CURRENT SENSE INDUCTORS AND TRANSFORMERS P411810 SERIES • Ideal for switching power supply applications • Peak Current Sensing: 20A and 40% Duty Cycle • Operating Frequency: 20KHz to 50KHz • Operating Temperature: -40°C to +85°C • RoHS Compliant Product • Custom Design Available ELECTRICAL PARAMETERS @25°C Part Number Inductance Turns DCR Load P411810- (mH Min) (±2% Max) (Ω MAX) (Ω) 50A 5 50 0.6 50 A 100A 20 100 1.2 100 A 200A 80 200 4.0 200 A 300A 180 300 11 300 A 50B 5 50CT 0.6 50 B Schematic 100B 20 100CT 1.2 100 B 200B 80 200CT 4.0 200 B 300B 180 300CT 11 300 B NOTES: • Inductance tested at 15.75KHz, 0.1 Vrms • Hipot: 1500Vrms Min DIMENSIONS Product performance is limited to specified parameters. Data is subject to change without prior notice. Tel: 310-325-1043 Fax: 310-325-1044 SCHEMATIC Dimensions Unless otherwise specified, all tolerances are: inch: .XX : ±0.015 .XXX : ±0.004 mm: X,X : ±0,38 X,XX : ±0,10 www.mpsind.com [email protected]