SFP-GD-BD34 Datasheet

Optical Communications Systems™
Datasheet
1.25 Gbps Single Fiber 38 km Bidirectional SFP Transceivers
SFP-GD-BD34 and SFP-GD-BD43
Highlights
SFP transceiver
Data Rate: 1.25 Gbps
Protocol:
- Gigabit Ethernet
Single-mode fiber
Single fiber, bi-directional
Two wavelength models (for use in pairs)
- Tx = 1310nm, Rx = 1490nm (SFP-GD-BD34)
- Tx = 1490nm, Rx = 1310nm (SFP-GD-BD43)
12 to 38 km
Simplex LC connector
Digital Diagnostics (SFF-8472)
Hot-swap
Industrial temperature models available
Overview
Small Form-Factor Pluggable (SFP) interfaces from MRV Communications provide flexible high speed links in a small
industry standard package. They deliver the deployment options and inventory control that network administrators
demand for growing networks.
SFPs are designed to Multi-Source Agreement (MSA) standards to ensure network equipment compatibility. They are a
perfect addition to MRV ‘s extensive lines of networking equipment.
Visit the MRV website at www.mrv.com or contact your nearest authorized MRV Communications dealer for more
information.
Specifications Overview
Data Rate
Tx Wavelength:
1.25 Gbps
SFP-GD-BD34
1310 nm
SFP-GD-BD43
1490 nm
Tx Power (Minimum)
-5 dBm
Tx Disable
Rx Wavelength:
Yes
SFP-GD-BD34
1480 to 1500 nm
SFP-GD-BD43
1260 to 1360 nm
Rx Sensitivity
-24 dBm
Rx Saturation
-3 dBm
Rx Damage Threshhold
0 dBm
Operating Temperature Range
-5 to 70 ºC
Operating Temperature Range (TH Models)
-40 to 85 ºC
Power Consumption
1 Watt
1
Optical Communications Systems™
Datasheet
Transmitter Specifications (Optical)
Parameter
Symbol
Min
Max
Unit
-5
0
dBm
-
Optical Crosstalk
Pop
XT
-
-40
dB
-
Average Launch Power Tx_Off
Poff
-
-45
dBm
-
ER
9
-
dB
-
tr/ tf
λ
-
260
ps
-
1260
1360
nm
-
Optical Power
Extinction Ratio
Eye Mask
Notes
Compliant with IEEE 802.3ah
Optical Rise/Fall Time (20%~80% values)
Wavelength for SFP-GD-BD34
Wavelength for SFP-GD-BD43
λ
1480
1500
nm
Relative Intensity Noise
RIN
-
-120
dB/Hz
-
Transmitter Reflectance
-
-
-12
dB
-
Reflection Tolerance
rp
-
12
dB
-
Receiver Specifications (Optical)
Parameter
Symbol
Min
Max
Unit
Notes
Receiver Power Low
Rsens,low
-
-24
dBm
1
Receiver Power High
Rsens,high
-3
-
dBm
1
Pin, damage
λ
0
-
dBm
-
1480
1500
nm
-
Damage Threshold For Receiver
Wavelength for SFP-GD-BD34
Wavelength for SFP-GD-BD43
λ
1260
1360
nm
-
Receiver Reflectance
RX_r
-
-12
dB
-
LOS Assert
-45
-
dBm
-
LOS De-assert
LOSA
LOSD
-
-24
dBm
-
LOS Hysteresis
-
0.5
-
dB
-
Notes:
1.
Measured at 10-12 BER, PRBS 2-7-1
Digital Diagnostics
Parameter
Range
Accuracy
Unit
Calibration
Formula
Temperature
-5 to 70
±3
ºC
External
Tc(C) = Tslope*Tad (16 bit signed twos complement value) + Toffset
Temperature (TH Models)
-40 to 85
±3
ºC
External
Tc(C) = Tslope*Tad (16 bit signed twos complement value) + Toffset
Voltage
0 to Vcc
± 0.1
V
External
V(Volts) = Vslope*Vad (16 bit unsigned integer) + Voffset
Bias Current
0 to 120
±5
mA
External
I(mA) = Islope * Iad (16 bit unsigned integer) + Ioffset
TX Power
-5 to 0
± 3 dB
dBm
External
Tx_PWR(μW) = Tx_PWRslope*Tx_PWRad (16 bit unsigned integer)
+ Tx_PWRoffset
RX Power
-24 to -3
± 3 dB
dBm
External
RX_PWR(μW)=A0+A1*x+A2*x^2+A3*x^3+A4*x^4
2
Optical Communications Systems™
Datasheet
General Operating Conditions
Parameter
Symbol
Min.
Max.
Unit
Notes
Supply Voltage
Vcc
3.135
3.465
V
-
Total Current
Icc
-
300
mA
-
Power Supply Noise Rejection
PSR
100
-
mVp-p
-
Operating Case Temperature
Topr
-5
70
ºC
-
Operating Case Temperature (TH Models)
Topr
-40
85
ºC
-
Storage Temperature
Tstg
-40
85
ºC
-
Data Rate
DR
-
1250
Mbps
-
Symbol
Min.
Max.
Unit
Notes
Rin
80
120
Ω
-
PECL Single Ended Data Input Swing
Vin, p-p
250
1200
mV
-
TxFault_Fault
Vfault
2
Vcc
V
-
Vnormal
Vee
Vee + 0.5
V
-
Transmitter Specifications (Electrical)
Parameter
Input Differential Impedence
TxFault_Normal
TxDisable_Disable
Vd
2
Vcc
V
-
TxDisable_Enable
Ven
Vee
Vee + 0.8
V
-
Parameter
Symbol
Min.
Max.
Unit
Notes
PECL Single Ended Data Output Swing
Vout, p-p
185
800
mV
-
tr, tf
-
500
ps
-
Symbol
Min
Max
Unit
Notes
Receiver Specifications (Electrical)
Data Output Rise/Fall Time
Electrical Specifications and Timing
Parameter
Tx Disable Negate Time
t_on
-
1
ms
-
Tx Disable Assert Time
t_off
-
10
μs
-
Time to Initialize, Including Reset of Tx Fault
t_init
-
300
ms
-
Tx Fault Assert Time
t_fault
-
100
μs
-
Tx Disable to Reset
t_reset
10
-
μs
-
LOS Assert Time
t_loss_on
-
100
μs
-
LOS De-Assert Time
t_loss_off
-
100
μs
-
Serial ID Clock Rate
f_serial_clock
-
100
kHz
-
RX_LOS Voltage (High)
Rx_LOSH
2
-
V
RX_LOS Voltage (Low)
Rx_LOSL
-
0.8
V
-
LOS Output Voltage-Fault
VLOSfault
2
Vcc
V
-
VLOSnormal
Vee
Vee + 0.5
V
-
MOD_DEF (0:2)-High
LOS Output Voltage-Normal
VH
2
Vcc
V
-
MOD_DEF (0:2)-Low
VL
Vee
Vee + 0.5
V
-
3
Optical Communications Systems™
Datasheet
Pin
Function
Name / Description
Notes
1
VeeT
Transmitter Ground
-
2
TX_FAULT
Open Collector
3
TX_DISABLE
Internally Pulled High
-
4
MOD_DEF2
Serial Data Input
-
5
MOD_DEF1
Serial Clock Input
-
6
MOD_DEF0
Internally Grounded
-
7
NC
Not Connected
-
8
LOS
Open Collector
-
9
VeeR
Receiver Ground
-
10
VeeR
Receiver Ground
-
11
VeeR
Receiver Ground
-
12
RXD-
Receiver Data Negative
-
13
RXD+
Receiver Data Positive
-
14
VeeR
Receiver Ground
-
15
VccR
Receiver Power
-
16
VccT
Transmitter Power
17
VeeT
Transmitter Ground
-
18
TXD+
Transmitter Data Positive
-
19
TXD-
Transmitter Data Negative
-
20
VeeT
Transmitter Ground
-
Outline Drawing
Units in mm (inch)
4
Optical Communications Systems™
Datasheet
Bail Latch
Color
Distance
Range
(km)
SFP Bidirectional Transceiver Single Fiber,
Single-Mode with Digital Diagnostics
1.25
1310
1490
Simplex LC
Blue
12 - 38
SFP-GD-BD34TH
SFP Bidirectional Transceiver Single Fiber,
Single-Mode with Digital Diagnostics,
Temperature Hardened
1.25
1310
1490
Simplex LC
Blue
12 - 38
SFP-GD-BD43
SFP Bidirectional Transceiver Single Fiber,
Single-Mode with Digital Diagnostics
1.25
1490
1310
Simplex LC
Purple
12 - 38
SFP-GD-BD43TH
SFP Bidirectional Transceiver Single Fiber,
Single-Mode with Digital Diagnostics,
Temperature Hardened
1.25
1490
1310
Simplex LC
Purple
12 - 38
Data Rate
(Gbps)
SFP-GD-BD34
Model
Connector
Type
Wavelength
(nm)
Description
Ordering Information
Tx
Rx
Regulatory and Industry Compliances
Class 1 Laser Product, complies with EN 60825-1 and 21 CFR 1040.10 except for deviations pursuant to Laser Notice No. 50. dated June 24, 2007
MSA SFF-8074i; Telcordia GR-468, Digital Diagnostic SFF-8472;
Certified by one or more of the following agencies: TÜV, UL, CSA
RoHS Directive; China RoHS; California RoHS Law, REACH Directive SVHC; WEEE Directive
The Quality Management System is certified to ISO 9001 by QMI-SAI Global
The Environmental Management System is in compliance with ISO 14001
Warnings
Handling Precautions: This device is susceptible to damage as a result of electrostatic descharge (ESD). A static free environment is highly
recommended. Follow guidelines according to proper ESD procedures.
Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation.
MRV has more than 50 offices throughout the world. Addresses, phone numbers and fax numbers are listed at www.mrv.com.
Please e-mail us at [email protected] or call us for assistance.
MRV Los Angeles
20415 Nordhoff Street
Chatsworth, CA 91311
800-338-5316
818-773-0900
MRV Boston
300 Apollo Drive
Chelmsford, MA 01824
800-338-5316
978-674-6800
MRV International
Business Park Moerfelden
Waldeckerstrasse 13
64546 Moerfelden-Walldorf
Germany
Tel. (49) 6105/2070
Fax (49) 6105/207-100
All statements, technical information, and recommendations related to the products herein are based upon information believed to be reliable or accurate. However, the
accuracy or completeness thereof is not guaranteed, and no responsibility is assumed for any inaccuracies. Please contact MRV Communications for more information.
MRV Communications and the MRV Communications logo are trademarks of MRV Communications, Inc. Other trademarks are the property of their respective holders.
MRV-OP-SFPGDBD3443-102510
3020108-001 Rev. A3