Datasheet 10 Gbps 50 GHz DWDM 40 km Single-Mode SFP+ Transceivers SFP-10GDWER-yxx Highlights SFP+ transceiver C-band (standard 50 GHz DWDM ITU grid) Data Rates: 8 Gbps to 11.3 Gbps Protocols supported: - 10G Ethernet (10GBase-ER/EW [LAN/WAN]) - with/without FEC - 10G Fibre Channel with/without FEC - SONET OC-192/STM-64 with/without FEC - 8 Gbps Fibre Channel Single-mode fiber Dual fiber, bi-directional Up to 40 km Duplex LC connector Digital Diagnostics (SFF-8472) Hot-swap Overview Small Form-Factor Pluggable (SFP) interfaces from MRV Communications provide flexible high speed links in a small industry-standard package. They deliver the deployment options and inventory control that network administrators demand for growing networks. SFPs are designed to Multi-Source Agreement (MSA) standards to ensure network equipment compatibility. They are a perfect addition to MRV ‘s extensive lines of networking equipment. Visit the MRV website at www.mrv.com or contact your nearest authorized MRV Communications dealer for more information. Specifications Overview Data Rate 8 - 11.3 Gbps Tx Wavelength C-Band DWDM (channel 17 – 61) Tx Power (Minimum) 0 dBm Tx Dispersion Penalty (@ 10.3125 Gbps) < 3 dB Tx Disable Yes Rx Wavelength Range 1530 - 1565 nm Rx Sensitivity -14.1 dBm Rx Saturation -1 dBm Operating Temperature Range -5 to 70 ºC Power Consumption 1.9 Watt 1 Datasheet Transmitter Specifications (Optical) Parameter Symbol Data Rate B Center Wavelength λC Average Optical Output Power Extinction Ratio Relative Intensity Noise Side Mode Suppression Ratio Optical Return Loss Tolerance Dispersion Penalty (@10.3125Gbps) Optical Output Eye Notes: 1. Min Max Unit 8 11.3 Gbps - nm 1 See Ordering Information Table Notes Pavg 0 4 dBm - ER 4.5 - dB - RIN - -128 dB/Hz - SMSR 30 - dB - - - -21 dB - DP - 3 dB - - Compliant with IEEE 802.3ae - BOL: +/-0.05nm from ITU grid; EOL: +/-0.1nm from ITU grid. Receiver Specifications (Optical) Parameter Data Rate Wavelength of Operation Symbol Min Max Unit Notes B 8 11.3 Gbps - λ 1530 1565 nm - Receiver Sensitivity (@10.3125Gbps) Pmin - -14.1 dBm 1 Maximum Input Power (10-12 BER) Pmax -1 - dBm - - - -26 dB - Reflectance Of Receiver LOS Hysteresis - 0.5 - dB - LOS Thresholds (Increasing Light Input) Plos+ - -16 dBm - LOS Thresholds (Decreasing Light Input) Plos- -30 - dBm - Notes: 1. Specified with BER <1x10-12 and PRBS 231-1 Absolute Maximum Ratings Parameter Symbol Min Max Unit Notes Storage Temperature Range TST -40 85 ºC - Operating Case Temperature TOP -5 70 ºC 1 Operating Relative Humidity RH 0 85 % 2 Supply Voltage Range VCC -0.5 3.6 V - Notes: 1. 2. Measured on top side of SFP+ module at the front center vent hole of the cage. Non condensing 2 Datasheet Transmitter Specifications (Electical) Parameter Symbol Min Max Unit Notes Zd 80 120 Ω - Differential Input Voltage Swing VPP-DIFF 180 700 mV - Input High Voltage (TX Disable) VIH 2.0 VCC V 1 Differential Input Impedence Input LOW Voltage (TX Disable) VIL 0 0.8 V 1 Output High Voltage (TX Fault) VOH 2.0 VCC + 0.3 V 2 Output LOW Voltage (TX Fault) VOL 0 0.8 V 2 Min Max Unit Notes Notes: 1. 2. There is an internal 4.7 to 10 kΩ pull-up resistor to VccT Open collector compatible, 4.7 to 10 kΩ pull-up resistor to Vcc (Host Supply Voltage) Receiver Specifications (Electrical) Parameter Symbol Differential Output Impedance Zd 80 120 Ω - Differential Output Swing VPP-DIFF 300 850 mV - Output Rise and Fall time (20% to 80%) tRH, tFH 28 - ps - Output HIGH Voltage (LOS) VOH VCC - 1.3 VCC - 0.3 V 1 Output Low Voltage (LOS) VOL 0 0.8 V 1 Notes: 1. Open collector compatible, 4.7 to 10 kΩ pull-up resistor to Vcc (Host Supply Voltage) Power Supply Specifications (Electrical) Parameter Symbol Min Max Unit Notes VCC 3.13 3.47 V - DC Common Mode Voltage VCM 0 3.6 V - Supply Current IVCM - 340 mA - Power Consumption PW - 1.9 W - Power Supply Voltage Host Board Connector Pinout Towards Bezel 1 VeeT 2 TX_Fault 3 TX_Disable 4 SDA 5 SCL 6 MOD_ABS 7 RS0 8 RX_LOS 9 RS1 10 VeeR 3 VeeT 20 TD- 19 TD+ 18 VeeT 17 VccT 16 VccR 15 VeeR 14 RD+ 13 RD- 12 VeeR 11 Towards ASIC Datasheet Pin Descriptions Pin Logic Symbol Description 1 - VeeT Module Transmitter Ground 2 LVTTL-O TX_FAULT Module Transmitter Fault 3 LVTTL-I TX_DISABLE Transmitter Disable; Turns off transmitter laser output 4 LVTTL-I/O SDA 2-Wire Serial Interface Data Line 5 LVTTL-I/O SCL 2-Wire Serial Interface Clock 6 - MOD-ABS Module Definition, Grounded in the module 7 LVTTL-I RS0 No function implemented 8 LVTTL-O RX_LOS Receiver Loss of Signal Indication 9 LVTTL-I RS1 No function implemented 10 - VeeR Module Receiver Ground 11 - VeeR Module Receiver Ground 12 CML-O RD- Receiver Inverted Data Output 13 CML-O RD+ Receiver Non-Inverted Data Output 14 - VeeR Module Receiver Ground 15 - VccR Module Receiver 3.3V Supply 16 - VccT Module Transmitter 3.3V Supply 17 - VeeT Module Transmitter Ground 18 CML-I TD+ Transmitter Non-Inverted Data Input 19 CML-I TD- Transmitter Inverted Data Input 20 - VeeT Module Transmitter Ground Outline Drawing 4 Datasheet Ordering Information Model Wavelength (nm) Frequency (THz) Channel Number Distance (km) SFP-10GDWER-H61 1528.38 196.15 H61 40 SFP-10GDWER-C61 1528.77 196.10 C61 40 SFP-10GDWER-H60 1529.16 196.05 H60 40 SFP-10GDWER-C60 1529.55 196.00 C60 40 SFP-10GDWER-H59 1529.94 195.95 H59 40 SFP-10GDWER-C59 1530.33 195.90 C59 40 SFP-10GDWER-H58 1530.73 195.85 H58 40 SFP-10GDWER-C58 1531.12 195.80 C58 40 SFP-10GDWER-H57 1531.51 195.75 H57 40 SFP-10GDWER-C57 1531.90 195.70 C57 40 SFP-10GDWER-H56 1532.29 195.65 H56 40 SFP-10GDWER-C56 1532.68 195.60 C56 40 SFP-10GDWER-H55 1533.07 195.55 H55 40 SFP-10GDWER-C55 1533.47 195.50 C55 40 SFP-10GDWER-H54 1533.86 195.45 H54 40 SFP-10GDWER-C54 1534.25 195.40 C54 40 SFP-10GDWER-H53 1534.64 195.35 H53 40 SFP-10GDWER-C53 1535.04 195.30 C53 40 SFP-10GDWER-H52 1535.43 195.25 H52 40 SFP-10GDWER-C52 1535.82 195.20 C52 40 SFP-10GDWER-H51 1536.22 195.15 H51 40 SFP-10GDWER-C51 1536.61 195.10 C51 40 SFP-10GDWER-H50 1537.00 195.05 H50 40 SFP-10GDWER-C50 1537.40 195.00 C50 40 SFP-10GDWER-H49 1537.79 194.95 H49 40 SFP-10GDWER-C49 1538.19 194.90 C49 40 SFP-10GDWER-H48 1538.58 194.85 H48 40 SFP-10GDWER-C48 1538.98 194.80 C48 40 SFP-10GDWER-H47 1539.37 194.75 H47 40 SFP-10GDWER-C47 1539.77 194.70 C47 40 SFP-10GDWER-H46 1540.16 194.65 H46 40 SFP-10GDWER-C46 1540.56 194.60 C46 40 SFP-10GDWER-H45 1540.95 194.55 H45 40 SFP-10GDWER-C45 1541.35 194.50 C45 40 SFP-10GDWER-H44 1541.75 194.45 H44 40 SFP-10GDWER-C44 1542.14 194.40 C44 40 SFP-10GDWER-H43 1542.54 194.35 H43 40 SFP-10GDWER-C43 1542.94 194.30 C43 40 SFP-10GDWER-H42 1543.33 194.25 H42 40 SFP-10GDWER-C42 1543.73 194.20 C42 40 5 Datasheet Ordering Information Model Wavelength (nm) Frequency (THz) Channel Number Distance (km) SFP-10GDWER-H21 1560.20 192.15 H21 40 SFP-10GDWER-C21 1560.61 192.10 C21 40 SFP-10GDWER-H20 1561.01 192.05 H20 40 SFP-10GDWER-C20 1561.42 192.00 C20 40 SFP-10GDWER-H19 1561.83 191.95 H19 40 SFP-10GDWER-C19 1562.23 191.90 C19 40 SFP-10GDWER-H18 1562.64 191.85 H18 40 SFP-10GDWER-C18 1563.05 191.80 C18 40 SFP-10GDWER-H17 1563.46 191.75 H17 40 SFP-10GDWER-C17 1563.86 191.70 C17 40 Regulatory and Industry Compliances Class 1 Laser Product, complies with EN 60825-1 and 21 CFR 1040.10 except for deviations pursuant to Laser Notice No. 50. dated June 24, 2007 MSA SFF-8074i; Digital Diagnostic SFF-8472 Certified by one or more of the following agencies: TÜV, UL, CSA RoHS Directive; China RoHS; California RoHS Law, REACH Directive SVHC; WEEE Directive The Quality Management System is certified to ISO 9001 by QMI-SAI Global The Environmental Management System is in compliance with ISO 14001 Warnings Handling Precautions: This device is susceptible to damage as a result of electrostatic descharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures. Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation. MRV operates Worldwide sales and service offices across four continents. Contact us at [email protected] MRV Communications Corporate Headquarters 300 Apollo Drive Chelmsford, MA 01824 http://www.mrv.com All statements, technical information and recommendations related to the products herein are based upon information believed to be reliable or accurate. However, the accuracy or completeness thereof is not guaranteed, and no responsibility is assumed for any inaccuracies. Please contact MRV Communications for more information. MRV Communications and the MRV Communications logo are trademarks of MRV Communications, Inc. Other trademarks are the property of their respective holders. MRV-OP-SFP10GDWER-033012 3020186-001 Rev. A1 Copyright ©2012 MRV Communications, Inc. All Rights Reserved.