TKA30 series

TKA30 series
DC-DC Module Type Triple Output Converter
Model : TKA30B-B
25W
V1 : +5V / 350~3500mA
V2 : +12V / 31~310mA
V3 : -12V / 31~310mA
OUTPUT FUNCTION TEST
NO
1
2
3
4
TEST ITEM
OUTPUT VOLTAGE ACCURACY
RIPPLE & NOISE
LINE REGULATION
LOAD REGULATION
SPECICATION
TEST CONDITION
V1:-2%~+2%
I/P: 24VDC
V2:-5%~+5%
V3:-5%~+5%
O/P:50% LOAD
Ta:25℃
V1:100mVp-p
I/P:24VDC
V2:100mVp-p
V3:100mVp-p
O/P:FULL LOAD
Ta:25℃
V1:-0.5%~+0.5%
I/P:18VDC ~36VDC
V2:-1.0%~+1.0%
V3:-1.0%~+1.0%
O/P:FULL LOAD
Ta:25℃
V1:-2%~+2%
I/P:24VDC
V2:-5%~+5%
O/P:FULL ~MIN LOAD
Ta:25℃
V3:-5%~+5%
RESULT
VERDICT
V1: -0.2%
V2: +2.75%
P
V3: +2.3%
V1: 45mVp-p
V2: 38mVp-p
P
V3: 36mVp-p
V1: -0%~+0%
V2: -0.1%~+0%
P
V3: -0.1%~+0%
V1: -0.2%~+0%
V2: -0.16%~+0.16%
P
V3: -0.24%~+0.24%
INPUT FUNCTION TEST
NO
1
TEST ITEM
INPUT VOLTAGE RANGE
SPECICATION
18VDC~36VDC (Typ)
TEST CONDITION
O/P:FULL LOAD
Ta:25℃
2
EFFICIENCY
82% (Typ)
INPUT CURRENT
VERDICT
10.5~36VDC
P
85.6%
P
I/P:24VDC
O/P:FULL LOAD
Ta:25℃
3
RESULT
I/P:TESTING
1.27A (Typ.) FULL LOAD
I/P:24VDC
18mA (Typ.) NO LOAD
O/P:NO / FULL LOAD
Ta:25℃
1.22A / FULL LOAD
18mA / NO LOAD
P
PROTECTION FUNCTION TEST
NO
1
2
TEST ITEM
OVER LOAD PROTECTION
SHORT PROTECTION
SPECICATION
110% ~ 250%
TEST CONDITION
RESULT
I/P:24VDC
122%
O/P:TESTING
Ta:25℃
HICCUP MODE
SHORT EVERY OUTPUT
I/P:36VDC
NO DAMAGE
1 HOUR NO DAMAGE
O/P:FULL LOAD
Ta:25℃
HICCUP MODE
AUTO-RECOVER
AUTO-RECOVER
VERDICT
P
P
Model: TKA30B-B Test Report
1 / 2
TKA30 series
DC-DC Module Type Triple Output Converter
CONTROL FUNCTION TEST
NO
1
TEST ITEM
REMOTE CONTROL
SPECICATION
TEST CONDITION
Power on :
R.C >4.5~5.5V or open
Power off :
RESULT
I/P:24VDC
Power on :
O/P:FULL LOAD
Ta:25℃
Power off :
R.C <0.8V or short (-Vin)
R.C>3.7Vdc OR Open
VERDICT
P
R.C<3.0Vdc OR Short
SAFETY TEST
NO
1
2
TEST ITEM
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
SPECICATION
I/P-O/P:1000 VDC/min
I/P-O/P:500VDC>100MΩ
TEST CONDITION
RESULT
I/P-O/P:1000 VDC/min
Ta:25℃
I/P-O/P: 0.02mA
I/P-O/P:500 VDC
Ta:25℃
I/P-O/P>100MΩ
NO DAMAGE
NO DAMAGE
VERDICT
P
P
E.M.C TEST
NO
1
2
3
TEST ITEM
RADIATION
E.S.D
E.F.T
SPECICATION
I/P:24VDC
CLASS A
O/P:FULL LOAD
Ta:25℃
IEC61000-4-2
I/P:24VDC
LIGHT INDUSTRY
AIR:8KV / Contact:4KV
O/P:FULL LOAD
Ta:25℃
IEC61000-4-4
I/P:24VDC
LIGHT INDUSTRY
O/P:FULL LOAD
Ta:25℃
INPUT: 0.5KV
4
SURGE
WITHSTAND VOLTAGE
RESULT
P
CRITERIA A
P
CRITERIA A
P
P
I/P:24VDC
LIGHT INDUSTRY
O/P:FULL LOAD
Ta:25℃
CRITERIA A
I/P-O/P:1KVDC/min
Ta:25℃
I/P-O/P:0.002mA
I/P-O/P:1KVDC/min
NO DAMAGE
6
ISOLATION RESISTANCE
I/P-O/P:500VDC>100MΩ
I/P-O/P:500VDC
Ta:25℃
I/P-O/P:>100MΩ
NO DAMAGE
DATE
SAMPLE
2008.8.15
TKA30B-B
TEST RESULT
PASS
VERDICT
PASS
IEC61000-4-5
L-L :0.5KV
5
TEST CONDITION
EN55022
P
P
TESTER
APPROVAL
PETER
T.K.CHENG
Model: TKA30B-B Test Report
2 / 2