- HiTRON Electronics Corporation

H HiTRON
AC/DC MEDICAL APPLICATION EXTERNAL ADAPTER
UNIVERSAL INPUT SINGLE OUTPUT 45-50 WATTS
SWITCHING POWER SUPPLIES HES49 SERIES
FEATURES:
 ACCOMMODATE UNIVERSAL AC SOURCES
 DESKTOP IEC320-2P/3P AC RECEPTACLE
 MEET MEDICAL STANDARDS EN60601-1/
UL2601-1
 EMI MEET EN 55011/ FCC CLASS B
 CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: 90-264Vac typical.
Input Connector: IEC320-3P DT7 or 2P DT8
AC input receptacle.
Input Frequency: 47-63Hz.
Inrush Current: 32A @230Vac.
Input Current: 0.79A@115Vac & 0.37A @230Vac.
Dielectric Withstand: Meet IEC60601-1.
EMI: Meet EN55011 / FCC Class B.
Hold-up Time: 15mS @115Vac typical.
60mS @230Vac typical.
Over Temp. Protection: Optional (NTC ckt.).
Earth Leakage: Less than 0.1 mA.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: 45-50Watts typical.
Output Connector & Cord: Optional.
Line Regulation: 0.1% typical.
Load Regulation: ±1.5-3.0% typical.
Noise & Ripple: 1.0% typical peak to peak.
OVP: Built-in by latch circuit.
Adjustability: Factory set.
Over Current Protection (OCP): Installed.
Current limiting can be set precisely as per request.
Overload Protection(OLP):
Fully protected against output overload and short circuit.
OLP set at about 125-150% rating output wattage.
Consult the factory for OLP setting.
GENERAL SPECIFICATION
Efficiency: 85-87% typical.
Switching Frequency: 85-110K Hz typical.
Circuit Topology: Fixed Frequency Flyback circuit.
Transient Response: Output voltage returns in less than
3mS following a 25% load change.
Safety Standard: Meet Medical standards UL2601-1/
EN60601-1, Class I for DT7 or Class II for DT8 type.
Power Density: 3.3Watts. / Cubic inch.
Operating Temperature: 0°C to room temperature.
Storage Temperature: -20 to +85°C.
Temperature Coefficient: 0.04% /°C.
Cooling: Free air convection.
Construction: Impact resistant thermo-plastic
enclosure case.
Desktop Format.
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load regulation is measured at 115Vac or 230Vac in percentage to indicate the change in output voltage as the load varied from half load to full load (%).
(3) The exact obtainable load regulation depends upon the output cord selected and load current. Upper data are for 6 ft. (2 m)cord AWG#18 wires.
(4) Due to requests in market and advances in technology, specifications subject to change without notice.
For the details of safety approval, please consult the factory.
Hitron Electronics Corporation. B4-11, P.O. Box 26-110 Kaohsiung Export Processing Zone Kaohsiung 806 Taiwan
TEL: 886-7-8210410/FAX: 886-7-8419917, 886-7-8210511/E-mail: [email protected] /Web-site: www.hitron-e.com
1
MODEL NO. DESCRIPTION: HES49 - X X X Y Y - S
AC INLET TYPE: NONE FOR DT7, [ 8 ] FOR DT8
OUTPUT CURRENT
OUTPUT VOLTAGE
SERIES NAME (HiTRON External Switcher): About 49W.
OUTPUT VOLTAGE / CURRENT RATINGS CHART
SINGLE OUTPUT
MODEL NO.
HES49-05060
HES49-07550
HES49-12040
HES49-15033
HES49-24021
HES49-30020
HES49-12040-8
HES49-15033-8
HES49-24021-8
HES49-30020-8
AC PLUG
DT7
DT7
DT7
DT7
DT7
DT7
DT8
DT8
DT8
DT8
O/P VOLTAGE
5.0Vdc
7.5Vdc
12.0Vdc
15.0Vdc
24.0Vdc
30.0Vdc
12.0Vdc
15.0Vdc
24.0Vdc
30.0Vdc
MECHANICAL DIMENSIONS: MM [INCHES]
O/P CURRENT
6.0A
5.0A
4.0A
3.3A
2.1A
2.0A
4.0A
3.3A
2.1A
2.0A
WEIGHT: 373.0g (13.2 Oz.)
Hitron Electronics Corporation. B4-11, P.O. Box 26-110 Kaohsiung Export Processing Zone Kaohsiung 806 Taiwan
TEL: 886-7-8210410/FAX: 886-7-8419917, 886-7-8210511/E-mail: [email protected] /Web-site: www.hitron-e.com
2