SIDE MOUNTING - Magnetrol International

SIDE MOUNTING
®
Liquid Float Level Switches
DESCRIPTION
Up to 409 mm (16.12") switch differential
Magnetrol side mounting controls mount horizontally to any
tank or vessel through a threaded or flanged pipe connection. Standard models are normally equipped with a single
switch mechanism for high or low level alarm or control
applications. Tandem models with two switch mechanisms
are available for two level stage applications, providing the
operating functions of two separate instruments such as
high and low level alarm.
F E AT U R E S
T62 with threaded
process connection
• Carbon or stainless steel body materials (other materials
available at request)
• Flanged and threaded process connections
• Process temperature up to 400 °C (750 °F)
• Up to 2 switch levels (T67)
• Specific gravity as low as 0,40
• Process pressure up to 82,7 bar (1200 psi)
• Field adjustable level differentials from 32 mm (1.25") up
to 409 mm (16.12")
• Standard anti corrosive protection
Optional:
- NACE construction (MR-01-75)
- Interface calibration
- Special actuating levels
- Code compliance construction
- Special tank connections
- Extreme temperature modifications
- Class 1, Group B explosion proof electrical enclosure
- Special exterior surface preparation and finish
T62 with flanged
process connection
A G E N C Y A P P R O VA L S
Agency
Approval
ATEX
II 2G EEx d II C T6, explosion proof
II 1G EEx ia II C T6, intrinsically safe
CENELEC
CCE ➀
EEx d II C T6, explosion proof
FM
Class I, Div. 1, Groups C & D
Class II, Div. 1, Groups E, F & G, Type NEMA 7/9
Non-Hazardous area
FM/CSA ➁
A P P L I C AT I O N S
• Foaming or surging liquids
• Sewage handling
• Paints
R1 (1) 136/MI/433, explosion proof
Explosion proof area –
Groups B, C, D, E, F & G Type NEMA 4X/7/9
• Varnishes
• Heavy oils
• Liquids with solids
SAA ➁
LRS
Explosion proof area
Lloyds Register of Shipment (marine applications)
GOST/
GOSGORTECHNADZOR ➁
Russian Authorisation Standards
Other approvals are available, consult factory for more details
➀ For CCE approved units, use the ATEX explosion proof model
numbers.
➁ Consult factory for proper model numbers.
Worldwide level and flow solutions
P R I N C I P L E O F O P E R AT I O N
A permanent magnet A is attached to a pivoted switch B .
As the float C falls following the liquid level, it raises the
magnet attractor D into the field of the magnet, which in
turn snaps against the non-magnetic barrier tube E , tilting the
switch. The barrier tube provides a static seal between the
switch mechanism and the float, eliminating the need for a
flexing bellows seal, packing gland or other failure prone
sealing elements.
When the liquid level rises, the float draws the magnet
attractor below the magnetic field. The magnet swings out
and tilts the switch to the reverse position causing high
level switch actuation A .
B
4
pivot
5
4
6
5
6
return spring
E
A
A
D
pivot
C
rising level
falling level
MOUNTING
High/low level alarm
Pump control
T62/T64
in external cage
T67
T62/T64
2
AVA I L A B L E S W I T C H M E C H A N I S M S
Type of switch module ➀
Max. Process Temp. ➁
Switch ratings – A res. ➂
Code
24 V DC 240 V AC 120 V AC
➀
➁
➂
➃
Micro switch
max 120 °C (250 °F)
6
15
15
B
Micro switch
max 230 °C (450 °F)
10
Micro switch - DC current
max 120 °C (250 °F)
10
15
15
C
–
10
Micro switch with gold alloy contacts
max 120 °C (250 °F)
D
1
–
1
U
Hermetically sealed micro switch
max 290 °C (550 °F)
5
5
5
HS ➃
Hermetically sealed micro switch with silver plated contacts
max 230 °C (450 °F)
3
1
1
W
Hermetically sealed micro switch with gold plated contacts
max 230 °C (450 °F)
0,5
0,5
0,5
X
Hermetically sealed micro switch
max 400 °C (750 °F)
4
–
2,5
F
Proximity switch - type SJ 3.5 SN
max 100 °C (210 °F)
NA
NA
NA
V
Mercury switch
max 290 °C (550 °F)
10
6,5
13
A
Mercury switch
max 400 °C (750 °F)
10
6,5
13
3
Pneumatic bleed type (open air)
max 200 °C (400 °F)
NA
NA
NA
J
Pneumatic non bleed type (closed circuit)
max 200 °C (400 °F)
NA
NA
NA
K
For applications with heavy vibration, consult factory for suited switch modules.
Max process temperature is specified at 40 °C (100 °F) ambient temperature and for non condensing applications.
For more details - see bulletin BE 42-120.
For condensing applications, max process temperature is down-rated to 200 °C (400 °F) @ 40 °C (100 °F) ambient.
Type B, C, D & U
Type HS
Type F, W & X
Type V
Type A & 3
Type J & K
AVA I L A B L E H O U S I N G S
•
•
•
•
•
For Non Ex use
IP 66
Die cast Aluminium
2 Entries (one plugged)
Standard blue
anti corrosive coating
• Housing heater/drain
available, consult factory
•
•
•
•
•
For Exd/Exi use
IP 66
Die cast Aluminium
2 Entries (one plugged)
Standard blue
anti corrosive coating
• ATEX II 2G EEx d II C T6
• ATEX II 1G EEx ia II C T6
•
•
•
•
For Exd use
IP 66
Cast Iron
One entry (2 entries at
request)
• Standard blue
anti corrosive coating
• CENELEC EEx d II C T6
•
•
•
•
For pneumatic switches
IP 53 (NEMA 3R)
IP 55 optional at request
Alu base / cold rolled steel
cover
• Standard blue
anti corrosive coating
•
•
•
•
•
For Exd use
IP 66 (NEMA 7/9)
Die cast Aluminium
2 Entries (one plugged)
Standard blue
anti corrosive coating
• FM, Class I, Div. 1,
Groups C & D
• FM, Class II, Div. 1,
Groups E, F & G
3
S E L E C T I O N D ATA
Adjustable
differential
Min S.G. ≥ 0,5
Max pressure: 34,5 bar (500 psi)
T62
Fixed
differential
Min S.G. ≥ 0,4
Max pressure: 22,7 bar (1200 psi)
T64
Adjustable
differential
Min S.G. ≥ 0,5
Max pressure: 34,5 bar (500 psi)
T67
Single switch models
Dual switch models
Level differential in mm (inches)
Models
T62
threaded
dim. "D"
77,9 mm (3.07")
3" – Sch 40
Float stem length versus level differential
Differential
dim. "L"
min
max
102,3 mm (4.03")
4" – Sch 40
T67
threaded
77,9 mm (3.07")
3" – Sch 40
T67
flanged
73,7 mm (2.90")
3" – Sch 80
457 mm (18")
660 mm (26")
Not applicable
32 (1.26)
51 (2.01)
73 (2.87)
102 (4.02)
50 mm (2")
148 (5.83)
206 (8.11)
294 (11.58)
409 (16.10)
100 mm (4")
111 (4.37)
155 (6.10)
221 (8.70)
310 (12.20)
150 mm (6")
38 (1.50)
119 (4.69)
170 (6.69)
236 (9.29)
200 mm (8")
-
97 (3.82)
138 (5.43)
192 (7.56)
250 mm (10")
-
81 (3.19)
116 (4.57)
162 (6.38)
305 mm (12")
-
-
100 (3.94)
138 (5.43)
32 (1.26)
41 (1.61)
67 (2.64)
95 (3.74)
50 mm (2")
89 (3.50)
130 (5.12)
191 (7.52)
273 (10.75)
100 mm (4")
83 (3.27)
121 (4.76)
178 (7.01)
254 (10.00)
150 mm (6")
-
95 (3.74)
137 (5.39)
197 (7.76)
200 mm (8")
-
76 (2.99)
114 (4.49)
159 (6.26)
250 mm (10")
-
64 (2.52)
95 (3.74)
137 (5.39)
305 mm (12")
-
-
83 (3.27)
117 (4.61)
fixed
max 178 mm (7")
32 (1.26)
Not applicable
Not applicable
Not applicable
min
max 57 mm
(2.25")
25 (1.00)
38 (1.50)
54 (2.12)
76 (3.00)
64 (2.50)
95 (3.75)
140 (5.50)
197 (7.75)
max 89 mm
(3.50")
25 (1.00)
38 (1.50)
54 (2.12)
76 (3.00)
48 (1.88)
68 (2.69)
99 (3.88)
140 (5.50)
73,7 mm (2.90")
3" – Sch 80
T64 flanged
305 mm (12")
Not applicable
min
T62
flanged
203 mm (8")
max
max
min
max
All units are factory set at minimum differential unless otherwise specified.
Consult factory for differentials not shown.
ø D min. nozzle opening
ø D min. nozzle opening
switch actuates
rising level
CL
of control
level diff.
switch 1 level
level diff. differential
switch 2
switch actuates
falling level
T67
L
switch actuates
rising level
CL
of control
switch actuates
falling level
T67
T62
float
level diff.
switch 1 level
level diff. differential
switch 2
L
T62/T64
float
EXPEDITE SHIP PLAN (ESP)
Several mechanical switches are available for quick shipment, within max. 3 weeks after factory receipt of purchase order,
through the Expedite Ship Plan (ESP).
Models covered by ESP service are conveniently grey coded in the selection data charts.
To take advantage of ESP, simply match the grey coded model number codes (standard dimensions apply).
ESP service may not apply to orders of ten units or more. Contact your local representative for lead times on larger volume
orders, as well as other products and options.
4
S E L E C T I O N D ATA
A complete measuring system consists of:
1. Order code for side mounted models (each unit can be factory calibrated when specific level differentials are specified
separately).
2. Order code for modified models or adders: put an "X" in front of the closest matching order code and specify the modifications/adders separately
eg. XT62-AG3A-AAP
X = with material certification EN 10204 / DIN 50049-3.1.B
3. OPTION: External cage: consult factory for model description.
1. Order code for T62/T67 side mounted float level switch
BASIC MODEL NUMBER1
– Single switch model
T 6 2
down to S.G. 0,50
up to 34,5 bar (500 psi)
– Dual switch model
T 6 7
down to S.G. 0,50
up to 34,5 bar (500 psi)
MATERIALS OF CONSTRUCTION
Code
Cage & process
connection material
A
Float and trim
400 series SST
Carbon steel
B
Magnetic sleeve
316 SST (1.4401)
316 SST (1.4401)
316/316L (1.4401/1.4404)
D
PROCESS CONNECTION
– threaded
F 2
3" NPT
– ANSI flanges
G 3
3" 150 lbs
G 4
3" 300 lbs
H 3
4" 150 lbs
H 4
4" 300 lbs
ANSI
ANSI
ANSI
ANSI
.– DIN flanges
7 F
DN 80, PN 16 DIN 2527 form C
7 G
DN 80, PN 25/40 DIN 2527 form C
8 F
DN 100, PN 16 DIN 2527 form C
8 G
DN 100, PN 25/40 DIN 2527 form C
RF
RF
RF
RF
FLOAT AND STEM LENGTH
Stem length versus min S.G.
Float size
203 mm
305 mm
457 mm
660 mm
mm (inches) ➀
(8")
(12")
(18")
(26")
A
0,80
B
0,80 C 0,90 D 0,90
ø 64 (2.50)
E
0,52
F
0,55 G 0,60 H 0,66 ø 64 x 102 (2.50 x 4.00)
J
0,55
K
0,55
L
0,60 M 0,60
ø 76 (3.00)
N 0,50
P
0,50 Q 0,55 R 0,55
ø 89 (3.50)
S
0,65
T
0,65
V
0,70 W 0,70 ø 76 x 127 (3.00 x 5.00)
Max pressure bar (psi)
@ 40 °C
@ 400 °C
(100 °F)
(750 °F)
24,1 (350) 13,8 (200)
6,9 (100)
4,1 (60)
17,2 (250) 10,3 (150)
27,6 (400) 15,5 (225)
34,5 (500) 20,7 (300)
➀ All floats can be screwed to float stem from inside of vessel in case the float cannot pass through the nozzle.
SWITCH MECHANISM & ENCLOSURE
- for T62 units (see page 6)
- for T67 units (see page 7)
- for pneumatic switch mechanisms (see table below)
complete order code for T62/T67 side mounted float level switch
T 6
Select pneumatic switch mechanism & enclosure - for T62/T64 models
Pneumatic switch type
Series J
(open air)
Series K
(closed circuit)
NEMA 3R (IP 53)
Max supply pressure
bar (psi)
Max liquid temperature
°C (°F)
Bleed orifice Ø
mm (inches)
material code A
material codes B & D
6,9 (100)
200 (400)
1,60 (0.063)
JDE
JDE
4,1 (60)
200 (400)
2,39 (0.094)
JEE
JEE
4,1 (60)
370 (700)
1,40 (0.055)
JFE
JFE
6,9 (100)
200 (400)
–
–
KOE
2,8 (40)
200 (400)
–
KOG
–
5
1. Order code for T64 side mounted float level switch
BASIC MODEL NUMBER1
– Single switch model
T 6 4
down to S.G. 0,40
up to 82,7 bar (1200 psi)
MATERIALS OF CONSTRUCTION
Code
Cage & process
connection material
Carbon steel
A
Float / trim
Magnetic sleeve
304 SST (1.4301) / 316 SST (1.4401)
400 series SST
PROCESS CONNECTION
– ANSI flanges
H 3
4" 150 lbs ANSI RF
H 4
4" 300 lbs ANSI RF
H 5
4" 600 lbs ANSI RF
.– DIN flanges
8 F
DN 100,
8 G
DN 100,
8 H
DN 100,
8 J
DN 100,
PN
PN
PN
PN
16 DIN 2527 form C
25/40 DIN 2527 form C
64 DIN 2527 form E
100 DIN 2527 form E
FLOAT AND STEM LENGTH
N
Fixed stem length: 203 mm (8")
Min. S.G: 0,40
Float size: ø 89 mm (3.50")
Float rating: 82,7 bar (1200 psi) @ 40 °C (100 °F)
400 °C (750 °F) @ 51,7 bar (750 psi)
SWITCH MECHANISM & ENCLOSURE
T 6 4
A
- for electric switch mechanisms (see table below)
- for pneumatic switch mechanisms (see page 5)
complete order code for T64 side mounted float level switch
N
Select electric switch mechanism & enclosure for T62 and T64 models (see page 3 for switch ratings)
All models with material code A
qty and
switch
type
A
3
B
C
D
F
HS
U
V
W
X
6
Weather proof
(IP 66)
cast Aluminium
All models with material codes B and D
ATEX (IP 66)
CENELEC (IP 66)
FM (IP 66)
II 2G EEx d IIC T6 II 1G EEx ia II C T6
EEx d IIC T6
cast Aluminium
ATEX (IP 66)
CENELEC (IP 66)
FM (IP 66)
NEMA 7/9
Weather proof
(IP 66)
II 2G EEx d IIC T6
II 1G EEx ia II C T6
EEx d IIC T6
NEMA 7/9
cast Iron
cast Alu.
cast Aluminium
cast Aluminium
cast Aluminium
cast Iron
cast Alu.
M20 x 1,5 3/4" NPT
M20 x 1,5 3/4" NPT
1" NPT
cast Aluminium
M20 x 1,5
1" NPT
M20 x 1,5
1" NPT
M20 x 1,5
1" NPT
1" NPT
M20 x 1,5
1" NPT
M20 x 1,5
1" NPT
M20 x 1,5
1" NPT
1 x SPDT
A2P
AAP
AHC
AAC
-
-
AK7
AU7
AKP
A2Q
AAQ
AH9
AA9
-
-
AK5
AU5
AKQ
1 x DPDT
A8P
ADP
AJC
ABC
-
-
AD7
AW7
ANP
A8Q
ADQ
AJ9
AB9
-
-
AD5
AW5
ANQ
1 x SPDT
32P
3AP
3HC
3AC
-
-
3K7
3U7
3KP
32Q
3AQ
3H9
3A9
-
-
3K5
3U5
3KQ
1 x DPDT
38P
3DP
3JC
3BC
-
-
3D7
3W7
3NP
38Q
3DQ
3J9
3B9
-
-
3D5
3W5
3NQ
1 x SPDT
B2P
BAP
BHC
BAC
-
-
BK7
BU7
BKP
B2Q
BAQ
BH9
BA9
-
-
BK5
BU5
BKQ
1 x DPDT
B8P
BDP
BJC
BBC
-
-
BD7
BW7
BNP
B8Q
BDQ
BJ9
BB9
-
-
BD5
BW5
BNQ
1 x SPDT
C2P
CAP
CHC
CAC
C2L
CAL
CK7
CU7
CKP
C2Q
CAQ
CH9
CA9
C2S
CAS
CK5
CU5
CKQ
1 x DPDT
C8P
CDP
CJC
CBC
C8L
CDL
CD7
CW7
CNP
C8Q
CDQ
CJ9
CB9
C8S
CDS
CD5
CW5
CNQ
1 x SPDT
-
-
-
-
-
-
-
-
-
D2Q
DAQ
DH9
DA9
-
-
DK5
DU5
DKQ
1 x DPDT
-
-
-
-
-
-
-
-
-
D8Q
DDQ
DJ9
DB9
-
-
DD5
DW5
DNQ
1 x SPDT
F2P
FAP
FHC
FAC
-
-
FK7
FU7
FKP
F2Q
FAQ
FH9
FA9
-
-
FK5
FU5
FKQ
1 x DPDT
F8P
FDP
FJC
FBC
-
-
FD7
FW7
FNP
F8Q
FDQ
FJ9
FB9
-
-
FD5
FW5
FNQ
1 x SPDT
-
-
-
-
-
-
-
-
-
H7A
HM2
HFC
HA9
-
-
HB3
HB4
HM3
1 x DPDT
-
-
-
-
-
-
-
-
-
H7C
HM6
HGC
HB9
-
-
HB7
HB8
HM7
1 x SPDT
U2P
UAP
UHC
UAC
U2L
UAL
UK7
UU7
UKP
U2Q
UAQ
UH9
UA9
U2S
UAS
UK5
UU5
UKQ
1 x DPDT
U8P
UDP
UJC
UBC
U8L
UDL
UD7
UW7
UNP
U8Q
UDQ
UJ9
UB9
U8S
UDS
UD5
UW5
UNQ
-
-
-
-
-
VFS
VHS
-
-
-
-
-
-
-
V5S
VBS
-
-
-
1 x SPDT
W2P
WAP
WHC
WAC
W2L
WAL
WK7
WU7
WKP
W2Q
WAQ
WH9
WA9
W2S
WAS
WK5
WU5
WKQ
WNQ
1 x DPDT
-
-
-
-
-
-
-
-
-
W8Q
WDQ
WJ9
WB9
W8S
WDS
WD5
WW5
1 x SPDT
X2P
XAP
XHC
XAC
X2L
XAL
XK7
XU7
XKP
X2Q
XAQ
XH9
XA9
X2S
XAS
XK5
XU5
XKQ
1 x DPDT
-
-
-
-
-
-
-
-
-
X8Q
XDQ
XJ9
XB9
X8S
XDS
XD5
XW5
XNQ
Select electric switch mechanism & enclosure for T67 models (see page 3 for switch ratings)
All models with material code A
Weather proof
(IP 66)
qty and
switch
type
A
3
B
C
D
F
U
W
X
cast Aluminium
All models with material codes B and D
ATEX (IP 66)
CENELEC (IP 66)
FM (IP 66)
II 2G EEx d II C T6 II 1G EEx ia II C T6
EEx d II C T6
NEMA 7/9
cast Iron
cast Alu.
M20 x 1,5 3/4" NPT
1" NPT
M20 x 1,5
1" NPT
M20 x 1,5
1" NPT
M20 x 1,5
1" NPT
cast Aluminium
cast Aluminium
Weather proof
(IP 66)
cast Aluminium
ATEX (IP 66)
CENELEC (IP 66)
FM (IP 66)
II 2G EEx d II C T6 II 1G EEx ia II C T6
EEx d II C T6
NEMA 7/9
cast Iron
cast Alu.
M20 x 1,5 3/4" NPT
1" NPT
cast Aluminium
cast Aluminium
M20 x 1,5
1" NPT
M20 x 1,5
1" NPT
M20 x 1,5
1" NPT
2 x SPDT
A4A
ABA
ALC
ADC
-
-
AL7
AV7
ALA
A4B
ABB
AL9
AD9
-
-
AL5
AV5
ALB
2 x DPDT
A1A
AEA
APC
AGC
-
-
AO7
AY7
AOA
A1B
AEB
AP9
AG9
-
-
AO5
AY5
AOB
2 x SPDT
34E
3BA
39E
3DE
-
-
3L7
3V7
3LE
34B
3BB
3L9
3D9
-
-
3L5
3V5
3LB
2 x DPDT
31A
3EA
3PC
3GC
-
-
3O7
3Y7
3OA
31B
3EB
3P9
3G9
-
-
3O5
3Y5
3OB
2 x SPDT
B4A
BBA
BLC
BDC
-
-
BL7
BV7
BLA
B4B
BBB
BL9
BD9
-
-
BL5
BV5
BLB
2 x DPDT
B1A
BEA
BPC
BGC
-
-
BO7
BY7
BOA
B1B
BEB
BP9
BG9
-
-
BO5
BY5
BOB
2 x SPDT
C4A
CBA
CLC
CDC
C4X
CBX
CL7
CV7
CLA
C4B
CBB
CL9
CD9
C4T
CBT
CL5
CV5
CLB
2 x DPDT
C1A
CEA
CPC
CGC
C1X
CEX
CO7
CY7
COA
C1B
CEB
CP9
CG9
C1T
CET
CO5
CY5
COB
2 x SPDT
D4B
DBB
DL9
DD9
-
-
DL5
DV5
DLB
D4B
DBB
DL9
DD9
-
-
DL5
DV5
DLB
2 x DPDT
D1B
DEB
DP9
DG9
-
-
DO5
DY5
DOB
D1B
DEB
DP9
DG9
-
-
DO5
DY5
DOB
2 x SPDT
FFA
FBA
FLC
FDC
-
-
FL7
FV7
FLA
FFB
FBB
FL9
FD9
-
-
FL5
FV5
FLB
2 x DPDT
FHA
FEA
FPC
FGC
-
-
FO7
FY7
FOA
FHB
FEB
FP9
FG9
-
-
FO5
FY5
FOB
2 x SPDT
U4A
UBA
ULC
UDC
U4X
UBX
UL7
UV7
ULA
U4B
UBB
UL9
UD9
U4T
UBT
UL5
UV5
ULB
2 x DPDT
U1A
UEA
UPC
UGC
U1X
UEX
UO7
UY7
UOA
U1B
UEB
UP9
UG9
U1T
UET
UO5
UY5
UOB
2 x SPDT
W4A
WBA
WLC
WDC
W4X
WBX
WL7
WV7
WLA
W4B
WBB
WL9
WD9
W4T
WBT
WL5
WV5
WLB
2 x DPDT
W1B
WEB
WP9
WG9
W1T
WET
WO5
WY5
WOB
W1B
WEB
WP9
WG9
W1T
WET
WO5
WY5
WOB
2 x SPDT
X4A
XBA
XLC
XDC
X4X
XBX
XL7
XV7
XLA
X4B
XBB
XL9
XD9
X4T
XBT
XL5
XV5
XLB
2 x DPDT
X1B
XEB
XP9
XG9
X1T
XET
XO5
XY5
XOB
X1B
XEB
XP9
XG9
X1T
XET
XO5
XY5
XOB
P H Y S I C A L S P E C I F I C AT I O N S
Description
Measured variable
Physical range
Process temperature
T62/T67 models
Process pressure
(for higher ratings
T64 models
consult factory)
Cage and process connection material
Float
Trim
Wetted materials
Magnetic sleeve
Specification
Liquid level / interface level
Standard models: min S.G. 0,40
Up to 34,5 bar (500 psi) @ 40 °C (100 °F)
Up to 400 °C (750 °F) @ 20,7 bar (300 psi)
Up to 82,7 bar (1200 psi) @ 40 °C (100 °F)
Up to 400 °C (750 °F) @ 51,7 bar (750 psi)
Carbon steel or stainless steel (others at request)
316 SST (1.4401) – T62/T67; 304 SST (1.4301) – T64
316 SST (1.4401)
316 SST (1.4401), or 400 series SST
E L E C T R I C A L S P E C I F I C AT I O N S
Description
Specification
Switch ratings
Up to 15 A @ 240 V AC (depending on switch mechanism)
Up to 10 A @ 120 V DC (depending on switch mechanism)
Single or dual SPDT or DPDT contacts (single contacts or single pneumatic
for T62/T64 models, dual contacts for T67 models)
Dry contact with standard or gold alloy contacts, Mercury, Hermetically sealed,
Hermetically sealed with gold or silver plated contacts, Proximity switch,
or single pneumatic bleed and non bleed
ATEX II 2G EEx d II C T6, explosion proof
ATEX II 1G EEx ia II C T6, intrinsically safe
CENELEC EEx d II C T6, explosion proof
FM/CSA/SAA, explosion proof
LRS, Lloyds Register of Shipment (marine applications)
GOST/GOSGORTECHNADZOR, Russian Authorisation standards
Other approvals are available, consult factory.
M20 x 1,5 ISO, 1" NPT and 3/4" NPT (or others at request)
Signal Output
Switch Types (see table on page 3)
Approvals (see table on page 1)
Cable entries
ELECTRICAL CONNECTION
Hazardous
area
Safe area
Hazardous
area
Safe area
I.S.
Power
Relay
Power
7
DIMENSIONS in mm (inches)
X
X
Y
Y
V
Z
V
Z
W
W
78*
(3.07)
X
78*
(3.07)
Y
124 (4.88)
114 (4.50)
219 (8.62)
Z
this dimension
equals float,
+ stem length,
minus 66
(2.60)
model T62/T67 threaded
V
this dimension
equals float,
+ stem length,
minus 76
(3.00)
229 (9.00)
W
model T62/T67 flanged
90*
(3.54)
min level
differential
32 (1.25)
137 (5.39)
267 (10.50)
267 (10.50)
* Dimensions for all housings, except for cast iron
housing, add for these 76 mm (3")
Housing type
Models
WeatherproofFM (NEMA 7/9) ATEX (Cast Alu)
CENELEC (Cast Iron)
model T64 flanged
V
W
mm
inches
T62/T64 with HS-switch
and T67
257
10.12
T62/T64 excl. HS-switch
202
7.94
All
249
T62/T64
165
Pneumatics
Switch Module J
Pneumatics
Switch Module K
øX
Y
Z
mm
inches
mm
inches
mm
inches
42
1.66
151
5.93
109
4.29
M20 x 1,5 (*) or 1" NPT
(2 entries - 1 plugged)
(*) not for FM (NEMA 7/9)
9.80
45
1.77
143
5.63
110
4.33
M20 x 1,5 or 3/4" NPT
(single entry - 2 entries at request)
110
4.33
6.50
39
1.54
118
4.65
130
5.12
1/4" NPT
Allow 200 mm (7.87") overhead clearance / All housings are 360 ° rotatable
QUALITY ASSURANCE - ISO 9001
THE QUALITY ASSURANCE SYSTEM IN PLACE AT MAGNETROL GUARANTEES THE HIGHEST LEVEL OF QUALITY DURING THE DESIGN,
THE CONSTRUCTION AND THE SERVICE OF CONTROLS.
OUR QUALITY ASSURANCE SYSTEM IS APPROVED AND CERTIFIED TO ISO 9001 AND OUR TOTAL COMPANY IS COMMITTED TO PROVIDING FULL CUSTOMER SATISFACTION BOTH IN QUALITY PRODUCTS AND QUALITY SERVICE.
PRODUCT WARRANTY
ALL MAGNETROL MECHANICAL LEVEL CONTROLS ARE WARRANTED FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR FIVE
FULL YEARS FROM THE DATE OF ORIGINAL FACTORY SHIPMENT.
IF RETURNED WITHIN THE WARRANTY PERIOD; AND, UPON FACTORY INSPECTION OF THE CONTROL, THE CAUSE OF THE CLAIM IS DETERMINED TO BE COVERED
UNDER THE WARRANTY; THEN, MAGNETROL INTERNATIONAL WILL REPAIR OR REPLACE THE CONTROL AT NO COST TO THE PURCHASER (OR OWNER) OTHER THAN
TRANSPORTATION.
MAGNETROL SHALL NOT BE LIABLE FOR MISAPPLICATION, LABOR CLAIMS, DIRECT OR CONSEQUENTIAL DAMAGE OR EXPENSE ARISING FROM THE INSTALLATION
OR USE OF THE EQUIPMENT. THERE ARE NO OTHER WARRANTIES EXPRESSED OR IMPLIED, EXCEPT, SPECIAL WRITTEN WARRANTIES COVERING SOME MAGNETROL PRODUCTS.
BULLETIN N°:
EFFECTIVE:
SUPERSEDES:
UNDER RESERVE OF MODIFICATIONS
Heikensstraat 6, 9240 Zele, België
Tel. +32 (0)52.45.11.11 • Fax. +32 (0)52.45.09.93 • E-Mail: [email protected]
DEUTSCHLAND
Schloßstraße 76, D-51429 Bergisch Gladbach-Bensberg
Tel. 02204 / 9536-0 • Fax. 02204 / 9536-53 • E-Mail: [email protected]
FRANCE
Le Vinci 6 - Parc d’activités de Mitry Compans, 1, rue Becquerel, 77290 Mitry Mory
Tél. 01.60.93.99.50 • Fax. 01.60.93.99.51 • E-Mail: [email protected]
ITALIA
Via Arese 12, I-20159 Milano
Tel. (02) 607.22.98 (R.A.) • Fax. (02) 668.66.52 • E-Mail: [email protected]
UNITED
KINGDOM
Unit 1 Regent Business Centre, Jubilee Road Burgess Hill West Sussex RH 15 9TL
Tel. (01444) 871313 • Fax (01444) 871317 • E-Mail: [email protected]
INDIA
B4/115 Safdurjung Enclave, New Delhi 110 029
Tel. 91 (11) 6186211 • Fax 91 (11) 6186418 • E-Mail: [email protected]
www.magnetrol.com
BENELUX
OUR NEAREST REPRESENTATIVE
BE 44-116.12
MARCH 2002
March 1998