IRC1 / IRC2 / IRC3 Instruction Manual

IRC1 / IRC2 / IRC3
Instruction Manual
IRC1 / IRC2 / IRC3 Instruction Manual
1. Product description
1.1 Product introduction:
IRC1 is a simple remote control device which can be used with TS-700/1000/1500/3000 & TN-1500/3000. The built-in
ON/OFF button allows remote ON/OFF of the inverter's output and power saving mode. The controller panel also shows
inverter's working conditions such as Remote ON/OFF, abnormal, and power saving mode.
IRC2 is a remote control device which can be used with TS-700/1000/1500/3000. Besides the control functions found in IRC1,
it also has indications for battery capacity percentage and load percentage. This device is suitable for end users who need
more information feedback from the inverter.
IRC3 is a complete remote control device which can be used with TN-1500/3000 with solar charging function. The display
found on the TN-1500/3000 unit is completely replicated onto the remote device. Besides the control functions found on
IRC1/IRC2, IRC3 displays solar charging, AC charging, and whether the load is supplied by AC utility or inverter. Thus,
allowing user to fully understand the solar inverter's current state.
To satisfy different demands for remote control distances, the RC device can be matched with 3 types of cable length, 10ft
cable (standard), or 25ft / 50ft (optional).
1.2 Product features:
Push ON/OFF button can be used to turn the output of the inverter ON or OFF and setting the power saving function enable or
disable.
LED indications for inverter status.
2 installation methods. Mount on top of a vertical surface or inside system panel.
3 cable length available (10ft / 25ft / 50ft).
Compliance to FCC / CE.
3 years warranty.
2. Diagram of device panel and explanation of operating status
2.1 IRC1 panel and explanation of LED indication:
LED
indication
Status
description
Green
Red
Orange
Orange Flash
Remote ON
Abnormal
Remote OFF
Power saving
mode
A
Green
Orange
Red
Orange Flash
:
:
:
:
B : Push ON/OFF button
ON
OFF
Abnormal
Power Saving
Model No : IRC1
Inverter Remote Controller
PUSH
ON / OFF
A : LED indicator
B
IRC1 panel
2.2 IRC2 panel and explanation of LED indication:
LED
indication
Status
description
Green
Red
Orange
Orange Flash
Remote ON
Abnormal
Remote OFF
Power saving
mode
E
BATTERY
100%
INVERTER
100%
Green : ON
Orange : OFF
LOAD Red : Abnormal
Orange Power
:
Flash Saving
A
B : Push ON/OFF button
C
D
0%
A : LED indicator
C : Load indicator
0%
D : Battery capacity indicator
Model No : IRC2
Inverter Remote Controller
PUSH
ON / OFF
B
E : Inverter providing load
IRC2 panel
1
2.2.1 Explanation of abnormal conditions:
Status description
Load indicator
Load indicator
Status description
LOAD
LOAD
Output OLP
(>115%)
Output OLP
(>105%)
Status description
Load indicator
Load indicator
Status description
LOAD
LOAD
Output OLP
(>150%)
OTP
Status description
Load indicator
Load indicator
Status description
LOAD
LOAD
Abnormal output
voltage level
Output short
protection
Status description
Load indicator
Load indicator
Status description
LOAD
LOAD
Battery input
UVP/OVP
Battery fail protection
(Battery aged)
Status description
Load indicator
LOAD
Fan lock protection
2.2.2 Explanation for Remote off:
Status description
Load indicator
LOAD
Remote OFF
2.2.3 Explanation of battery capacity level:
BATTERY
BATTERY
25%
100%
~
<25%
BATTERY
50%
100%
>75%
75%
50%
0%
100%
~
BATTERY
100%
0%
0%
0%
2.2.4 Explanation of load condition:
LOAD
LOAD
25%
100%
~
<25%
LOAD
50%
100%
>75%
75%
50%
0%
100%
~
LOAD
100%
0%
0%
0%
2.3 IRC3 panel and explanation of LED indication:
LED
indication
Status
description
G
Green
Red
Orange
Orange Flash
Remote ON
Abnormal
Remote OFF
Power saving
mode
F
A : LED indicator
E
B : Push ON/OFF button
SOLAR CHARGE
BATTERY
100%
D
INVERTER
100%
Green : ON
Orange : OFF
LOAD Red : Abnormal
Orange Power
:
Flash Saving
E : Inverter providing load
I I
0%
I
AC IN
H
C : Load indicator
D : Battery capacity indicator
C
BY PASS
0%
A
Model No : IRC3
Inverter Remote Controller
PUSH
ON / OFF
B
F : Solar charger ON/OFF
G : AC charger ON/OFF
H : AC utility normal
IRC3 panel
I I
AC
CHARGE
I : AC utility providing load
2
2.3.1 Explanation of abnormal conditions:
Status description
Load indicator
Load indicator
Status description
LOAD
LOAD
Output OLP
(>115%)
Output OLP
(>105%)
Status description
Load indicator
Load indicator
Status description
LOAD
LOAD
Output OLP
(>150%)
OTP
Status description
Load indicator
Load indicator
Status description
LOAD
LOAD
Abnormal output
voltage level
Status description
Load indicator
Output short
protection
Load indicator
Status description
LOAD
LOAD
Battery input
UVP/OVP
Battery fail protection
(Battery aged)
Status description
Load indicator
LOAD
Fan lock protection
2.3.2 Explanation for Remote off:
Load indicator
Status description
LOAD
Remote OFF
2.3.3 Explanation of battery capacity level:
BATTERY
100%
100%
0%
100%
>75%
75%
50%
0%
BATTERY
50%
~
<25%
BATTERY
25%
~
BATTERY
100%
0%
0%
2.3.4 Explanation of load condition:
LOAD
100%
100%
0%
100%
>75%
75%
50%
0%
LOAD
50%
~
<25%
LOAD
25%
~
LOAD
100%
0%
0%
2.3.5 AC and solar charging status:
AC CHARGE
SOLAR CHARGE
AC charger
working
AC CHARGE
AC charger
working
SOLAR CHARGE
AC charger OFF
Solar charger
OFF
3. Operating instructions
3.1 Accessories:
a.IRC1/2/3 remote controller.
b.RJ-11 ~ RJ-11 10ft cable (standard), 25ft / 50ft cable (optional).
10ft / 25ft / 50ft
1
6
6
1
Phone Jack
RJ-11
Do not use ordinary telephone line
available on the market
Phone Jack
RJ-11
3
c.Screw set (M4 combination of screw & washer + nuts x 2 sets).
d.User's manual
1.
3.2 Installation method:
(1)Mount on top of a vertical surface
M3
(2)Mount inside system panel
M4
3.3 Cable connection:
Please use the provided cable when connecting the controller device to the jack found on the front panel of the inverter. Refer to
the diagram below:
SOLAR CHARGE
AC
CHARGE
BATTERY
100%
INVERTER
100%
Green : ON
Orange : OFF
LOAD Red : Abnormal
Orange : Power
Flash Saving
BY PASS
0%
0%
AC IN
Model No : IRC3
Inverter Remote Controller
PUSH
ON / OFF
3.4 Description of available functions:
IRC1/2/3 can be used to remotely control inverter ON/OFF and enable or disable the power saving mode. After attaching the
RJ11~RJ11 cable, all the LEDs on the device panel will light up, after waiting for about 5 seconds then the control process can
begin. No external power source is required for the controller.
3.4.1 Remotely control inverter ON/OFF:
After pushing the ON/OFF setting button, the inverter will immediately shut down. The load indicator will also reflect this
change in status. To restart the inverter, press the setting button again.
3.4.2 Remotely enable or disable the power saving mode:
This controller offers flexible adjustment of the standby mode, enable or disable. The operating sequence is as follows, press
and hold on to the push ON/OFF button for about 3 seconds and the LED indicator will start flashing orange. Enter setting
mode after letting go of the push ON/OFF button. Power saving mode can be enable or disable by pressing the push ON/OFF
button. Check for setting status by inspection LED indication (refer to the chart below). After making your selection, hold on
to the push ON/OFF button for 5 seconds and the LED indicator will flash orange, let go of the push ON/OFF button and the
inverter will automatically restart to complete the setting sequence.
LED indicator
Green
Red
Status description Enable power saving mode Disable power saving mode
4.Cautionary notes
If the inverter goes into protection due to abnormal operating condition and cannot be restarted using the controller unit, please go on
site to correct inverter failure condition and then resume remote operation.
4
5.Failure correction
Probable cause
Possible solution
Improper wiring
connection
Please use the provided cable
accessory
(Do not use ordinary telephone line)
Loose wiring connection
Please make sure the connectors
on the cables are attached securely
to the jacks
Inverter not ON
Please make sure the inverter
is switched ON
Can not set
power saving
mode
Operational error
Please refer to 3.4.2 for more
details
RC ON/OFF not
operational
Inverter is abnormal
Check inverter status and clear
abnormal condition
Failure condition
LED indicator
OFF
6.Warranty
6.1 Two years of free repair service is provided when the controller device is operated under normal operating conditions.
Please do not change components or modify or repair the unit by yourself or else Mean Well reserves the right to void
product warranty.
6.2 This is a class A product. In a domestic environment this product may cause radio interference in which case the user
may be required to take adequate measures.
5