MB1500x-xxERW Datasheet

MB1500ERW
Low Cost, 1 x 2 Inch
15W, 2:1 Input Range
DC/DC Converters
Electrical Specifications
Key Features:
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
• 15W Output Power
Input
Parameter
• 2:1 Input Voltage Range
Input Voltage Range
• 1,500 VDC Isolation
• Single & Dual Outputs
Input Start Voltage
• Efficiency to 90%
• Compact 1 x 2 Inch Case
Input Filter
Start-Up Time
• -40°C to +85°C Operation
Output
• Industry Standard Pin-Out Parameter
• Low Cost
Output Voltage Accuracy
Output Voltage Balance
Output Trim Range
Line Regulation
Load Regulation
Cross Regulation
Ripple & Noise (20 MHz)
Transient Recovery Time, See Note 4
Transient Response Deviation
Output Power Protection
Temperature Coefficient
Output Short Circuit, See Note 5
Conditions
Min.
12 VDC Input
9.0
24 VDC Input 18.0
48 VDC Input 36.0
12 VDC Input
24 VDC Input
48 VDC Input
(Pi) Filter
See Note 1
Typ.
12.0
24.0
48.0
Conditions
Typ.
±1.0
±0.5
±10
±0.2
±0.5
Min.
Dual Outputs, Balanced Loads
VIN = Min to Max
IOUT = 10% to 100%
See Note 2
See Note 3
Max.
18.0
36.0
75.0
9.0
17.8
35.8
10
70
300
25% Load Step Change
±3.0
150
±0.02
Continuous (Autorecovery)
Units
VDC
VDC
mS
Max.
±3.0
±1.0
±0.5
±1.0
±5.0
100
500
±5.0
Units
%
%
%
%
%
mV P - P
µS
%
%
%/°C
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
60 Seconds
500 VDC
See Note 6
Min.
1,500
1,000
Typ.
Max.
Units
VDC
M
pF
kHz
Max.
+85
+105
+125
Units
°C
°C
°C
95
%
1,000
300
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Conditions
Ambient
Case
Min.
-40
Typ.
+25
-55
Free Air Convection
RH, Non-condensing
See Mechanical Diagram (Page 4)
Aluminum Alloy With Non-Conductive Base (UL94-V0)
0.99 Oz (28g)
Remote On/Off
Parameter
Unit On
Unit Off
Off Idle Current
Conditions
See Note 7
See Note 7
Min.
2.5
0
Typ.
Max.
12.0
1.2
Units
VDC
VDC
mA
1.0
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
1.0
Typ.
Max.
Units
MHours
Conditions
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case for 10 Sec
Min.
-0.7
-0.7
-0.7
Typ.
Max.
25.0
50.0
100.0
300
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
°C
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
MB1512S-03ERW
MB1512S-05ERW
MB1512S-12ERW
MB1512S-15ERW
MB1512S-24ERW
MB1512D-05ERW
MB1512D-12ERW
MB1512D-15ERW
MB1512D-24ERW
MB1524S-03ERW
MB1524S-05ERW
MB1524S-12ERW
MB1524S-15ERW
MB1524S-24ERW
MB1524D-05ERW
MB1524D-12ERW
MB1524D-15ERW
MB1524D-24ERW
MB1548S-03ERW
MB1548S-05ERW
MB1548S-12ERW
MB1548S-15ERW
MB1548S-24ERW
MB1548D-05ERW
MB1548D-12ERW
MB1548D-15ERW
MB1548D-24ERW
Voltage (VDC)
Nominal
12
12
12
12
12
12
12
12
12
24
24
24
24
24
24
24
24
24
48
48
48
48
48
48
48
48
48
Output
Current (mA)
Voltage
Range
Full-Load No-Load (VDC)
9.0 - 18.0
1,465
65
3.3
9.0 - 18.0
1,405
60
5.0
9.0 - 18.0
1,405
25
12.0
9.0 - 18.0
1,405
25
15.0
9.0 - 18.0
1,389
30
24.0
9.0 - 18.0
1,453
30
±5.0
9.0 - 18.0
1,420
25
±12.0
9.0 - 18.0
1,420
25
±15.0
9.0 - 18.0
1,420
20
±24.0
18.0 - 36.0
625
35
3.3
18.0 - 36.0
695
35
5.0
18.0 - 36.0
703
20
12.0
18.0 - 36.0
695
20
15.0
18.0 - 36.0
695
25
24.0
18.0 - 36.0
727
25
±5.0
18.0 - 36.0
710
20
±12.0
18.0 - 36.0
710
20
±15.0
18.0 - 36.0
710
20
±24.0
36.0 - 75.0
316
35
3.3
36.0 - 75.0
360
35
5.0
36.0 - 75.0
352
25
12.0
36.0 - 75.0
348
15
15.0
36.0 - 75.0
352
15
24.0
36.0 - 75.0
363
20
±5.0
36.0 - 75.0
355
15
±12.0
36.0 - 75.0
355
15
±15.0
36.0 - 75.0
355
15
±24.0
Notes:
1. Start up time is measured at nominal input and with a constant resistive load.
2. Cross regulation is measured with the output being tested at 50% load. The second output is varied
from 10% to 100% load.
3. When measuring output ripple, it is recommended that an external ceramic capacitor (approx 1 µF
to 10 µF) be placed from the +VOUT to the -VOUT pins.
4. Transient recovery is measured to within a 1% error band for a load step change of 25%.
5. Short circuit protection is provided by a “hiccup mode” circuit.
6. Isolation capacitance for 24 VDC output models is 2,000 pF. Isolation capacitance is measured from
input to output at 100 kHz/0.1V.
7. The maximum control current at the on/off pin (pin 6) during a logic high is 50 µA. The maximum
control current to the on/off pin at logic low (-0.7V to 0.8V) is 1 mA. If the on/off pin is left open,
the unit operates. If it is grounded, the unit will shut off.
8. These units should not be operated with a load under 10% of full load. Operation at no-load will not
damage the unit, but they may not meet all specifications.
9. These units should not be operated over +85°C. Exceeding +85°C may damage the unit.
10. It is recommended that a fuse be used on the input of a power supply for protection. See the
ModelSelection table above for the correct rating.
Efficiency
Current
Current
(mA, Max)
(mA, Min)
4,000
3,000
1,250
1,000
625
±1,500
±625
±500
±313
4,000
3,000
1,250
1,000
625
±1,500
±625
±500
±313
4,000
3,000
1,250
1,000
625
±1,500
±625
±500
±313
(%, Typ)
Over
Fuse
Voltage Capacitive
Rating
Load
Protection (µF, Max)
Slow-Blow
(VDC Typ)
200
150
63
50
32
±75
±32
±25
±16
200
150
63
50
32
±75
±32
±25
±16
200
150
63
50
32
±75
±32
±25
±16
87
89
89
89
90
86
88
88
88
88
90
89
90
90
86
88
88
88
87
87
89
90
89
86
88
88
88
3.9
6.2
15.0
18.0
30.0
±6.2
±15.0
±18.0
±30.0
3.9
6.2
15.0
18.0
30.0
±6.2
±15.0
±18.0
±30.0
3.9
6.2
15.0
18.0
30.0
±6.2
±15.0
±18.0
±30.0
(mA)
10,500
4,020
1,035
705
250
±1,020
±495
±165
±200
10,500
4,020
1,035
705
250
±1,020
±495
±165
±200
10,500
4,020
1,035
705
250
±1,020
±495
±165
±200
3,000
3,000
3,000
3,000
3,000
3,000
3,000
3,000
3,000
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,500
1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
1,000
Derating Curve
External Trim
External Trim Notes:
On single output units, an external resistor can be used to adjust the converter
output up/down by about 10%. The connection is shown in the diagram at left. The
required resistor value is calculated by the formulas:
Trim UP = RTRIM = A $-R2 - R3
R2 A
Trim Down = RTRIM = A $-R1 - R3
R1 A
Where A =
VREF
R1
VTRIM - VREF $
Where A = VTRIM VREF $R2
VREF
Where RTRIM = The value of the external trim resistor
VTRIM = The amount of voltage adjustment required
The value of R1, R2, R3 and VREF are given in the table below.
Parameter
R1 (k)
R2 (k)
R3 (k)
VREF (V)
292 Page Street Ste D Stoughton, MA 02072
3.3
4.801
2.863
15.00
1.24
5.0
2.883
2.864
10.00
2.50
Output Voltage (VDC)
9.0
12
15
7.500
10.971
14.497
2.864
2.864
2.864
15.00
17.80
17.80
2.50
2.50
2.50
24
24.872
2.864
20.00
2.50
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
EMC Specifications
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
Voltage Dips
Standard
See Note 1
EN 55022
See Note 1
EN 55022
EN 61000-4-2
EN 61000-4-3
See Note 2
EN 61000-4-4
See Note 3
EN 61000-4-5
EN 61000-4-6
EN 61000-4-29
Class A
Class A
Criteria B; ±4 kV Contact
Criteria A; 10V/m
Criteria B; ±2 kV
Criteria B; ±2 kV
Criteria A; 3 Vrms
Criteria B; 0% - 70%
Notes:
1. All units are rated for EN 55022 (CE/RE) class A without external components.
They will meet class B with the addition of the MDCFM-0x (or a similar discrete
filter circuit). Contact the factory for more information.
2. To meet the requirements of EN 61000-4-4 (±2 kV), external components are
needed. This can be done discretely, or with the addition of the MDCFM-0x.
Contact the factory for more information.
3. To meet the requirements of EN 61000-4-5 (±2 kV), external components are
needed. This can be done discretely, or with the addition of the MDCFM-0x.
Contact the factory for more information.
Typical Connection
7. In many applications simply adding input/output capacitors will
The diagram above illustrates a typical connection of the MB1500ERW 5. Recommended values for components are:
enhance the input surge
series for applications that require meeting EMC standards. The units do not Component
24 VIN
48 VIN
12 VIN
protection and reduce
require external components to operate as specified. Some notes on this
Vin
Input
Vout
Output
MOV
--S14K35
S14K60
output ripple sufficiently. The
diagram (starting with the input circuit) are:
(VDC) Capacitor (VDC) Capacitor
L1
--56 µH
56 µH
input capacitor C1 and output
1. It is recommended that an external fuse be used. The recommended fuse
3.3
470 µF
capacitors C5 and C6 shown
is shown in the model chart on page 2.
TVS
SMCJ28A
SMCJ48A
SMCJ90A
12
100 µF
5
470 µF
in the typical connection dia2. An external MOV is recommended on the input to protect the unit in the
C1
680 µF/25V
330 µF/50V
330 µF/100V
gram above (& board layout
event of a surge. A recommended value is given in the table at right.
12
220 µF
C2
1.0 µF/50V
1.0 µF/50V
1.0 µF/100V
24
100
µF
drawing below), illustrate
3. An external TVS is recommended on the input to protect the unit in the
15
220 µF
L2
4.7 µH
4.7 µH
4.7 µH
their connection. Recomevent of a voltage spike. A recommended value is given in the table at
24
100 µF
48
100 µF
C3, C4
1,000 pF/2 kV 1,000 pF/2 kV 1,000 pF/2 kV
mended capacitor values
right.
±5
±220 µF
are given in the table at right.
4. The output filtering capacitor (C5) is a high frequency, low resistance
±12
±100 µF
electrolytic capacitor. Care must be taken in choosing this capacitor not 6. Input noise and surge suppression modules are available for
±15
±100 µF
a number of MPD DC/DC power supplies. For pricing or full
to exceed the capacitive load specification for the unit. The board layout
technical information, please contact the factory.
±24
±47 µF
illustration below shows a connection for dual output units. Voltage derating
of capacitors should be 80% or above.
Typical Board Layout: With External Filter/Surge Components for Single Output Unit
Typical Connection: With External Filter/Surge Components for Dual Output Unit
MicroPower Direct
•
292 Page Street Ste D Stoughton, MA 02072
• TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: [email protected]
www.micropowerdirect.com
Mechanical Dimensions
Pin Connections
Pin
1
2
3
4
5
6
Single Output
+VIN
-VIN
+VOUT
Trim
-VOUT
Remote On/Off
Pin
1
2
3
4
5
6
Dual Output
+VIN
-VIN
+VOUT
Common
-VOUT
Remote On/Off
Adapter Plate
Mechanical Dimensions: With Optional Heatsink
All models of the MB1500x-xxERW series are available
mounted on an adapter plate similar to the one pictured at left. The
adapter plate makes it easier to mount the unit to a chassis or to a
standard DIN rail. Please contact the factory for more information.
For the heatsink option, add su
suffix “H” to the
model number (i.e. MB1524S
MB1524S-05ERW-H)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.02 (±0.50)
• Pin 1 is marked by a “dot” or indentation on the top of the unit
FAX: (781) 344-8481
•
E-Mail: [email protected]