HER106

MOSPEC
HER106 Thru HER108
Switchmode Power Rectifiers
ULTRAFAST
RECTIFIERS
Designed for use in switching power supplies. inverters and as free
wheeling diodes. These state-of-the-art devices have the following features:
1.0 AMPERES
600-1000 VOLTS
*High Surge Capacity
*Low Power Loss, High efficiency
*Glass Passivated chip junctions
*150℃ Operating Junction Temperature
*Low Stored Charge Majority Carrier Conduction
*Low Forward Voltage , High Current Capability
*Ultrafast 100 Nanosecond Recovery Time
*Plastic Material used Carries Underwriters Laboratory
Flammability Classification 94V-O
Plating pb free
The marking is indicated by part no. add.“M”.
ex:HER106M~HER108M
DO-41
MAXIMUM RATINGS
Characteristic
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
RMS Reverse Voltage
Average Rectifier Forward Current
Non-Repetitive Peak Surge Current
(Surge applied at rate load conditions
halfware, single phase,60Hz )
Symbol
HER106
HER107
HER108
Unit
VRRM
VRWM
VR50
600
800
1000
V
VR(RMS)
420
560
700
V
IO
1.0
IFSM
30
A
A
DIM
Operating and Storage Junction
Temperature Range
TJ , TSTG
ELECTRIAL CHARACTERISTICS
Characteristic
Symbol
HER106
HER107
HER108
Unit
Maximum Instantaneous Forward Voltage
(IF=1.0 Amp, TC = 25℃)
VF
Maximum Instantaneous Reverse Current
(Rated DC Voltage, TC = 25℃)
(Rated DC Voltage, TC = 125℃)
IR
5.0
50
uA
Reverse Recovery Time
( IF = 0.5 A, IR =1.0 , Irr =0.25 A )
Trr
100
ns
Typical Junction Capacitance
(Reverse Voltage of 4 volts & f=1 MHz)
CP
1.75
1.50
15
10
MIN
MAX
A
2.00
2.70
B
25.40
C
4.10
5.20
D
0.70
0.90
℃
-65 to +150
MILLIMETERS
V
PF
CASE--Transfer molded
plastic
POLARITY--Cathode indicated
polarity band
HER106 Thru HER108
FIG-3 FORWARD CURRENT DERATING CURVE
HER106
HER108
HER107
AVERAGE FORWARD RECTIFIED CURRENT (Amp.)
AVERAGE FORWARD RECTIFIED CURRENT (Amp.)
FIG-1 TYPICAL FORWARD CHARACTERISITICS
LEAD TEMPERATURE (℃)
FIG-4TYPICAL JUNCTION CAPACITANCE
HER106
HER107-HER108
REVERSE VOLTAGE (Volts.)
HER108
FIG-5PEAK FORWARD SURGE CURRENT
HER106-HER107
PERCENT OF PEAK REVERSE VOLTAGE (﹪)
PEAK FORWARD SURGE CURRENT (Amp.)
INSTANTANEOUS REVERSE CURRENT (Amp.)
FIG-2 TYPICAL REVERSE CHARACTERISTICS
JUNCTION CAPACITANCE (PF)
FORWARD VOLTAGE (Volts)
NUMBER OF CYCLES AT 60 Hz
Set time base for 20/50 ns/cm