MI600xERU Datasheet

MI600ERU Series
4:1 Input, 6W
Ultra-Miniature
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
Input
• 6W Output Power
Parameter
• 4:1 Input Range
Input Voltage Range
• Miniature 1” x 1” Case
Input Filter
• Single & Dual Outputs
• 1,500 VDC Isolation
• >1 MHour MTBF
• 16 Standard Models
• LOW COST!!
Conditions
Min.
24 VDC Input
9.0
48 VDC Input 18.0
Pi (␲) Filter
Typ.
24.0
48.0
Max.
36.0
75.0
Units
Conditions
Typ.
±1.0
±0.5
±0.2
±0.5
15
50
300
±3.0
±0.03
Max.
±2.0
±1.5
±0.5
±1.0
25
75
500
±5.0
Units
%
%
%
%
mV P - P
mV P - P
µSec
%
%/ºC
%VOUT
%IOUT
VDC
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation, See Note 1
Ripple (20 MHz)
Noise (20 MHz)
Transient Recovery Time , See Note 3
Transient Response Deviation
Temperature Coefficient
Output Over Voltage Protection
Output Over Load Protection
Output Short Circuit
Min.
Dual Output, Balanced Loads
Vin = Min to Max
Iout = 5% to 100%
See Note 2
See Note 2
25% Load Step Change
110
120
Continuous (Autorecovery)
140
180
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
Voltage Dips
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Standard
See Note 4
EN 55022
See Note 4
EN 55022
EN 61000-4-2
EN 61000-4-3
See Note 5
EN 61000-4-4
See Note 6
EN 61000-4-5
EN 61000-4-6
EN 61000-4-29
Min.
1,500
1,000
Typ.
Max.
1,000
300
Min.
Units
VDC
M
pF
kHz
Typ.
Max.
Units
Class A
Class A
Criteria B; ±4 kV Contact
Criteria A; 10V/m
Criteria B; ±2 kV
Criteria B; ±2 kV
Criteria A; 3 Vrms
Criteria B; 0% - 70%
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Ambient
Case
Min.
-40
Typ.
-55
Free Air Convection
RH, Non-condensing
Max.
+85
+105
+125
Units
ºC
ºC
ºC
95
%
1.00 x 1.00 x 0.461 Inches (25.4 x 25.4 x 11.7 mm)
Aluminum (UL94-V0)
0.48 Oz (14g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25ºC, Gnd Benign
Min.
1.0
Typ.
Max.
Units
MHours
Conditions
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
Min.
-0.7
-0.7
Typ.
Max.
50.0
100.0
300
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
ºC
www.micropowerdirect.com
Model Selection Guide
Model
Number
MI624S-03ERU
MI624S-05ERU
MI624S-12ERU
MI624S-15ERU
MI624S-24ERU
MI624D-05ERU
MI624D-12ERU
MI624D-15ERU
MI648S-03ERU
MI648S-05ERU
MI648S-12ERU
MI648S-15ERU
MI648S-24ERU
MI648D-05ERU
MI648D-12ERU
MI648D-15ERU
Input
Voltage (VDC)
Nominal
Range
24
9.0 - 36.0
24
9.0 - 36.0
24
9.0 - 36.0
24
9.0 - 36.0
24
9.0 - 36.0
24
9.0 - 36.0
24
9.0 - 36.0
24
9.0 - 36.0
48
18.0 - 75.0
48
18.0 - 75.0
48
18.0 - 75.0
48
18.0 - 75.0
48
18.0 - 75.0
48
18.0 - 75.0
48
18.0 - 75.0
48
18.0 - 75.0
Current (mA)
Full-Load No-Load
261
7
301
7
287
7
284
7
284
7
301
7
287
7
284
7
130
3
151
3
143
3
142
3
142
3
151
3
143
3
142
3
Voltage
Output
Current
Current
(VDC)
(mA, Max)
(mA, Min)
3.3
5.0
12.0
15.0
24.0
±5.0
±12.0
±15.0
3.3
5.0
12.0
15.0
24.0
±5.0
±12.0
±15.0
1,500
1,200
500
400
250
±600
±250
±200
1,500
1,200
500
400
250
±600
±250
±200
75
60
25
20
12
±30
±12
±10
75
60
25
20
12
±30
±12
±10
Notes:
1. The load regulation of dual output units with unbalanced loads is ±5%.
2. When measuring output ripple, it is recommended that an external ceramic capacitor (approx 1 µF to 10
µF) be placed from the +Vout pin to the -Vout pin for single output units and from each output to common
for dual output units.
3. Operation at no-load will not damage these units. However, they may not meet all specifications. The
recommended minimum load is given in the model selection table above.
Typical Connection
Capacitive
Rating
Efficiency Fuse
Load
Slow-Blow
(%, Typ)
(mA)
(µF Max)
1,800
1,000
100
100
47
470
100
100
1,800
1,000
100
100
47
470
100
100
79
83
87
88
88
83
87
88
79
83
87
88
88
83
87
88
1500
1500
1500
1500
1500
1500
1500
1500
750
750
750
750
750
750
750
750
4. All units are rated for EN 55022 (CE/RE) class A without external components. They will meet class B with the addition
of the DCFM-01 (or a similar discrete filter circuit). Contact the factory for more information.
5. The external EMS components shown in the typical connection diagram are required meet EN 61000-4-4, ±2 kV.
The addition of the DCFM-01filter module will bring it to ±4 kV. Contact the factory for more information.
6. The external EMS components shown in the typical connection diagram are required meet EN 61000-4-5, ±2 kV.
This level can also be achieved with the DCFM-01filter module. Contact the factory for more information.
7. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table
above for the correct rating.
The diagram at left illustrates a typical application connection of the
MI600x-ERW series. Shown are components for external EMI and/
or EMS circuits. recommended values for the components shown are:
Output
MI624x-ERU
Fuse
Typical Board Layout: With DCFM-01 Input Module (See note at right)
MI648x-ERU
See Table Above
MOV
10D560k
LDM1
56 µH
56 µH
TVS
SMCJ48A
SMCJ90A
C1
120 µF/50V
120 µF/100V
C2
2.2 µF/50V
2.2 µF/100V
LDM2
4.7 µH
4.7 µH
CY1
1000 pF/2000V
1000 pF/2000V
CY2
1000 pF/2000V
1000 pF/2000V
10D101k
Input noise and surge suppression modules are available for a number of
MPD DC/DC converters. An MI600xERU connection with the DCFM-01/02 is
illustrated in the diagram at left. For pricing or full technical information on these
modules (DCFM-01 and DCFM-02) please contact the factory.
Pin Connections
Pin
Single
Dual
Pin
Single
Dual
1
2
+VIN
-VIN
+VIN
-VIN
3
4
5
+VOUT
No Pin
-VOUT
+VOUT
Common
-VOUT
Mechanical Dimensions
Derating Curve
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
• Pin 1 is marked by a “dot” on the top of the unit
FAX: (781) 344-8481
•
E-Mail: [email protected]