H HiTRON UNIVERSAL INPUT HARMONIC CORRECTION (PFC) AC-DC EXTERNAL DESKTOP SWITCHING ADAPTER 84-98 WATTS GREEN POWER SINGLE OUTPUT HEPG98 SERIES FEATURES: ACCOMMODATE UNIVERSAL AC INPUT DESKTOP IEC320-C6/C8 AC INLET NO LOAD POWER CONSUMPTION < 0.5W MEET IEC61000-3-2 HARMONIC CORRECTION EMI MEET EN55022 / FCC CLASS B MEET UNIVERSAL SAFETY STANDARDS SPECIFICATION INPUT SPECIFICATION OUTPUT SPECIFICATION Input Voltage: Typical 90-264Vac. Power Factor Correction (PFC) installed. Input Connector: 3 pole AC inlet IEC320-C6(DT7L) / 2 pole AC inlet IEC320-C8(DT8). Input Frequency: 47-63Hz. Inrush Current: Typical 10.6Arms at 230Vac. Input Current: Typical 0.97A at 115Vac, 0.5A at 230Vac Dielectric Withstand: Meet IEC60950-1. EMI: Meet EN55022 / FCC Class B. Hold-up Time: Typical 15mS at 115Vac, 28mS at 230Vac. No Load Power: Typical 0.29W at 132Vac, Typical 0.45W at 264Vac. Earth Leakage Current: Less than 0.24mA. Output Voltage: See Ratings Chart. Output Current: See Ratings Chart. Output Wattage: Typical 84-98 Watts. Output Connector: Optional. Line Regulation: Typical 0.2 %. Load Regulation: Typical ± 2.5%. Noise & Ripple: Typical 1% peak to peak. OVP: Built-in. (Latch) Over Temp. Protection (OTP): Installed. Overload Protection (OLP): Fully protected against output overload and short circuit. OLP set at about 110-135% rating output wattage. Consult the factory for OLP setting. GENERAL SPECIFICATION Efficiency: Typical 88-90% (various with output voltage). Switching Frequency: 25-65 KHz. Circuit Topology: Fixed Flyback Circuit. Transient Response: Output voltage returns in less than 1mS following a 25% load change. Safety Standard: Meet UL60950-1/EN60950-1 Class I or II. Harmonic Current Emission, EN61000-3-2 compliance. Operating Temperature: 0 to +40°C without derating. (various with output voltage) Storage Temperature: -20 to +85°C. Cooling: Free air convection. Construction: Impact resistant plastic enclosure case. Power Density: 4.56-5.32Watts/Cubic inch. Desktop Format. NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified. (2) Load regulation is measured at 115Vac or 230Vac in percentage to indicate the change in output voltage as the load is varied from half load to full load (±%). (3) The typical cord length is about 1 meter (3.3 ft.), AWG#18 cord for various load conditions. (4) Due to requests in market and advances in technology, specifications subject to change without notice. For the details of safety approval, please consult the factory. -21- OUTPUT VOLTAGE / CURRENT RATINGS CHART SINGLE OUTPUT (Model No. for example) MODEL NO. AC PLUG O/P VOLTAGE O/P CURRENT HEPG98-S120700-7L IEC320-C6(DT7L) 12Vdc 7.00A HEPG98-S120700-8 IEC320-C8(DT8) 12Vdc 7.00A HEPG98-S150620-7L IEC320-C6(DT7L) 15Vdc 6.20A HEPG98-S150620-8 IEC320-C8(DT8) 15Vdc 6.20A HEPG98-S190510-7L IEC320-C6(DT7L) 19Vdc 5.10A HEPG98-S190510-8 IEC320-C8(DT8) 19Vdc 5.10A HEPG98-S240250-7L IEC320-C6(DT7L) 24Vdc 2.50A HEPG98-S240250-8 IEC320-C8(DT8) 24Vdc 2.50A HEPG98-S240410-7L IEC320-C6(DT7L) 24Vdc 4.10A HEPG98-S240410-8 IEC320-C8(DT8) 24Vdc 4.10A MECHANICAL DIMENSIONS: MM [INCHES] -22- WEIGHT: 550.0g (19.4 Oz.)