AR5005 THRU AR508

BUTTON AUTOMOTIVE RECTIFIER
AR5005 THRU AR508
ARS5005 THRU ARS508
•
•
•
CURRENT
50.0 Amperes
ARS
.185(4.7)
.165(4.2)
Low Leakage
Low forward voltage drop
High current capability
High forward surge current capacity
.185(4.7)
.165(4.2)
.250(6.4)
.235(6.0)
MECHANICAL DATA
•
•
•
50 to 600 Volts
AR
FEATURES
•
•
•
•
VOLTAGE RANGE
Case: transfer molded plastic
Epoxy: UL94V-0 rate flame retardant
Lead: Plated slug , solderable per MIL-STD-202E
method 208C
Polarity: Color ring denotes cathode end
Mounting Position: any
Weight: 0.064 ounces, 1.82 grams
.225(5.7)DIA
.215(5.5)TYP
.250(6.4)
.235(6.0)
.410(10.4)DIA
.380(9.7)TYP
.346(8.8)DIA
.327(8.2)TYP
.225(5.7)DIA
.215(5.5)TYP
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
•
•
•
Ratings at 25℃ ambient temperature unless otherwise specified
Single Phase, half wave, 60HZ, resistive or inductive load
For capacitive load derate current by 20%
SYMBOLS
AR5005
AR501
AR502
AR504
AR506
AR508
ARS5005
ARS501
ARS502
ARS504
ARS506
ARS508
UNIT
Maximum Repetitive Peak Reverse Voltage
VRRM
50
100
200
400
600
800
Volts
Maximum RMS Voltage
VRMS
35
70
140
280
420
560
Volts
Maximum DC Blocking Voltage
VDC
50
100
200
400
600
800
Volts
Maximum Average Forward Rectified Current,
At Tc=110℃
IO
50.0
Amps
IFSM
600
Amps
Peak Forward Surge Current
3.3mS single half sine wave superimposed on
Rated load (JEDEC method)
Maximum instantaneous Forward Voltage at 80A
VF
Maximum DC Reverse Current at Rated TA=25℃
DC Blocking Voltage per element TA=100℃
Typical Thermal Resistance
Operating and Storage Temperature Range
1.08
Volts
5.0
IR
UA
400
RθJC
0.8
℃/W
TJ,TSTG
(-65 to +175)
℃
Polarity and voltage demotion color band
Red
Yellow
Notes:
1.
1.10
Enough heatsink must be considered in application.
Web Site: www.hkmic.com
Silver
Green
Green
Blue
BUTTON AUTOMOTIVE RECTIFIER
AR5005 THRU AR508
ARS5005 THRU ARS508
60
50
40
Single Phase
Half Wave 60Hz
Resistive or
Inductive Load
10
CURRENT
50.0 Amperes
F1G.2 MAXIMUM NON-REPETITIVE PEAK
FORWARD SURGE CURRENT
PEAK FORWARD SURGE
CURRENT,(A)
AVERAGE FORWARD CURRENT,
(A)
F1G.1 TYPICAL FORWARD CURRENT
DERATING GURVE
20
50 to 600 Volts
AR5005 THRU AR508
ARS3505 THRU ARS508
RATINGS AND CHARACTERISTIC CURVES
30
VOLTAGE RANGE
600
8.3ms Single Half Sine-Wave
500
(JEDEC Method) Tj=Tj max
400
300
200
100
1 Cycle
0.375″(9.5mm) Lead Length
0
1
0
0
25
50
75
110
100
125
150
175
2
4
6
8 10
20
40
60
100
NUMBER OF CYCLES AT 60 Hz
CASE TEMPERATURE, (℃)
F1G.3 TYPICAL INSTANTANEOUS
FORWARD CHARACTERISTICS
F1G.4 FORWARD ROWER DISSIPATION
AVERAGE POWER DISSIPATION
(W)
INSTANTANEOUS FORWARD CURRENT,
(A)
1000
100
10
T1=25℃
PULSE WIDTH=300μS
1%DUTY CYCLE
0.8
1.0
1.2
1.4
1.6
40
SQUARE WAVE
20
0
0
20
30
40
50
AVERAGE FORWARD CURRENT, (A)
1.0
0.1
0.6
60
1.8
2.0
INSTANTANEOUS FORWARD VOLTAGE,(V)
Web Site: www.hkmic.com
60