MPD G231RW

G200RW Series
Compact MiniDIP, 2W
Wide Input Range
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
• 2W Output Power
• 2:1 Input Voltage Range
• 1,500 VDC Isolation
• Short Circuit Protected
• Compact MiniDIP Case
• Single & Dual Outputs
• 1.0 MH MTBF
• Industry Standard Pin-Out
RoHS Compliant
Input
Parameter
Input Start Voltage
Input Filter
Reverse Polarity Input Current
Short Circuit Input Power
Conditions
Min.
5 VDC Input
3.5
12 VDC Input
4.5
24 VDC Input
8.0
48 VDC Input 16.0
π (Pi) Filter
Typ.
4.0
7.0
12.0
24.0
Max.
4.5
9.0
18.0
36.0
Units
1.0
1,500
A
mW
Typ.
±1.0
±1.0
±0.3
±0.5
30
Max.
±2.0
±2.0
±0.5
±0.75
50
75
15
100
±3.0
±0.01
Continuous (Autorecovery)
300
±5.0
±0.02
Units
%
%
%
%
mV P - P
mV P - P
mV rms
%
µSec
%
%/°C
VDC
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation
Ripple & Noise (20 MHz) (Note 1)
Ripple & Noise (20 MHz)
Ripple & Noise (20 MHz)
Output Power Protection
Transient Response Time (Note 2)
Transient Response Deviation
Temperature Coefficient
Output Short Circuit
Conditions
Min.
Vin = Min to Max
Iout = 25% to 100%
Over Line, Load & Temp.
120
50% Load Step Change
General
Parameter
Isolation Voltage
Isolation Test Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
60 Seconds
Flash Tested For 1 Sec
1,000 VDC
100 kHz, 1V
Min.
1,500
1,650
1,000
Typ.
Max.
250
300
420
Units
VDC
VDC
MΩ
pF
kHz
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: [email protected]
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Conditions
Min.
Typ.
-40
+25
-40
+25
-40
Free Air Convection
RH, Non-condensing
Ambient
Case
Max.
+65
+90
+125
Units
°C
°C
°C
95
%
Physical
Case Size
Case Material
Weight
0.94 x 0.54 x 0.30 Inches (23.8 x 13.7 x 7.62 mm)
Non-Conductive Black Plastic (UL94-V0)
0.18 Oz (5.1g)
Reliability Specifications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
1,000
Typ.
Max.
Units
kHours
Conditions
Min.
-0.7
-0.7
-0.7
-0.7
Typ.
Max.
11.0
25.0
50.0
100.0
260
1,800
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
5 VDC Input
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
All Models
VDC
°C
mW
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
Model Selection Guide
Model
Number
G201RW
G202RW
G203RW
G204RW
G205RW
G206RW
G207RW
G211RW
G212RW
G213RW
G214RW
G215RW
G216RW
G217RW
G221RW
G222RW
G223RW
G224RW
G225RW
G226RW
G227RW
G231RW
G232RW
G233RW
G234RW
G235RW
G236RW
G237RW
Input
Output
Reflected
Efficiency
Voltage (VDC)
Current (mA)
Ripple
Voltage Current
Current
(%, Typ)
Nominal
Range
Full-Load No-Load (VDC) (mA, Max) (mA, Min) Current (mA)
5
4.5 - 9.0
471
40
3.3
500.0
125.0
100
70
5
4.5 - 9.0
548
40
5.0
400.0
100.0
100
73
5
4.5 - 9.0
534
40
12.0
1670
42.0
100
75
5
4.5 - 9.0
582
40
15.0
134.0
33.0
100
73
5
4.5 - 9.0
667
40
±5.0
±200.0
±50.0
100
64
5
4.5 - 9.0
615
40
±12.0
±83.0
±21.0
100
69
5
4.5 - 9.0
598
40
±15.0
±67.0
±17.0
100
71
12
9.0 - 18.0
184
20
3.3
500.0
125.0
25
73
12
9.0 - 18.0
217
20
5.0
400.0
100.0
25
77
12
9.0 - 18.0
209
20
12.0
1670
42.0
25
80
12
9.0 - 18.0
220
20
15.0
134.0
33.0
25
80
12
9.0 - 18.0
242
20
±5.0
±200.0
±50.0
25
73
12
9.0 - 18.0
224
20
±12.0
±83.0
±21.0
25
78
12
9.0 - 18.0
226
20
±15.0
±67.0
±17.0
25
78
24
18.0 - 36.0
96
10
3.3
500.0
125.0
15
72
24
18.0 - 36.0
109
10
5.0
400.0
100.0
15
77
24
18.0 - 36.0
109
10
12.0
1670
42.0
15
80
24
18.0 - 36.0
108
10
15.0
134.0
33.0
15
81
24
18.0 - 36.0
119
10
±5.0
±200.0
±50.0
15
74
24
18.0 - 36.0
112
10
±12.0
±83.0
±21.0
15
78
24
18.0 - 36.0
110
10
±15.0
±67.0
±17.0
15
80
48
36.0 - 72.0
49
8
3.3
500.0
125.0
10
71
48
36.0 - 72.0
57
8
5.0
400.0
100.0
10
73
48
36.0 - 72.0
53
8
12.0
1670
42.0
10
79
48
36.0 - 72.0
55
8
15.0
134.0
33.0
10
79
48
36.0 - 72.0
62
8
±5.0
±200.0
±50.0
10
71
48
36.0 - 72.0
57
8
±12.0
±83.0
±21.0
10
77
48
36.0 - 72.0
57
8
±15.0
±67.0
±17.0
10
77
Notes:
1. When measuring output ripple, it is recommended that an external 0.47 µF ceramic
capacitor be placed from the +Vout pin to the -Vout pin for single output units and
from each output to common for dual output units. For noise sensitive applications,
the use of 3.3 µF capacitors will reduce the output ripple.
2. Transient recovery is measured to within a 1% error band for a load step change
of 75% to 100%.
3. Operation at no-load will not damage these units. However, they may not meet all
specifications.
4. Dual output units may be connected to provide a 10 VDC, 24 VDC or 30 VDC output.
To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs
and float the output common.
5. The converter should be connected to a low ac-impedance source. An input source
with a highly inductive impedance may affect the stability of the converter. In applications where the converter output loading is high and input power is supplied
over long lines, it may be necessary to use a capacitor on the input to insure startup.
In this case, it is recommended that a low ESR (ESR <1.0Ω at 100 kHz) capacitor be
mounted close to the converter. For 5V input units a 8.2 µF is recommended, for
12V input units, a 3.3 µF; and for 24V & 48V units a 1.5 µF.
6. It is recommended that a fuse be used on the input of a power supply for protection. See the table above for the correct rating.
Capacitive Load
Output (VDC)
3.3
5.0
12.0
15.0
±5.0
±12.0
±15.0
µF Max
2,200
1,000
170
110
470
100
47
Note: For dual output units,
Cap load is given for each
output.
Fuse Rating
Slow-Blow
(mA)
1,000
1,000
1,000
1,000
1,000
1,000
1,000
500
500
500
500
500
500
500
250
250
250
250
250
250
250
120
120
120
120
120
120
120
Derating Curve
Mechanical Dimensions
Pin Connections
Pin
Single
Dual
1
-Vin
-Vin
7
NC
NC
8
NC
Common
9
+Vout
+Vout
10
-Vout
-Vout
16
+Vin
+Vin
NC = No Connection
Mechanical Notes:
• All dimensions are typical in inches (mm)
• Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: [email protected]