Datasheet OptiSwitch® 606 - FE/GE Network Interface Device Product Highlights Compact 1RU 9’’ form factor for space saving MEF CE 2.0 Services Compliant Non-blocking hardware architecture - 4 x 10/100/1000Base-T RJ45 ports + 2 x 100/1000FX SFP ports - All interfaces can be configured as UNI / NNI - Support for jumbo frames on all ports OS606 MRV’s OptiSwitch® 606 (OS606) is a highly price-competitive Carrier-Ethernet (CE) FE/GE Network Interface Device (NID) used to provide cost-effective mass deployment of 10 Mbps, 100 Mbps, and 1 Gbps MEF-based Ethernet services at customer premises with guaranteed SLAs. Architectured for graded enhancement and expansion, the OS606 is a choice candidate in the “pay-as-you-grow” business model. Small Office-Home Office (SOHO) customers provided with access to an Ethernetbased cloud of services strongly tend to opt for medium bandwidths with simple SLAs that may include just protection and minimal service monitoring capabilities. In order to optimize services to these customers while allowing for their future demands for more bandwidth and advanced services, the OS606 offers service providers with two growth paths implemented by software alone: 1) Added mechanisms/features/ capabilities, and 2) Increased service port speeds. The OS606 meets MEF 9, 14, 17, and 21 specifications, and provides for easy deployment and management while maintaining full interoperability and guaranteed SLAs. As a small form factor unit (just 1RU in height and 9-in wide), it can be placed on a desktop or mounted in a rack or on a wall side-by-side with other OS606s. The fan-free design of the OS606 reduces CapEx. This reduces the already low power consumption further, and thereby OpEx while eliminating fan failure and operating noise. The OS606 offers a unique combination of a rich set of features and interfaces that enable easy and flexible field configurations while making it ideal for maintenance and inventory. Unmatched flexibility of Ethernet Virtual Circuits - Selective Q-in-Q and inner/outer VLAN translation - Simplifies, monitors, and troubleshoots services/ applications OAM and PM toolset - End-to-end hardware-based Ethernet service OAM to track SLAs - Standards compliance: IEEE802.3ah, IEEE802.1ag, ITU-T Y.1731, and MEF 17 IA Pay-as-you grow model - Capacity License: upgrading 10/100Base-T ports to 10/100/1000Base-T - Firmware upgrade license - L2+Master-OS® firmware Rear pluggable external power adapter (power supply) MRV Unified Master-OS® firmware for CE service delivery - Simplifies operation and management integration with Operation Support Systems (OSSs) Protection mechanism - Mesh, 1:1 (LOS), and n+1 (LAG) - Ring Protection based on MSTP Supported by MRV’s state-of-the-art Pro-Vision NMS and MegaVision EMS WAN LAN NID/UNI NID/UNI MEF-powered and SLA-based business Ethernet services Metro Ethernet Network NID/UNI NNI End - to - end Service OAM Enabling SOHO access to Cloud Services with accurate performance measurement for OpEx savings (foreseeing future advanced services) Cloud Services OS-606 L I A L I A L I A L I A PWR CONSOLE EIA-232 MGT ETH 1 2 3 4 L 5 A L 6 A - Bandwith on demand - SLA & Performance Monitoring Not sure which solution best meets your needs? Visit www.mrv.com or e-mail us at [email protected] Services Specifications Configuration • 4 x 10/100/1000Base-T RJ45 ports + 2 x 100FX/1000FX SFP ports - Any port can be used for a UNI or NNI service • Industry Standard CLI • Out-of-band management: Ethernet port • Serial interface: RS-232 port • External pluggable power adapter MEF compliance • • • • • MEF CE 2.0 Services Compliant EPL, E-Line, E-Tree & E-LAN – MEF 9 EPL, E-Line, E-Tree & E-LAN Traffic Mgt. – MEF 14 OAM Implementation Agreement (IA) – MEF 17 Abstract Test Suite for UNI Type 2 Part 1 Link OAM - MEF 21 Packet Switching and Simple IP Services • IEEE802.1Q and IEEE802.1ad provider bridges - 4K active VLANs / EVCs - Selective Q-in-Q stacking per ACL criteria - Tag swapping on egress and ingress traffic - Inner classification on double tagged frames • Private VLAN, E-Tree services • Transparent cross-connect mode • Layer 2 control protocols tunneling Traffic Management and QoS • IEEE 802.1p (VPT), DiffServ (DSCP) • Marking/remarking profiles between layers • Eight hardware queues per port with configurable SLs • Per flow SLA metrics • Dual-rate 3-color rate limit per flow Link protection Services • Link Aggregation (LAG n+1) – static and IEEE 802.3ad LACP - Load balancing based on L2, L3, and/or L4 headers Technical Specifications Standards compliance Environment Humidity Diagnostic LEDs Rack Mounting Maintainability Physical dimensions WxDxH • Link level 1:1 Loss of Signal (LOS) protection • Bi-directional Link Fault Reflection Management & Diagnostics Tools • Industry standard CLI and MEF oriented CLI • IPv4 & IPv6 based TELNET, SSHv2, SNMPv3, RMON • RADIUS/TACACS+ AAA for management sessions • Configuration load/save in File Transfer Protocol (FTP), Secure Copy Protocol(SCP) • Internal/Remote Syslog • Scripting tool for macro configurations & maintenance • Action scheduler for automated rules (time/day/cycle) • Supported by MRV’s ProVision NMS OAM • EFM Link OAM (segment-based CO-to-CPE) per IEEE 802.3ah - discovery, port-loopback, remote failure indication, dying gasp • Copper cable diagnostics TDR on RJ45 ports “Extended” L2 Software includes the following additions: Protection • ERPS per ITU-T G.8032v2/Y.1344 • IEEE 802.1d STP, IEEE 802.1w RSTP, IEEE 802.1s MSTP • Protection based on CCM (UNI-to-UNI reflection, 1:1 protection) Advanced OAM • End-to-end service OAM per IEEE 802.1ag - Connectivity Fault Management per service MEP/MIP - In-service EVC loopbacks & Linktrace • Remote failure notification/reflection • Extended frame generator RFC 2544 with L2, L3 traffic generation • End-to-end Performance Measurement ITU-T Y.1731 - Jitter, Latency & Loss per service FCC Part 15 (Class A); EMC Directive: Emission (Class A) and Immunity; LVD Directive: Electrical Safety; CE Marking; TUV-R Mark (Canada, USA); GOST (selected products); RoHS Directive, WEEE Directive. Operating Temp: 0˚to 50˚C (32˚ to 122˚F) Storage Temp: - 40˚ to 70˚C (-40˚ to 158˚F) 85% maximum , non-condensing Global: Power, Management traffic link, Management traffic activity Per port: Service traffic link, Service traffic activity. 19 “ or 23” racks , compact 1 RU height Front end user interfaces Eliminates the need to dismount the system for maintenance or installation of new hardware following initial installation 219.6 x 130 x 42mm (8.64 x 5.12 x 1.65 inch) Weight (kg. /lbs.) 1.2kg (2.64 lb) MTBF HRS @25C /77F 1088341 hr P/N Order Info OS606 LIC-606x1G LIC-606xL2+ OS606/GE/L2+ EM606-PS/AC-EU EM606-PS/AC-US EM606-PS/AC-UK EM606-PS/AC-AU Accesories EM606-BR-1 EM606-BR-F EM606-WBR OS606 FE/GE NID - 4 x RJ45 10/100BaseT (upgrade option to 1000Base-T) and 2 x 100FX SFP (upgrade option to 1000FX) Ports, “Basic” L2 Master-OS™ version, external power supply should be ordered separately. Upgrade license for OS606 - 1GE ports enabler Upgrade license for OS606 – L2+ MasterOS™ suite FE/GE NID - 4 x RJ45 10/100/1000BaseT and 2 x 100FX/1000FX SFP Ports, “Extended” L2+ Master-OS™ version, external power supply should be ordered separately. External AC Power Supply for the OptiSwitch® 606 (90-240VAC) for EU External AC Power Supply for the OptiSwitch® 606 (90-240VAC) for US External AC Power Supply for the OptiSwitch® 606 (90-240VAC) for UK External AC Power Supply for the OptiSwitch® 606 (90-240VAC) for AU 19” mounting brackets for Telco rack. 19” mounting brackets for side-by-side installation of dual OS606 - Two systems 19” rack. Wall mounting brackets for OS606 series * Future release All statements, technical information and recommendations related to the products herein are based upon information believed to be reliable or accurate. However, the accuracy or completeness thereof is not guaranteed, and no responsibility is assumed for any inaccuracies. Please contact MRV Communications for more information. MRV Communications and the MRV Communications logo are trademarks of MRV Communications, Inc. Other trademarks are the property of their respective holders. MRV-OS-606 Rev.03 03-14 Copyright ©2014 MRV Communications, Inc. All Rights Reserved.