C Band and L Band FWDM

WDM
C Band and L Band FWDM
Parameter
Operating Wavelength Range (Pass Band)
Operating Wavelength Range (Reflect Band)
Insertion Loss (Pass Band)
Insertion Loss (Reflect Band)
Isolation (Pass Band)
Isolation (Reflect Band)
Pass Band Ripple
Return Loss
Directivity
PDL
PMD
Maximum Power Handling
Operating Temperature
Storage Temperature
Bare Fiber (B)
900 µm loose tube (L)
Package Dimension
Specification
1500-1563 nm or 1570-1610 nm
1570-1610 nm or 1500-1563 nm
≤ 0.8 dB
≤ 0.5 dB
≥ 25dB
≥ 12 dB
≤ 0.3 dB
≥ 50 dB
≥ 55 dB
≤ 0.1 dB
≤ 0.1 ps
300 mW
- 0° C ~ + 65° C
- 40° C ~ + 85° C
5.5 mm (Φ) x 35 mm (L)
5.5 mm (Φ) x 39 mm (L)
Note 1: All values specified are without connectors.
Note2: Higher performance specifications are available upon request.
Note3: Fiber Type – Corning SMF-28e.
Note4: Over operating temperature, all SOP.
W D C L
-
C: C band reflection
L: L band reflection
www.lighteltech.com
2210 Lind Ave SW, Suite 100
Renton, WA 98057 USA
(425) 277-8000 ph.
(425) 277-5280 Fax
Fiber Length
A: 1 meter
B: 1.5 meter
S: Special
Pigtail Style
(=Package style)
B: bare fiber
L: 900 µm loose tube
All rights Reserved 2009
Connector
0: None
1: FC/PC
2: FC/APC
3: SC/ PC
4: SC/APC
5: FC/SPC
6: SC/SPC
7: LC/UPC
8: LC/SPC
9: Special
A: FC/UPC
B: SC/ UPC
C: ST