JMK Inc. AA-1280-2 Operating Voltage = 115/250 V~ Operating Current = 2 Amps MTBF = 418,471 hours GB Operating Frequency = 50 / 60 Hz Temperature Range = -30 TO 50 Deg. C Diel. Withstand (L-CASE) = 1500 V~ FOR 1 MIN. Diel. Withstand (L-L) = 1500 Vdc For 1 Min. Leakage Current = 0.5 ma @ 250 V~, 60 Hz Discharge Volt after 1.0 second = 35 V Max. Transient Clamping voltage = 354—432 volts Order P/N: LOAD LINE AA-1280-2 INSERTION LOSS (db) 90 80 70 60 50 40 30 20 DM CM 10 0 .01 .04 .02 .1 .07 .4 .2 1 .7 4 2 10 7 40 20 FREQUENCY (MEGAHERTZ) 2.94 2.50 FASTON, 0.25x.032 (4 PL) .188 DIA LINE LOAD JMK, INC. (2 PL) AA-1280-2 115/250 VAC 50/60 HZ 2 AMP, 50C ASSMEBLY IN MEXICO Cx = 0.68 uF Cy = .0033 uF R = 235K Lc = 10.2 mH VARISTOR = 250 V~ 2.00 0.46 0.46 TYP 1.08 1.50 0.61 1.00 0.39 8-32 THR'D GRD TERM (2PL) USA JMK Inc 15 Caldwell Dr. Amherst, NH 03031 EUR JMK Inc Glasgow G13 1DN Scotland UK PH: 603 886-4100 FX: 603 886-4115 email: [email protected] PH: 44-(0) 7785310729 FX: 44-(0) 141-589-1884 100 70