Data Sheet - Carling Technologies

V-Series
Contura II & III
Switches
The V-Series Contura II & III snap-in rocker switches
offer countless unique options including choices for
ratings, circuits, colors, illuminations and symbols.
These single or double pole switches feature
removable actuators in a choice of actuator styles
and colors, and can be illuminated with either
square or bar shaped lenses. Actuators may be
purchased and stocked separately. An optional
plug-in terminal connector enables pre-wiring of
wire harnesses.
The Contura switches with sealed option, are
certified to IP66 and IP68, signifying complete
protection against dust and prolonged spray and
submersion under pressure, and are recognized to
UL1500 - Ignition Protection for Marine Products.
These switches are vibration, shock, thermoshock,
moisture and salt spray resistant. Temperature
ratings range from -40°C to +85°C.
Resources:
Download 3D CAD Files
IGS
STP
Watch Product Video
Carling Technologies, Inc.
60 Johnson Avenue, Plainville, CT 06062
Email: [email protected]
Application Support: [email protected]
Phone: (860) 793-9281 • Fax: (860) 793-9231
www.carlingtech.com
Product Highlights:
Countless options for ratings, circuits, colors,
illuminations and legends
ŠŠ Certified to IP66 and IP68 for front panel components
ŠŠ Vibration, shock, thermoshock, moisture and salt spray resistant
ŠŠ Temperature range from -40°C to +85°C.
ŠŠ
Typical Applications:
On/Off Highway Equipment
ŠŠ Marine
ŠŠ Military Armored Vehicles
ŠŠ Mining Machinery and Equipment
ŠŠ Any application requiring environmental protection
ŠŠ
2 | V-Series Contura Sealed Rocker Switches
V-Series Switch
DESIGN FEATURES
INTERCHANGEABLE ACTUATORS
Panel redesign is a snap with our wide
range of rocker styles. Achieve maximum
design variety with minimum inventory.
Simply swap rockers to create an entirely
new look for your panel.
OPTIONAL PANEL SEAL
Prevents water/dust
ingress behind panel.
DUAL SEAL PROTECTION
Seals out water, dust,
debris, and enables switch
certification to IP66/IP68 for
front panel components.
MULTIPLE LIGHTING OPTIONS
In addition to incandescent
lamps, our LED illumination is
offered in a wide array of light
intensities, colors, as well as
dual level, tri-color, and flashing
options.
CLEAN CONNECTIONS
Options for both eight and ten
terminal base styles with AMP &
Packard compatible connectors
affords myriad circuit options
while providing ease of assembly.
BRASS ROLLER PIN
Robust mechanism
eliminates the need for
lubricants. Enables switch
to withstand -40°C to
+85°C temperatures.
SILVER PLATED BUTT
CONTACT MECHANISM
Providing 50K to 100K
electrical cycles and
a variety of different
electrical ratings.
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
V–Series Contura Sealed Rocker Switches - General Specifications | 3
Electrical
Contact Rating .4VA @ 24VDC (MAX) resistive
15 amps, 125VAC
10 amps, 250VAC
1/2 HP 125-250VAC
20 amps, 4-14VDC
15 amps, 15-28VDC
10A, 14VT
6A, 125VAC L
Dielectric Strength 1500 Volts RMS
Insulation Resistance 50 Megohms
Initial Contact Resistance 10 milliohms max. @ 4VDC
Life 50,000- 100,000 cycles circuit
dependent
Contacts Silver alloy, silver tin-oxide, fine silver
Terminals Brass or copper/silver plate 1/4”
(6.3mm) Quick Connect terminations standard. Solder lug, Wire Lead
Mechanical
Endurance Physical
150,000 cycles minimum
circuit dependent
Lighted Incandescent - rated 10,000 hours Neon - rated 25,000 hours
LED - rated 100,000 hours 1/2 life
(LED is internally ballasted for
voltages to 24VDC)
Seals Internal
Optional external gasket panel seal
Base Polyester blend rated to 125°C with
a UL flammability rating of 94V0.
Contura II,III,IV,V,
Hard Surface: Basic actuator VI, VII Actuator
structure molded of thermoplastic
polycarbonate with a hard Nylon 66 thermoplastic surface overlay.
Soft Surface: Basic actuator structure
molded of thermoplastic polycarbonate
with an elastomer overlay.
Contura X,XI,XII Actuator,VP Nylon 66 Reinforced rated to 105°C
Lens Polycarbonate rated at 100°C
Contura XIV
Polycarbonate lens/subrocker with ABS shell
Actuator Travel (Angular Displacement)
2 position 3 positions 18°
9° from center
Mounting Specifications
.830[21.08]
Panel Thickness Range
Gaskets Acceptable Panel Thickness
0
.030 to .250 (.76mm to 6.35mm)
TEST CUT
1.450[36.83] HOLE IN
1
.030 to .109 & .147 to .157
ACTUAL
MATERIAL
(.76 to 2.77mm & 3.73 to 3.98mm)
Recommended: No gasket with panel
SWITCH
thickness of .032, .062, .093, .125,.187 or .250
MOUNTING HOLE
Agency Certifications
Environmental
Sealing Sealed version: IP68, in accordance
with IEC 60529, BS 5490, DIN 40050 & NFC 20 010. This rating applies to front panel components of the actual
switch only, and signifies protection
against dust and the prolonged effects of immersion under pressure.
The standard test for immersion
under pressure requires submersion
under one meter of water for 30 min.
The V-Series switch has exceeded
these parameters, having
been actuated and illuminated during
submersion.
Corrosion Mixed Flowing Gas (MFG) Class III
3 year accelerated exposure per ASTM B-827, B-845 Silver and gold contacts
Operating Temp. -40°C to +85°C
Vibration 1 Per Mil-Std 202F, Method 204D
Test Condition A 0.06 DA or 10G’s
10-500 Hz. Tested with VCH connector.
Test criteria - No loss of circuit during
test, pre and post test contact resistance.
Vibration 2 Resonance search
24-50 Hz 0.40 DA
50-2000 Hz ±10 G’s peak
Horizontal Axis 3-5 G’s max.
Random
24 Hz 0.06 PSD-Gsq/Hz
60 Hz 0.50
100 Hz 0.50
200 Hz 0.025
2000 Hz 0.025
No loss of circuit during test; <10μ
seconds chatter.
Shock Per Mil-Std 202F, Method 213B, Test
Condition K @ 30G’s. Tested with
VCH connector. Test criteria - No loss
of circuit during test, pre and post
test contact resistance.
Salt Spray Per Mil-Std 202F, Method 101D, Test
Condition A, 96 Hrs. Sealed version only.
Dust Per Mil-Std 810C, Method 510.2 Air
Velocity 300 ±200 Feet/Min, Test
Duration 16 Hrs.
Thermal Shock Per Mil-Std 202F, Method 107F, Test
Cond. A, -55°C to +85°C. Test criteria pre and post test contact resistance
Moisture Resistance Per Mil-Std 202F, Method 106F, Test
Criteria - pre and post test contact
resistance
Ignition Protection All Contura switches with sealed
construction meet the requirements
of UL1500/ISO8846 for ignition
protection, in addition to
conformance with EC directive
94/25/EC for marine products.
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
4 | V–Series Contura II, III
Dimensional Specifications: in. [mm]
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
V-Series Contura II to XIV - Circuit Diagram | 5
CIRCUIT
CIRCUIT DIAGRAM
CIRCUIT
CIRCUIT DIAGRAM
3
1
3
2
3
5
3
3
3
1
2
5
3
4
6
2
2
1
3
4
2
6
4
5
6
5
SYMBOL LEGEND
2
5
3
4
DEFINITION
DESIGNATES TERMINALS AND CONTACTS
DESIGNATES LAMP LOCATION
DESIGNATES MAINTAINED CIRCUITS
DESIGNATES OTHER POSITION
H
2
5
3
2
SYM.
3
8
6
6
G
1
3
1
6
3
3
2
1
S
2
7
6
5
2
F
1
5
2
5
3
1
2
6
R
2
6
4
3
5
E
3
6
M
D
1
4
5
3
1
6
2
5
3
L
2
3
5
2
5
C
1
1
6
2
4
6
K
2
3
4
2
B
1
3
J
2
3
CIRCUIT DIAGRAM
1
6
A
2
CIRCUIT
DESIGNATES MOMENTARY CIRCUITS
DESIGNATES TWO POSITION CONNECTION
2
5
DESIGNATES EXTERNAL JUMPER PROVIDED
BY CUSTOMER
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
6 | V-Series Contura II to XIV - Circuit Diagram
LAMP
CIRCUIT
CIRCUIT DIAGRAM
LAMP
CIRCUIT
+8
+8
A/1
F/6
1
G/7
2
M/R
2
J/8
+1 +3 -4
SPECIAL
#3
+6
1
2
N/T
+8
-6
2
1
SPECIAL
#4
1
+3
2
-7
+3
+6
1
-7
2
-7
-8
2
+1 +3 -4
P/V
2
-6
1
2
-7
+8
+1 +3
1
2
K/W
CIRCUIT DIAGRAM
1
U/Y
2
(-)7
CIRCUIT DIAGRAM
3
1
+6
1
-7
3
17 18 10(-)
J1
1
1
2
5
2
3 14
3 14
5
CIRCUIT DIAGRAM
CIRCUIT
CIRCUIT
10(-)
J5
J5
1
3
5
1
3
5
3
1
6 16
6 16
JK
8
17 18 10(-)
SYMBOL LEGEND
SYM.
SYMBOL
LEGENDDEFINITION
1
1
J4
5
5
3 14 15 12
8
J4
2
3 14 15 12
3 14
JK
17 18 10(-)
3
11 13
1311
1
1
5
3 14
JJ
17 18 10(-)
5
NOTE:
J circuits are available for
all non-locking V-Series
styles. Consult factory for
p /n details.
6
11 13
13 11
8
J3
3
6
3 14
JJ
1
2
3 14
5
8
17 18 10(-)
5
-9
8
J3
2
-7
8
5
1
5
2
JA
1
J2
1
JA
17 18 10(-)
J2
+10
CIRCUIT DIAGRAM
13 11
2
+8
CIRCUIT DIAGRAM
11 13
17 18
2
2
17 18 10(-)
CIRCUIT
17 18
3
2
8
8
CIRCUIT
CIRCUIT DIAGRAM
10(-) 1
17 18 10(-)
J1
2
2
-7
1
+6
1
+8
-6
+3
2
+1 +3
1
SPECIAL
#1
+3
H/Z
-7
13 11
+3
1
+8
C/3
11 13
L/9
CIRCUIT DIAGRAM
-6
-7
+3
CIRCUIT
+3
LAMP
CIRCUIT
-7
1
-7
CIRCUIT
-6
2
+8
1
E/5
CIRCUIT DIAGRAM
-7
+3
D/4
+3
1
-7
B/2
LAMP
CIRCUIT
CIRCUIT DIAGRAM
SYM.
CIRCUIT
DESIGNATES TERMINALS AND CONTACTS
DEFINITION
DESIGNATES LAMP LOCATION
DESIGNATES TERMINALS AND CONTACTS
DESIGNATES LAMP LOCATION
JA,JJ,JK
J1,J3,J4,J5
J2
CONNECTOR PART #
JC1-01
JC2-01
JC3-01
DESIGNATES TWO POSITION CIRCUIT
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
V-Series Contura II & III Sealed Rocker Switches - Ordering Scheme | 7
V 1 D A B T 0 B
1
Series
2
Circuit
4
5
6
Termination Illumination Lamp
3
Rating
7
Lamp
A R B 00
8
Bracket
9
Actuator
Terminal Connections as viewed from bottom of switch:
8 terminal 10 terminal
8 - - 7
8 - - 7
1 - - 4
1 - - 4
2 - - 5
2 - - 5
3 - - 6
3 - - 6
10 - - 9
Position:
0 00
13
14
Legend
Actuator
Orientation Lens Legend
No lamp
0
Neon
1 125VAC 2 250VAC
Incandescent 4 3V
5 6V
6 12V
7 18V
8 24V
LED*
superbrightsuperbright
Red
AmberGreen Red
2VDC
A LF R
6VDC
B MG S
12VDC
C NH T
24VDC
D PJ V
( ) - momentary
SP - single pole - uses terminals 1, 2 & 3.
DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
Terminals 7, 8, 9 & 10 for lamp circuit only.
1
2
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
3
SPDP
2 & 3, 5 & 6 Connected Terminals
1 & 2, 4 & 5
1A
ONNONE OFF
2B
(ON)NONE OFF
3C
ONNONE(OFF)
4D
ONNONE ON
5F
ONNONE (ON)
6J
ONOFF ON
7K
ONOFF (ON)
8L
(ON)OFF (ON)
SPECIAL CIRCUITS
2 & 3, 5 & 4
5&4
H*
2 & 3
2 & 3
OFF
G*
2 & 3, 5 & 6
2 & 3
1&2
S*
2 & 3, 5 & 6
2 & 3
OFF
M*
(2 & 3, 5 & 6)
2 & 3
2&1
R*
(2 & 3, 5 & 6)
E*
5 & 6
5 & 3
5&1
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit
E may be used for SP OFF-ON-ON circuit.
8 FLUSH BRACKET COLOR1, PANEL SEAL
Black
No SealB
One SealC
5 ILLUMINATION
3,6
Actuator orientation above terminals:
1,4
10 LENS
0 - No Actuator Z - No Lens
ClearWhite Amber Green
1
6
8
G
2
7
C
H
3
8
D
J
4
9
E
K
5
A
F
L
.4VA @ 28VDC Resistive
15A 24V
20A 18V
20A 12V
20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
10A 14V, 6A 14VT (circuit G only)
.4VA/20A 12V
.4VA/15A 24V
4 TERMINATION/BASE STYLE
Gray
G
H
0
No Actuator
A, B Contura II
C, D Contura III
3 RATING
8 term 10 Term
Termination
12
.250 TAB (QC) no barriers
AB
.250 TAB (QC) with barriers
JK
.250 TAB (QC) no barriers
35
Solder Lug no barriers
CD
Solder Lug
56
Wire Leads no barriers
EF
Wire Leads
Note: Codes J & K for circuits H, G & M.
White
W
Y
9 ACTUATOR
3
1
B
C
D
E
F
M
N
12
Legend
Selection 6: above terminals 1 & 4; Selection 7: above terminals 3 & 6
2 CIRCUIT
11
Color
6,7 LAMP (SAME CODING FOR BOTH SELECTIONS)
1 SERIES
V
10
Lens
Red
M
N
P
R
S
Blue
T
U
V
W
Y Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
11 ACTUATOR COLOR1 AND TEXTURE
Jumper
No
No
Yes T2 to 5
No
No
No
No
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Sealed Unsealed
Lamps
Illumination Type Lamp wired to Terminals
S
0
NONE –
–
A
1
1
INDEPENDENT 8 (+) 7 (–)
B
2
1
DOWN 3 (+) 7 (–)
C
3
2
UP 3 (+) 7 (–)
D
4
1
DOWN 3 (+) 7 (–)
2
DOWN
1 (+) 7 (–)
E
5
1
UP 1 (+) 7 (–)
2
UP
3 (+) 7 (–)
F
6
1
INDEPENDENT 8 (+) 7 (–)
2
UP
3 (+) 6 (–)
G
7
1
INDEPENDENT 8 (+) 7 (–)
2
UP 3 (+) 7 (–)
H
Z
2
INDEPENDENT 8 (+) 7 (–)
U
Y
1
INDEPENDENT 8 (+) 7 (–)
2
INDEPENDENT 10 (+) 9 (–)
SINGLE POLE SWITCHES ONLY
J8
1
DOWN
3 (+) 8 (–)
2
INDEPENDENT
6 (+) 7 (–)
KW
1
INDEPENDENT
8 (+) 7 (–)
2
INDEPENDENT
6 (+) 7 (–)
DOUBLE POLE SWITCHES ONLY
L9
1
DOWN
3 (+) 6 (–)
MR
1
UP
3 (+) 6 (–)
NT
1
DOWN
3 (+) 6 (–)
2
DOWN
1 (+) 4 (–)
PV
1
UP
1 (+) 4 (–)
2
UP
3 (+) 6 (–)
0 - No Actuator
BlackGray Red
White
Soft Surface
BGRW
Hard Surface
CHSY
12 ACTUATOR LENS OR BODY LEGENDS2
11ON 12 OFF 13 I
14O
OFF ONO I
15 O O 16 O O
F N N F
FF
17 O I
18 I O
For additional legend options & codes, visit us at www.carlingtech.com.
13 LEGEND ORIENTATION
0
1
2
3
4
No legend (used with codes 11-18 in selection 12)
Orientation 1
Orientation 2
Orientation 3
Orientation 4
14 ACTUATOR LENS LEGEND
00
No legend this location / no actuator
(used with codes 11-18 in selection 12) Selection 14 required when switch requires two
legends. If the two legends consist of one lens and one body legend, lens legend must
be specified in selection 12; body legend specified in selection 14.
For legend options & codes, visit us at www.carlingtech.com.
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 Body legends not available on Soft surface actuators; White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators. Custom colors are available, consult factory.
3 Additional ratings available. See V-Series Switch Accessories page.
4 Contura II available with two square lenses. Consult factory for details.
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
8 | V-Series Contura II & III Locking Sealed Rocker Switches - Ordering Scheme
V 1 D A S W 0 B
1
Series
2
Circuit
4
5
6
Termination Illumination Lock
3
Rating
7
Lamp
1 SERIES
V
Terminal Connections as viewed from bottom of switch:
8 terminal 10 terminal
8 - - 7
8 - - 7
1 - - 4
1 - - 4
2 - - 5
2 - - 5
3 - - 6
3 - - 6
10 - - 9
( ) - momentary
SP - single pole - uses terminals 1, 2 & 3.
DP - double pole uses terminals 1, 2, 3, 4, 5 & 6.
Terminals 7, 8, 9 & 10 for lamp circuit only.
1
2
3
SPDP
2 & 3, 5 & 6 Connected Terminals
1 & 2, 4 & 5
1A
ONNONE OFF
4D
ONNONE ON
5F
ONNONE (ON)
6J
ONOFF ON
7K
ONOFF (ON)
8L
(ON)OFF (ON)
9N
OFFNONE ON
SPECIAL CIRCUITS
2 & 3, 5 & 4
5&4
H*
2 & 3
2 & 3
OFF
G*
2 & 3, 5 & 6
2 & 3
1&2
S*
2 & 3, 5 & 6
2 & 3
OFF
M*
(2 & 3, 5 & 6)
2 & 3
2&1
R*
(2 & 3, 5 & 6)
E*
5 & 6
5 & 3
5&1
*Jumper between terminals 2 & 5 for circuits H,G,M,R & S are specified in selection 4.
External jumper between terminals 2 & 4 for circuit E are provided by customer. Circuit
E may be used for SP OFF-ON-ON circuit.
11
Function
0
12
Legend
13
Legend
Orientation
3 RATING
.4VA @ 28VDC Resistive
15A 24V
20A 18V
20A 12V
20A 14V, 10A 14VT (circuit 1, 4 , A & D only)
10A 14V, 6A 14VT (circuit G only)
.4VA/20A 12V
.4VA/15A 24V
4 TERMINATION/BASE STYLE
8 term 10 Term
Termination
12
.250 TAB (QC) no barriers
AB
.250 TAB (QC) with barriers
JK
.250 TAB (QC) no barriers
35
Solder Lug no barriers
CD
Solder Lug
56
Wire Leads no barriers
EF
Wire Leads
Note: Codes J & K for circuits H, G & M.
No lamp
0
Neon
1 125VAC 2 250VAC
Incandescent 4 3V
5 6V
6 12V
7 18V
8 24V
LED*
superbrightsuperbright
Red
AmberGreen Red
2VDC
A LF R
6VDC
B MG S
12VDC
C NH T
24VDC
D PJ V
* Consult factory for “daylight bright” LED options. Typical current draw for LED is 20ma.
8 FLUSH BRACKET COLOR1, PANEL SEAL
Black
No SealB
One SealC
White
W
Y
Gray
G
H
9 HARD SURFACE ACTUATOR1
Contura II
BlackGray Red White
A BGH
Contura III
C DEF
3,6
Actuator orientation above terminals:
1,4
10 LENS
Z - No Lens
ClearWhite Amber Green Red Blue
3
8
D
J
P
V
4
1
B
C
D
E
F
M
N
10
Lens
Lamp above terminals 3 & 6 end of switch
Position:
9
Actuator
7 LAMP
2 CIRCUIT
A Z E 00
8
Bracket
Lens color for LEDs must be clear, white, or match color of LED.
Green or blue lenses are not recommended with Neon lamps.
11 ACTUATOR LOCK FUNCTION AND COLOR1
Jumper
No
No
Yes T2 to 5
No
No
No
No
5 ILLUMINATION & SWITCH SEALING
Lamp #1:above terminals 1 & 4 end of switch.; Lamp #2 above terminals 3 & 6 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only
Sealed Unsealed
Lamps
Illumination Type Lamp wired to Terminals
S
0
NONE –
–
C
3
2
UP 3 (+) 7 (–)
H
Z
2
INDEPENDENT 8 (+) 7 (–)
DOUBLE POLE SWITCHES ONLY
MR
1
UP
3 (+) 6 (–)
6 LOCK
Lock above terminals 1 & 4 end of switch.
Wlock
Lock Color Match Actuator
Black White Red
Safety Orange
Up
Down
Up & Down Center3
A
HR1
BJ S2
CKT 3
DL V4
E M W5
12 ACTUATOR LENS OR BODY LEGEND2
00 - No Legend
21
22
OFF ON
25 O
F
F
23
26 O
N
O
27 O
24
I
28 I
For additional legend options & codes, visit us at www.carlingtech.com.
ORIENTATION OF
ACTUATOR/LENS IN PANEL
13 LEGEND ORIENTATION
0
1
2
3
4
No legend (used with codes 21-28 in selection 12)
Orientation 1
Orientation 2
Orientation 3
Orientation 4
ORIENTATION 1
ORIENTATION 4
AZC45-1
45
ORIENTATION 2
AZC45-2
45
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 White imprinting is standard on black actuators; Black imprinting is standard on white, red and gray actuators. Custom colors are available, consult factory.
3 Only available with 3 position circuits. Center OFF and special circuits only available with center position lock function.
4 Additional ratings available. See V-Series Switch Accessories page.
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
ORIENTATION 3
V-Series Contura Sealed Rocker Switch Actuators Separately | 9
Reduce inventory levels and cost by stocking actuators and base switches separately.
Contura II, III, IV, V, VI, VII, X, XI, XII, XIV Base switches separately: specify V with code selections 2-8 in the ordering schemes.
Contura II, III, IV, V Actuator only: VV with code A or C for selection 9, & with selections 10-14 in the ordering schemes.
Contura VI Actuator with lenses and inserts only: VV with code selections 9-16
Contura II, III, IV, V, VII Actuator only: VV with code A, C, E, G, P or Z for selection 9 & with selections 10-14 in the ordering schemes.
Contura X, XI, XII, XIV actuators with lenses separately: VV with code selections 9-14 in the ordering schemes.
Panel Seal: VPS
Contura X & XI actuators without lenses separately:
VVR 6 1 00 1
1
Actuator Separately
4
Actuator
Legend
2
3
Actuator
Lens
Style/Color Opening
5
Legend
Orientation
2 ACTUATOR STYLE & COLOR
3 LENS OPENING FOR1
1
2
3
4
5
One bar lens
One bar lenses
One square lens
two square lens
15 O O 16 O O
F N
N F
F
F
17 O I
J Black
Z No lens
square lens on top/
bar lens on bottom
(Contura X only)
6
7
Legend
Legend
Orientation
5
Legend
N White
1 Bar lens
00 - No Legend
21
OFF
22
25 O
F
F
26 O
N
M Red
2 Square lens
5, 7 LENS OR BODY LEGEND2
14 O
I
23
ON
O
27 O
24
I
28 I
For additional legend options & codes, visit us at www.carlingtech.com.
18 I O
ORIENTATION OF
ACTUATOR/LENS IN PANEL
6 LEGEND ORIENTATION3
0 No legend
1 Orientation 1
2 Orientation 2
ORIENTATION OF
ACTUATOR/LENS IN PANEL
5 LEGEND ORIENTATION1
No legend
Orientation 1
Orientation 2
Orientation 3
Orientation 4
K Gray
3,4 LENS OPENING FOR
For additional legend options & codes, visit us at www.carlingtech.com.
0
1
2
3
4
4
Lens
Opening
3
Lens
Opening
2 ACTUATOR STYLE & COLOR
Red
4
9
4 ACTUATOR LENS OR BODY LEGEND
00 - No Legend this location
11 ON 12 OFF
13 I
OFF ON
O
2
Style &
Color
1 CONTURA XII ACTUATOR SEPARATELY
VVP
White
3
8
Gray
2
7
Black
1
6
VVP J 1 Z 21 1 00
1
Actuator
1 CONTURA X & XI ACTUATOR SEPARATELY
VVR
Contura X
Contura XI
Contura XII actuators without lenses separately:
ORIENTATION 2
Contura X, XI & XII actuator lens assembly separately:
ORIENTATION 1
ORIENTATION 4
ORIENTATION 1
VVL 2 1 00 0
ORIENTATION 2
1
Lens Separately
ORIENTATION 3
2
Lens
Style
4
Legend
3
Lens
Color
5
Legend
Orientation
1 CONTURA X, XI & XII LENS SEPARATELY
VVL
Contura X, XI & XII top piece of 2-piece lens separately:
VVT 1
1
Lens Separately
1 TOP OF LENS SEPARATELY
VVT
1 Clear
2 Smoke
3 White
Contura X, XI & XII actuator lens assembly:
top lens
actuator stem
posts mount toward actuator stem
bottom lens
}
two piece
lens assembly
1 piece lens/bar lens are positioned the same as bottom lens for assembly,
minus the top lens. Lenses snap in from bottom.
Notes:
1 If actuator lens opening for 2 bar or 2 square lenses, legend orientation 0,1, or 2
must be chosen.
2 Center of actuator marking not available for Contura XII.
3 Legend is not available for bar style lens.
4 Not recommended with neon lamps.
5 Must also order top piece of 2 piece square lens separately.
2 One Piece Square lens
3 Bottom of Two-Piece Square lens5
3 TRANSLUCENT LENS COLOR
1 Clear
2 COLOR
2
Color
2 LENS STYLE3
1 Bar lens
2 White
3 Amber
4 Green4
4 LENS OR BODY LEGEND2
00 - No Legend
21
OFF
22
25 O
F
F
26 O
N
ON
23
5 Red
O
27 O
24
6 Blue4
I
28 I
For additional legend options & codes, visit us at www.carlingtech.com.
ORIENTATION OF
ACTUATOR/LENS IN PANEL
5 LEGEND ORIENTATION3
0
1
2
3
4
No legend
Orientation 1
Orientation 2
Orientation 3
Orientation 4
ORIENTATION 1
ORIENTATION 4
ORIENTATION 2
ORIENTATION 3
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
10 | V-Series Contura Sealed Rocker Switch Accessories
Easily integrate Contura products into your system, with Contura Accessories
Q.C. SELECTION GUIDE
Contura ConnectorsPART NO
COMPANY
SERIES
WIRE
RANGE
Q.C.
SELECTION
TIN GUIDE
PLAIN
COMPANY
SERIES
ORIENTATION
MM 2
AWG
WIRE
RANGE
PLATED
BRASS
BRASS
PART NO
(REF)
12
3.0 ORIENTIN
2
TATION
PLAIN
02965471
AWG(2)16-14
PLATED
Q.C.
SELECTION
Q.C.12010601
SELECTION
GUIDE
Q.C.
SELECTION
GUIDE MM(2)1.0-2.0
GUIDE
BRASS
02965470BRASS
16-14 (REF) 1.0-2.0
02965580
PACKARD
58 SERIES
B
WIRE
WIRE
WIRE
PART
NO
PART
NO RANGE
PART 20-18
NO RANGE
02965580
12
3.0
02965469
06288318
.5-.8 RANGE
COMPANY
COMPANY
ORIENORIENORIEN12010601
02965471 COMPANY
(2)16-14 102TIN
(2)1.0-2.0
TIN
TIN
5.0
2
12084590
PLAIN
PLAIN
PLAIN
SERIES
SERIES
SERIES
TATION
TATION
TATION
AWG
MM
AWG
MM
AWG
MM 2
PACKARD
PLATED
PLATED
Q.C.
SELECTION
GUIDE
BRASS
BRASS
BRASS
TANG
02965470 PLATED
16-14
1.0-2.0(REF)
B (REF)
12
3.0
(REF)
BRASS 12052224
BRASS
BRASS
58 SERIES
WIRE
02965469 02965580
06288318
20-18 3.0
.5-.8 3.0
02965580
1202965580
12
12
3.0
PART
NO12015870
16-14
1.0-2.0
RANGE
PACKARD
12010601
12010601
120106015.0(2)1.0-2.0
02965471
(2)16-14
(2)16-14
(2)16-14
(2)1.0-2.0
02965471
02965471
COMPANY
ORIEN10(2)1.0-2.0
12084590
Q.C. 12020035
SELECTION
GUIDE
(2)22-18
(2).5-.8
A
METRI-PACK
TIN
PACKARD
PACKARD
PACKARD
2
SERIES
TATION
TANG
B1.0-2.0
B
02965470 PLAIN
02965470
16-14
02965470
16-14 MM
16-14
AWG
PLATED
12 1.0-2.0
3.0 B1.0-2.0
SERIES58
58630
SERIES
SERIES BRASS
58 12052224
SERIES
WIRE
12015869
20-18
.5-.8
12015832
(REF)
BRASS
PART
NO20-18
02965469
06288318
02965469
06288318
02965469 .5-.8
20-18
06288318
.5-.8
20-18
.5-.8
RANGE
12015870
16-14
1.0-2.0
12 5.0
PACKARD
COMPANY 02965580
20-22
.35-.5
10
10 3.0
5.0
10ORIEN5.0
12084590 12052222
12084590
12084590
TIN
TANG SYMBOL
=
SHOWS ORIENTATION OF TANG IN SLOT
PLAIN
SERIES 02965471
METRI-PACK
12020035
(2)22-18
(2).5-.82 12TATIONA 3.0
12010601
(2)16-14
TANG
TANG
TANG
AWG
12052224
12052224
12052224
12
3.0
12(2)1.0-2.0MM 3.0
PLATED
16-12
1.3-3
BRASS
630 SERIES PACKARD
(REF)
SYMBOL
B
02965470
16-14
1.0-2.0
BRASS
60253-2
60253-1
12015832
12015869
20-18
.5-.8
58
SERIES
12015870
12015870
12015870
16-14
1.0-2.0
16-14
1.0-2.0
16-14
1.0-2.0
AMP
PACKARD
PACKARD 02965469
PACKARD
(2)
16
(2)
1.3
20-18 12
.5-.8 3.0
02965580 06288318
250 SERIES
(2)22-18
(2)22-18
A(2).5-.8B
A
12020035
12020035
12020035
METRI-PACK
METRI-PACK
METRI-PACK
12052222(2)22-18
20-22(2).5-.8
.35-.5A(2).5-.8
TANG SYMBOL =
SHOWS ORIENTATION OF TANG IN SLOT
12010601
(2)1.0-2.0 .8-2
02965471
10 (2)16-14
5.0
12084590
630 SERIES
630
SERIES
630
SERIES
42100-2
18-14
FASTIN-FASTON
42100-1
12015869
12015869
12015869
20-18
.5-.8
20-18
.5-.8
20-18
.5-.8 TANG
12015832
12015832
12015832
PACKARD
16-12
1.3-3
12 16-14
3.0
B
02965470 12052224
1.0-2.0
SYMBOL
58
SERIES
60253-1
60253-2
20-22
.35-.5
20-22
.35-.5
20-22
.35-.5
12052222
12052222
12052222
60295-2
22-18
.3-.9
60295-1
AMP
TANG
SYMBOL
=
TANG
SYMBOL
=
TANG
SYMBOL
=
SHOWS
ORIENTATION
SHOWS
OFORIENTATION
TANG
IN
SHOWS
SLOT
OFORIENTATION
TANG IN SLOT
OF TANG IN SLOT
12015870
16-14
1.0-2.0
02965469
06288318 (2) 16
20-18
(2) .5-.8
1.3
PACKARD
250 SERIESMETRI-PACK
16-12 (2)22-18
1.3-3
16-12(2).5-.8 1.3-3
16-12
B 1.3-3
A
12020035
SYMBOL
SYMBOL
SYMBOL
10
5.0 and availability.
12084590
60253-2
60253-2
60253-2
60253-1
60253-1
60253-1
AMPConsult
AMP
AMP
FASTIN-FASTON
42100-1
18-14
.8-2
42100-2
NOTE:
Delphi
Packard
and/or
Amp
on
actual
part
numbers
630 SERIES
(2)
16
(2)
1.3
(2)
16
(2)
1.3
(2)
16
(2)
1.3
TANG
12015869
20-18 12
3.0 B
250 SERIES
SERIES 12015832
250 SERIES
B
B
AMP is 250
a registered
trademark
of12052224
AMP Inc.
Harrisburg,.5-.8
PA
60295-1 FASTIN-FASTON
60295-2
22-18
.3-.9
18-14
.8-218-14
.8-2
42100-2
42100-2
42100-2
FASTIN-FASTON FASTIN-FASTON
42100-1
42100-1
42100-1
20-2216-14
.35-.5
12052222
12015870
1.0-2.0.8-218-14
Delphi Packard
Warren,
Ohio SHOWS ORIENTATION OF TANG IN SLOT
TANG
SYMBOL =
PACKARDis a registered trademark of Delphi-Packard Electrical Systems
22-18
.3-.9
22-18
22-18 A
.3-.9
60295-2
60295-2
60295-2
60295-1
60295-1 12020035
60295-1
16-12
1.3-3(2).5-.8.3-.9
(2)22-18
METRI-PACK
SYMBOL
60253-1 Amp60253-2
NOTE: Consult Delphi
on actual part numbers and availability.
AMP
630Packard
SERIES and/or
12015869 (2) 1620-18 (2) 1.3 .5-.8
12015832
.820[20.83]
250
SERIES
NOTE:
Consult
NOTE:
Packard
Consult
and/or
Delphi
NOTE:
Amp
Packard
Consult
onAMP
actual
and/or
Delphi
partAmp
numbers
Packard
on actual
and/or
and part
availability.
numbers
on actual
and part
availability.
numbers
and
availability.
AMP
is aDelphi
registered
trademark
of
Inc.
Harrisburg,
PAAmp
B
18-14
.8-2
FASTIN-FASTON
42100-1
20-22of AMP
.35-.5
12052222
AMP isPackard
a registered
AMP
trademark
is a registered
of AMP
AMP
trademark
Inc.
is42100-2
Harrisburg,
a registered
of AMP
PA
trademark
Inc.
Harrisburg,
PAInc.
Harrisburg,
PA Warren, TANG
Delphi
is.820[20.83]
a registered
trademark
of
Delphi-Packard
Electrical
Systems
Ohio SYMBOL =
SHOWS ORIENTATION OF TANG IN SLOT
Delphi Packard is Delphi
a registered
Packard
trademark
is Delphi
a registered
of
Packard
Delphi-Packard
trademark
is a registered
of
Electrical
Delphi-Packard
trademark
Systems
of
Electrical
Warren,
Delphi-Packard
Systems
Ohio
Electrical
Warren, Ohio
Systems Warren, Ohio
22-18
.3-.91.3-3
60295-2
60295-1
16-12
SYMBOL
60253-2
60253-1
AMP
(2) 16 and availability.
(2) 1.3
NOTE: Consult
Delphi Packard and/or Amp on actual part numbers
250 SERIES
.820[20.83] .820[20.83]
B .820[20.83]
.820[20.83]
.820[20.83]
.820[20.83]
.820[20.83]
AMP is a registered
trademark
Inc. Harrisburg,
PA
18-14
.8-2
42100-2
FASTIN-FASTON
42100-1 of AMP
Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Warren, Ohio
22-18
.3-.9
60295-2
60295-1
.820[20.83]
.770[19.56]
.820[20.83]
NOTE: Consult.820[20.83]
Delphi Packard and/or Amp on actual part numbers and availability.
AMP is a registered trademark of AMP Inc. Harrisburg, PA
Delphi Packard is a registered trademark of Delphi-Packard Electrical Systems Warren, Ohio
.920[23.37]
A
.920[23.37]
A
.920[23.37]
A
PACKARD 630
PACKARD 630
A B
.820[20.83]
VC1
B
VC1
PACKARD 630
A
.920[23.37]
B
A
AMP,
58 AMP, PACKARD 58
AMP, PACKARD
58
PACKARD
630 PACKARD
PACKARD 630
VC1
VC1
B
B
.920[23.37]
.920[23.37]
A
A
PACKARD
630
PACKARDPACKARD
630
630
VC1
VC1
VC1
PACKARD 630
VC1
VC1
B
B
A
A
AMP,
58
AMP, PACKARD
AMP, PACKARD
58 630
58 PACKARD
AMP, PACKARD
58
PACKARD
B
.920[23.37]
A
PACKARD 630
VC2
B
A
VC1
B
.820[20.83]
.920[23.37]
.920[23.37]
VC2
AMPAMP, PACKARD 58
PACKARD 630
AMP, PACKARD 58
VC2
A
VC2
AMP,1.266[32.16]
PACKARD 58
1.266[32.16]
1.466[37.24]
10 3A 1.266[32.16]
2 1 8
7 41.466[37.24]
5 1.466[37.24]
69
A
1.266[32.16]
AMP, PACKARD 58
10 3
2 1 8
7 4
5
69
AMP
5
AMP
679
A
VC2
B AMP PACKARD 630
58
VC2
AMP, PACKARD
4
73 45
2
A
VC2
PACKARD 630
69
15 8 6
9
A
1.170[29.72]
.770[19.56]
PACKARD 630
.950[24.13]
A
B
.770[19.56]
B
PACKARD 630
2 VC21 8
7 4
5
69
B
58AMP, PACKARD
.950[24.13]
1 87 4 5
3 4 235 1 62 8
B
AMP
AMP
AMP,
PACKARD 58
AMP,
PACKARD 58
1.250[31.75]
1.250[31.75]
1.266[32.16]
1.466[37.24]
1.266[32.16]
1.466[37.24]
1.466[37.24]
10 3 2 11.266[32.16]
81.266[32.16]
7 4 5 6 9 1.466[37.24] 1.466[37.24]
AMP, PACKARD
A4
3 A2
1 8
7 58
5 6
10 3
A
A
.950[24.13]
.950[24.13]
PACKARD 630
A
AMP, 58
PACKARD
AMP,
AMP,
PACKARD
PACKARD
58
B
A
.950[24.13]
PACKARDBA630
B
AMP, PACKARD 58
1.170[29.72]
1.170[29.72]
1.170[29.72]
PACKARD 630
A
PACKARD
PACKARD
630 630
.950[24.13]
3 2 1.170[29.72]
1 8
7
B
AMP
.770[19.56]
1.170[29.72]
A
AMPAMP
AMP
1.170[29.72]
VC2
VC2
10 10
3 23 1 28 10
84 1053 6729 417VC1
845VC1
56 96 9 10 73 4 2 51 689 10 10
3 32.920[23.37]
128 1
7104 8
3 5 2 619 8VC27 4
1 38 2 1 7.920[23.37]
B B
AMP, PACKARD 58
.770[19.56]
.770[19.56]
.920[23.37]
.920[23.37]
.920[23.37]
VC2
AMP
AMP
VC2
.770[19.56]
58
7
1.250[31.75]B
AMP, PACKARD 58
MARKING
10 3DETAIL
2 1
FRONT
VIEW
FRONT VIEW
VC1
VC1
AMP, PACKARD 58
8
AMP
MARKING
7 4DETAIL
5 69
REAR
VIEW
REAR VIEW
VC1
MARKING
10 3 DETAIL
2 1FRONT
8
VC2 FRONT VIEW VC2
VIEW
AMP
MARKING
7 4 DETAIL
5 69
REAR VIEW
VC2
PACKARD 630
AMP, PACKARD 58
MARKING
DETAIL
REAR
VIEW
3 2
1 8
FRONT
VCHVIEW
AMP, PACKARD 58
MARKING
DETAIL VIEW
FRONT
4
5 6
REAR7 VIEW
VCH
VCH
MARKING DETAIL
MARKING HOUSING
DETAIL
MARKING
DETAIL
MARKINGCONNECTOR
DETAIL
MARKING
DETAIL HOUSING
CONNECTOR
HOUSING
CONNECTOR HOUSING
1.250[31.75]
1.266[32.16]
1.466[37.24]CONNECTOR HOUSING
1.266[32.16]
1.466[37.24]
CONNECTOR
HOUSING
CONNECTOR
HOUSING
CONNECTOR
HOUSING
CONNECTOR
HOUSING
CONNECTOR
VCH
VC2
FRONT VIEW
REAR VIEW
FRONT
FRONT VIEW
(For AMP terminals
only)
(For
AMP terminals only) REAR VIEW
(For
AMP VIEW
terminals
only)
VC1 VC1
VC2
VCH
CONNECTOR HOUSING
CONNECTOR
HOUSING
MARKING
DETAIL
CONNECTOR
(For AMP terminals
only)
FRONT VIEW
MARKING DETAIL
REAR VIEW
DETAIL
HOUSINGMARKING
REAR VIEW
(ForVC2
AMP terminals only)
CONNECTOR
VC2 HOUSING
CONNECTOR
HOUSING
(For
AMP terminals
only)
Contura X Boot (P/N VB1-01)
CONNECTOR HOUSING
FRONT VIEW
6
AMP, PACKARD 58
7
4
5
6
7 4
5 6
MARKING DETAIL
REAR VIEW
MARKING
DETAIL
REAR VIEW
MARKING DETAIL
REAR VIEW
MARKING DETAIL
CONNECTOR
REAR VIEW HOUSING
VCH
CONNECTOR HOUSING
Additional V-Series Ratings
VCH
CONNECTOR HOUSING
1
.4VA @ 28VDC Resistive
4
10A 250VAC 1/2 HP, 15A 125 VAC 1/2 HP, No Agency Listings
1.050[26.67]
1.050[26.67]
1.050[26.67]
1.050[26.67]
10A 250VAC 1/2 HP, 15A 125 VAC 1/2 HP, UL Recognized, CSA Certified
51
15A 125VAC 1/2 HP, 12(2)A 125 VAC μ T85
62 VB1-01
VB1-01
2 VB1-01
15A
125VAC
1/2 XHP,
12(6)A 125 VAC T85
7VB1-01
2.000[50.80]
2.000[50.80]
2.000[50.80]
CONTURA
X BOOT
CONTURA
X
BOOT
CONTURA
BOOT
1.050[26.67]
1.050[26.67]
2.000[50.80]
CONTURA
X
BOOT
2
10A
250VAC,
15A 125VAC, 1/2 HP 125-250VAC, 12(2)A 250 VAC μ T85
8
1.050[26.67]
10A 250VAC, 15A 125VAC, 1/2 HP 125-250VAC, 12(6)A 250 VAC T85
92 VB1-01
B CONTURA X BOOT
15A 24V VB1-01
2.000[50.80]
.757[19.23]
.757[19.23]
.757[19.23]
.757[19.23]
CONTURA X BOOT
2.000[50.80]
C
20A
18V
VB1-01
2.000[50.80]
CONTURA
X BOOT
D
20A 12V
E
20A 14V, 10A 14VT (circuits 1, 4, A, & D only)
.757[19.23]
F
10A 14V, 6A, 14VT (circuit G only)
G
20A 6V
V Actuator Removal
Tool
.757[19.23]
H
20A 3V
3.99 [101.35]
.757[19.23]
3.99 [101.35]
3.99 [101.35]
3.99 [101.35]
L
15A 125 VAC, 10A 250VAC, 1/2 HP 125-250 VAC; 6A 125 VAC L
VRT
MVRT
REMOVAL
.4VA/20A
12V VRT
(combi-contact)
VRT
ACTUATOR
TOOL
.900 [22.86]
ACTUATOR
REMOVAL
ACTUATOR
REMOVAL
ACTUATOR
REMOVAL contacts for borderline dry circuit applications)
3.99 [101.35]
TOOL
(combination
gold/silver
(For
flush
bracket)
.900 [22.86]
.900 [22.86]
.900
[22.86]
TOOL
TOOL
(For flush
(For .4VA/15A
flush bracket)
(For
flush
bracket)
N bracket)
24V
(combi-contact)
VRT
REMOVAL
ACTUATOR
TOOL (combination gold/silver contacts for borderline dry circuit applications)
.900 [22.86]
TOP
INSERT POINTS UNDER
ACTUATOR
TOP
Contura II, III, IV &
(P/N VRT)
(For AMP terminals only)
CONNECTOR
HOUSING
MARKING
DETAIL
5
TOP
MARKING DETAIL
CONNECTOR HOUSING
FRONT VIEW
VC1
CONNECTOR HOUSING VC1
4
AMP, PACKARD 58
1.250[31.75]
3 2
1 8
PACKARD 630
PACKARD 630
VC1
VC1
VC2
1.250[31.75]
1.266[32.16]
1.466[37.24]
1.466[37.24]
MARKING DETAIL1.266[32.16]
MARKING
MARKING
DETAIL
DETAIL
MARKING DETAIL
MARKING
MARKING
DETAIL
DETAIL MARKING DETAIL MARKING
DETAIL MARKING DETAIL
MARKING
MARKING
DETAIL
DETAIL
MARKING
DETAIL MARKING
MARKING
DETAIL
DETAIL MARKING DETAIL
.950[24.13]
BMARKING DETAIL
B
FRONT
VIEW DETAIL
FRONT VIEW REAR1.466[37.24]
FRONT
VIEW
VIEW REAR
VIEW
FRONT
REARVIEW
VIEW
FRONT
VIEW DETAIL
FRONT
REAR VIEW
VIEW
REAR VIEWMARKING
FRONT
REAR
VIEW
VIEW
FRONT VIEW
REAR
FRONT
VIEW
VIEW
REAR VIEW
B DETAIL
B
1.266[32.16]
1.266[32.16]
1.466[37.24]
1.250[31.75]
MARKING
MARKING
DETAIL
MARKING
MARKING
DETAIL
PACKARD 630
B
PACKARD
630
B
AMP, PACKARD 58
6
PACKARD 630
PACKARD 630
TOP
INSERT POINTS
UNDER
INSERTAND
POINTS
INSERT POINTS UNDER
HOLD
FLUSH ON BRACKET
PUSHUNDER
ACTUATOR IN
ACTUATOR
ACTUATOR
HOLD FLUSH ON BRACKET ANDHOLD
PUSH FLUSH ON BRACKET AND HOLD
PUSH FLUSH ON BRACKET AND PUSH
IN
INTOP
IN
TOP
TOP
TOP
INSERT POINTS UNDER
ACTUATOR
HOLD FLUSH ON BRACKET AND PUSH
IN
TOP
TOP
(For flush bracket)
3.99 [101.35]
3.99 [101.35]
NOTES
Consult factory to determine availability for individual circuits and their HP rating.
VRT
VRT
1.
Not avaiable
with Contura
7 or 14 rocker styles.
ACTUATOR
REMOVAL
INSERT POINTS UNDER
ACTUATOR
INSERT POINTS
UNDER
2.
Ratings
6 - 9 REMOVAL
are UL,
CSA & VDE certified, require terminations A or B for double
.900
[22.86]
ACTUATOR
TOOL
ACTUATOR
TOOL
HOLD FLUSH ON BRACKET AND PUSH.900 [22.86]
HOLD FLUSH
INON BRACKET AND PUSH
(For
flush
bracket)
pole(For
circuits,
are not available with illumination circuits 4, 8, D, J, N, & T or with
IN
flush &
bracket)
TOP
TOP
wire lead or solder lug terminations.
Circuits 1, 4, A, D, H, M & E are not available with rating 6 & 8. Rating 7 & 9 only available
with circuits 1, 4, A & D. Circuits 2, 3, 5, 7, 8, K, L are 1/2 HP 250VAC only with rating 8.
Ratings 6 & 7 must specify lamp code 1 (125VAC neon). Ratings 8 & 9 must specify lamp
code 2 (250VAC neon). Rating L available with circuits 1, 4, A & D only.
TOP
TOP
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
V-Series Contura Sealed Rocker Switch Accessories | 11
Contura Mounting Panels
Dimensional Specifications: in. [mm]
Contura Hole Plug
Dimensional Specifications: in. [mm]
1.450 [36.83]
.830 [21.08]
TEST CUT
HOLE IN
ACTUAL
MATERIAL
VHP
CONTURA II,III HOLE PLUG
1.240 [31.50]
1.820 [46.23]
.430 [10.92]
VHP
CONTURA II,III HOLE PLUG
VH1
STANDARD HOLE PLUG
(No wing serrations)
(With VC1 connector attached)
2.000 [50.80]
VH2
STANDARD HOLE PLUG
(With wing serrations)
1.067 [27.10]
1.928 [48.97]
VH3
CONTURA IV HOLE PLUG
(No wing serrations)
VH4
CONTURA IV HOLE PLUG
(With wing serrations)
DETAIL VIEW
VH1,VH3 & VH5
HOLE PLUGS
(No wing serrations
for ease of removal)
1.020 [25.91]
VH5
CONTURA V HOLE PLUG
(No wing serrations)
VH6
CONTURA V HOLE PLUG
(With wing serrations)
DETAIL VIEW
VH2,VH4 & VH6
HOLE PLUGS
(With wing serrations)
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
12 | Reps & Contact
Authorized North America Sales Representatives
Carling extensive sales representative network group is strategically located and ready to answer any
questions. Find your local representative by clicking on a group name on the map below or by visiting
www.carlingtech.com/findarep.
«
«
Matera
W. Canada
WA
TEMCO Northwest
ND
John Ammouneh
Alaska, Hawaii
«
NORTHERN
WI
MN
SD
Sierra
WY
NE
Omega Limited
NV
UT
CA
KS
CO
AZ
Sunbelt Components
DM Mexico
«
El Paco, Mexico
VA
NH
Norris
NY MA
CT
RI
PA
Pacent
NJ
DE
MD
TSI North
TSI
NC
SC
Pinnacle Marketing
MS
AL
SOUTHEAST
GA
LA
ProRep
Solutions
FL
«
«
Matrix
South America
L D. Allen
WV
KY
MO
AR
TX
Central America
IL
ME
VT
DM Assoc
East
DM OH
Assoc
OK
NM
Patricia Ortiz
IN
TN
Luscombe
Engineering
Signal
Enterprises
IA
Dy-tronix Inc.
Melody
Emery
MI
ID
Bridge Marketing
WEST
DM
Michigan
Hanna Lind Ltd.
MT
OR
Matera
E. Canada
MIDWEST
LATIN AMERICA
About Carling
Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches
and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power
distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide,
Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical
components, they engineer powerful solutions! To learn more about Carling please visit
www.carlingtech.com/company-profile.
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
Notes | 13
* Intentionally left blank
Email: [email protected] • Application Support: [email protected]
Phone: (860) 793–9281 • Fax: (860) 793–9231• www.carlingtech.com
Worldwide Headquarters
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: [email protected] • www.carlingtech.com
East Region Sales Office, CT • [email protected]
Midwest Region Sales Office, IL • [email protected]
West Region Sales Office, CA • [email protected]
Asia-Pacific Headquarters
Carling Technologies, Asia-Pacific Ltd.,
Kowloon, Hong Kong
Int + 852-2737-2277 • Fax: Int + 852-2736-9332
Email: [email protected]
Shenzhen, China • [email protected]
Shanghai, China • [email protected]
Pune, India • [email protected]
Kaohsiung, Taiwan • [email protected]
Yokohama, Japan • [email protected]
Europe/Middle East/Africa Headquarters
Carling Technologies LTD
4 Airport Business Park, Exeter Airport,
Clyst Honiton, Exeter, Devon, EX5 2UL, UK
Int + 44 1392-364422 • Fax: Int + 44 1392-364477
Email: [email protected]
GmbH, Germany • [email protected]
SAS, France • [email protected]
REV_SW_V_10_2014