Test Report : GS25x28 25W AC/DC Green Adaptor DESIGN VERIFY TEST Output Function Test Input Function Test Protection Function Test SAFETY TEST Safety Test E.M.C Test RELIABILITY TEST Other Test GS25 series ■ DESIGN VERIFY TEST OUTPUT FUNCTION TEST NO 1 TEST ITEM RIPPLE & NOISE SPECICATION 240mVp-p (Max) TEST CONDITION O/P:FULL LOAD Ta:25℃ 2 VOLTAGE TOLERANCE -2% ~ +2% (Max) LINE REGULATION -1% ~ +1% (Max) LOAD REGULATION -2% ~ +2% (Max) SET UP TIME 500 mS (Max) RISE TIME 30 mS (Max) HOLD UP TIME P - 0% ~ + 0% P - 0.18% ~ + 0.25% P 278.3 mS P 13.7 mS P 23.4 mS P I/P:230VAC O/P:FULL LOAD Ta:25℃ 7 - 0% ~ + 0.61% I/P:230VAC O/P:FULL LOAD Ta:25℃ 6 P I/P:230VAC O/P:FULL ~MIN LOAD Ta:25℃ 5 30 mVp-p I/P:90VAC ~264VAC O/P:FULL LOAD Ta:25℃ 4 VERDICT I/P:90VAC~264VAC O/P:FULL~MIN. LOAD Ta:25℃ 3 RESULT I/P:230VAC 15 mS (Min) I/P:115VAC O/P:FULL LOAD Ta:25℃ INPUT FUNCTION TEST NO 1 TEST ITEM VOLTAGE RANGE SPECICATION 100VAC ~ 240VAC (Typ) TEST CONDITION O/P:FULL LOAD Ta:25℃ 2 3 4 5 FREQUENCY RANGE EFFICIENCY AVERAGE EFFICIENCY AC CURRENT P TEST: OK P O/P:FULL LOAD Ta:25℃ 87.28 % P I/P:115/230VAC O/P:25%、50%、75%、100% LOAD 87.06 % (115VAC) Ta:25℃ 86.63 % (230VAC) I/P: 100VAC ~ 240VAC NO DAMAGE OSC O/P:FULL~MIN LOAD Ta:25℃ 85.5% (Typ) I/P:230VAC 0.7A (Max) NO LOAD POWER CONSUMPTION < 0.3W P I/P: 100VAC O/P:FULL LOAD Ta:25℃ 6 VERDICT 57V ~ 264V 50HZ - 60HZ (Typ) 82.35% ( LEVEL Ⅴ) RESULT I/P:TESTING 0.45 A P 0.20 W P I/P:230VAC O/P: NO LOAD Ta:25℃ Model: GS25x28 Test Report 2 / 4 GS25 series 7 8 INRUSH CURRENT LEAKAGE CURRENT < 45A I/P:230VAC COLD START O/P:FULL LOAD Ta:25℃ < 0.75mA FOR CLASS I I/P:240VAC < 0.25mA FOR CLASS II O/P:Min LOAD Ta:25℃ 35.1 A P L-FG: 0.02 mA N-FG: 0.02 mA P PROTECTION FUNCTION TEST NO 1 2 3 TEST ITEM OVER LOAD PROTECTION OVER VOLTAGE PROTECTION SHORT PROTECTION SPECICATION 110~150% (Typ) TEST CONDITION RESULT I/P:230VAC 144 % O/P:TESTING Ta:25℃ HICCUP MODE RESET AUTO RECOVER CLAMP BY ZENER DIODE I/P:230VAC 105 ~ 135% O/P:MIN LOAD Ta:25℃ CLAMP BY ZENER DIODE SHORT EVERY OUTPUT I/P:264VAC NO DAMAGE 1 HOUR NO DAMAGE O/P:FULL LOAD Ta:25℃ HICCUP MODE 118 % (33V) RESET AUTO RECOVER VERDICT P P P SAFETY & E.M.C TEST SAFETY TEST NO 1 TEST ITEM WITHSTAND VOLTAGE SPECICATION I/P-O/P:4242VDC/min TEST CONDITION I/P-O/P:4242VDC/min Ta:25℃ RESULT I/P-O/P: 0.6 uA NO DAMAGE 2 ISOLATION RESISTANCE I/P-O/P:500VDC>100MΩ I/P-O/P:500VDC Ta:25℃ I/P-O/P:>100 MΩ NO DAMAGE VERDICT P P E.M.C TEST NO 1 2 3 4 TEST ITEM HARMONIC CONDUCTION RADIATION E.S.D SPECICATION TEST CONDITION IEC61000-3-2 I/P:230VAC / 50HZ CLASS A O/P:FULL LOAD Ta:25℃ EN55022 I/P:230VAC (50HZ) CLASS B O/P:FULL LOAD Ta:25℃ EN55022 I/P:230VAC (50HZ) CLASS B O/P:FULL LOAD Ta:25℃ IEC61000-4-2 I/P:230VAC/50HZ LIGHT INDUSTRY O/P:FULL LOAD Ta:25℃ AIR:8KV / Contact:4KV RESULT VERDICT PASS P PASS P PASS P CRITERIA A P Model: GS25x28 Test Report 3 / 4 GS25 series 5 E.F.T IEC61000-4-4 I/P:230VAC/50HZ LIGHT INDUSTRY O/P:FULL LOAD Ta:25℃ INPUT: 1KV 6 SURGE IEC61000-4-5 I/P:230VAC/50HZ LIGHT INDUSTRY O/P:FULL LOAD Ta:25℃ L-N :1KV 7 Test by certified Lab CRITERIA A P CRITERIA A P Test Report Prepare P OTHER NO 1 TEST ITEM MTBF SPECICATION TEST CONDITION RESULT VERDICT MIL-HDBK-217F NOTICES2 STRESS ANALYSIS PREDICTION TOTAL FAILURE RATE: 1.43 P M.T.B.F: 698912HRS DATE SAMPLE 2011.05.10 STOCK R110428359 TEST RESULT PASS TESTER APPROVAL T.K.CHENG VINCENT Model: GS25x28 Test Report 4 / 4