English

LUMBERG
CONNECT
GMBH
Processing Instruction
Im Gewerbepark 2
58579 Schalksmühle
35V01EN
Connector
RAST 2.5
Page 1 of 23
3510 / 3511
(not illustrated)
3512 / 3513
(not illustrated)
Date
Name
Edition
1
2
3
4
Author
23.09.2003
fs
Name
str
gz
sve
Fs
Checked
19.09.2014
pfa
Date
19.04.04
21.02.07
26.07.13
16.09.2014
LUMBERG
CONNECT
GMBH
Im Gewerbepark 2
58579 Schalksmühle
Processing Instruction
Connector
RAST 2.5
3515 / 3516
(not illustrated)
3517 / 3518
(not illustrated)
35V01EN
Page 2 of 23
LUMBERG
CONNECT
GMBH
Im Gewerbepark 2
58579 Schalksmühle
Processing Instruction
Connector
RAST 2.5
3520 / 3522
(not illustrated)
3521 / 3523
(not illustrated)
35V01EN
Page 3 of 23
LUMBERG
CONNECT
GMBH
Processing Instruction
Connector
RAST 2.5
Im Gewerbepark 2
58579 Schalksmühle
35V01EN
Page 4 of 23
Alteration Description
Edition
Alterations carried out
1
5.3 and 7.6: 11-0,15 was 11,5-0,15
2
Change of name and inspection note added.
3
Produkt types 3512/3513 added, Information: “For each number of
poles a special die is required” added by type 3517/3518. Processing
Insruction with new layout.
4
Added illustration of mechanism for the pull-out force; Added in
section 7.10 Electrical testing and information for separating the
connecting of links, with image. Modified dimension for the wire end
position: from 0.3 mm to 0.6 mm.
LUMBERG
CONNECT
GMBH
Im Gewerbepark 2
58579 Schalksmühle
Processing Instruction
Connector
RAST 2.5
35V01EN
Page 5 of 23
Contents:
1. System features .......................................................................................................................... 6
1.1 Product types ........................................................................................................................... 8
Direct connector 3510............................................................................................................... 9
Direct connector 3511............................................................................................................... 9
Direct connector 3512............................................................................................................. 10
Direct connector 3513............................................................................................................. 10
Direct connector 3515............................................................................................................. 11
Direct connector 3516............................................................................................................. 11
Direct connector 3517............................................................................................................. 11
Direct connector 3518............................................................................................................. 11
Indirect connector 3520 .......................................................................................................... 12
Indirect connector 3522 .......................................................................................................... 12
Indirect connector 3521 .......................................................................................................... 13
Indirect connector 3523 .......................................................................................................... 13
2. Contact principle ....................................................................................................................... 13
3. Application tooling and machines for 3510, 3511, 3512, 3513, 3517, 3518, 3520, 3521, 3522
and 3523 ......................................................................................................................................... 14
4. Cable specification ................................................................................................................... 15
4.1 Cable specifications cross section for connection 0,20...0,22 mm² ......................................... 15
4.2 Cable specifications cross section for connection 0,38mm² .................................................... 15
4.3 Cable specifications cross section for connection 0,35mm² .................................................... 15
4.4 Cable specifications cross section for connection 0,14mm² .................................................... 15
5. Assembly ................................................................................................................................... 16
5.1 Connector feed ....................................................................................................................... 16
5.2 Impression die stamp.............................................................................................................. 17
5.3 Shut height dimension of the termination machine.................................................................. 17
5.4 Wire end position .................................................................................................................... 18
5.5 Wire (stranded wire / flat cable) .............................................................................................. 18
5.6 Housing .................................................................................................................................. 19
6. Cutting-off coding keys ............................................................................................................ 20
6.1 Coding acc. to RAST 2.5 ........................................................................................................ 20
6.2 Cutting blades ........................................................................................................................ 20
7. Quality assurance ..................................................................................................................... 21
7.1 Quality features ...................................................................................................................... 21
7.2 Quality features / IDC ............................................................................................................. 21
7.3 ID slot width ............................................................................................................................ 21
7.4 Symmetry of the ID slot .......................................................................................................... 21
7.5 Cable quality........................................................................................................................... 21
7.6 Contact insertion depth ........................................................................................................... 22
7.7 Cable protrusion ..................................................................................................................... 22
7.8 Retention force of the wire ...................................................................................................... 22
7.9 Contact gap ............................................................................................................................ 23
7.10 Electrical testing .................................................................................................................. 23
8. Storage ...................................................................................................................................... 23
LUMBERG
CONNECT
GMBH
Processing Instruction
Im Gewerbepark 2
58579 Schalksmühle
Connector
RAST 2.5
1. System features
Two-part body
Supplied in following stacks
Wire termination
Insulation displacement connection by pressing the top
Wire exit 90°
35V01EN
Page 6 of 23
LUMBERG
CONNECT
GMBH
Processing Instruction
35V01EN
Connector
RAST 2.5
Im Gewerbepark 2
58579 Schalksmühle
Page 7 of 23
The connectors are used with pin headers as indirect connectors or with guide frames as
indirect connectors (edge connectors).
Connector acc. to RAST 2.5
Pin header
Guide frame
LUMBERG
CONNECT
GMBH
Processing Instruction
Connector
RAST 2.5
Im Gewerbepark 2
58579 Schalksmühle
1.1 Product types
Direct or indirect connectors in insulation displacement technology (IDT)
acc. to Rast 2.5
Material of the connector: PBT
PA
Connectable wire in insulation displacemnent area
for 4A
2....20-pole
351x (-1,-2)
351x (-1,-2) S01
351x (-1,-2) S02
351x (-1,-2) S03
352x (-1,-2)
352x (-1,-2) S01
352x (-1,-2) S02
352x (-1,-2) S03
cross section for connection 0,22mm²....0,38mm²
cross section for connection 0,34mm²
cross section for connection 0,14mm²….0,22mm²
special application, e.g. varnisched wire
cross section for connection 0,22mm²....0,38mm²
cross section for connection 0,34mm²
cross section for connection 0,14mm²….0,22mm²
special application, e.g. varnisched wire
V = finishing variant
max. insulation diameter ∅1,6mm
standard design
design -1 for bus capable flat cable
design -2 for flat cable
35V01EN
Page 8 of 23
LUMBERG
CONNECT
GMBH
Processing Instruction
Im Gewerbepark 2
58579 Schalksmühle
35V01EN
Connector
RAST 2.5
Page 9 of 23
Direct connector 3510
Coding
(optional)
Partition 2.5mm
acc. to spec sheet 3510 01
Positioning
(optional)
Direct connector 3511
Partition 5mm
acc. to spec sheet 3511 01
Coding
(optional)
Positioning
(optional)
LUMBERG
CONNECT
GMBH
Processing Instruction
Im Gewerbepark 2
58579 Schalksmühle
Connector
RAST 2.5
35V01EN
Page 10 of 23
Direct connector 3512
Partition 2.5mm
acc. to spec sheet 3512 01
For each number of poles
a special die is required
Locking
Direct connector 3513
Partition 5mm
acc. to spec sheet 3513 01
For each number of poles
a special die is required
Locking
LUMBERG
CONNECT
GMBH
Processing Instruction
Im Gewerbepark 2
58579 Schalksmühle
Connector
RAST 2.5
35V01EN
Page 11 of 23
Direct connector 3515
Partition 2.5mm
acc. to spec sheet 3515 01
For each number of poles
a special die is required
Locking
Direct connector 3516
Partition 5mm
acc. to spec sheet 3516 01
For each number of poles
a special die is required
Locking
Direct connector 3517
Partition 2.5mm
acc. to spec sheet 3517 01
For each number of poles
a special die is required
Locking
LUMBERG
CONNECT
GMBH
Processing Instruction
Im Gewerbepark 2
58579 Schalksmühle
Connector
RAST 2.5
35V01EN
Page 12 of 23
Direct connector 3518
Partition 5mm
acc. to spec sheet 3518 01
For each number of poles
a special die is required
Verrastung
Locking
Indirect connector 3520
Partition 2.5mm
acc. to spec sheet 3520 01
interior locking
Indirect connector 3522
Partition 5mm
acc. to spec sheet 3522 01
interior locking
LUMBERG
CONNECT
GMBH
Processing Instruction
Connector
RAST 2.5
Im Gewerbepark 2
58579 Schalksmühle
35V01EN
Page 13 of 23
Indirect connector 3521
Partition 2.5mm
acc. to spec sheet 3521 01
Indirect connector 3523
Partition 5mm
acc. to spec sheet 3523 01
2. Contact principle
Insulation displacement connection
(test acc. to DIN EN/IEC 60352-4)
Contact pin 1,5 mm
PCB 1,5mm
LUMBERG
CONNECT
GMBH
Im Gewerbepark 2
58579 Schalksmühle
Processing Instruction
Connector
RAST 2.5
35V01EN
Page 14 of 23
3. Application tooling and machines for 3510, 3511, 3512, 3513, 3517,
3518, 3520, 3521, 3522 and 3523
The function, safety and quality of the connectors are only guaranteed by using of
LUMBERG processing equipment. It has to be taken into account that the connectors aren’t
checked electrically before the processing / assembling. Because of that an electrical test
should be carried out after processing / assembling
The user bears full responsibility if any other processing equipment is used.
In case of using any lubricants or sliding agents in the feed and press areas residues
(impurities) must not come into contact with the connectors.
Manual processing tool
For fitting single wires and ribbon cables. For single and small series.
Manual processing device
For fitting single wires and ribbon cables. For small series.
Pneumatic processing device
Pneumatically assisted processing device with manual cable feed and connector feed. For
small and middle series.
Semi-automatic processing device
To the economic assembling of automatic connector feed and manual cable feed. For serial
production.
Automatic processing device
For optimal assembling of automatic wire feed and connector feed. For industrial mass
production.
LUMBERG
CONNECT
GMBH
Processing Instruction
Im Gewerbepark 2
58579 Schalksmühle
35V01EN
Connector
RAST 2.5
Page 15 of 23
4. Cable specification
The cable specification must be kept. Any deviation must be discussed and approved by
LUMBERG.
4.1 Cable specifications cross section for connection 0,20...0,22 mm²
Technical specification sheet 902 01 flat cable
Technical specification sheet 902 03 flat cable
Technical specification sheet 902 04 flat cable
=0,20mm²
=0,22mm²
=0,22mm²
4.2 Cable specifications cross section for connection 0,38mm²
Technical specification sheet 908 14 PVC-stranded wire
=0,38mm²
4.3 Cable specifications cross section for connection 0,35mm²
Technical specification sheet 908 32 FLR-stranded wire
=0,35mm²
4.4 Cable specifications cross section for connection 0,14mm²
Technical specification sheet 908…
Other approved cable see LUMBERG release list in the internet at
www.lumberg.com
=0,14mm²
LUMBERG
CONNECT
GMBH
Im Gewerbepark 2
58579 Schalksmühle
Processing Instruction
35V01EN
Connector
RAST 2.5
Page 16 of 23
5. Assembly
Connector and cross section should be adapted with each other acc. LUMBERG
specification (see technical Datasheet).
5.1 Connector feed
The lower housing must be cut off before the first stack of connectors is fed into the
termination head. To feed a new stack into the machine the upper housing of the stack in
the machine must be placed into the lower housing of the new stack. The cutting-off of the
single connector from the stack is done by the machine. The links will remain on the
connector. The connection of links typically remain on the connector in this case.
These links can be removed if the customer requires it.
cut-off lower housing
first stack
following stacks
to the machine
LUMBERG
CONNECT
GMBH
Processing Instruction
35V01EN
Connector
RAST 2.5
Im Gewerbepark 2
58579 Schalksmühle
Page 17 of 23
5.2 Impression die stamp
Only use impression die stamps from LUMBERG
Impression die stamps: free of lubricants and sliding agents.
5.3 Shut height dimension of the termination machine
Impression die stamp
11 -0,15
Shut height dimension
(standard gauge 5.45)
13,5 -0,1
An important feature for the correct function of the connector is the connector height,
messed 30 min. after assembling. It is determined by the shut height dimension of the
termination machine. The height adjustment will be determined max. 30 minutes after the
pressing process and must be within the specification.
LUMBERG
CONNECT
GMBH
Processing Instruction
Im Gewerbepark 2
58579 Schalksmühle
Connector
RAST 2.5
35V01EN
Page 18 of 23
5.4 Wire end position
The correct position of the wire guarantees the mating of both ID slots. After termination no
cable protrusion is allowed at the connector in order to ensure a correct mating and
dismating of the connection. The correct position of the wire ensures the mating of both ID
slots. The wire insulation may only be removed from the area specified.
5.5 Wire (stranded wire / flat cable)
No cuts in the insulation are allowed in wire exit direction (visual check). The cables must be
cut off without burr and deformity. Insulation cuts are permitted between the ID slots of the
contact.
Flat cables must be punched out.
LUMBERG
CONNECT
GMBH
Processing Instruction
Im Gewerbepark 2
58579 Schalksmühle
35V01EN
Connector
RAST 2.5
Page 19 of 23
5.6 Housing
After termination no visual damages of the housing are allowed (visual check).
The links must be cut off without burr.
The mating function must be guaranteed (functional test).
The contact must be in correct position in the housing (visual check).
burr
Max. 0,1
Standard
burr
+0,6
0
Separated
of links
Make sure that the cut-off links are no longer adhering to the component and that they do
not remain in the connector after they are cut off.
LUMBERG
CONNECT
GMBH
Processing Instruction
Im Gewerbepark 2
58579 Schalksmühle
35V01EN
Connector
RAST 2.5
Page 20 of 23
6. Cutting-off coding keys
The cutting-off coding keys acc. to RAST 2.5 standard at the termination machine and the
allocation of connector, color marking and cutting-off coding keys are the sole responsibility
of the customer.
Caution !
Connectors, pin headers and guide frames are always marked in mating direction.
6.1 Coding acc. to RAST 2.5
basic connector in mating direction
coding
6.2 Cutting blades
To ensure a correct cutting-off of the coding keys, use only LUMBERG cutting blades. A
minimal remaining burr is permitted.
LUMBERG
CONNECT
GMBH
Processing Instruction
Im Gewerbepark 2
58579 Schalksmühle
Connector
RAST 2.5
35V01EN
Page 21 of 23
7. Quality assurance
For all working and processing steps and alterations (e. g. product launch, changes of the
cable, changes of the tool or machine …), which may affect the product quality, the
responsible departments have to take care for appropriate quality assurance steps.
7.1 Quality features
The following quality features must be taken into consideration:
7.2 Quality features / IDC
•
•
•
•
•
•
ID slot width
Symmetry of the ID slot
Cable quality
Cable insertion depth
Cable protrusion
Electrical testing
7.3 ID slot width
LUMBERG guarantees correct ID slot.
7.4 Symmetry of the ID slot
Symmetry of ID slot (cable tolerance ±0,1) is guaranteed by the body.
7.5 Cable quality
The cable must meet LUMBERG specification acc. to point 4.1.
Customized cables, which are listed in the release lists, have to correspond with the
available specification sheets.
Only LUMBERG released cables are to be used. The customer bears full responsibility for
the correct mating when cables are used which are not listed in the release lists.
LUMBERG
CONNECT
GMBH
Processing Instruction
Im Gewerbepark 2
58579 Schalksmühle
35V01EN
Connector
RAST 2.5
Page 22 of 23
7.6 Contact insertion depth
11 -0,15
ID slot area
The wire insertion depth is determined by the height of the body. All single conductors must
be in the ID slot area.
7.7 Cable protrusion
The cable protrusion acc. to point 5.4 must be kept. A protrusion of the cable in the housing
leads to an incorrect mating.
7.8 Retention force of the wire
Minimal retention force of the wire from the insulation displacement contact:
PVC – stranded wire:
0,38mm²
>
50N.
F
F
The stated value for the conductor's pull-out force is the typical value established during a
test carried out with a standard 0,38 mm² line. All values were determined under laboratory
conditions and serve as a reference.
LUMBERG
CONNECT
GMBH
Processing Instruction
Im Gewerbepark 2
58579 Schalksmühle
Connector
RAST 2.5
35V01EN
Page 23 of 23
7.9 Contact gap
Contact gap after termination.
7.10 Electrical testing
Electrical testing shall be performed in accordance with IPC/WHMA-A-620.
The nature and extent of the electrical tests (short circuit testing, continuity testing,
insulation testing, high voltage testing, etc.) should be specified depending on the
application and the processing machine.
8. Storage
Tin-plated and silver-plated surfaces can undergo a physical aging process that may
negatively affect their ability to be soldered. In order to maintain the best connection
characteristics, make sure that the following instructions are closely followed during
additional processing steps:
Storage conditions:
The parts should ideally be stored in the original packaging, at a constant temperature of 21
– 25° C, with a relative humidity of no more than 55%. The components should not be
exposed to direct light. They should also be protected from any extreme ambient conditions
(such as air pollution).
The storage time should be kept as short as possible, especially for silver-plated
components and for solder connections in general. Our experience is that tin-plated
components can be soldered for about a year after delivery when using the proper
conventional flux. Silver-plated components, owing to their physical characteristics, should
be processed within about six months of delivery.
These specifications are based on experience using components stored under optimal
conditions. They do not constitute a binding commitment for the fulfillment of any
characteristics.