CCF-UM - KOA Speer Electronics

CCF-UM
universal modular fuse-links
EU
features
•
•
•
•
•
•
Meets IEC60127-4:2005 ED.3 specifications
Excellent mechanical strength with ceramic body
Stable fusing characteristics due to the original technology
Excellent anti-surge characteristics
Marking: White body color with black marking
Products with lead-free terminations meet EU RoHS
and China RoHS requirements
dimensions and construction
Dimensions inches (mm)
W
t
W
L
t
Type
L
CCF
.236±.008
(6.0±0.2)
.098±.008
(2.5±0.2)
d
.098±.008
(2.5±0.2)
.055±.008
(1.4±0.2)
d
d
Ceramic Fuse
Case
Element
circuit
protection
End Cap
ordering information
New Part #
CCF
1
Type
Style
F
1
UM
T
Fusing
Characteristic
F: Fast-acting
Rated
Current
Reference
rating chart
Rated Voltage
(IEC)
UM: 125Va.c.
/125Vd.c.
Termination
Material
T: Sn
TE
Packaging
TE: 4mm
pitch plastic
embossed
For further information on packaging,
please refer to Appendix A.
Specifications given herein may be changed at any time without prior notice. Please confirm technical specifications before you order and/or use.
2/28/08
KOA Speer Electronics, Inc. • 199 Bolivar Drive • Bradford, PA 16701 • USA • 814-362-5536 • Fax: 814-362-8883 • www.koaspeer.com
243
CCF-UM
universal modular fuse-links
applications and ratings
Part
Designation
Current
Rating
CCF1F0.4
CCF1F0.5
CCF1F0.63
CCF1F0.8
CCF1F1
CCF1F1.25
CCF1F1.6
CCF1F2
CCF1F2.5
CCF1F3.15
CCF1F4
CCF1F5
400mA
500mA
630mA
800mA
1A
1.25A
1.6A
2A
2.5A
3.15A
4A
5A
CCF1F6.3
6.3A
Operating
Interrupting
Temperature
Capacity
Range
Voltage
Rating
-55°C
to
+125°C
AC 125V
DC 125V
AC 125V
50A
DC 125V
50A
Fusing
Characteristics
Fusing
Rated
Time
Current
1 hour min.
120 sec.
max.
0.001 sec.
min.
0.01 sec.
max.
125%
200%
1000%
Internal R.
(mΩ) Max.
Normal
Melting
l2t (A2, sec.)
510
390
250
200
90.4
75.9
59.3
42.9
36.6
26.0
20.1
13.2
0.030
0.052
0.087
0.185
0.156
0.220
0.513
0.814
1.31
2.37
3.85
7.78
8.2
16.9
AC 125V 63A
DC 125V 63A
Maximum
Maximum
Sustained
Voltage
Dissipation
Drop (mV)
(mW)
500
700
500
600
500
500
500
400
500
300
1000
300
1000
300
1000
300
1200
300
1500
300
2000
300
2500
300
3000
300
environmental applications
Fusing Characteristics
10
-35
-15
5
25
45
65
85
105
1
.1
.01
.001
0.1
125
Ambient Temperature
(°C)
0.4
0.5
0.63
0.8
1
1.25
1.6
2
2.5
3.15
4
5
6.3
1.5
1.4
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
-55
Fusing Time (Sec.)
Derating Coefficient Number
Derating Curve
1
10
100
Fusing Current
(A)
circuit
protection
Performance Characteristics
Parameter
Fusing Characteristics
Requirement
Limit
Within specified time. Insulation
resistance shall not be less than 0.1MΩ
Typical
Test Method
—
Fusing time measured under rated current x 200% and x 100%
Maximum temperature rise
85°C and not fusing
—
Surface temperature should be measured by rated current x 125%
Voltage Drop
Refer to ratings table
—
When the fuse-link has carried its rated current for a time sufficient
to reach temperature stability
Maximum Sustained
Dissipation
Refer to ratings table
Surface Temperature Rise
Bending Test
Resistance to Soldering Heat
Shall not exceed
the ratings table
Shall not exceed
the ratings table
—
—
—
Load Life
±10%
±5.0%
Load Life Moisture
±10%
±5.0%
Rapid Change of Temperature
±10%
±5.0%
At the end of electrify test to rated current x 125%, the voltage drop
across the fuse-link is measured and used for the calculation of the
sustained dissipation
Distance between holding points 90mm, bent by 1mm at rate
of 1mm/second
260°C ± 5°C, 10 seconds ± 0.5 seconds, After the solder depth,
voltage drop across the fuse-link is measured
70°C ± 2°C, 1000 hours, rated current x 70%, 1.5 hr ON,
0.5 hr OFF cycle
40°C ± 2°C, 90 - 95% RH, 1000 hours, rated current x 70%,
1.5 hr ON, 0.5 hr OFF cycle
-55°C (30 minutes), +125°C (30 minutes), 100 cycles
Specifications given herein may be changed at any time without prior notice. Please confirm technical specifications before you order and/or use.
244
11/21/08
—
KOA Speer Electronics, Inc. • 199 Bolivar Drive • Bradford, PA 16701 • USA • 814-362-5536 • Fax: 814-362-8883 • www.koaspeer.com