Test Report : GS25x28

 Test Report : GS25x28 25W AC/DC Green Adaptor  DESIGN VERIFY TEST
Output Function Test
Input Function Test
Protection Function Test
 SAFETY TEST
Safety Test
E.M.C Test
 RELIABILITY TEST
Other Test
GS25 series
■ DESIGN VERIFY TEST
OUTPUT FUNCTION TEST
NO
1
TEST ITEM
RIPPLE & NOISE
SPECICATION
240mVp-p (Max)
TEST CONDITION
O/P:FULL LOAD
Ta:25℃
2
VOLTAGE TOLERANCE
-2% ~ +2% (Max)
LINE REGULATION
-1% ~ +1% (Max)
LOAD REGULATION
-2% ~ +2% (Max)
SET UP TIME
500 mS (Max)
RISE TIME
30 mS (Max)
HOLD UP TIME
P
- 0% ~ + 0%
P
- 0.18% ~ + 0.25%
P
278.3 mS
P
13.7 mS
P
23.4 mS
P
I/P:230VAC
O/P:FULL LOAD
Ta:25℃
7
- 0% ~ + 0.61%
I/P:230VAC
O/P:FULL LOAD
Ta:25℃
6
P
I/P:230VAC
O/P:FULL ~MIN LOAD
Ta:25℃
5
30 mVp-p
I/P:90VAC ~264VAC
O/P:FULL LOAD
Ta:25℃
4
VERDICT
I/P:90VAC~264VAC
O/P:FULL~MIN. LOAD
Ta:25℃
3
RESULT
I/P:230VAC
15 mS (Min)
I/P:115VAC
O/P:FULL LOAD
Ta:25℃
INPUT FUNCTION TEST
NO
1
TEST ITEM
VOLTAGE RANGE
SPECICATION
100VAC ~ 240VAC (Typ)
TEST CONDITION
O/P:FULL LOAD
Ta:25℃
2
3
4
5
FREQUENCY RANGE
EFFICIENCY
AVERAGE EFFICIENCY
AC CURRENT
P
TEST: OK
P
O/P:FULL LOAD
Ta:25℃
87.28 %
P
I/P:115/230VAC
O/P:25%、50%、75%、100% LOAD
87.06 % (115VAC)
Ta:25℃
86.63 % (230VAC)
I/P: 100VAC ~ 240VAC
NO DAMAGE OSC
O/P:FULL~MIN LOAD
Ta:25℃
85.5% (Typ)
I/P:230VAC
0.7A (Max)
NO LOAD POWER
CONSUMPTION
< 0.3W
P
I/P: 100VAC
O/P:FULL LOAD
Ta:25℃
6
VERDICT
57V ~ 264V
50HZ - 60HZ (Typ)
82.35% ( LEVEL Ⅴ)
RESULT
I/P:TESTING
0.45 A
P
0.20 W
P
I/P:230VAC
O/P: NO LOAD
Ta:25℃
Model: GS25x28 Test Report
2 / 4
GS25 series
7
8
INRUSH CURRENT
LEAKAGE CURRENT
< 45A
I/P:230VAC
COLD START
O/P:FULL LOAD
Ta:25℃
< 0.75mA FOR CLASS I
I/P:240VAC
< 0.25mA FOR CLASS II
O/P:Min LOAD
Ta:25℃
35.1 A
P
L-FG: 0.02 mA
N-FG: 0.02 mA
P
PROTECTION FUNCTION TEST
NO
1
2
3
TEST ITEM
OVER LOAD PROTECTION
OVER VOLTAGE PROTECTION
SHORT PROTECTION
SPECICATION
110~150% (Typ)
TEST CONDITION
RESULT
I/P:230VAC
144 %
O/P:TESTING
Ta:25℃
HICCUP MODE
RESET AUTO RECOVER
CLAMP BY ZENER DIODE
I/P:230VAC
105 ~ 135%
O/P:MIN LOAD
Ta:25℃
CLAMP BY ZENER DIODE
SHORT EVERY OUTPUT
I/P:264VAC
NO DAMAGE
1 HOUR NO DAMAGE
O/P:FULL LOAD
Ta:25℃
HICCUP MODE
118 % (33V)
RESET AUTO RECOVER
VERDICT
P
P
P
 SAFETY & E.M.C TEST
SAFETY TEST
NO
1
TEST ITEM
WITHSTAND VOLTAGE
SPECICATION
I/P-O/P:4242VDC/min
TEST CONDITION
I/P-O/P:4242VDC/min
Ta:25℃
RESULT
I/P-O/P: 0.6 uA
NO DAMAGE
2
ISOLATION RESISTANCE
I/P-O/P:500VDC>100MΩ
I/P-O/P:500VDC
Ta:25℃
I/P-O/P:>100 MΩ
NO DAMAGE
VERDICT
P
P
E.M.C TEST
NO
1
2
3
4
TEST ITEM
HARMONIC
CONDUCTION
RADIATION
E.S.D
SPECICATION
TEST CONDITION
IEC61000-3-2
I/P:230VAC / 50HZ
CLASS A
O/P:FULL LOAD
Ta:25℃
EN55022
I/P:230VAC (50HZ)
CLASS B
O/P:FULL LOAD
Ta:25℃
EN55022
I/P:230VAC (50HZ)
CLASS B
O/P:FULL LOAD
Ta:25℃
IEC61000-4-2
I/P:230VAC/50HZ
LIGHT INDUSTRY
O/P:FULL LOAD
Ta:25℃
AIR:8KV / Contact:4KV
RESULT
VERDICT
PASS
P
PASS
P
PASS
P
CRITERIA A
P
Model: GS25x28 Test Report
3 / 4
GS25 series
5
E.F.T
IEC61000-4-4
I/P:230VAC/50HZ
LIGHT INDUSTRY
O/P:FULL LOAD
Ta:25℃
INPUT: 1KV
6
SURGE
IEC61000-4-5
I/P:230VAC/50HZ
LIGHT INDUSTRY
O/P:FULL LOAD
Ta:25℃
L-N :1KV
7
Test by certified Lab
CRITERIA A
P
CRITERIA A
P
Test Report Prepare
P
OTHER
NO
1
TEST ITEM
MTBF
SPECICATION
TEST CONDITION
RESULT
VERDICT
MIL-HDBK-217F NOTICES2 STRESS ANALYSIS PREDICTION
TOTAL FAILURE RATE: 1.43
P
M.T.B.F: 698912HRS
DATE
SAMPLE
2011.05.10
STOCK
R110428359
TEST RESULT
PASS
TESTER
APPROVAL
T.K.CHENG
VINCENT
Model: GS25x28 Test Report
4 / 4