JMK AA-1280-2

JMK Inc.
AA-1280-2
Operating Voltage = 115/250 V~
Operating Current = 2 Amps
Operating Frequency = 50 / 60 Hz
Temperature Range = -30 TO 50 Deg. C
Diel. Withstand (L-CASE) = 1500 V~ FOR 1 MIN.
Diel. Withstand (L-L) = 1500 Vdc For 1 Min.
Leakage Current = 0.5 ma @ 250 V~, 60 Hz
Discharge Volt after 1.0 second = 35 V Max.
Transient Clamping voltage = 354—432 volts
Order P/N:
LOAD
LINE
AA-1280-2
INSERTION LOSS (db)
90
80
70
60
50
40
30
20
DM
CM
10
0
.01
.04
.02
.1
.07
.4
.2
1
.7
4
2
10
7
40
20
FREQUENCY (MEGAHERTZ)
2.94
2.50
FASTON, 0.25x.032
(4 PL)
.188 DIA
LINE
LOAD
JMK, INC.
(2 PL)
AA-1280-2
115/250 VAC
50/60 HZ
2 AMP, 50C
ASSMEBLY IN MEXICO
Cx = 0.68 uF
Cy = .0033 uF
R = 235K
Lc = 10.2 mH
VARISTOR = 250 V~
2.00
0.46
0.46 TYP
1.08
1.50
0.61
1.00
0.39
8-32 THR'D GRD TERM (2PL)
USA
JMK Inc 15 Caldwell Dr. Amherst, NH 03031
EUR
JMK Inc Glasgow G13 1DN Scotland UK
PH: 603 886-4100
FX: 603 886-4115
email: [email protected]
PH: 44-(0) 7785310729 FX: 44-(0) 141-589-1884
100
70