Data Sheet

., Ltd
Shenzhen KYL Communication Equipment Co
Co.,
KYL-815 4-way wireless ON-OFF Module
I. Introduction
This 4-way ON-OFF module is to transmit the ON-OFF condition to a remote place
wirelessly in time. When here the switch condition is ON, the output in the remote
place is ON. When the local switch condition is OFF, the other terminal is OFF.
KYL-815
KYL-815
II
II.. Features of KYL-815
1. 4-way isolated input, high reliability and stability.
2. 4-way relay dry contact output, contact current is 220V, 5A.
3. Collocated with a wireless data module inside whose transmitting distance is about
83410706
Tel: +86-755+86-755-83410706
[email protected]
Email: sales0
sales01
Web: www.rf-data.com
., Ltd
Shenzhen KYL Communication Equipment Co
Co.,
2km-3km; the working frequency 433MHz (400-470MHz); RF power: 1000mW;
4. Receiving sensitivity: -120dBm
5. Receiving current: 60mA; transmitting current: 350mA
6. Power supply: DC 12V-30V
7. Dimension: 95mm*90mm*40mm
III
III.. Dip Switch Instruction
Pic 1. DIP Switch
Working method
DIP8
DIP8:Working
ON—input changes trigger transmission. Once you change any of the 4-way's
condition, the module will send out this info.
OFF---fixed time transmitting. The master transmits 4-way's condition to the
slave every 1s or 2s (not real-time transmitting).
Master and slave choosing under the fixed time transmitting
DIP7
DIP7:Master
mode
ON—slave,OFF—master
Data collecting mode choosing
DIP6
DIP6:Data
ON---Point to point transmission mode
OFF---Data collection mode
The master collects input condition or controls output condition via sending data. In
data collecting mode, the module can't send out data actively. That is to say touch off
transmitting and fix time transmitting are both invalid at this mode.
Feedback choice
DIP5
DIP5:Feedback
ON--feedback function close
OFF--receiver will send back the received data to transmitter
Channel choosing
DIP1-4
DIP1-4:Channel
To avoid interference, please use different DIP switch mode and choose different
channels when you use several pairs of modules in the same place , Maximal 16
channels.
83410706
Tel: +86-755+86-755-83410706
[email protected]
Email: sales0
sales01
Web: www.rf-data.com
., Ltd
Shenzhen KYL Communication Equipment Co
Co.,
The following is a channel correspondence table for DIP switch 1-4:
DIP
position
Channel
No
DIP
Ch.
DIP
Ch.
DIP
Ch.
1
5
9
13
2
6
10
14
3
7
11
15
4
8
12
16
Notice:
* For most users "touch off transmitting mode" is OK-----DIP7-ON
* To avoid interference caused by more pairs of modules working in the same place,
please choose different channels for different systems.
* In timing mode, there should be a master and a slave.
* changing the DIP switch just takes effect after the module is re-powered on.
IV
IV.. Wiring Terminal Schematic
Pic 2:Switch input wiring terminal schematic
83410706
Tel: +86-755+86-755-83410706
[email protected]
Email: sales0
sales01
Web: www.rf-data.com
., Ltd
Shenzhen KYL Communication Equipment Co
Co.,
Pic 3: Switch output wiring terminal schematic
V. Pin Definition:
Port name
COM1
COM2
Pin No.
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
4
5
6
7
8
Definition
GND
VCC
OUT1
remarks
GND
DC:12-30V
No conection
No connection
No connection
1st way relay day contact output
OUT2
2nd way relay day contact output
OUT3
3rd way relay day contact output
OUT4
IN1
GND
IN2
GND
IN3
GND
IN4
GND
4th way relay day contact output
1st ON-OFF input
2ns ON-OFF input
3rd ON-OFF input
4th ON-OFF input
VI
VI.. How to use KYL-815
1. Consider your specific application, set the DIP switch, connect VCC (12V-30V
DC) and connect input and output cables as per the above instruction.
2. Power supply for the module.
83410706
Tel: +86-755+86-755-83410706
[email protected]
Email: sales0
sales01
Web: www.rf-data.com
., Ltd
Shenzhen KYL Communication Equipment Co
Co.,
3. The factory setting is input changes trigger transmission mode and current
channel is No.1.
4. Choose different frequency points to avoid interference caused by more pairs of
modules working in the same area.
VII
VII.. About the LED Indicator:
1. The power LED--It is always ON if modem is power supplied.
2. The data LED--It blinks once modem transmits or receives data
3. The working LED--It blinks every 1s, this indicates modem is working normally
4. The output LED--It's on indicates the corresponding output condition is connect.
It's off indicates the corresponding output condition is disconnect.
VIII
VIII.. Working Mode Instruction
1. Touch off transmitting mode
Once there is any input change happens, the module will send it out. This mode
has the advantage of high speed, real-time transmission, and low power
consumption. Because module only transmits if there is input changes.
2. Fixed time transmitting mode
Under this mode, there should be one master and one slave module. The master
will synchronize with the slave every 1s, means the master will transmits its
condition to slave every 1S and the slave will transmits its condition to master
every 1S. If the master cannot synchronize with slave, the buzzer inside of module
will alarm. And all contacts will disconnect at the same time. This alarm will stop
automatically until the master is synchronize with slave again.
There will be at most 1s ON-OFF delay under this mode.
83410706
Tel: +86-755+86-755-83410706
[email protected]
Email: sales0
sales01
Web: www.rf-data.com