ML300RU Series Ultra-Compact, 3W Wide 4:1 Input, SMT DC/DC Converters Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice. Key Features: • 3W Output Power • Ultra-Compact SMT Case • Wide 4:1 Input • 1,500 VDC Isolation • Single & Dual Outputs • -40ºC to +80ºC Operation • 16 Standard Models • Tight Line/Load Regulation • Available on Tape/Reel Input Parameter Conditions 24 VDC Input 48 VDC Input 24 VDC Input 48 VDC Input 24 VDC Input 48 VDC Input Max. 36.0 75.0 8.5 17.0 8.0 17.0 2,000 (Pi) Filter - Meets EN 55022 Class A Input Voltage Range Start Up Voltage Under Voltage Shutdown Short Circuit Input Power Input Filter Min. 9.0 18.0 4.5 8.5 Typ. 24.0 48.0 6.0 12.0 Units VDC VDC VDC mW Output Parameter Output Voltage Accuracy Output Voltage Balance Line Regulation Load Regulation Ripple & Noise (20 MHz) Transient Response Time, See Note 3 Transient Response Deviation Temperature Coefficient Overload Protection Output Short Circuit Conditions At 50% Load Dual Output, Balanced Loads For VIN = Min to Max For IOUT = 15% to 100% See Note 2 Min. Typ. ±1.0 ±0.5 ±0.5 50 300 25% Load Step Change ±3 ±0.01 Foldback Type 110 150 Continuous (Autorecovery) Max. ±2.0 ±2.0 ±1.0 ±1.2 100 600 ±0.02 Units % % % mV P - P µS % %/ºC % General Parameter Isolation Voltage Isolation Resistance Isolation Capacitance Switching Frequency Remote On/Off (See Note 4) Parameter Supply On Supply Off Standby Input Current Control Common Conditions 60 Seconds 500 VDC 100 kHz, 1V Conditions Min. 1,500 1,000 Typ. Max. 350 350 500 Min. 2.5 -0.7 Typ. Min. -40 Typ. Units VDC M pF kHz Max. Units 5.5 VDC 0.8 VDC 5 mA Referenced to Negative Input (pin 2) Environmental MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: [email protected] W: www.micropowerdirect.com Parameter Operating Temperature Range Operating Temperature Range Storage Temperature Range Cooling Humidity Physical Case Size Case Material Weight Conditions Ambient Case -50 Free Air Convection RH, Non-condensing Max. +80 +105 +125 Units ºC ºC ºC 95 % See Mechanical Drawing (Page 2) Non-Conductive Black Plastic (UL94-V0) 0.14 Oz (4.2g) Reliability Specifications Parameter MTBF Moisture Sensitivity Level (MSL) Conditions MIL HDBK 217F, 25ºC, Gnd Benign Min. Typ. Max. Units 300 kHours IPC/JEDEC J-STD-020D Level 2 Absolute Maximum Ratings Parameter Conditions Input Voltage Surge (1 Sec) Peak Reflow Temperature Lead Temperature 24 VDC Input 48 VDC Input See Note 5 1.5 mm From Case For 10 Sec. Min. -0.7 -0.7 Typ. Max. 50.0 100.0 245 260 Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings. www.micropowerdirect.com Units VDC ºC ºC www.micropowerdirect.com Model Selection Guide Input Model Number ML324S-03RU ML324S-05RU ML324S-12RU ML324S-15RU ML324S-24RU ML324D-05RU ML324D-12RU ML324D-15RU ML348S-03RU ML348S-05RU ML348S-12RU ML348S-15RU ML348S-24RU ML348D-05RU ML348D-12RU ML348D-15RU Voltage (VDC) Current (mA) Nominal Range Full-Load No-Load 24 9.0 - 36.0 110 30 24 9.0 - 36.0 160 30 24 9.0 - 36.0 156 30 24 9.0 - 36.0 156 30 24 9.0 - 36.0 156 30 24 9.0 - 36.0 162 30 24 9.0 - 36.0 156 30 24 9.0 - 36.0 156 30 48 18.0 - 75.0 55 20 48 18.0 - 75.0 80 20 48 18.0 - 75.0 78 20 48 18.0 - 75.0 78 20 48 18.0 - 75.0 78 20 48 18.0 - 75.0 81 20 48 18.0 - 75.0 78 20 48 18.0 - 75.0 78 20 Notes: 1. The specified maximum capacitive load is for each output. 2. When measuring output ripple, it is recommended that an external 0.47 µF ceramic capacitor be placed from +VOUT to -VOUT for single output models or from each output to common for dual output models. For noise sensitive applications, the use of 3.3 µF capacitors will reduce the output ripple. 3. Transient recovery is measured to within a 1% error band for a load step change of 75% to 100%. 4. The maximum control current at the on/off input (pin 2) during a logic high (+5V) is 400 µA. The maximum control current to the on/off pin at logic low (0V) is -400 µA. If the on/off pin is left open, the unit operates. If grounded, the unit will shut off. 5. The recommended reflow settings are a peak temperature of 245 °C for a maximum period (TPK) of 10S and a time above liquidous (TL) of <60 Output Voltage Current Current (VDC) (mA, Max) (mA, Min) 3.3 5.0 12.0 15.0 24.0 ±5.0 ±12.0 ±15.0 3.3 5.0 12.0 15.0 24.0 ±5.0 ±12.0 ±15.0 600 600 250 200 125 ±300 ±125 ±100 600 600 250 200 125 ±300 ±125 ±100 Output Rating Efficiency Capacitive Fuse Slow-Blow (%, Typ) Load (mA) (µF, Max) 90 90 38 30 19 ±45 ±19 ±15 90 90 38 30 19 ±45 ±19 ±15 75 78 80 80 80 77 80 80 75 78 80 80 80 77 80 80 300 300 300 300 300 300 300 300 150 150 150 150 150 150 150 150 220 220 47 47 47 47 47 47 220 220 47 47 47 47 47 47 Derating Curve, 3.3V & 5V Outputs seconds at 217 °C. For more information, please contact the factory. 6. Operation at no-load will not damage these units. However, they may not meet all specifications. 7. The converter should be connected to a low ac-impedance source. An input source with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied over long lines, it may be necessary to use a capacitor on the input to insure start-up. In this case, it is recommended that a low ESR (<1.0 at 100 kHz) capacitor be mounted close to the converter. For 24V input units a 4.7 µF is recommended and for 48V input models, a 2.2 µF. 8. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating. Mechanical Dimensions Derating Curve, All Other Outputs Board Layout Pin Connections Pin Single Dual 1 -VIN -VIN 2 Remote On/Off 7 NC NC 8 NC Common 9 +VOUT +VOUT 10 -VOUT -VOUT 16 +VIN +VIN NC = No connection MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 • TEL: (781) 344-8226 • Notes: • All dimensions are typical in inches (mm) • Tolerance x.xx = ±0.01 (±0.25) • Pin 1 is marked by a “dot” or indentation on the unit FAX: (781) 344-8481 • E-Mail: [email protected]