 B4 B5 B6 B7 B8 B9 Signal Name GND SGPIO_DATA_IN SGPIO_DATA_OUT GND SAS3_RX_P SAS3_RX_N GND GND SAS2_TX_P Pin A10 A11 A12 A13 A14 A15 A16 A17 A18 Signal Name SAS2_RX_P GND SAS1_TX_N SAS1_TX_P GND GND SAS0_RX_N SAS0_RX_P GND Pin B10 B11 B12 B13 B14 B15 B16 B17 B18 Signal Name SAS2_TX_N GND SAS1_RX_P SAS1_RX_N GND SAS0_TX_P SAS0_TX_N GND NC Pin definition for SATA DOM and Auxiliary Power connectors are the same as defined in Table 42 and Table 44. 5.4.2 Riser Card The riser card provides electrically connectivity for installing a standard PCIe x8 Gen3 low profile form factor adapter card. It supports a PCIe Gen3 x8 card edge connection, and for passing an RGMII interface across to SAS Module. The riser card is secured with two loose screws to the compute node sheet metal bracket. Figure 30. Overview of the Riser Card Riser card pin-out definition is as follows. Table 49. Card Edge Pin-out of Riser Card to SAS Controller Pin A1 Signal Name P12V Pin B1 Signal Name P3V3_1 Pin Signal Name Pin A26 P3E_RX_DP< 5> B26 Revision 2.2 Signal Name GND 53 Intel order number: G39462-013 Intel® Server System H2000JF Family TPS System Boards in the Node Tray Pin Signal Name Pin Signal Name Pin Signal Name Pin Signal Name B27 GND B28 A2 P12V B2 P3V3_2 A27 A3 P12V B3 P3V3_3 A28 P3E_RX_DN< 5> GND A4 P12V B4 A29 GND B29 A5 B5 A30 B6 PD_P3E_PRSNT_N A31 B31 GND A7 GND B7 LED_HDD_ACT_N A32 P3E_RX_DP< 4> P3E_RX_DN< 4> GND B30 A6 SMB_CLK_P3E_P3V3 _AUX P3V3_AUX SMB_DAT_P3E_P3V3_A UX P5V_STBY P3E_TX_C_D P<5> P3E_TX_C_D N<5> GND B32 A8 RGMII_IBMC_RMM4_T XD_0 RGMII_IBMC_RMM4_T XD_1 RGMII_IBMC_RMM4_T XD_2 RGMII_IBMC_RMM4_T XD_3 GND B8 A33 GND B33 A34 B34 B35 GND A36 P3E_RX_DP< 3> P3E_RX_DN< 3> GND B36 A37 GND B37 RGMII_IBMC_RMM4_T X_CLK RGMII_IBMC_RMM4_T X_CTRL RGMII_IBMC_RMM4_ MDIO RST_P3E_N B13 RGMII_IBMC_RMM4_RX D_3 RGMII_IBMC_RMM4_RX D_2 RGMII_IBMC_RMM4_RX D_1 RGMII_IBMC_RMM4_RX D_0 RGMII_IBMC_RMM4_RX _CTRL GND P3E_TX_C_D P<4> P3E_TX_C_D N<4> GND A38 B38 RGMII_IBMC_RMM4_RX _CLK RGMII_IBMC_RMM4_M DC GND A39 B39 GND A40 P3E_RX_DP< 2> P3E_RX_DN< 2> GND P3E_TX_C_D P<3> P3E_TX_C_D N<3> GND B40 A41 GND B41 B17 B43 GND P3E_RX_DN<7> B19 A44 P3E_RX_DP< 1> P3E_RX_DN< 1> GND B42 A19 CLK_100M_P3E_REF_D P CLK_100M_P3E_REF_D N GND A42 A18 TP_IRQ_LVC3_WAKE _N P3E_RX_DP<7> P3E_TX_C_D P<2> P3E_TX_C_D N<2> GND B44 A20 GND B20 P3E_TX_C_DP<7> A45 GND B45 A21 GND B21 P3E_TX_C_DN<7> A46 P3E_RX_DP< 0> B46 P3E_TX_C_D P<1> P3E_TX_C_D N<1> GND A22 P3E_RX_DP<6> B22 GND A47 B47 GND A23 P3E_RX_DN<6> B23 GND A48 P3E_RX_DN< 0> GND B48 A24 GND B24 P3E_TX_C_DP<6> A49 GND B49 P3E_TX_C_D P<0> P3E_TX_C_D N<0> A25 GND B25 P3E_TX_C_DN<6> A9 A10 A11 A12 A13 A14 A15 A16 A17 B9 B10 B11 B12 B14 B15 B16 B18 A35 A43 Table 50. Card Edge Pin-out of Riser Card to PCIe Slot2 of Baseboard Pin Signal Name Pin Signal Name Pin Signal Name Pin P3E_RX_DP< 5> P3E_RX_DN< 5> A26 GND A27 GND B1 P12V A1 P3V3_1 B26 B2 P12V A2 P3V3_2 B27 54 Intel order number: G39462-013 Signal Name Revision 2.2 Intel® Server System H2000JF Family TPS Pin Signal Name Pin System Boards in the Node Tray Signal Name Pin Signal Name Pin Signal Name B3 P12V A3 P3V3_3 B28 GND A28 B4 P12V A4 B29 GND A29 B5 A5 B30 A6 PD_P3E_PRSNT_N B31 A31 GND B7 GND A7 LED_HDD_ACT_N B32 P3E_RX_DP< 4> P3E_RX_DN< 4> GND A30 B6 SMB_CLK_P3E_P3V3 _AUX P3V3_AUX SMB_DAT_P3E_P3V3_A UX P5V_STBY P3E_TX_C_D P<5> P3E_TX_C_D N<5> GND A32 B8 RGMII_IBMC_RMM4_T XD_0 RGMII_IBMC_RMM4_T XD_1 RGMII_IBMC_RMM4_T XD_2 RGMII_IBMC_RMM4_T XD_3 GND A8 B33 GND A33 B34 A34 A35 GND B36 P3E_RX_DP< 3> P3E_RX_DN< 3> GND A36 B37 GND A37 RGMII_IBMC_RMM4_T X_CLK RGMII_IBMC_RMM4_T X_CTRL RGMII_IBMC_RMM4_ MDIO RST_P3E_N A13 RGMII_IBMC_RMM4_RX D_3 RGMII_IBMC_RMM4_RX D_2 RGMII_IBMC_RMM4_RX D_1 RGMII_IBMC_RMM4_RX D_0 RGMII_IBMC_RMM4_RX _CTRL GND P3E_TX_C_D P<4> P3E_TX_C_D N<4> GND B38 A38 RGMII_IBMC_RMM4_RX _CLK RGMII_IBMC_RMM4_M DC GND B39 A39 GND B40 P3E_RX_DP< 2> P3E_RX_DN< 2> GND P3E_TX_C_D P<3> P3E_TX_C_D N<3> GND A40 B41 GND A41 A17 A43 GND P3E_RX_DN<7> A19 B44 P3E_RX_DP< 1> P3E_RX_DN< 1> GND A42 B19 CLK_100M_P3E_REF_D P CLK_100M_P3E_REF_D N GND B42 B18 TP_IRQ_LVC3_WAKE _N P3E_RX_DP<7> P3E_TX_C_D P<2> P3E_TX_C_D N<2> GND A44 B20 GND A20 P3E_TX_C_DP<7> B45 GND A45 B21 GND A21 P3E_TX_C_DN<7> B46 A46 B22 P3E_RX_DP<6> A22 GND B47 A47 GND B23 P3E_RX_DN<6> A23 GND B48 P3E_RX_DP< 0> P3E_RX_DN< 0> GND P3E_TX_C_D P<1> P3E_TX_C_D N<1> GND A48 B24 GND A24 P3E_TX_C_DP<6> B49 GND A49 P3E_TX_C_D P<0> P3E_TX_C_D N<0> B25 GND A25 P3E_TX_C_DN<6> B9 B10 B11 B12 B13 B14 B15 B16 B17 5.4.3 A9 A10 A11 A12 A14 A15 A16 A18 B35 B43 SAS Controller Module The SAS Module uses the LSI* 2308 host controller, totally generating up to 8ports of 6Gb SAS/SATA. SAS Module consists of a 1GbE PHY device RTL8211D which offers a dedicated management RJ45 1GbE port. 6Gb SAS Controller Module Key features: 1. LSI* 2308 SAS controller supporting up to eight 6Gb SAS/SATA ports Revision 2.2 55 Intel order number: G39462-013 System Boards in the Node Tray Intel® Server System H2000JF Family TPS 2. 3. 4. 5. 6. 7. 8. Up to x8 lanes of PCIe Gen3 allowing up to 8Gb/s per direction 16MBytes Flash ROM memory 32kByte MRAM memory for write journaling support 150MHz core clock 1.0V core & 1.0V analog VRs, and 1.8V VR Up to two universal keyed 36pin Mini-SAS connectors Up to two SFF-8485 SGPIOs (SFF-8448 complaint sideband signals on each mini-SAS connector) 9. “Heart beat” & system error status LEDs 10. 8kByte Bootstrap EEPROM 11. 256Byte chassis FRU EEPROM (unstuffed) & TMP75 temp sensor (stuffed) 12. One UART Debug headers 13. A dedicated RJ45 connector & PHY with 1Gb RGMII interface SAS Controller Module Key Components are listed below. A B C D E F G H I J RJ45 connector for 1GbE RGMII LSI* 2308 SAS Controller Riser Slot (with riser card installed) Bridge Board Slot HDD LED ACT Header Mini SAS Connector 1 (Depop) Mini SAS Connector 2 (Depop) Voltage Regulator RAID Key Header (Depop) UART Debug Header Figure 31. SAS Controller Module Overview 56 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS 6. Hard Disk Drive Support Hard Disk Drive Support The server system provides two SKUs to support different types of Hard Disk Drives (HDD): H2312JF: Supports 12x 3.5" HDD H2216JF: Supports 16x 2.5" HDD 6.1 Hard Disk Drive Bays Scheme The server system H2000 chassis can support up to 12 carrier-mounted SATA/SAS 3.5-inch hard disk drives, or 16 carrier-mounted SATA/SAS 2.5-inch hard disk drives. The drives may be “electrically” hot-swapped while the system power is applied, but you must take caution before hot-swapping while the system is functioning under operating system/application control or data may be lost. Following are hard disk drive distribution schemes on different SKUs of H2000 chassis family. Figure 32. HDD Scheme for H2312JF Figure 33. HDD Scheme for H2216JF Note: If a failed drive needs to be replaced, it is recommended you replace it with the same manufacturer, model, and capacity. 6.2 Hard Drive Carrier There are two types of HDD carriers for two chassis SKUs respectively. Revision 2.2 57 Intel order number: G39462-013 Intel® Server System H2000JF Family TPS Hard Disk Drive Support Figure 34. 3.5-inch HDD Assembly Overview Figure 35. 2.5-inch HDD Assembly Overview Hot-swap drive carriers make insertion and extraction of the drive from the system very simple. Each type of drive carrier has its own latching mechanism, which is used to both insert and extract drives from the chassis and lock the carrier in place. Each type of drive carrier supports two light pipes to direct light from the drive status LEDs on the backplane to the carrier’s face allowing it to be viewable from the front of the system. 6.3 Hot-Swap Hard Drive Support Both the Intel® Server System H2312JF and H2216JFcan support hot-swap SATA/SAS hard drives. Hard drives interface with the passive backplane through a blind mate connection when drives are installed into a hard drive bay using hot-swap drive carriers. The passive backplane acts as an intermediate pass-through interface board where SATA/SAS ports of SCU0 from server board are hard wired to the backplane. The on board Intel® C600 Chipset (PCH) provides the necessary drive interface. Each compute node in the system has dedicated Hot Swap Controller (HSC) to manage three or four HDDs. There are totally four sets of independent Programmable System On Chip (PSOC) on the backplane to function as HSC respectively to the four compute nodes. 58 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS Hard Disk Drive Support The following sections describe the feature and connections between the backplane and server board. 6.3.1 Backplane Feature Set Common HSBP Microcontroller Cypress* PSoC 1 part. H2312JF: 12x SAS/SATA 3.5" HDDs at 6Gb/s SAS/SATA or slower speeds, divided into 4 groups of three hot swap hard drives. Each HDD group is associated with one of the four compute nodes respectively in the 2U chassis. H2216JF: 16x SAS/SATA 2.5" HDDs at 6Gb/s SAS/SATA or slower speeds, divided into 4 groups of four hot swap hard drives. Each HDD group is associated with one of the four compute nodes respectively in the 2U chassis. One SGPIO SFF-8485 interface per compute node, total of four SGPIO on the backplane. Three SMBus* interfaces supported on the HSBP: o SMBus* R1: For chassis temp sensor and chassis FRU EEPROM device. o SMBus* R5: Connectivity to up to two HSBP controllers and one shared 12V current monitoring device. o SMBus* R7: Connectivity to up to two common redundant power supply (CRPS) module PMBus*. Integrated front panel control connectors. Status LED and Activity LED for each hard disk drive. 5V_AUX switcher regulator (from 12V and 12VSB) for HDD power and for compute nodes. Each grouping of HDD slots has switches for 5V and 12V power, only when corresponding compute node is plugged in and operating will power be provided to the HDDs. 3.3V switcher regulator (from 12V) to power microcontroller, SAS/SATA re-drivers on the bridge board and various other components. 3.3V_AUX linear regulator (from 5V_AUX) for temp sensor, and chassis FRU EEPROM located on the HSBP. Four 80-pin bridge board connectors, one per compute node. Four compute node main power connectors, one per compute node. Four 2x9pin power cable connections and one 2x9pin power control cable connections. These cables are routing to two power distribution boards (PDB). Shared speaker for all compute nodes. Revision 2.2 59 Intel order number: G39462-013 Intel® Server System H2000JF Family TPS Hard Disk Drive Support 6.3.2 Backplane Block Diagram Figure 36. Passive Backplane Block Diagram (for One Node) 6.3.3 3.5" Hot Swap Backplane Connector Scheme The following diagrams show the layout of major components and connectors for 3.5" Hot Swap backplane. A SATA/SAS connectors for Node 1 B SATA/SAS connectors for Node 2 C SATA/SAS connectors for Node 3 D SATA/SAS connectors for Node 4 Figure 37. 3.5" Backplane Component and Connectors (Front View) 60 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS A 20-pin Front Panel cable connector for Node 2, 4 B 2-Blade Compute Node Power connector for Node 4 C 2x40 pin Bridge Board connector for Node 4 D 2x9 pin Power supply input connector E 2x9 pin Power supply input connector F 2x7 pin Power Control cable connector G 2-Blade Compute Node Power connector for Node 3 H 2x40 pin Bridge Board connector for Node 3 I 2x40 pin Bridge Board connector for Node 1 J 20-pin Front Panel cable connector for Node 1, 3 K 2-Blade Compute Node Power connector for Node 1 L 2x9 pin Power supply input connector M 2x9 pin Power supply input connector N 2x40 pin Bridge Board connector for Node 2 O 2-Blade Compute Node Power connector for Node 2 Hard Disk Drive Support Figure 38. 3.5" Backplane Component and Connectors (Back View) 6.3.4 2.5" Hot Swap Backplane Connector Scheme The following diagrams show the layout of major components and connectors for 2.5" Hot Swap backplane. Revision 2.2 61 Intel order number: G39462-013 Intel® Server System H2000JF Family TPS Hard Disk Drive Support A SATA/SAS connectors for Node 1 B SATA/SAS connectors for Node 2 C SATA/SAS connectors for Node 3 D SATA/SAS connectors for Node 4 Figure 39. 2.5" Backplane Component and Connectors (Front View) A 2-Blade Compute Node Power connector for Node 4 B 2x40 pin Bridge Board connector for Node 4 C 2x9 pin Power supply input connector D 2x7 pin Power Control cable connector E 2x9 pin Power supply input connector F 2-Blade Compute Node Power connector for Node 3 G 2x40 pin Bridge Board connector for Node 3 H 2x40 pin Bridge Board connector for Node 1 I 20-pin Front Panel cable connector for Node 1, 3 J 2-Blade Compute Node Power connector for Node 1 K 2x9 pin Power supply input connector L 2x9 pin Power supply input connector M 2x40 pin Bridge Board connector for Node 2 N 2-Blade Compute Node Power connector for Node 2 O 20-pin Front Panel cable connector for Node 2, 4 Figure 40. 2.5" Backplane Component and Connectors (Back View) 62 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS 6.3.5 Hard Disk Drive Support Backplane LED Support The backplanes support both HDD online and activity/fault LEDs for each of the hard drive connectors. A light duct in HDD tray is used to conduct LED light to front panel. The following lists LED functionality. Figure 41. Hard Drive Carrier LED General HDD LED functionality is displayed below. Table 51. Hard Drive Carrier Status LED Functions Amber Off Solid On Blink No access and no fault Hard Drive Fault has occurred Raid rebuild in progress (1hz) Identify (2hz) Table 52. Hard Drive Carrier Activity LED Functions Condition Power on with no drive activity Power on with drive activity Green Power on and drive spinning down Power on and drive spinning up 6.3.6 Drive Type SAS SATA SAS SATA SAS SATA SAS SATA Behavior LED stays on. LED stays off. LED blinks off when processing a command. LED blinks off when processing a command. LED stays off. LED stays off. LED blinks. LED stays off. Backplane Connector Definition The backplanes include several different connectors. This section defines the purpose and pinout associated with each. 1. 2x9 Pin Power Input Connector The backplane is powered by +12V and +12VSTB from PDB of CRPS. The input power is distributed by backplane to all four nodes. Revision 2.2 63 Intel order number: G39462-013 Intel® Server System H2000JF Family TPS Hard Disk Drive Support Table 53. Backplane Input Power Connector Pin-out Pin 2 4 6 8 10 12 14 16 18 Signal Description P12V P12V P12V P12V P12V P12V P12V P12V P12V Pin 1 3 5 7 9 11 13 15 17 Signal Description GND GND GND GND GND GND GND GND GND 2. 2-Blade Compute Node Power Connector The backplane provides main power to compute node through 2-Blade power connector. Table 54. 2-Blade Compute Node Power Connector Pin-out Pin 1 3 5 7 9 11 13 15 Signal Description Pin Lower Blade (Circuit 1) GND 2 GND 4 GND 6 GND 8 Upper Blade (Circuit 2) P12V 10 P12V 12 P12V 14 P12V 16 Signal Description GND GND GND GND P12V P12V P12V P12V 3. 2x40 Pin Bridge Board Connector The Compute Node provides four SATA/SAS ports (in SCU0) to backplane, together with front panel control signals and SMBus*. Table 55. 2x40 Pin Connector Pin-out for Node Bridge Board Pin 1 3 5 7 9 11 13 15 17 19 64 Signal Description 5V_AUX SATA0_TXN SATA0_TXP GND NODE_Present_N (GND) ALL_NODE_OFF spare GND IPMB-Data IPMB-Clk Pin 2 4 6 8 10 12 14 16 18 20 Signal Description 5V_AUX USB2_OC GND SATA0_RXN SATA0_RXP GND USB2_P0P USB2_P0N GND FP HDD_ACT_LED_N Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS Pin 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 53 55 57 59 61 63 65 67 69 71 73 75 77 79 Signal Description GND SMBUS_R1 DATA SMBUS_R1 CLK GND SMBUS_R5 DATA SMBUS_R5 CLK GND SMBUS_R7 DATA SMBUS_R7 CLK GND PMBUS Alert_N NODEx_ON_N SGPIO DATA IN SGPIO Data Out SGPIO LD SPKR GND SAS3_RX SAS3_RX GND SAS2_TX SAS2_TX GND SAS1_RX SAS1_RX GND SAS0_TX SAS0_TX GND 3.3V Hard Disk Drive Support Pin 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 Signal Description FP Activity LED_N FP Health LEDA_N FP Health LEDG_N FP PWR LED_N FP ID LED_N FP ID BTN_N FP RST BTN_N FP PWR BTN_N FP NMI BTN_N SPA_SOUT_N SPA_SIN_N ID3 ID2 ID1 ID0 SGPIO CLK GND SAS3_TX SAS3_TX GND SAS2_RX SAS2_RX GND SAS1_TX SAS1_TX GND SAS0_RX SAS0_RX GND 3.3V 4. 20-Pin Front Panel Connector The backplanes provide connectors for front panel control signals. Each connector integrates the control signals of two compute nodes. Table 56. Front Panel Connector Pin-out Pin 1 2 3 4 5 6 7 8 Signal Description GND FP1_PWR_BTN_N FP1_RST_BTN_N FP1_ID_BTN_N P5VSB FP1_PWR_LED_N FP1_HEALTH_LEDG_N FP1_HEALTH_LEDA_N Revision 2.2 65 Intel order number: G39462-013 Intel® Server System H2000JF Family TPS Hard Disk Drive Support Pin 9 10 11 12 13 14 15 16 17 18 19 20 Signal Description FP1_ACTIVITY_LED_N FP1_ID_LED_N GND FP2_PWR_BTN_N FP2_RST_BTN_N FP2_ID_BTN_N P3V3SB FP2_PWR_LED_N FP2_HEALTH_LEDG_N FP2_HEALTH_LEDA_N FP2_ACTIVITY_LED_N FP2_ID_LED_N 5. 2x7 Pin Power Supply Control Signal Connector The backplanes provide power supply control signals, together with PMBus* functionality integrated. Table 57. Power Supply Control Connector Pin-out Pin 1 3 5 7 9 11 13 66 Signal Description SMBUS_R7_DATA SMBUS_R7_CLK PMBUS_ALERT_N PWROK Reserved PDU1-12VSB PDU2-12VSB Pin 2 4 6 8 10 12 14 Intel order number: G39462-013 Signal Description A0 PSON_N 12V RS_RTN 12V RS PDU1-12VSB PDU2-12VSB Reserved Revision 2.2 Intel® Server System H2000JF Family TPS 7. Front Panel Control and Indicators Front Panel Control and Indicators The Intel® Server System H2000JF family Front Control Panel is integrated with rack handles at the both sides of the chassis. Each control panel contains two sets of node control buttons and status LEDs. The control panel assembly is pre-assembled and fixed with the rack handles. A B C D System Power Button with LED System ID LED Button System Status LED Network Link/Activity LED Figure 42. Front Control Panel Revision 2.2 67 Intel order number: G39462-013 Intel® Server System H2000JF Family TPS Front Panel Control and Indicators 7.1 Control Panel Button The following table lists the control panel features and functions. The control panel features a system power button. Table 58. Front Control Button Function Feature Power Button with Power LED System ID Button with ID LED 7.2 Function Toggles the system power on/off. This button also integrates the power LED. Toggles between ID LED on and off Control Panel LED Indicators The control panel houses independent two LEDs and two button integrated LEDs for each node, which are viewable to display the system’s operating status. The following table identifies each LED and describes their functionality. Table 59. Front LED Indicator Functions LED Indicator Power LAN (i350 Dual NIC) System Status Color Condition Green Green Green Green Green Green On Blink Off On Blink Off On Blink Amber On Amber Blink - Off Description Power On / ACPI S0 state Sleep / ACPI S1 state Power Off / ACPI S5 state LAN Link no Access LAN Activity No Link System Ready / No Alarm System ready, but degraded: redundancy lost such as the power supply or fan failure; non-critical temp/voltage threshold; battery failure; or predictive power supply failure. Critical Alarm: Critical power modules failure, critical fans failure, voltage (power supply), critical temperature and voltage Non-Critical Alarm: Redundant fan failure, redundant power module failure, non-critical temperature and voltage Power off: System unplugged Power on: System powered off and in standby, no prior degraded\non-critical\critical state Notes: 1. Blink rate is ~1 Hz at 50% duty cycle. 2. It is also off when the system is powered off (S5) or in a sleep state (S1). 3. The power LED sleep indication is maintained on standby by the chipset. If the system is powered down without going through the BIOS, the LED state in effect at the time of power off is restored when the system is powered on until the BIOS clears it. 4. If the system is not powered down normally, it is possible the Power LED will blink at the same time the system status LED is off due to a failure or configuration change that prevents the BIOS from running. 68 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS 7.2.1 Front Panel Control and Indicators Power/Sleep LED Table 60. Power LED Operation State Power Off Power On Power Mode Non-ACPI Non-ACPI LED Off Solid On S5 ACPI Off S1 Sleep ACPI Blink S0 ACPI Solid On Note: Blink rate is ~ 1Hz at 50% duty cycle. 7.2.2 Description System power is off and the BIOS has not initialized the chipset. System power is on but the BIOS has not yet initialized the chipset. Mechanical is off and the operating system has not saved any context to the hard disk. DC power is still on. The operating system has saved context and gone into a level of low-power state. System and the operating system are up and running. System Status LED Table 61. System Status LED Operation Color Off N/A State Criticality Not ready Description Power off or BMC initialization completes if no degraded, noncritical, critical, or non-recoverable conditions exist after power cable plug-in. Green/ Amber Both Solid On Not ready Pre DC Power On – 15-20 second BMC Initialization when AC is applied to the server. The system will not POST until BMC initialization completes. Green Solid on Ok System ready. Green Blink Degraded BIOS detected: 1. Unable to use all of the installed memory (more than one DIMM installed).1 2. In a mirrored configuration, when memory mirroring takes place and system loses memory redundancy. This is not covered by (2). 1 3. PCI Express* correctable link errors. Integrated BMC detected: 1. One of redundant power supplies not present. 2. CPU disabled – if there are two CPUs and one CPU is disabled. 3. Fan alarm – Fan failure. Number of operational fans should be more than minimum number needed to cool the system. 4. Non-critical threshold crossed – Temperature, voltage, power nozzle, power gauge, and PROCHOT2 (Therm Ctrl) sensors. 5. Battery failure. 6. Predictive failure when the system has redundant power supplies. Amber Blink Non-critical Non-fatal alarm – System is likely to fail. BIOS Detected: 1. In non-mirroring mode, if the threshold of ten correctable errors is crossed within the window.1 2. PCI Express* uncorrectable link errors. Integrated BMC Detected: 1. Critical threshold crossed – Voltage, temperature, power nozzle, power gauge, and PROCHOT (Therm Ctrl) sensors. Revision 2.2 69 Intel order number: G39462-013 Intel® Server System H2000JF Family TPS Front Panel Control and Indicators Color State Criticality 2. 3. 4. Amber Solid on Critical, nonrecoverable Description VRD Hot asserted. One of the redundant power supplies failed. Minimum number of fans to cool the system are not present or have failed. Fatal alarm – System has failed or shut down. BIOS Detected: 1. DIMM failure when there is one DIMM present and no good memory is present.1 2. Run-time memory uncorrectable error in non-redundant mode.1 3. CPU configuration error (for instance, processor stepping mismatch). Integrated BMC Detected: 1. CPU CATERR signal asserted. 2. CPU 1 is missing. 3. CPU THERMTRIP. 4. System cooling fan failure. 5. No power good – Redundant power fault. Power Unit Redundancy sensor – Insufficient resources offset (indicates not enough power supplies are present). Notes: 1. The BIOS detects these conditions and sends a Set Fault Indication command to the Integrated BMC to provide the contribution to the system status LED. 2. Blink rate is ~ 1Hz at 50% duty cycle. 7.2.3 System Status LED – BMC Initialization When power is first applied to the system and 5V-STBY is present, the BMC controller on the server board requires 15-20 seconds to initialize. During this time, the system status LED will be solid on, both amber and green. After BMC initialization has completed, the status LED will stay green solid on. If power button is pressed before BMC initialization completes, the system will not boot to POST. 70 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS 8. Configuration Jumpers Configuration Jumpers The following table provides a summary and description of configuration, test, and debug jumpers on the Intel® Server Board S2600JF, which is used in Intel® Server System H2000JF Family as Compute Node. Figure 43. Jumper Locations and Functions Revision 2.2 71 Intel order number: G39462-013 Intel® Server System H2000JF FamilyTPS Configuration Jumpers Table 62. Force Integrated BMC Update Jumper Jumper Name J6B1: BMC Force Update jumper J1E2: ME Force Update J1E3: Password Clear Jumper Position 1-2 Mode of Operation Normal Normal mode Note 2-3 Update BMC in force update mode 1-2 Normal Normal mode 2-3 Update ME in force update mode 1-2 Normal Normal mode, password in protection 2-3 Clear Password BIOS password is cleared J1E1: BIOS Recovery Mode 1-2 Normal Normal mode 2-3 Recovery BIOS in recovery mode J1D5: BIOS Default 1-2 Normal Normal mode 2-3 Clear BIOS Settings BIOS settings are reset to factory default 8.1 Force Integrated BMC Update (J6B1) When performing a standard BMC firmware update procedure, the update utility places the BMC into an update mode, allowing the firmware to load safely onto the flash device. In the unlikely event the BMC firmware update process fails due to the BMC not being in the proper update state, the server board provides a BMC Force Update jumper (J6B1) which will force the BMC into the proper update state. The following procedure should be followed in the event the standard BMC firmware update process fails. Table 63. Force Integrated BMC Update Jumper Jumper Position 1-2 2-3 Mode of Operation Normal Update Note Normal Operation BMC in force update mode Steps to perform the Force Integrated BMC Update: 1. Power down and remove the AC power cord. 2. Open the server chassis. See your server chassis documentation for instructions. 3. Move jumper from the default operating position (covering pins 1 and 2) to the enabled position (covering pins 2 and 3). 4. Close the server chassis. 5. Reconnect the AC cord and power up the server. 6. Perform the BMC firmware update procedure as documented in the ReleaseNote.TXT file included in the given BMC firmware update package. After successful completion of the firmware update process, the firmware update utility may generate an error stating the BMC is still in update mode. 7. Power down and remove the AC power cord. 8. Open the server chassis. 9. Move the jumper from the enabled position (covering pins 2 and 3) to the disabled position (covering pins 1 and 2). 10. Close the server chassis. 11. Reconnect the AC cord and power up the server. 72 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS Configuration Jumpers Note: Normal BMC functionality is disabled with the Force BMC Update jumper set to the enabled position. You should never run the server with the BMC Force Update jumper set in this position. You should only use this jumper setting when the standard firmware update process fails. This jumper should remain in the default/disabled position when the server is running normally. The server board has several 3-pin jumper blocks that can be used to configure, protect, or recover specific features of the server board. 8.2 Force ME Update (J1E2) When this 3-pin jumper is set, it manually puts the ME firmware in update mode, which enables the user to update ME firmware code when necessary. Table 64. Force ME Update Jumper Jumper Position 1-2 Mode of Operation Normal Note Normal operation 2-3 Update ME in force update mode Note: Normal ME functionality is disabled with the Force ME Update jumper set to the enabled position. You should never run the server with the ME Force Update jumper set in this position. You should only use this jumper setting when the standard firmware update process fails. This jumper should remain in the default/disabled position when the server is running normally. Steps to perform the Force ME Update: 1. Power down and remove the AC power cord. 2. Open the server chassis. For instructions, see your server chassis documentation. 3. Move jumper from the default operating position (covering pins 1 and 2) to the enabled position (covering pins 2 and 3). 4. Close the server chassis. 5. Reconnect the AC cord and power up the server. 6. Perform the ME firmware update procedure as documented in the README.TXT file that is included in the given ME firmware update package (same package as BIOS). 7. Power down and remove the AC power cord. 8. Open the server chassis. 9. Move jumper from the enabled position (covering pins 2 and 3) to the disabled position (covering pins 1 and 2). 10. Close the server chassis. 8.3 Password Clear (J1E3) This 3-pin jumper is used to clear the BIOS password. Revision 2.2 73 Intel order number: G39462-013 Intel® Server System H2000JF FamilyTPS Configuration Jumpers Table 65. BIOS Password Clear Jumper Jumper Position 1-2 2-3 Mode of Operation Normal Clear Password Note Normal mode. Password in protection BIOS password is cleared Steps to perform the password clear: 1. Power down server. Do not unplug the power cord. 2. Open the chassis. For instructions, refer to your server chassis documentation. 3. Move the jumper (J1F2) from the default operating position (covering pins 1 and 2) to the password clear position (covering pins 2 and 3). 4. Close the server chassis. 5. Power up the server, wait 10 seconds or until POST completes. 6. Power down the server. 7. Open the chassis and move the jumper back to default position (covering pins 1 and 2). 8. Close the server chassis. 9. Power up the server. The password is now cleared and you can reset it by going into the BIOS setup. The BIOS password is now cleared. 8.4 BIOS Recovery Mode (J1E1) The Intel® Server Board S2600JF uses BIOS recovery to repair the system BIOS from flash corruption in the main BIOS and Boot Block. This 3-pin jumper is used to reload the BIOS when the image is suspected to be corrupted. For directions on how to recover the BIOS, refer to the specific BIOS Release Notes. Table 66. BIOS Recovery Mode Jumper Jumper Position 1-2 2-3 Mode of Operation Normal Note Normal mode Recovery BIOS in recovery mode You can accomplish a BIOS recovery from the SATA CD and USB Mass Storage device. Note that this platform does not support recovery from a USB floppy. The recovery media must contain the following files under the root directory: 1. 2. 3. 4. RML.ROM UEFI iFlash32 11.0 Build 2 (including iFlash32.efi and ipmi.efi) *Rec.CAP Startup.nsh (update accordingly to use proper *Rec.CAP file) The BIOS starts the recovery process by first loading and booting to the recovery image file (RML.ROM) on the root directory of the recovery media (USB disk). This process takes place 74 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS Configuration Jumpers before any video or console is available. After the system boots to this recovery image file (FVMAIN.FV), it boots automatically into the EFI Shell to invoke the Startup.nsh script and start the flash update application (IFlash32.efi). IFlash32.efi requires the supporting BIOS Capsule image file (*Rec.CAP). After the update is complete, a message displays, stating the “BIOS has been updated successfully”. This indicates the recovery process is finished. The user should then switch the recovery jumper back to normal operation and restart the system by performing a power cycle. The following steps demonstrate this recovery process: 1. Power off the system. 2. Insert recovery media. 3. Switch the recovery jumper. Details regarding the jumper ID and location can be obtained from the Board EPS for that Platform. 4. Power on the system. 5. The BIOS POST screen appears displaying the progress, and the system automatically boots to the EFI SHELL. 6. The Startup.nsh file executes, and initiates the flash update (IFlash32.efi) with a new capsule file (*Rec.CAP). The regular iFlash message displays at the end of the process— after the flash update succeeds. 7. Power off the system, and revert the recovery jumper position to "normal operation". 8. Power on the system. 9. Do NOT interrupt the BIOS POST during the first boot. 8.5 Reset BIOS Settings (J1D5) This jumper is used to be the CMOS Clear jumper. The BIOS has moved CMOS data to the NVRAM region of the BIOS flash since the previous generation. The BIOS checks during boot to determine whether the data in the NVRAM must be set to default. Table 67. Reset BIOS Jumper Jumper Position 1-2 Mode of Operation Normal 2-3 Reset BIOS Configuration Note These pins should have a jumper in place for normal system operation (Default). If these pins 2-3 are connected with AC power plugged, the CMOS settings are cleared within five seconds. These pins should not be connected for normal operation. Steps to reset the BIOS settings to default: 1. Power down server. Do not unplug the power cord. 2. Open the server chassis. For instructions, see your server chassis documentation. Revision 2.2 75 Intel order number: G39462-013 Configuration Jumpers Intel® Server System H2000JF FamilyTPS 3. Move jumper (J1D5) from the default operating position (covering pins 1 and 2) to the reset/clear position (covering pins 2 and 3). 4. Wait five seconds. 5. Remove AC power. 6. Move the jumper back to default position (covering pins 1 and 2). 7. Close the server chassis. 8. Power up the server. The BIOS settings are now cleared and you can reset it by going into the BIOS setup. Note: Removing AC Power before performing the BIOS settings Clear operation causes the system to automatically power up and immediately power down, after the procedure is followed and AC power is re-applied. If this happens, remove the AC power cord again, wait 30 seconds, and re-install the AC power cord. Power-up the system and proceed to the <F2> BIOS Setup Utility to reset the desired settings. 76 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS 9. PCI Express* Riser Card and Assembly PCI Express* Riser Card and Assembly Each compute node in Intel® Server System H2000JF Family includes three PCI Express* riser slots that accepts dedicated PCI Express* x16 Gen3 Risers to support low profile add-in card and Intel® IO module. Only Riser Slot 1 and Riser Slot 2 are available for risers. Riser Slot 3 is hidden by bridge board. The PCI Express* slot on riser also accommodates PCI Express* x8, x4, and x1 adapters. 9.1 PCI Express* Riser for Slot 1 9.1.1 Overview of PCI-Express* Riser Riser slot 1 on baseboard provides standard PCI Express* x16 Gen3 signals, together with specific power pins to support high-power double width graphic add-in card. Note: Riser Slot 1 on baseboard only supports Intel® 1U/2U Risers. It will cause damage to any PCI-E based add-in card, which is directly plugged into the Riser Slot 1 on baseboard. Figure 44. PCI Express* Riser for Riser Slot 1 9.1.2 Pin-out Definition on Slot 1 Riser The following table is a list of pin definition on Slot 1 Riser. Table 68. Riser Card Edge Pin-out Pin Pin Name Description Pin Pin Name Description B1 12V 20W 3.3V generated on riser A1 12V 20W 3.3V generated on riser B2 12V 66W for double width add-in card A2 12V 66W for double width add-in card B3 12V 66W for double width add-in card A3 12V 66W for double width add-in card B4 12V 66W for double width add-in card A4 SMDATA Revision 2.2 77 Intel order number: G39462-013 Intel® Server System H2000JF FamilyTPS PCI Express* Riser Card and Assembly Pin B5 Pin Name Description SMCLK B6 Pin A5 For wake on LAN Pin Name 3.3VAUX For wake on LAN GPU_NODE_ON Turn on double width card power A6 3.3VAUX Description B7 GND A7 GPU_PWRGD B8 Tach9 A8 Tach11 B9 Tach8 A9 Tach10 B10 Tach7 A10 Tach6 B11 Spare A11 Spare KEY B12 A12 Spare PWM2 Double width card fan speed control B13 Spare A13 GND B14 GND A14 PERST# B15 SMBUS_R4 CLK A15 WAKE# B16 SMBUS_R4 DAT A16 GND B17 GND A17 REFCLK+ Clock pair 1 B18 PETxP0 Tx Lane 0+ A18 REFCLK- Clock pair 1 B19 PETxN0 Tx Lane 0- A19 GND B20 GND A20 PERxP0 Rx Lane 0+ B21 GND A21 PERxN0 Rx Lane 0- B22 PETxP1 Tx Lane 1+ A22 GND B23 PETxN1 Tx Lane 1- A23 GND B24 GND A24 PERxP1 Rx Lane 1+ B25 GND A25 PERxN1 Rx Lane 1- B26 PETxP2 Tx Lane 2+ A26 GND B27 PETxN2 Tx Lane 2- A27 GND B28 GND A28 PERxP2 Rx Lane 2+ B29 GND A29 PERxN2 Rx Lane 2- B30 PETxP3 Tx Lane 3+ A30 GND B31 PETxN3 Tx Lane 3- A31 GND B32 GND A32 PERxP3 Rx Lane 3+ B33 GND A33 PERxN3 Rx Lane 3- B34 PETxP4 Tx Lane 4+ A34 GND B35 PETxN4 Tx Lane 4- A35 GND B36 GND A36 PERxP4 Rx Lane 4+ B37 GND A37 PERxN4 Rx Lane 4- B38 PETxP5 Tx Lane 5+ A38 GND B39 PETxN5 Tx Lane 5- A39 GND B40 GND A40 PERxP5 Rx Lane 5+ B41 GND A41 PERxN5 Rx Lane 5- B42 PETxP6 A42 GND 78 Tx Lane 6+ Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS Pin Pin Name Description Tx Lane 6- PCI Express* Riser Card and Assembly Pin Pin Name Description B43 PETxN6 A43 GND B44 GND A44 PERxP6 Rx Lane 6+ B45 GND A45 PERxN6 Rx Lane 6- B46 PETxP7 Tx Lane 7+ A46 GND B47 PETxN7 Tx Lane 7- A47 GND B48 GND A48 PERxP7 Rx Lane 7+ B49 GND A49 PERxN7 Rx Lane 7- B50 PETxP8 Tx Lane 8+ A50 GND B51 PETxN8 Tx Lane 8- A51 GND B52 GND A52 PERxP8 Rx Lane 8+ B53 GND A53 PERxN8 Rx Lane 8- B54 PETxP9 Tx Lane 9+ A54 GND B55 PETxN9 Tx Lane 9- A55 GND B56 GND A56 PERxP9 Rx Lane 9+ B57 GND A57 PERxN9 Rx Lane 9- B58 PETxP10 Tx Lane 10+ A58 GND B59 PETxN10 Tx Lane 10- A59 GND B60 GND A60 PERxP10 Rx Lane 10+ B61 GND A61 PERxN10 Rx Lane 10- B62 PETxP11 Tx Lane 11+ A62 GND B63 PETxN11 Tx Lane 11- A63 GND B64 GND A64 PERxP11 Rx Lane 11+ B65 GND A65 PERxN11 Rx Lane 11- B66 PETxP12 Tx Lane 12+ A66 GND B67 PETxN12 Tx Lane 12- A67 GND B68 GND A68 PERxP12 Rx Lane 12+ B69 GND A69 PERxN12 Rx Lane 12- B70 PETxP13 Tx Lane 13+ A70 GND B71 PETxN13 Tx Lane 13- A71 GND B72 GND A72 PERxP13 Rx Lane 13+ B73 GND A73 PERxN13 Rx Lane 13- B74 PETxP14 Tx Lane 14+ A74 GND B75 PETxN14 Tx Lane 14- A75 GND B76 GND A76 PERxP14 Rx Lane 14+ B77 REFCLK+ Clock pair 2 A77 PERxN14 Rx Lane 14- B78 REFCLK- Clock pair 2 A78 GND B79 GND A79 PERxP15 Rx Lane 15+ B80 PETxP15 Tx Lane 15+ A80 PERxN15 Rx Lane 15- B81 PETxN15 Tx Lane 15- A81 GND B82 GND A82 Riser ID Revision 2.2 Fix to High: PCIe x16 79 Intel order number: G39462-013 Intel® Server System H2000JF FamilyTPS PCI Express* Riser Card and Assembly There is a standard PCI Express* Gen3 x16 slot on riser card for PCI-E* based add-in card. The pin definition for the slot is as below. Table 69. PCI Express* Slot Pin-out on Riser Card Pin-Side B 82 80 PCI Spec Signal RSVD Pin-Side A 82 PCI Spec Signal GND 81 PRSNT2# 81 HSIN15 80 GND 80 HSIP15 79 HSON15 79 GND 78 HSOP15 78 GND 77 GND 77 HSIN14 76 GND 76 HSIP14 75 HSON14 75 GND 74 HSOP14 74 GND 73 GND 73 HSIN13 72 GND 72 HSIP13 71 HSON13 71 GND 70 HSOP13 70 GND 69 GND 69 HSIN12 68 GND 68 HSIP12 67 HSON12 67 GND 66 HSOP12 66 GND 65 GND 65 HSIN11 64 GND 64 HSIP11 63 HSON11 63 GND 62 HSOP11 62 GND 61 GND 61 HSIN10 60 GND 60 HSIP10 59 HSON10 59 GND 58 HSOP10 58 GND 57 GND 57 HSIN9 56 GND 56 HSIP9 55 HSON9 55 GND 54 HSOP9 54 GND 53 GND 53 HSIN8 52 GND 52 HSIP8 51 HSON8 51 GND 50 HSOP8 50 RSVD 49 GND 49 GND 48 PRSNT2# 48 HSIN7 47 GND 47 HSIP7 46 HSON7 46 GND 45 HSOP7 45 GND 44 GND 44 HSIN6 43 GND 43 HSIP6 42 HSON6 42 GND Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS Pin-Side B 41 PCI Spec Signal HSOP6 PCI Express* Riser Card and Assembly Pin-Side A 41 PCI Spec Signal GND 40 GND 40 HSIN5 39 GND 39 HSIP5 38 HSON5 38 GND 37 HSOP5 37 GND 36 GND 36 HSIN4 35 GND 35 HSIP4 34 HSON4 34 GND 33 HSOP4 33 RSVD 32 GND 32 RSVD 31 PRSNT2# 31 GND 30 RSVD 30 HSIN3 29 GND 29 HSIP3 28 HSON3 28 GND 27 HSOP3 27 GND 26 GND 26 HSIN2 25 GND 25 HSIP2 24 HSON2 24 GND 23 HSOP2 23 GND 22 GND 22 HSIN1 21 GND 21 HSIP1 20 HSON1 20 GND 19 HSOP1 19 RSVD 18 GND 18 GND 17 PRSNT2# 17 HSIN0 16 GND 16 HSIP0 15 HSON0 15 GND 14 HSOP0 14 REFCLK- 13 GND 13 REFCLK+ 12 RSVD 12 GND KEY KEY KEY KEY 11 WAKE# 11 PWRGD 10 3.3V AUX 10 3.3V 9 JTAG1 9 3.3V 8 3.3V 8 JTAG5 7 GND 7 JTAG4 6 SMDAT 6 JTAG3 5 SMCLK 5 JTAG2 4 GND 4 GND 3 RSVD 3 12V 2 12V 2 12V 1 12V 1 PRSNT1# Revision 2.2 81 Intel order number: G39462-013 PCI Express* Riser Card and Assembly 9.2 9.2.1 Intel® Server System H2000JF FamilyTPS PCI Express* Riser with IOM Carrier for Slot 2 (Optional) Overview of PCI-E* Riser with IOM Carrier The Riser with IOM carrier is provided as accessory to the server system. It is combined with below functions: Provide PCI Express* x8 Gen 3 signals from riser Integrated 1GbE management port for Intel® Remote Management Module 4 Support PCI-E* x8 based Intel® IO Module Riser slot 2 on baseboard provides standard PCI Express* x16 Gen3 signals, together with specific power pins to support high-power double width Graphic add-in card. Note: Riser Slot 2 on baseboard only supports Intel® 1U/2U Risers. It will cause damage to any PCI-E* based add-in card, which is directly plugged into the Riser Slot 1. The PCI-E* slot on Riser is x16 mechanically with x8 electrically. The IOM carrier is using PCIE* x8 card edge with PCI-E* x8 IO module slot. Figure 45. PCI Express* Riser with Bracket for Riser Slot 2 Figure 46. IOM Carrier 82 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS PCI Express* Riser Card and Assembly The 1GbE port is dedicated NIC port for RMM4 Lite module. It only works after the RMM4 Lite module is installed in the system. The LED of dedicated NIC port is following the definition below. Table 70. Dedicated NIC Port LED Functionality LED Color Green Condition On Functionality 1Gbps mode Dedicated NIC Speed Amber On 100Mbps mode Off 10Mbps mode Green On LAN link and no access Green Blink LAN access Off Idle Dedicated NIC Activity 9.2.2 Pin-out Definition on Slot 2 Riser and IOM Carrier Following is a list of pin definition for Slot 2 Riser and IOM Carrier. Table 71. Riser Card Edge Pin-out Pin Pin Name Description Pin Pin Name Description B1 12V 20W 3.3V generated on riser A1 12V 20W 3.3V generated on riser B2 12V 66W for double width add-in card A2 12V 66W for double width add-in card B3 12V 66W for double width add-in card A3 12V 66W for double width add-in card B4 12V 66W for double width add-in card A4 SMDATA For rIOM temp sensor B5 SMCLK for rIOM temp sensor A5 5VAUX For DNM and IOM wake on LAN PRESENT# DNM function present B6 3.3V Aux B7 GND B8 TXD_0 B9 TXD_1 B10 For DNM and IOM wake on LAN A6 A7 RIOM_ACT# RGMII txmit data A8 RXD_3 RGMII receive data RGMII txmit data A9 RXD_2 RGMII receive data TXD_2 RGMII txmit data A10 RXD_1 RGMII receive data B11 TXD_3 RGMII txmit data A11 KEY RXD_0 RGMII receive data B12 GND A12 RX_CTL RGMII receive Cntrl B13 TX_CLK RGMII txmit Clock A13 GND B14 TX_CTL RGMII txmit Cntrl A14 RX_CLK B15 MDIO A15 MDC B16 PERST# A16 GND B17 WAKE# A17 REFCLK+ Clock pair 1 B18 PETxP0 Tx Lane 0+ A18 REFCLK- Clock pair 1 B19 PETxN0 Tx Lane 0- A19 GND Revision 2.2 RGMII receive Clock 83 Intel order number: G39462-013 Intel® Server System H2000JF FamilyTPS PCI Express* Riser Card and Assembly Pin Pin Name Description Pin Pin Name Description B20 GND A20 PERxP0 Rx Lane 0+ B21 GND A21 PERxN0 Rx Lane 0- B22 PETxP1 Tx Lane 1+ A22 GND B23 PETxN1 Tx Lane 1- A23 GND B24 GND A24 PERxP1 Rx Lane 1+ B25 GND A25 PERxN1 Rx Lane 1- B26 PETxP2 Tx Lane 2+ A26 GND B27 PETxN2 Tx Lane 2- A27 GND B28 GND A28 PERxP2 Rx Lane 2+ B29 GND A29 PERxN2 Rx Lane 2- B30 PETxP3 Tx Lane 3+ A30 GND B31 PETxN3 Tx Lane 3- A31 GND B32 GND A32 PERxP3 Rx Lane 3+ B33 GND A33 PERxN3 Rx Lane 3- B34 PETxP4 Tx Lane 4+ A34 GND B35 PETxN4 Tx Lane 4- A35 GND B36 GND A36 PERxP4 Rx Lane 4+ B37 GND A37 PERxN4 Rx Lane 4- B38 PETxP5 Tx Lane 5+ A38 GND B39 PETxN5 Tx Lane 5- A39 GND B40 GND A40 PERxP5 Rx Lane 5+ B41 GND A41 PERxN5 Rx Lane 5- B42 PETxP6 Tx Lane 6+ A42 GND B43 PETxN6 Tx Lane 6- A43 GND B44 GND A44 PERxP6 Rx Lane 6+ B45 GND A45 PERxN6 Rx Lane 6- B46 PETxP7 Tx Lane 7+ A46 GND B47 PETxN7 Tx Lane 7- A47 GND B48 GND A48 PERxP7 Rx Lane 7+ B49 GND A49 PERxN7 Rx Lane 7- B50 PETxP8 Tx Lane 8+ A50 GND B51 PETxN8 Tx Lane 8- A51 GND B52 GND A52 PERxP8 Rx Lane 8+ B53 GND A53 PERxN8 Rx Lane 8- B54 PETxP9 Tx Lane 9+ A54 GND B55 PETxN9 Tx Lane 9- A55 GND B56 GND A56 PERxP9 Rx Lane 9+ B57 GND A57 PERxN9 Rx Lane 9- B58 PETxP10 Tx Lane 10+ A58 GND B59 PETxN10 Tx Lane 10- A59 GND B60 GND A60 PERxP10 Rx Lane 10+ B61 GND A61 PERxN10 Rx Lane 10- 84 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS Description PCI Express* Riser Card and Assembly Pin Pin Name Pin Pin Name Description B62 PETxP11 Tx Lane 11+ A62 GND B63 PETxN11 Tx Lane 11- A63 GND B64 GND A64 PERxP11 Rx Lane 11+ B65 GND A65 PERxN11 Rx Lane 11- B66 PETxP12 Tx Lane 12+ A66 GND B67 PETxN12 Tx Lane 12- A67 GND B68 GND A68 PERxP12 Rx Lane 12+ B69 GND A69 PERxN12 Rx Lane 12- B70 PETxP13 Tx Lane 13+ A70 GND B71 PETxN13 Tx Lane 13- A71 GND B72 GND A72 PERxP13 Rx Lane 13+ B73 GND A73 PERxN13 Rx Lane 13- B74 PETxP14 Tx Lane 14+ A74 GND B75 PETxN14 Tx Lane 14- A75 GND B76 GND A76 PERxP14 Rx Lane 14+ B77 REFCLK+ Clock pair 2 A77 PERxN14 Rx Lane 14- B78 REFCLK- Clock pair 2 A78 GND B79 GND A79 PERxP15 Rx Lane 15+ B80 PETxP15 Tx Lane 15+ A80 PERxN15 Rx Lane 15- B81 PETxN15 Tx Lane 15- A81 GND B82 GND A82 Riser ID Fix to Low: PCIe 2x8 Table 72 PCI Express* Slot Pin-out on Riser Card Pin-Side B 82 PCI Spec Signal RSVD Pin-Side A 82 PCI Spec Signal GND 81 PRSNT2# 81 HSIN15 80 GND 80 HSIP15 79 HSON15 79 GND 78 HSOP15 78 GND 77 GND 77 HSIN14 76 GND 76 HSIP14 75 HSON14 75 GND 74 HSOP14 74 GND 73 GND 73 HSIN13 72 GND 72 HSIP13 71 HSON13 71 GND 70 HSOP13 70 GND 69 GND 69 HSIN12 68 GND 68 HSIP12 67 HSON12 67 GND 66 HSOP12 66 GND 65 GND 65 HSIN11 64 GND 64 HSIP11 Revision 2.2 85 Intel order number: G39462-013 Intel® Server System H2000JF FamilyTPS PCI Express* Riser Card and Assembly Pin-Side B 63 86 PCI Spec Signal HSON11 Pin-Side A 63 GND PCI Spec Signal 62 HSOP11 62 GND 61 GND 61 HSIN10 60 GND 60 HSIP10 59 HSON10 59 GND 58 HSOP10 58 GND 57 GND 57 HSIN9 56 GND 56 HSIP9 55 HSON9 55 GND 54 HSOP9 54 GND 53 GND 53 HSIN8 52 GND 52 HSIP8 51 HSON8 51 GND 50 HSOP8 50 RSVD 49 GND 49 GND 48 PRSNT2# 48 HSIN7 47 GND 47 HSIP7 46 HSON7 46 GND 45 HSOP7 45 GND 44 GND 44 HSIN6 43 GND 43 HSIP6 42 HSON6 42 GND 41 HSOP6 41 GND 40 GND 40 HSIN5 39 GND 39 HSIP5 38 HSON5 38 GND 37 HSOP5 37 GND 36 GND 36 HSIN4 35 GND 35 HSIP4 34 HSON4 34 GND 33 HSOP4 33 RSVD 32 GND 32 RSVD 31 PRSNT2# 31 GND 30 RSVD 30 HSIN3 29 GND 29 HSIP3 28 HSON3 28 GND 27 HSOP3 27 GND 26 GND 26 HSIN2 25 GND 25 HSIP2 24 HSON2 24 GND 23 HSOP2 23 GND 22 GND 22 HSIN1 21 GND 21 HSIP1 20 HSON1 20 GND 19 HSOP1 19 RSVD Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS Pin-Side B 18 PCI Spec Signal GND PCI Express* Riser Card and Assembly Pin-Side A 18 PCI Spec Signal GND 17 PRSNT2# 17 HSIN0 16 GND 16 HSIP0 15 HSON0 15 GND 14 HSOP0 14 REFCLK- 13 GND 13 REFCLK+ 12 RSVD 12 GND KEY KEY KEY KEY 11 WAKE# 11 PWRGD 10 3.3V AUX 10 3.3V 9 JTAG1 9 3.3V 8 3.3V 8 JTAG5 7 GND 7 JTAG4 6 SMDAT 6 JTAG3 5 SMCLK 5 JTAG2 4 GND 4 GND 3 RSVD 3 12V 2 12V 2 12V 1 12V 1 PRSNT1# Table 73. IO Module Slot on Carrier Pin Signal Signal Pin 1 3.3V 12V 2 3 3.3V 12V 4 5 3.3V 12V 6 7 3.3V 12V 8 9 RSVD FRU/TEMP ADDR [I] 10 11 GND 5VSB 12 13 RSVD+ FM_IO_MODULE_EN 14 15 RSVD- 3.3VSTBY 16 17 GND LED_GLOBAL ACT# 18 19 RSVD FM_IOM_PRESENT_N 20 21 RSVD WAKE# 22 23 GND PERST# 24 25 SMB CLK GND 26 27 SMB DAT rIOM REFCLK+ [0] 28 29 GND rIOM REFCLK- [0] 30 31 PCIe Gen3 Tn [7]] GND 32 33 PCIe Gen3 Tp [7] PCIe Gen3 Rn [7] 34 Revision 2.2 87 Intel order number: G39462-013 PCI Express* Riser Card and Assembly 88 Intel® Server System H2000JF FamilyTPS Pin Signal Signal Pin 35 GND PCIe Gen3 Rp [7] 36 37 PCIe Gen3 Tn [6] GND 38 39 PCIe Gen3 Tp [6] PCIe Gen3 Rn [6] 40 41 GND PCIe Gen3 Rp [6] 42 43 PCIe Gen3 Tn [5] GND 44 45 PCIe Gen3 Tp [5] PCIe Gen3 Rn [5] 46 47 GND PCIe Gen3 Rp [5] 48 49 PCIe Gen3 Tn [4] GND 50 51 PCIe Gen3 Tp [4] PCIe Gen3 Rn [4] 52 53 GND PCIe Gen3 Rp [4] 54 55 PCIe Gen3 Tn [3] GND 56 57 PCIe Gen3 Tp [3] PCIe Gen3 Rn [3] 58 59 GND PCIe Gen3 Rp [3] 60 61 PCIe Gen3 Tn [2] GND 62 63 PCIe Gen3 Tp [2] PCIe Gen3 Rn [2] 64 65 GND PCIe Gen3 Rp [2] 66 67 PCIe Gen3 Tn [1] GND 68 69 PCIe Gen3 Tp [1] PCIe Gen3 Rn [1] 70 71 GND PCIe Gen3 Rp [1] 72 73 PCIe Gen3 Tn [0] GND 74 75 PCIe Gen3 Tp [0] PCIe Gen3 Rn [0] 76 77 GND PCIe Gen3 Rp [0] 78 79 RSVD GND 80 Intel order number: G39462-013 Revision 2.2 Appendix A: Integration and Usage Tips Intel® Server System H2000JF Family TPS Appendix A: Integration and Usage Tips Before attempting to integrate and configure your system, you should reference this section, which provides a list of useful information. After the system is integrated with processors, memory, and peripheral devices, the FRUSDR utility must be run to load the proper Sensor Data Record data to the integrated Server Management subsystem. Failure to run this utility may prevent Server Management from accurately monitoring system health and may affect system performance. The FRUSDR utility for this server system can either be run from the Intel® Deployment CDROM that came with your system, or can be downloaded from the Intel website referenced at the bottom of this page. To ensure the highest system reliability, make sure the latest system software is loaded on the server before deploying the system onto a live networking environment. This includes system BIOS, FRUSDR, BMC firmware, and hot-swap controller firmware. The system software can be updated using the Intel® Deployment CDROM that came with your system or can be downloaded from the Intel website referenced at the bottom of this page. System fans are not hot-swappable. Only supported memory validated by Intel should be used in this server system. A list of supported memory can be found in the Intel® Server Board S2600JF Tested Memory List which can be downloaded from the Intel website referenced at the bottom of this page. This system supports the Intel® Xeon® processor E5-2600 and E5-2600V2 sequence. You cannot use Intel® Xeon® processors not referenced on the supported processor list in this server system. You must use the CPU/memory air duct to maintain system thermals. To maintain system thermals, you must populate all hard drive bays with either a hard drive or drive blank. You must remove AC power from the system prior to opening the chassis for service You can download the latest system documentation, drivers, and system software from the Intel® Support website at http://www.intel.com/p/en_US/support/highlights/server/ss-h2000jf. Revision 2.2 89 Intel order number: G39462-013 Intel® Server System H2000JF Family TPS Appendix B: POST Code LED Decoder Appendix B: POST Code LED Decoder During the system boot process, the BIOS executes a number of platform configuration processes, each of which is assigned a specific hex POST code number. As each configuration routine is started, the BIOS displays the POST code to the POST Code Diagnostic LEDs on the back edge of the server board. To assist in troubleshooting a system hang during the POST process, you can use the diagnostic LEDs to identify the last POST process executed. Figure 47. Diagnostic LED Location Table 74. POST Code Diagnostic LED Location 90 A ID LED B Status LED C Diagnostic LED #7 MSB G Diagnostic LED #3 D Diagnostic LED #6 H Diagnostic LED #2 E Diagnostic LED #5 I Diagnostic LED #1 F Diagnostic LED #4 J Diagnostic LED #0 LSB Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS Appendix B: POST Code LED Decoder Each POST code is represented by the eight amber diagnostic LEDs. The POST codes are divided into two nibbles, an upper nibble and a lower nibble. The upper nibble bits are represented by diagnostic LEDs #4, #5, #6, and #7. The lower nibble bits are represented by diagnostics LEDs #0, #1, #2, and #3. If the bit is set in the upper and lower nibbles, the corresponding LED is lit. If the bit is clear, the corresponding LED is off. The diagnostic LED #7 is labeled as “MSB” (Most Significant Bit), and the diagnostic LED #0 is labeled as “LSB” (Least Significant Bit). In the following example, the BIOS sends a value of ACh to the diagnostic LED decoder. The LEDs are decoded as follows. Table 75. POST Progress Code LED Example Upper Nibble LEDs LEDs Status Results MSB LED #7 8h ON 1 LED #6 4h OFF 0 LED #5 2h ON 1 Lower Nibble LEDs LED #4 1h OFF 0 LED #3 8h ON 1 LED #2 4h ON 1 LED #1 2h OFF 0 LSB LED #0 1h OFF 0 Ah Ch Upper nibble bits = 1010b = Ah; Lower nibble bits = 1100b = Ch; the two are concatenated as ACh. Table 76. Diagnostic LED POST Code Decoder Progress Code Description SEC Phase 0x01 First POST code after CPU reset 0x02 Microcode load begin 0x03 CRAM initialization begin 0x04 Pei Cache When Disabled 0x05 SEC Core At Power On Begin 0x06 Early CPU initialization during Sec Phase 0x07 Early SB initialization during Sec Phase 0x08 Early NB initialization during Sec Phase 0x09 End Of Sec Phase 0x0E Microcode Not Found 0x0F Microcode Not Loaded PEI Phase 0x10 PEI Core 0x11 CPU PEIM Revision 2.2 91 Intel order number: G39462-013 Intel® Server System H2000JF Family TPS Appendix B: POST Code LED Decoder Progress Code Description 0x15 NB PEIM 0x19 SB PEIM MRC Progress Codes At this point the MRC Progress Code sequence is executed 0x31 Memory Installed 0x32 CPU PEIM (CPU Init) 0x33 CPU PEIM (Cache Init) 0x34 CPU PEIM (BSP Select) 0x35 CPU PEIM (AP Init) 0x36 CPU PEIM (CPU SMM Init) 0x4F Dxe IPL started DXE Phase 92 0x60 DXE Core started 0x61 DXE NVRAM Init 0x62 SB RUN Init 0x63 DXE CPU Init 0x68 DXE PCI Host Bridge Init 0x69 DXE NB Init 0x6A DXE NB SMM Init 0x70 DXE SB Init 0x71 DXE SB SMM Init 0x72 DXE SB devices Init 0x78 DXE ACPI Init 0x79 DXE CSM Init 0x90 DXE BDS Started 0x91 DXE BDS connect drivers 0x92 DXE PCI Bus begin 0x93 DXE PCI Bus HPC Init 0x94 DXE PCI Bus enumeration 0x95 DXE PCI Bus resource requested 0x96 DXE PCI Bus assign resource Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS Appendix B: POST Code LED Decoder Progress Code Description 0x97 DXE CON_OUT connect 0x98 DXE CON_IN connect 0x99 DXE SIO Init 0x9A DXE USB start 0x9B DXE USB reset 0x9C DXE USB detect 0x9D DXE USB enable 0xA1 DXE IDE begin 0xA2 DXE IDE reset 0xA3 DXE IDE detect 0xA4 DXE IDE enable 0xA5 DXE SCSI begin 0xA6 DXE SCSI reset 0xA7 DXE SCSI detect 0xA8 DXE SCSI enable 0xA9 DXE verifying SETUP password 0xAB DXE SETUP start 0xAC DXE SETUP input wait 0xAD DXE Ready to Boot 0xAE DXE Legacy Boot 0xAF DXE Exit Boot Services 0xB0 RT Set Virtual Address Map Begin 0xB1 RT Set Virtual Address Map End 0xB2 DXE Legacy Option ROM init 0xB3 DXE Reset system 0xB4 DXE USB Hot plug 0xB5 DXE PCI BUS Hot plug 0xB6 DXE NVRAM cleanup 0xB7 DXE Configuration Reset 0x00 INT19 Revision 2.2 93 Intel order number: G39462-013 Intel® Server System H2000JF Family TPS Appendix B: POST Code LED Decoder Progress Code Description S3 Resume 0xE0 S3 Resume PEIM (S3 started) 0xE1 S3 Resume PEIM (S3 boot script) 0xE2 S3 Resume PEIM (S3 Video Repost) 0xE3 S3 Resume PEIM (S3 OS wake) BIOS Recovery 94 0xF0 PEIM which detected forced Recovery condition 0xF1 PEIM which detected User Recovery condition 0xF2 Recovery PEIM (Recovery started) 0xF3 Recovery PEIM (Capsule found) 0xF4 Recovery PEIM (Capsule loaded) Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS Appendix C: Video POST Code Errors Appendix C: Video POST Code Errors Whenever possible, the BIOS outputs the current boot progress codes on the video screen. Progress codes are 32-bit quantities plus optional data. The 32-bit numbers include class, subclass, and operation information. The class and subclass fields point to the type of hardware being initialized. The operation field represents the specific initialization activity. Based on the data bit availability to display progress codes, a progress code can be customized to fit the data width. The higher the data bit, the higher the granularity of information that can be sent on the progress port. The progress codes may be reported by the system BIOS or option ROMs. The Response section in the following table indicates one of these actions: Minor: The message is displayed on the screen or on the Error Manager screen, and an error is logged to the SEL. The system continues booting in a degraded state. The user may want to replace the erroneous unit. The POST Error Pause option setting in the BIOS setup does not have any effect on this error. Major: The message is displayed on the Error Manager screen, and an error is logged to the SEL. The POST Error Pause option setting in the BIOS setup determines whether the system pauses to the Error Manager for this type of error so the user can take immediate corrective action or the system continues booting. Note that for 0048 “Password check failed”, the system halts, and then after the next reset/reboot will displays the error code on the Error Manager screen. Fatal: The system halts during post at a blank screen with the text “Unrecoverable fatal error found. System will not boot until the error is resolved” and “Press <F2> to enter setup” The POST Error Pause option setting in the BIOS setup does not have any effect with this class of error. When the operator presses the F2 key on the keyboard, the error message is displayed on the Error Manager screen, and an error is logged to the SEL with the error code. The system cannot boot unless the error is resolved. The user needs to replace the faulty part and restart the system. Again, note that these Error Codes and the messages that go with them must be coordinated with the master list maintained by the Server Management Utilities team. Be aware that the POST Error Code list shown in this table may contain error codes which do not necessarily apply uniformly to every platform. Only a subset of these error codes will be applicable to any given server board. Table 77. POST Error Message and Message Error Code 0012 System RTC date/time not set Response Major 0048 Password check failed Major 113 Fixed media not detected Major 0140 PCI component encountered a PERR error Major 0141 PCI resource conflict Major 0146 PCI out of resources error Major Revision 2.2 Error Message Intel order number: G39462-013 95 Appendix C: Video POST Code Errors Intel® Server System H2000JF Family TPS Error Code 0191 Error Message Processor core/thread count mismatch detected Response Fatal 0192 Processor cache size mismatch detected Fatal 0194 Processor family mismatch detected Fatal 0195 Processor Intel(R) QPI link frequencies unable to synchronize Fatal 0196 Processor model mismatch detected Fatal 0197 Processor frequencies unable to synchronize Fatal 5220 BIOS Settings reset to default settings Major 5221 Passwords cleared by jumper Major 5224 Password clear jumper is Set Major 8130 Processor 01 disabled Major 8131 Processor 02 disabled Major 8132 Processor 03 disabled Major 8133 Processor 04 disabled Major 8160 Processor 01 unable to apply microcode update Major 8161 Processor 02 unable to apply microcode update Major 8162 Processor 03 unable to apply microcode update Major 8163 Processor 04 unable to apply microcode update Major 8170 Processor 01 failed Self Test (BIST) Major 8171 Processor 02 failed Self Test (BIST) Major 8172 Processor 03 failed Self Test (BIST) Major 8173 Processor 04 failed Self Test (BIST) Major 8180 Processor 01 microcode update not found Minor 8181 Processor 02 microcode update not found Minor 8182 Processor 03 microcode update not found Minor 8183 Processor 04 microcode update not found Minor 8190 Watchdog timer failed on last boot Major 8198 OS boot watchdog timer failure Major 8300 Baseboard management controller failed self test Major 8305 Hot Swap Controller failure Major 83A0 Management Engine (ME) failed self test Major 83A1 Management Engine (ME) Failed to respond. Major 84F2 Baseboard management controller failed to respond Major 84F3 Baseboard management controller in update mode Major 84F4 Sensor data record empty Major 84FF System event log full Minor 8500 Memory component could not be configured in the selected RAS mode Major 8501 DIMM Population Error Major 8520 DIMM_A1 failed test/initialization Major 8521 DIMM_A2 failed test/initialization Major 8522 DIMM_A3 failed test/initialization Major 8523 DIMM_B1 failed test/initialization Major 8524 DIMM_B2 failed test/initialization Major 8525 DIMM_B3 failed test/initialization Major 8526 DIMM_C1 failed test/initialization Major 8527 DIMM_C2 failed test/initialization Major 96 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS Appendix C: Video POST Code Errors Error Code 8528 DIMM_C3 failed test/initialization Response Major 8529 DIMM_D1 failed test/initialization Major 852A DIMM_D2 failed test/initialization Major 852B DIMM_D3 failed test/initialization Major 852C DIMM_E1 failed test/initialization Major 852D DIMM_E2 failed test/initialization Major 852E DIMM_E3 failed test/initialization Major 852F DIMM_F1 failed test/initialization Major 8530 DIMM_F2 failed test/initialization Major 8531 DIMM_F3 failed test/initialization Major 8532 DIMM_G1 failed test/initialization Major 8533 DIMM_G2 failed test/initialization Major 8534 DIMM_G3 failed test/initialization Major 8535 DIMM_H1 failed test/initialization Major 8536 DIMM_H2 failed test/initialization Major 8537 DIMM_H3 failed test/initialization Major 8538 DIMM_J1 failed test/initialization Major 8539 DIMM_J2 failed test/initialization Major 853A DIMM_J3 failed test/initialization Major 853B DIMM_K1 failed test/initialization Major 853C DIMM_K2 failed test/initialization Major 853D DIMM_K3 failed test/initialization Major 853E DIMM_L1 failed test/initialization Major 853F (Go to 85C0) DIMM_L2 failed test/initialization Major 8540 DIMM_A1 disabled Major 8541 DIMM_A2 disabled Major 8542 DIMM_A3 disabled Major 8543 DIMM_B1 disabled Major 8544 DIMM_B2 disabled Major 8545 DIMM_B3 disabled Major 8546 DIMM_C1 disabled Major 8547 DIMM_C2 disabled Major 8548 DIMM_C3 disabled Major 8549 DIMM_D1 disabled Major 854A DIMM_D2 disabled Major 854B DIMM_D3 disabled Major 854C DIMM_E1 disabled Major 854D DIMM_E2 disabled Major 854E DIMM_E3 disabled Major 854F DIMM_F1 disabled Major 8550 DIMM_F2 disabled Major 8551 DIMM_F3 disabled Major 8552 DIMM_G1 disabled Major Revision 2.2 Error Message Intel order number: G39462-013 97 Intel® Server System H2000JF Family TPS Appendix C: Video POST Code Errors Error Code 8553 DIMM_G2 disabled Response Major 8554 DIMM_G3 disabled Major 8555 DIMM_H1 disabled Major 8556 DIMM_H2 disabled Major 8557 DIMM_H3 disabled Major 8558 DIMM_J1 disabled Major 8559 DIMM_J2 disabled Major 855A DIMM_J3 disabled Major 855B DIMM_K1 disabled Major 855C DIMM_K2 disabled Major 855D DIMM_K3 disabled Major 855E DIMM_L1 disabled Major 855F (Go to 85D0) DIMM_L2 disabled Major 8560 DIMM_A1 encountered a Serial Presence Detection (SPD) failure Major 8561 DIMM_A2 encountered a Serial Presence Detection (SPD) failure Major 8562 DIMM_A3 encountered a Serial Presence Detection (SPD) failure Major 8563 DIMM_B1 encountered a Serial Presence Detection (SPD) failure Major 8564 DIMM_B2 encountered a Serial Presence Detection (SPD) failure Major 8565 DIMM_B3 encountered a Serial Presence Detection (SPD) failure Major 8566 DIMM_C1 encountered a Serial Presence Detection (SPD) failure Major 8567 DIMM_C2 encountered a Serial Presence Detection (SPD) failure Major 8568 DIMM_C3 encountered a Serial Presence Detection (SPD) failure Major 8569 DIMM_D1 encountered a Serial Presence Detection (SPD) failure Major 856A DIMM_D2 encountered a Serial Presence Detection (SPD) failure Major 856B DIMM_D3 encountered a Serial Presence Detection (SPD) failure Major 856C DIMM_E1 encountered a Serial Presence Detection (SPD) failure Major 856D DIMM_E2 encountered a Serial Presence Detection (SPD) failure Major 856E DIMM_E3 encountered a Serial Presence Detection (SPD) failure Major 856F DIMM_F1 encountered a Serial Presence Detection (SPD) failure Major 8570 DIMM_F2 encountered a Serial Presence Detection (SPD) failure Major 8571 DIMM_F3 encountered a Serial Presence Detection (SPD) failure Major 8572 DIMM_G1 encountered a Serial Presence Detection (SPD) failure Major 8573 DIMM_G2 encountered a Serial Presence Detection (SPD) failure Major 8574 DIMM_G3 encountered a Serial Presence Detection (SPD) failure Major 8575 DIMM_H1 encountered a Serial Presence Detection (SPD) failure Major 8576 DIMM_H2 encountered a Serial Presence Detection (SPD) failure Major 8577 DIMM_H3 encountered a Serial Presence Detection (SPD) failure Major 8578 DIMM_J1 encountered a Serial Presence Detection (SPD) failure Major 8579 DIMM_J2 encountered a Serial Presence Detection (SPD) failure Major 857A DIMM_J3 encountered a Serial Presence Detection (SPD) failure Major 857B DIMM_K1 encountered a Serial Presence Detection (SPD) failure Major 857C DIMM_K2 encountered a Serial Presence Detection (SPD) failure Major 857D DIMM_K3 encountered a Serial Presence Detection (SPD) failure Major 98 Error Message Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS Appendix C: Video POST Code Errors Error Code 857E Error Message DIMM_L1 encountered a Serial Presence Detection (SPD) failure Response Major 857F (Go to 85E0) DIMM_L2 encountered a Serial Presence Detection (SPD) failure Major 85C0 DIMM_L3 failed test/initialization Major 85C1 DIMM_M1 failed test/initialization Major 85C2 DIMM_M2 failed test/initialization Major 85C3 DIMM_M3 failed test/initialization Major 85C4 DIMM_N1 failed test/initialization Major 85C5 DIMM_N2 failed test/initialization Major 85C6 DIMM_N3 failed test/initialization Major 85C7 DIMM_P1 failed test/initialization Major 85C8 DIMM_P2 failed test/initialization Major 85C9 DIMM_P3 failed test/initialization Major 85CA DIMM_R1 failed test/initialization Major 85CB DIMM_R2 failed test/initialization Major 85CC DIMM_R3 failed test/initialization Major 85CD DIMM_T1 failed test/initialization Major 85CE DIMM_T2 failed test/initialization Major 85CF DIMM_T3 failed test/initialization Major 85D0 DIMM_L3 disabled Major 85D1 DIMM_M1 disabled Major 85D2 DIMM_M2 disabled Major 85D3 DIMM_M3 disabled Major 85D4 DIMM_N1 disabled Major 85D5 DIMM_N2 disabled Major 85D6 DIMM_N3 disabled Major 85D7 DIMM_P1 disabled Major 85D8 DIMM_P2 disabled Major 85D9 DIMM_P3 disabled Major 85DA DIMM_R1 disabled Major 85DB DIMM_R2 disabled Major 85DC DIMM_R3 disabled Major 85DD DIMM_T1 disabled Major 85DE DIMM_T2 disabled Major 85DF DIMM_T3 disabled Major 85E0 DIMM_L3 encountered a Serial Presence Detection (SPD) failure Major 85E1 DIMM_M1 encountered a Serial Presence Detection (SPD) failure Major 85E2 DIMM_M2 encountered a Serial Presence Detection (SPD) failure Major 85E3 DIMM_M3 encountered a Serial Presence Detection (SPD) failure Major 85E4 DIMM_N1 encountered a Serial Presence Detection (SPD) failure Major 85E5 DIMM_N2 encountered a Serial Presence Detection (SPD) failure Major 85E6 DIMM_N3 encountered a Serial Presence Detection (SPD) failure Major 85E7 DIMM_P1 encountered a Serial Presence Detection (SPD) failure Major 85E8 DIMM_P2 encountered a Serial Presence Detection (SPD) failure Major Revision 2.2 Intel order number: G39462-013 99 Intel® Server System H2000JF Family TPS Appendix C: Video POST Code Errors Error Code 85E9 Error Message DIMM_P3 encountered a Serial Presence Detection (SPD) failure Response Major 85EA DIMM_R1 encountered a Serial Presence Detection (SPD) failure Major 85EB DIMM_R2 encountered a Serial Presence Detection (SPD) failure Major 85EC DIMM_R3 encountered a Serial Presence Detection (SPD) failure Major 85ED DIMM_T1 encountered a Serial Presence Detection (SPD) failure Major 85EE DIMM_T2 encountered a Serial Presence Detection (SPD) failure Major 85EF DIMM_T3 encountered a Serial Presence Detection (SPD) failure Major 8604 POST Reclaim of non-critical NVRAM variables Minor 8605 BIOS Settings are corrupted Major 8606 NVRAM variable space was corrupted and has been reinitialized Major 92A3 Serial port component was not detected Major 92A9 Serial port component encountered a resource conflict error Major 9505 ATA/ATAPI interface error Major A000 TPM device not detected. Minor A001 TPM device missing or not responding. Minor A002 TPM device failure. Minor A003 TPM device failed self test. Minor A100 BIOS ACM Error Major A421 PCI component encountered a SERR error Fatal A5A0 PCI Express component encountered a PERR error Minor A5A1 PCI Express component encountered an SERR error Fatal A6A0 DXE Boot Services driver: Not enough memory available to shadow a Legacy Option ROM. Minor POST Error Beep Codes The following table lists POST error beep codes. Prior to system video initialization, the BIOS uses these beep codes to inform users on error conditions. The beep code is followed by a user-visible code on POST Progress LEDs. Table 78. POST Error Beep Codes Beeps Error Message USB device action POST Progress Code N/A Description Short beep sounded whenever USB device is discovered in POST, or inserted or removed during runtime. 1 long Intel® TXT security violation 0xAE, 0xAF System halted because Intel® Trusted Execution Technology detected a potential violation of system security. 3 Memory error Multiple System halted because a fatal error related to the memory was detected. 1 The following Beep Codes are sounded during BIOS Recovery. 2 Recovery started N/A Recovery boot has been initiated. 4 Recovery failed N/A Recovery has failed. This typically happens so quickly after recovery is initiated that it sounds like a 2-4 beep code. 100 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS Appendix C: Video POST Code Errors The following Beep Codes are from the BMC. They are listed here for convenience. 1-5-2-1 CPU socket population error N/A CPU1 socket is empty, or sockets are populated incorrectly – CPU1 must be populated before CPU2. 1-5-2-4 MSID Mismatch N/A MSID mismatch occurs if a processor is installed into a system board that has incompatible power capabilities. 1-5-4-2 Power fault N/A DC power unexpectedly lost (power good dropout) – Power unit sensors report power unit failure offset. 1-5-4-4 Power control fault N/A Power good assertion timeout – Power unit sensors report soft power control failure offset. 1-5-1-2 VR Watchdog Timer N/A VR controller DC power on sequence not completed in time. 1-5-1-4 Power Supply Status N/A The system does not power on or unexpectedly powers off and a Power Supply Unit (PSU) is present that is an incompatible model with one or more other PSUs in the system. USB Device Beeps When POST Intel® Server Boards of the S2600JF family are designed to indicate USB readiness by a series of beep codes early during POST, just before video becomes available. These four to five beeps mean that the USB is powered and initialized, in order for USB devices such as keyboard and mouse to become operational. If a USB device such as a pen drive or USB CD/DVD ROM drive is attached to any external USB port, a beep code means that the device is recognized, powered and initialized. Each USB port will issue a beep after an external device is ready for use. These beep codes do not signal any errors. They are designed to advise the user of USB readiness during POST and while attaching external devices. This USB Beep is OS independent. Revision 2.2 Intel order number: G39462-013 101 Intel® Server System H2000JF Family TPS Glossary Glossary Term ACPI Advanced Configuration and Power Interface AP Application Processor APIC Advanced Programmable Interrupt Control ASIC Application Specific Integrated Circuit ASMI Advanced Server Management Interface BIOS Basic Input/Output System BIST Built-In Self Test BMC Baseboard Management Controller Bridge Circuitry connecting one computer bus to another, allowing an agent on one to access the other BSP Bootstrap Processor Byte 8-bit quantity. CBC Chassis Bridge Controller (A microcontroller connected to one or more other CBCs, together they bridge the IPMB buses of multiple chassis.) CEK Common Enabling Kit CHAP Challenge Handshake Authentication Protocol CMOS In terms of this specification, this describes the PC-AT compatible region of battery-backed 128 bytes of memory, which normally resides on the server board DPC Direct Platform Control EEPROM Electrically Erasable Programmable Read-Only Memory EHCI Enhanced Host Controller Interface EMP Emergency Management Port EPS External Product Specification ESB2-E Enterprise South Bridge 2 FBD Fully Buffered DIMM FMB Flexible Mother Board FRB Fault Resilient Booting FRU Field Replaceable Unit FSB Front Side Bus GB 1024MB GPIO General Purpose I/O GTL Gunning Transceiver Logic HSC Hot-Swap Controller Hz Hertz (1 cycle/second) I2 C Inter-Integrated Circuit Bus IA Intel® Architecture IBF Input Buffer ICH I/O Controller Hub ICMB Intelligent Chassis Management Bus IERR Internal Error IFB I/O and Firmware Bridge INTR Interrupt 102 Definition Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS Term Glossary Definition IP Internet Protocol IPMB Intelligent Platform Management Bus IPMI Intelligent Platform Management Interface IR Infrared ITP In-Target Probe KB 1024 bytes KCS Keyboard Controller Style LAN Local Area Network LCD Liquid Crystal Display LED Light Emitting Diode LPC Low Pin Count LUN Logical Unit Number MAC Media Access Control MB 1024KB MCH Memory Controller Hub MD2 Message Digest 2 – Hashing Algorithm MD5 Message Digest 5 – Hashing Algorithm – Higher Security ms milliseconds MTTR Memory Type Range Register Mux Multiplexor NIC Network Interface Controller NMI Nonmaskable Interrupt OBF Output Buffer OEM Original Equipment Manufacturer Ohm Unit of electrical resistance PEF Platform Event Filtering PEP Platform Event Paging PIA Platform Information Area (This feature configures the firmware for the platform hardware.) PLD Programmable Logic Device PMI Platform Management Interrupt POST Power-On Self Test PSMI Power Supply Management Interface PWM Pulse-Width Modulation RAM Random Access Memory RASUM Reliability, Availability, Serviceability, Usability, and Manageability RISC Reduced Instruction Set Computing RMM3 Remote Management Module – 3rd generation RMM3 NIC Remote Management Module – 3rd generation dedicated management NIC ROM Read Only Memory RTC Real-Time Clock (Component of ICH peripheral chip on the server board.) SDR Sensor Data Record SECC Single Edge Connector Cartridge SEEPROM Serial Electrically Erasable Programmable Read-Only Memory Revision 2.2 Intel order number: G39462-013 103 Intel® Server System H2000JF Family TPS Glossary Term Definition SEL System Event Log SIO Server Input/Output SMI Server Management Interrupt (SMI is the highest priority nonmaskable interrupt.) SMM Server Management Mode SMS Server Management Software SNMP Simple Network Management Protocol SSI Server System Infrastructure TBD To Be Determined TIM Thermal Interface Material UART Universal Asynchronous Receiver/Transmitter UDP User Datagram Protocol UHCI Universal Host Controller Interface UTC Universal time coordinate VID Voltage Identification VRD Voltage Regulator Down Word 16-bit quantity ZIF Zero Insertion Force 104 Intel order number: G39462-013 Revision 2.2 Intel® Server System H2000JF Family TPS Reference Documents Reference Documents Refer to the following documents for additional information: Intel® Server Board S2600JF Technical Product Specification (Intel Order Code: G31608) ACPI 3.0: http://www.acpi.info/spec.htm IPMI 2.0 Data Center Management Interface Specification v1.0, May 1, 2008: www.intel.com/go/dcmi PCI Bus Power Management Interface Specification 1.1: http://www.pcisig.com/ PCI Express* Base Specification Rev 2.0 Dec 06: http://www.pcisig.com/ PCI Express* Card Electromechanical Specification Rev 2.0: http://www.pcisig.com/ PMBus*: http://pmbus.org SATA 2.6: http://www.sata-io.org/ SMBIOS 2.4 SSI-EEB 3.0: http://www.ssiforum.org USB 1.1: http://www.usb.org USB 2.0: http://www.usb.org Windows* Logo/SDG 3.0 Intel® Dynamic Power Technology Node Manager 1.5 External Interface Specification using IPMI, 2007. Intel Corporation. Node Power and Thermal Management Architecture Specification v1.5, rev.0.79. 2007, Intel Corporation. Intel® Server System Integrated Baseboard Management Controller Core External Product Specification, 2007 Intel Corporation. Intel® Thurley Server Platform Services IPMI Commands Specification, 2007. Intel Corporation. Intel® Server Safety and Regulatory, 2011. Intel Corporation. (Intel Order Code: G23122) Intelligent Platform Management Bus Communications Protocol Specification, Version 1.0, 1998. Intel Corporation, Hewlett-Packard* Company, NEC* Corporation, Dell* Computer Corporation. Platform Environmental Control Interface (PECI) Specification, Version 2.0. Intel Corporation. Platform Management FRU Information Storage Definition, Version 1.0, Revision 1.2, 2002. Intel Corporation, Hewlett-Packard* Company, NEC* Corporation, Dell* Computer Corporation: http://developer.intel.com/design/servers/ipmi/spec.htm. Revision 2.2 Intel order number: G39462-013 105