Data Sheet

zhen KYL Communication Equipment Co
., Ltd
Shen
Shenz
Co.
KYL-81
KYL-8133 2-way Wireless I/O module
Address: 4th Floor, Building 3, No. 335 of Zhuguang Road, Xili, Nanshan District,
Shenzhen, Guanggong, China 518055
Tel: 86-755-86643962
Fax: 86-755-83408785
Skype
Skype:KYL-Sunny
Yahoo: KYL_Sunny
MSN: [email protected]
Email: [email protected]
Website: http://www.rf-data.com
Tel: 86-755-86643962
Email: [email protected]
Web: www.rf-data.com
zhen KYL Communication Equipment Co
., Ltd
Shen
Shenz
Co.
KYL-813 wireless ON-OFF input and output module is 2-way DI and 2-way
relay DO.
I. Function
2-way ON-OFF DI and DO transmits data timely. The 2-way switching
condition for the transmitting equipment can be transmitted timely to the
receiver equipment. Once the transmitting equipment is switching on; the
receiving equipment will be switching on. When the transmitting equipment is
switching off, the receiver equipment will be off.
Feature:
II
II、Feature:
1、
2-way coupler isolated inputs, high reliability and stability.
2、
2-way relay dry contact output, contact current is 30V 1A.
3、
Collocated with wireless data transmission module whose transmitting
distance is about 2-3km LOS.
Working frequency 433MHz ( or 400/450/470MHz);
Tel: 86-755-86643962
Email: [email protected]
Web: www.rf-data.com
zhen KYL Communication Equipment Co
., Ltd
Shen
Shenz
Co.
RF power: 500mW;
Transmitting current: 350mA
Standby current: 50mA
4、
Power supply: DC 12V (9-15V)
5、
Dimension: 100mm*58mm
I. Parameter Setting
II
III.
Pic 1, parameter setting software
As the picture shows:
User can set parameter via this software. The programmable parameter
Tel: 86-755-86643962
Email: [email protected]
Web: www.rf-data.com
zhen KYL Communication Equipment Co
., Ltd
Shen
Shenz
Co.
includes:
1) module's ID: from 000-255
2) Working channel: there are 16 channel default. Each channel corresponds
to different frequency.
3) Transmitting interval (set TX timer) not work for KYL-813.
VI. How to use the software
1) connect the module with PC, activate the software KYL-81X. Exe to choose
correct COM.
2) power supply for the module. If everything OK, module shows connect
OK. Then user can change parameter according requirements.
V. Exterior sketch
Tel: 86-755-86643962
Email: [email protected]
Web: www.rf-data.com
zhen KYL Communication Equipment Co
., Ltd
Shen
Shenz
Co.
VI
VI.. Connection Definition
Connection name
Pin No.
Definition
VCC
DC 12V (9-15V)
GND
Power supply
Remarks
CN1
1
2
3
4
5
6
7
GND
INT1
GND
INT2
2nd channel signal input
OUT1A
1st channel relay output
contact
1st channel relay output
contact
2nd channel relay output
contact
2nd channel relay output
contact
8
OUT1B
9
OUT2A
10
1st channel signal input
OUT2B
A When the relay close , A and B
will connect
B
A When the relay chose, AandB
will connect
B
CN2 (it’s program port, for module’s parameter setting use)
1
RXD
Serial Data Receiving
2
TXD
Serial Data Transmitting
3
GND
Ground of the signal
4
GND
Ground of the signal
5
PRO SET
Program controlling
6
NC
ANT
ANT
Setting module, serial function is
valid
Program controlling , low level
valid. When this pin connects
with signal ground, module will
enter to program mode
Antenna port
Application Example:
On-off wireless transmission
Tel: 86-755-86643962
Email: [email protected]
Web: www.rf-data.com
zhen KYL Communication Equipment Co
., Ltd
Shen
Shenz
Co.
Remote control ON-OFF on PC
For more details, welcome to contact us freely.
Tel: 86-755-86643962
Email: [email protected]
Web: www.rf-data.com