Atlas, Aurora, & Gemini Magnetic Liquid Level Indicators DESCRIPTION Magnetically coupled liquid level indicators, or MLIs, are in widespread use throughout the process industries. Originally designed as an alternative to sight and gage glass devices, the MLI is now commonly used in both new construction and plant expansion as well as replacement for high maintenance sight and gage glass. Magnetrol’s Atlas, Gemini, and Aurora magnetic level indicators are precision engineered and manufactured to indicate liquid level accurately, reliably and continuously. These units are totally sealed chambers, that require no periodic maintenance; and, they eliminate vapor or liquid emissions problems common with sight and gage glasses. To compliment these products, Magnetrol produces a complete range of level switches and transmitters, including Eclipse® Guided Wave Radar Transmitter. FEATURES • Broad range of chamber styles, or configurations, for each design • Complete range of level switches and level transmitters, including Eclipse Guided Wave Radar APPLICATIONS • Fabricated, non-magnetic chamber assembly, produced in a wide range of metal and plastic materials • Feedwater heaters • Blowdown flash tanks • ANSI and DIN process connections • Industrial boilers • Hot wells • Precision manufactured float with internal magnets and magnetic flux ring (patent pending) • Oil water separators • Vacuum tower bottoms • Flash drums • Alkylation units • Flag or shuttle type indicator, with optional stainless steel scale to reflect height, volume or percentage of level • Surge tanks • Boiler drums • Gas chillers • Propane vessels • Deaerators • Storage tanks TECHNOLOGY Within the piping column of the magnetic level indicator is a float containing an internal group of magnets. A change of level in the process tank corresponds to a similar change within the piping column. In response to the level movement, the float moves up or down accordingly. The individual flags or the follower contain an alignment magnet which couples to the float magnets as the float moves up or down the piping column. Refer to figure 1. This magnet coupling rotates the flags and changes their color–or in the case of the follower–moves the follower to the point of level. Clamped to the piping column in complete isolation from the process liquid is a visual indicator housing. It contains the customer’s choice of indicator (a series of flags or a follower). The position of the follower, or the point at which the flags change color represents true level. Level measurement is indicated or “read” by the corresponding point on the measuring scale. Refer to figure 2. Stainless Steel Chamber Wall Flux ring Liquid Level Indicating Flags Float Magnets Float Figure 1 Figure 2 ATLAS ⁄2" NPT vent 1 The Atlas is Magnetrol’s standard, high performance magnetic level indicator. Atlas is a single chamber design with either 2", 2.5", or 3" chamber diameter, as required by the application. There are twelve basic configuration styles, including top mount models. Atlas magnetic level indicators are produced in a wide range of materials of construction, including plastics. Magnetrol also offers one of the most complete selections of process connection types and sizes in the industry. Top float stop spring Dome cap or flange top Wide range of process connections Flag or shuttle style indicators High level switch (optional) Low level switch Atlas may be equipped with a variety of level (optional) transmitters and switches, as well as, flag and shuttle indicators with or without stainless steel scales. This enables the Atlas to be a complete level and monitoring Broad range of alloy and plastic control. Stainless steel scale for height volume, percent, or custom units of measure ASME B31.1, B31.3, and NACE constructions Dome cap or flange bottom chambers Bottom spring float stop ⁄2" NPT drain 1 2 AURORA Aurora is the next generation of Magnetic Level Indicators. It is state of the art in this technology and reflects Magnetrol’s innovation and commitment to magnetically coupled level indicators. Using a 3" or 4" chamber to house both the Eclipse coaxial style probe and the float, these devices operate seamlessly to provide continuous electronic Guided Wave Radar measurement and visual indication. There are six basic configuration styles, and over fifteen material selections for the Aurora. For the first time ever, the ability to accurately and repeatedly measure ultra low dielectric media, high temperature/high pressure process conditions, and media with shifting and changing dielectric values can be accomplished with Aurora. Eclipse level transmitter Top float stop spring Wide range of process connections 3" or 4" diameter chamber Stainless steel scale for level, volume, percent, or custom units of measure Flag or shuttle style indicators ASME B31.1, B31.3 and NACE constructions Broad range of alloy chambers Dome cap or flange bottom Bottom float stop spring GEMINI Magnetrol’s twin chamber design is unique to the Magnetic level gauge industry. Over 18 unique configuration styles are available with Gemini, and though not available in plastics, it may be produced in the same metal material selections as Atlas. The second chamber facilitates the installation of the Eclipse Guided Wave Radar Transmitter. This provides for a totally redundant measurement system. With a standard magnetic indicator and a side clamp-on transmitter, the float represents a single point of indication. If the float should become damaged due to violent process conditions, the signal from the analog transmitter is lost. With the dual chamber design, Eclipse will continue to measure the liquid level accurately, repeatedly and reliably, as it is not dependent on interaction with the float. Gemini’s magnetic indicator chamber can be equipped with switches, transmitters, blankets or heat tracing, while the secondary chamber houses the electronic measurement instrument. Eclipse or other level transmitter Dome cap or flange top Top float stop spring Wide range of process connections Stainless steel scale for level, volume, percent, or custom units of measure Flag or shuttle style indicators 2", 2.5", or 3" diameter chambers ASME B31.1, B31.3 and NACE constructions Broad range of alloy chambers Dome cap or flange bottom Bottom float stop spring 3 MAGNETIC INDICATOR Design SPECIFICATIONS Atlas and Aurora – single chamber Gemini – dual chamber Materials of construction – MLI Metal alloys 316/316L or 304/304L stainless steel, 316 Ti stainless steel, 321 stainless steel, Titanium, Monel K500, Hastelloy B, Hastelloy C-276, Inconel 625, Inconel 825, Alloy 20, Electropolished 316 stainless steel, 904L stainless steel Plastics Fiberglass, PVC, CPVC, kynar, polypropylene Materials of construction – Float Same as chamber materials, 316 stainless steel standard Construction types Conforms to ASME B31.1 and B31.3 Conforms to NACE MRO 175 Certified material test reports (CMTR) Available upon request Pressure class ratings ANSI 150#, 300#, 600#, 900#, 1500#, 2500# Process connection sizes 1 DIN PN16, PN25/40, PN64, PN100, PN160, PN250, PN320 ⁄2" to 8" DN 15 to DN150 Process connection types MNPT, FNPT, weldoletTM, sockoletTM, threaded couplings, threaded nipples, buttweld nipples, plain-end nipples, slip-on flanges, weldneck flanges, lap joint flanges, tri-clamp fitting, Van Stone flanges Measuring range 12 to 600 inch (30 to 1524 centimeters) standard Consult factory for lengths over 600 inch (50 feet) Temperature range -320° to +1000° F (-196° to +538° C) Pressure range Full vacuum to 4500 psig (310 bar) Specific gravity range As low as 0.25 Indicators Magnetically actuated flag assembly Shuttle follower Flag assembly seal Inert gas filled and hermetically sealed Visual indication Easily visible from 75 to 100 feet Scale options Etched stainless steel with either height, volume, or percentage units Switch options Model OES-100, cam operated snap action Model OPS-200, pneumatic Model ORS-300, electric reed type Transmitter options Model 705 Eclipse Guided Wave Radar Model OCT-400, analog reed chain High temperature options Electric or steam tracing with or without special high temperature insulation Low temperature options 4 Cryogenic insulation with special polymeric frost extension CHAMBER STYLES ATLAS 4'' 4" 7" 7" 4" 9 Visual Indicator Length 6 3 Center to Center in. Center to Center 0 10'' 10" 10" Side Connection Side Connection Weldneck Flanges Top Mount AURORA 10 5/8'' 4" 10 5/8" 7'' 4" Center to Center 7'' Center to Center 10'' 10'' Side Connection Side Mount Chamber GEMINI 7" 4" 7" 3 1/2" 7" 4" 4" 3 1/2" 3 1/2" 9 9 9 6 Center to Center 6 6 3 in. Center to Center Center to Center 3 in. 3 in. 0 0 0 3 1/2" 3 1/2" 3 1/2" 10" 10" 10" Side Connection Twin Chamber Side Connection Twin Chamber Weldneck Flanges Top In/Bottom Out Chamber with Spool Pieces The above drawings represent a small selection of the broad range of MLIs available. Consult the factory complete outline drawings. 5 FLOAT The float is the key to the magnetic level gauge operation. It is responsible for operating the indicator, switches and transmitters via interaction of the internal magnets and the magnets of various external indicators and clamp on accessories. Precisely aligned vertical magnets Flux ring Manufactured from a wide range of alloys, including Titanium, the float is precision welded by either a pulse TIG process or Electron Beam process. Within the float are high strength magnets, precisely aligned and held in place with a magnetic flux ring (patent pending) that assures a constant 360° magnetic field and gauss rating. The magnets are designed for long term service even in elevated temperatures and pressures. INDICATING Precision pulse TIG or electron beam welded float Laser engraved specific gravity data and serial number SCALE Another option from Magnetrol is a stainless steel scale for display of a wide range of engineering units of measure. This scale is mounted adjacent to the flag bar graph assembly or shuttle, and may be produced to show height, percentage of level, volume, or volume. The scales are available in either English or Metric units. Stainless steel scale with level units Flag type indicating scale TEMPERATURE Shuttle type indicating scale OPTIONS HIGH Magnetic level indicators can be ordered with several different tracing options to heat the external chamber. Tracing systems require that a special blanket (custom designed to meet the customers specifications) cover the entire chamber and tracing equipment. Refer to page 11 for temperature guidelines. Frost extension LOW To facilitate operation where the product is kept cold via chillers, refrigerants and condensers, a frost extension option and low temperature insulation are offered. The frost extension is constructed of durable acrylic plastic and suitable for contact with media as cold as -320° F (-196° C) such as liquid nitrogen. 6 Low temperature blanket SWITCHES & TRANSMITTERS ELECTRO-MAGNETIC SWITCHES SPECIFICATIONS Switch Type: Model OES-100 Model OES-100 Magnetically actuated, bi-stable cam drive snap action switch Two SPDT 10.1 amp 125-250 VAC, 1.5 amp 250 VDC Model ORS-300 Bi-stable reed switch One SPDT contact rated 1.0 amp Maximum Dead Band: ±0.75" float travel ±0.50" float travel Temperature Range: -58° to +392° F (-50° to +200° C) -58° to +482° F (-50° to +250° C) Enclosure: NEMA 4X/7/9 NEMA 4X/7/9 Also available Model OPS-200 pneumatic switch Model ORS-300 TRANSMITTERS SPECIFICATIONS Model: OCT-400 JupiterTM Type: Reed Chain Magnetostrictive Guided Wave Radar Supply Voltage: 24 VDC 24 VDC 24 VDC Resolution: ± 0.50" ± 0.015" ± 0.1" Output Signal: 4-20 mA 4-20 mA (HART optional) 4-20 mA (HART optional) Temperature Range: -40° to +158° F (-40° to +70° C) -40° to +175° F (-40° to +79° C) -40° to +160° F (-40° to +71° C) Enclosure: NEMA 4X/7/9 NEMA 4X/7/9 NEMA 4X/7/9 Model OCT-400 AGENCY MODEL APPROVAL CATEGORY Factory Mutual 2xx-100x-xxx Class I, Div. 1, Grps B, C, & D Class I, Div. 2, Grps A, B, C, & D Class II, Div. 1 & 2, Grps E, F, & G Class III Type 4X Canadian Standards Association OES-100E-001 Class I, Div. 1 & 2, Grps B, C, & D Class II, Grps E, F, & G Class III ORS-300E-001 Class I, Div. 1, Grps B, C, & D Class I, Div. 2, Grps A, B, C, & D Class II, Grps E, F, & G Class III OCT-400x-xxx Class I, Div. 1, Grps B, C, & D Class I, Div. 2, Grps A, B, C, & D Class II, Grps E, F, & G Class III 2xx-100x-xxx Class I, Div. 1, Grps B, C, & D Class I, Div. 2, Grps A, B, C, & D Class II, Div. 1 & 2, Grps E, F, & G Class III Type 4X Eclipse Right: Atlas with high and low level switches Left: Atlas with Reed chain transmitter Approval files for Electro-Magnetic Switches and Reed Chain Transmitters open at FM. Consult factory for further information. 7 MAGNETIC INDICATOR Model Number IMPORTANT: Operating specific gravity, maximum pressure, and maximum temperature must be provided upon placement of order. Providing information on the liquid, operating pressure, operating temperature, minimum specific gravity, and the quotation number will expedite the processing of your order. • = Atlas only A B C D E F M N P Q R S T 150# ANSI class 300# ANSI class 600# ANSI class 900# ANSI class 1500# ANSI class 2500# ANSI class PN 16 DIN class PN 25/40 DIN class PN 64 DIN class PN 100 DIN class PN 160 DIN class PN 250 DIN class PN 320 DIN class 1 2 3 4 ■5 ■6 •7 •8 A B C D ✱J ✱K ✱L ✱M ✱N ✱P ✱Q ✱R CHAMBER PRESSURE RATING • • Inches cm 1 A 2 B 3 C ■ = Atlas or Gemini only ✱ = Gemini only Atlas, Aurora chamber or Gemini indicator chamber Gemini Eclipse chamber Process Connections Top Bottom Top Bottom Side/side dome cap RF slip-on w/blind flange dome cap dome cap Side/side RF slip-on w/blind flange dome cap dome cap dome cap Side/side RF slip-on w/blind flange RF slip-on w/blind flange dome cap dome cap Side/side for interface dome cap RF slip-on w/blind flange dome cap dome cap Top/bottom RF slip-on flange RF slip-on flange dome cap dome cap Top/bottom spool pieces RF slip-on flange RF slip-on flange dome cap dome cap Top mounted n/a RF slip-on flange n/a n/a Top mounted w/stilling well n/a RF slip-on flange n/a n/a Side/side dome cap RF weldneck w/blind flange dome cap dome cap Side/side RF weldneck w/blind flange dome cap dome cap dome cap Side/side RF weldneck w/blind flange RF weldneck w/blind flange dome cap dome cap Side/side for interface dome cap RF weldneck w/blind flange dome cap dome cap Side/side dome cap RF slip-on w/blind flange RF slip-on flange dome cap Side/side RF slip-on w/blind flange dome cap RF slip-on flange dome cap Side/side RF slip-on w/blind flange RF slip-on w/blind flange RF slip-on flange dome cap Top/bottom RF slip-on flange RF slip-on flange RF slip-on flange dome cap Top/bottom spool pieces RF slip-on flange RF slip-on flange RF slip-on flange dome cap Side/side dome cap RF weldneck w/blind flange RF weldneck flange dome cap Side/side RF weldneck w/blind flange dome cap RF weldneck flange dome cap Side/side RF weldneck w/blind flange RF weldneck w/blind flange RF weldneck flange dome cap LEVEL INDICATOR CHAMBER MOUNTING CONFIGURATION • • (CONSULT FACTORY FOR SPECIAL CONFIGURATIONS) For requirements not specified in the model number selection, add the prefix "X" to the model and describe the special modifications required. Example: X1AC-3CB3-AAA/060 X = 3⁄4" NPT vent 180° from upper process connection Refer to page 17 for continuation of model number selection. CHAMBER TYPE Atlas Aurora (Eclipse internal mount, single 3" or 4" chamber) Gemini (Eclipse internal mount, dual chambers, 2" or 3") CHAMBER MATERIAL OF CONSTRUCTION A B C D F G H J K L M N P Q R •1 •2 •3 •4 •5 316/316L SS 316/316L SS w/CS flanges 304/304L SS 304/304L SS w/CS flanges 321 SS Titanium Monel Hastelloy B Hastelloy C-276 Inconel 625 Incoloy 825 Alloy 20 Electropolished 316 SS 904L SS 347 SS Fiberglass PVC CPVC Kynar Polypropylene • = Atlas Only 8 Standard vent & drain connections are 1⁄2" plugged NPT. Consult factory for options. 1 2 3 4 5 6 7 H J K L M N P Q R S T V W Y A B C D E F G Black/orange flags Black/orange flags Black/orange flags Black/orange flags Black/orange flags Black/orange flags Black/orange flags Black/yellow flags Black/yellow flags Black/yellow flags Black/yellow flags Black/yellow flags Black/yellow flags Black/yellow flags Red/white flags Red/white flags Red/white flags Red/white flags Red/white flags Red/white flags Red/white flags Orange shuttle Orange shuttle Orange shuttle Orange shuttle Orange shuttle Orange shuttle Orange shuttle No scale Height in cm Height in feet/inches Height in % of span Volume in gallons Volume in liters Height in running inches No scale Height in cm Height in inches Height in % of span Volume in gallons Volume in liters Height in running inches No scale Height in cm Height in inches Height in % of span Volume in gallons Volume in liters Height in running inches No scale Height in cm Height in inches Height in % of span Volume in gallons Volume in liters Height in running inches INDICATOR TYPE SCALE UNITS A B C D E F G H J K L M N P Q R S ⁄2" ⁄4" 1" 11⁄2" 2" 21⁄2" 3" 4" 6" 8" DN 20 DN 25 DN 40 DN 50 DN 80 DN 100 DN 150 1 3 Q Threaded nipple Threaded coupling Plain-end nipple Socketweld coupling Buttweld nipple WeldoletTM SockoletTM ThreadoletTM Slip-on FF flange Slip-on RF flange Slip-on RTJ flange Weld neck RF flange Weld neck RTJ flange Lap joint flange Tri-clamp fitting Van Stone flange (plastic only) HT insulation blanket to 500° F HT insulation blanket to 1000° F HT insulation blanket to 500° F HT insulation blanket to 1000° F Cryogenic insulation to -100° F Cryogenic insulation to -200° F Cryogenic insulation to -320° F Steam tracing Steam tracing with blanket Electric heat tracing 40° F & below with insulation blanket Electric heat tracing 40° to 200° F with insulation blanket Electric heat tracing 200° to 500° F with insulation blanket Electric heat tracing 500° to 800° F with insulation blanket None ■ C ■ D • N • P • Q R S T U V W 0 • PROCESS CONNECTION TYPE A B C D E F G T H J K L M N P • A • B TEMPERATURE OPTIONS • • SIZE OF PROCESS CONNECTION ■ = On chamber only • = On chamber and flanges 0 MIN S.G. 100 0.65 to 1.80 0.50 B to 0.64 0.65 1 to 1.80 0.50 2 to 0.64 A • • MAXIMUM PRESSURE (PSI) @ °F 200 300 400 500 600 USED W/MLI Atlas & Gemini Atlas 725 & Gemini 950 950 925 925 900 850 800 800 775 775 775 675 675 650 650 625 600 Aurora 525 525 500 500 500 475 Aurora Orion capabilities exceed those listed in the above table. Pressures up to 4500 psi and specific gravities as low as 0.35 can be achieved. Consult factory for assistance. • CHAMBER LENGTH Specify length in Inches when first digit is numeric Lengths from 12 to 600 inches Inch Code Example: 24 inches = Code 024 Specify length in Centimeters when first digit is alpha Lengths from 30 to 1524 cm Centimeter Code Example: 60 cm = Code 060 Consult factory for longer or shorter lengths. 9 ECLIPSE 0 1 Guided Wave Radar 1 2 3 4 A B C D E F 4–20 mA 4–20 mA with HART® OUTPUT 1 2 3 4 0 5 Integral, GP, IS & NI, FM/CSA Remote, GP, IS & NI, FM/CSA Integral, EP, IS & NI, FM/CSA Remote, EP, IS & NI, FM/CSA Integral, GP & IS, CENELEC/ATEX Exia Remote, GP & IS, CENELEC/ATEX Exia Integral, EP, CENELEC/ATEX Exd Remote, EP, CENELEC/ATEX Exd Integral, NI, CENELEC/ATEX Exn Remote, NI, CENELEC/ATEX Exn 0 1 2 3 TRANSMITTER MOUNTING / APPROVALS English Spanish French German 0 1 5 ⁄4" NPT M20 PG 13.5 PG 16 3 CONDUIT ENTRY None Digital display and keypad 0 1 DISPLAY / KEYPAD MENU LANGUAGE 7 Transmitters Cast aluminum 316 SS HOUSING MATERIAL • • • • • • with Eclipse Guided Wave Radar Probe • • • • • UNIT OF MEASURE PROBE MOUNTING CONNECTION E English unit of measure M Metric unit of measure PROBE TYPE A B D P R S A B C T U Y Z • 7 Coaxial Twin rod HTHP coaxial HP coaxial Overfill coaxial Steam coaxial PROBE & FLANGE MATERIAL USED WITH PROBE TYPE USED WITH MLI 316/316L SS flange & probe Hastelloy C flange & probe Monel flange & probe Hastelloy C flange & probe Monel flange & probe 316/316L SS flange & probe Carbon steel flange & 316/316L SS probe All A, B, P, R A, B, P, R A, R A, R A, D, P, R, S Gemini Gemini Gemini Aurora Aurora Aurora A, D, P, R, S Aurora O-RING MATERIAL ⁄4" NPT thread ➀ 0 Viton 2" NPT thread ➁ 1 EPDM 2" 150 lb. RF ANSI flange 2 Kalrez 2" 300 lb. RF ANSI flange 8 Aegis PF128 2" 600 lb. RF ANSI flange ➂ N None 2" 900/1500 lb. RF ANSI flange ➂ 2" 2500 lb. RF ANSI flange ➂ PROBE LENGTH 3" 150 lb. RF ANSI flange Specify length in: Inches with second digit 'E', 3" 300 lb. RF ANSI flange Lengths from 24 to 240 inches 3" 600 lb. RF ANSI flange ➂ Probe length specified should be 3" 900 lb. RF ANSI flange ➂ measuring range of MLI plus 13 inches 3" 1500 lb. RF ANSI flange ➂ Inch Code 3" 2500 lb. RF ANSI flange ➂ Example: 24 inches = Code 024 4" 150 lb. RF ANSI flange Specify length in: 4" 300 lb. RF ANSI flange Centimeters with second digit 'M' 4" 600 lb. RF ANSI flange ➂ Lengths from 60 to 610 cm 4" 900 lb. RF ANSI flange ➂ Probe length specified should be 4" 1500 lb. RF ANSI flange ➂ measuring range of MLI plus 33 cm 4" 2500 lb. RF ANSI flange ➂ Centimeter Code ➀ Probe types A, D, P, R, and S only. Example: 60 cm = Code 060 11 42 43 44 45 46 48 53 54 55 56 57 58 63 64 65 66 67 68 3 ➁ Probe type B only. ➂ Probe types D, P, and S only. 10 • • • JUPITER Transmitters 4–20 mA with LCD 4–20 mA with HART® & LCD OUTPUT Specify measuring range in: Inches when third digit is numeric, Lengths from 6 to 410 inches *Must be used for temperatures above 250° F or if the top of the MLI is flanged. 1 2 3 A B C 1 Top mount, length in inches Top mount offset, length in inches* Bottom mount offset, length in inches Top mount, length in centimeters Top mount offset, length in centimeters* Bottom mount offset, length in centimeters CONFIGURATION / UNITS OF MEASURE 2 REED 3 4 HOUSING MATL / MOUNTING / CONDUIT ENTRY • • CHAIN 2 Cast aluminum with 3⁄4" NPT conduit entry, FM/CSA, EP, NI Cast aluminum with M20 conduit entry, FM/CSA, EP, NI 316 SS with 3⁄4" NPT conduit entry, FM/CSA, EP, NI 316 SS with M20 conduit entry, FM/CSA, EP, NI 1 0 0 • Inch Code Example: 24 inches = Code 024 Specify measuring range in: Centimeters when third digit is alpha Lengths from 15 to 999 cm Centimeter Code Example: 60 cm = Code 060 PROBE LENGTH • • • 2 4 Magnetostrictive Transmitters Specify active length in: Inches when seventh digit 'E', Active lengths from 6 to 198" E English unit of measure M Metric unit of measure UNIT OF MEASURE Top mount Bottom mount Centimeter Code Example: 50 cm = Code 050 MOUNTING 0 1 Stainless steel Aluminum Note: Finished probe length equals active length plus 8" PROBE LENGTH ENCLOSURE O C ELECTRIC OES-1 ORS-3 T 4 Specify active length in: Centimeters when seventh digit 'M', Active lengths from 15 to 503 cm • • • • • • 0 1 Inch Code Example: 24 inches = Code 024 Switches Electric DPDT snap switch in cast aluminum, clamp mounted housing, NEMA 4X/7/9 Electric bi-stable SPDT reed switch in stainless steel, clamp mounted housing, NEMA 4X/7/9 SWITCH & ENCLOSURE • • • • 0 0 E O O 1 11 QUALITY The quality assurance system in place at Magnetrol guarantees the highest level of quality throughout the company. Magnetrol is committed to providing full customer satisfaction both in quality products and quality service. Magnetrol’s corporate quality assurance system is registered to ISO 9001 affirming its commitment to known international quality standards providing the strongest assurance of product/service quality available. WARRANTY All Magnetrol magnetic level indicators are warranted free of defects in materials or workmanship for five full years from the date of original factory shipment. cause of the claim is determined to be covered under the warranty; then, Magnetrol will repair or replace the control at no cost to the purchaser (or owner) other than transportation. All Magnetrol electronic components are warranted free of defects in materials or workmanship for one full year from the date of original factory shipment. Magnetrol shall not be liable for misapplication, labor claims, direct or consequential damage or expense arising from the installation or use of equipment. There are no other warranties expressed or implied, except special written warranties covering some Magnetrol products. If returned within the warranty period; and, upon factory inspection of the control, the For additional information on Magnetic Level Indicators, see Instruction Manual 46-638. For additional information on Eclipse Guided Wave Radar transmitters, see Instruction Manual 57-600. 5300 Belmont Road • Downers Grove, Illinois 60515-4499 • 630-969-4000 • Fax 630-969-9489 • www.magnetrol.com 145 Jardin Drive, Units 1 & 2 • Concord, Ontario Canada L4K 1X7 • 905-738-9600 • Fax 905-738-1306 Heikenstraat 6 • B 9240 Zele, Belgium • 052 45.11.11 • Telex 25944 • Fax 052 45.09.93 Regent Business Ctr., Jubilee Rd. • Burgess Hill, Sussex RH15 9TL U.K. • 01444-871313 • Fax 01444-871317 Copyright © 2003 Magnetrol International, Incorporated. All rights reserved. Printed in the USA. Magnetrol and Magnetrol logotype are registered trademarks of Magnetrol International. Performance specifications are effective with date of issue and are subject to change without notice. The brand and product names contained within this document are trademarks or registered trademarks of their respective holders. BULLETIN: 46-138.2 EFFECTIVE: December 2002 SUPERSEDES: October 2001