December 13th 2012 Page | 1 Characterization of Vibration Withstanding Characteristics of Surface Mount (SMT) Aluminum Electrolytic Capacitors Case Sizes (D x H) : 8x10.5, 8x10.8, 10x10.5, 10x10.8, 10x12.8, 12.5x14, 16x17 & 18x17.5 Test method JIS C 5102 * AEC Q 200 ** 1.5mm max. 5G max. or 1.5mm max. whichever is smaller Peak acceleration Total amplitudes Vibration‐Proof Test *** 10G 20G 30G 1.5mm max. 1.5mm max. 5mm max. Frequency 10 to 55 Hz (1 min.) 10 to 2,000 Hz (20 min.) 5 to 2,000 Hz (20 min.) Direction / Duration of vibration 2 hrs each for X,Y,Z, Total 6 hrs 4 hrs each for X,Y,Z, Total 12 hrs 2 hrs each for X,Y,Z, Total 6 hrs Two Terminal (T2) ○ ‐ ‐ ‐ X X X T2 with YF Suffix Part Number ○ ○ X X X Wide Terminal (WT) ○ ○ ○ ○ ○ * ‐ See Attachment “C” ** ‐ See Attachment “B” *** ‐ Internally developed test, see Attachment “A” ‐ ( Note: 18x22WT size under development to meet 30G test) Two Terminals (T2) T2 with YF Suffix Part Number Wide Terminal (WT) Prepared by TPMG / [email protected] www.NICcomp.com | I S O 9 0 0 1 : 2 0 0 8 Registered | Technical Support: [email protected] Attachment “A” ‐ Vibration Test & Profile 30G Test (Internally determined method) Number of test sample Frequency Total amplitudes Peak acceleration Direction and Duration of Vibration Thickness of solder paste Acceleration Max.30G 5 0.25 5 10 1.01 5 20 4.03 5 30 9.06 5 40 16.11 5 50 25.18 5 54.58 30.02 5.00 60 30 4.14 80 30 2.33 100 30 1.49 300 30 0.165 500 30 0.060 700 30 0.030 1000 30 0.015 1200 30 0.010 1400 30 0.0076 1600 30 0.0058 1800 30 0.0046 2000 30 0.0037 Page | 2 5 to 2,000 Hz (20 minute per sweep) 5mm max. 30G X, Y, Z axis direction for 2 hrs each, with a total of 6 hrs 0.20±0.03mm Amplitude (p‐p) Max. 5mm Acceleration G & Ap‐p vs Frequency 30G Test Amplitude(mm) or Acceleration (G) Frequency n=20 100 G 10 1 Ap‐p 0.1 0.01 0.001 Single Sweep 0.0001 1 10 100 1000 Frequency(Hz) www.NICcomp.com | I S O 9 0 0 1 : 2 0 0 8 Registered | Technical Support: [email protected] 10000 Attachment “B” ‐ Vibration Test & Profile AEC Q200 Ver. C / 5 G Test Number of test sample Frequency 10 to 2,000 Hz (20 minute per sweep) Page | 3 Total Amplitude Peak acceleration 1.5mm max. or Acceleration 5G max. whichever smaller Direction and Duration of Vibration X, Y, Z axis direction for 4 hrs each, with a total of 12 hrs Thickness of solder paste Acceleration Max. 5G Amplitude (p‐p) max. 1.5mm 10 0.30 1.5 20 1.21 1.5 30 2.72 1.5 40 4.83 1.5 40.68 5.00 1.5 50 5 0.993 60 5 0.690 80 5 0.388 100 5 0.248 300 5 0.0276 500 5 0.0099 700 5 0.0051 1000 5 0.0025 1200 5 0.0017 1400 5 0.0013 1600 5 0.0010 1800 5 0.0008 2000 5 0.0006 0.20±0.03mm Acceleration G & Ap‐p vs. Frequency AEC‐Q200 5G Test 100 Amplitude(mm) or Acceleration (G) Frequency n=30 10 G 1 Ap‐p 0.1 0.01 0.001 Single Sweep 0.0001 1 10 100 1000 Frequency(Hz) www.NICcomp.com | I S O 9 0 0 1 : 2 0 0 8 Registered | Technical Support: [email protected] 10000 Attachment “C” ‐ Vibration Test & Profile JIS C5102 8.2 Number of test sample Frequency Total Amplitude Peak acceleration Direction and Duration of Vibration Thickness of solder paste n=10 10 to 55 Hz (1 minute per sweep) Page | 4 1.5mm max / See Acceleration (G) table below X, Y, Z axis direction for 2 hrs each, with a total of 6 hrs 0.20±0.03mm Frequency Acceleration (G) Amplitude (p‐p) max. 1.5mm Acceleration G & Ap‐p vs. Frequency JIS C5102 Test 10 0.30 1.5 15 0.68 1.5 20 1.21 1.5 25 1.89 1.5 30 2.72 1.5 35 3.70 1.5 40 4.83 1.5 40.68 5.00 1.500 45 6.12 1.226 50 7.55 0.993 55 9.14 0.821 Amplitude(mm) or Acceleration(G) 100 G 10 1 Ap‐p 0.1 0.01 0.001 Single Sweep 0.0001 1 10 100 1000 Frequency(Hz) www.NICcomp.com | I S O 9 0 0 1 : 2 0 0 8 Registered | Technical Support: [email protected] 10000