HITRON HEG24-033500-3

H HiTRON
AC/DC EXTERNAL WALLMOUNT ADAPTER UNIVERSAL INPUT
SINGLE OUTPUT 24 WATTS GREEN POWER SWITCHING
POWER SUPPLIES HEG24 SERIES
FEATURES:
UNIVERSAL INPUT
DIVERSE WALLMOUNT AC PLUGS
MEET UNIVERSAL SAFETY STANDARDS
GREEN POWER
EMI MEET EN 55022/ FCC CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: 90-264Vac typical.
Input Connector: WM1/WM2/WM3/WM5/WM6.
Input Frequency: 47-63Hz.
Inrush Current: 6.11Arms @230Vac typical.
Input Current: 0.3A @115Vac typical.
0.17A @230Vac typical.
Dielectric Withstand: Meet IEC60950-1
EMI: Meet EN 55022 / FCC Class B.
Hold-up Time: 18.8mS @115Vac typical.
95.2mS @230Vac typical.
Green Power: 0.19W@132Vac & 0.25W @ 264Vac
Earth Leakage: Less than 0.16mA.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: 24 Watts typical.
Output Connector & Cord: Optional.
Line Regulation: 0.3% typical.
Load Regulation: ±3.0% typical.
Noise & Ripple: 1.0% typical peak to peak.
OVP: Built-in.
Overload Protection (OLP):
Fully protected against output overload and short circuit.
OLP set at about 125-150% rating output wattage.
Consult the factory for OLP setting.
GENERAL SPECIFICATION
Efficiency: 80-85% typical. Various with output voltage.
Switching Frequency: Approximate 65K Hz.
Circuit Topology: Fixed Frequency Flyback circuit.
Transient Response: Output voltage returns in less than
1mS following a 25% load change.
Safety Standard: Meet UL60950-1/EN60950-1 Class I or II.
Power Density: 2.17 Watts / Cubic inch.
Operating Temperature: 0 to +25/35/40°C
without derating. (various with output voltage)
Storage Temperature: -20 to +85°C.
Temperature Coefficient: 0.04%/°C typical.
Cooling: Free air convection.
Construction: Impact resistant thermo-plastic
enclosure case.
Wallmount Format.
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load regulation is measured at 115Vac or 230Vac in percentage to indicate the change in output voltage as the load is varied from half load to full load (unit ±%).
For the multi-output, the main output remains 50% load and other aux. output remains 20% load.
(3) The exact obtainable load regulation depends upon the output load current & cord selected. Upper data are for 6 ft. (2 m) cord AWG#18 wires.
(4) Due to requests in market and advances in technology, specifications subject to change without notice.
In application
-21-
MODEL NO. DESCRIPTION: HEG24 - X X X YYY - S
[1]WM1,[2] WM2, [3]WM3,
AC PLUG TYPE
[5] WM5, [6] WM6,
OUTPUT CURRENT
OUTPUT VOLTAGE
SERIES NAME (HiTRON External Switcher) About 24W
OUTPUT VOLTAGE/CURRENT RATINGS CHART
SINGLE OUTPUT (Model No. for example)
MODEL NO.
AC PLUG
O/P VOLTAGE
O/P CURRENT
HEG24-033500-1
WM1
3.3Vdc
5.00A
HEG24-033500-3
WM3
3.3Vdc
5.00A
HEG24-050400-2
WM2
5.0Vdc
4.00A
HEG24-050400-3
WM3
5.0Vdc
4.00A
HEG24-090270-3
WM3
9.0Vdc
2.70A
HEG24-120200-5
WM5
12.0Vdc
2.00A
HEG24-150160-3
WM3
15.0Vdc
1.60A
HEG24-150160-6
WM6
15.0Vdc
1.60A
HEG24-180133-1
WM1
18.0Vdc
1.33A
HEG24-230104-2
WM3
23.0Vdc
1.04A
HEG24-240100-1
WM1
24.0Vdc
1.00A
HEG24-240100-3
WM3
24.0Vdc
1.00A
HEG24-360067-6
WM6
36.0Vdc
0.67A
MECHANICAL DIMENSIONS: MM [INCHES]
-22-
WEIGHT: 240.0g (8.5 Oz.)