Carling Technologies, Inc.

L-Series
Switch
The L-Series rocker switch is an innovative product offering
total design flexibility, while at the same time setting new
standards for performance and reliability. Its versatile design
features include a neatly proportioned size that fits into an
industry standard mounting hole of 1.734 x .867 (44.0mm
x 22.0mm), countless unique choices for ratings, circuits,
colors, illuminations and laser etched legends. These single or
double pole switches also feature a broad choice of actuator
styles, colors, and lenses with up to twelve terminals offering
an extensive range of switch and lamp circuit options,
including LED or incandescent illumination. Additionally, an
optional plug-in terminal connector enables pre-wiring of
wire your harness.
Typical Applications:
Performance Features:
ŠŠ
IP67 certified sealed front panel components
ŠŠ
Construction machinery
ŠŠ
Withstands temperatures from -40°C to +85°C
ŠŠ
Agricultural equipment
ŠŠ
Vibration, shock, thermoshock, moisture and salt spray
ŠŠ
On-highway transportation equipment
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062-1177
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: [email protected] • www.carlingtech.com
resistant
2 | L–Series Sealed Rocker Switches
L-Series Switch
DESIGN FEATURES
ELIMINATES NEED
FOR RETOOLING
Neatly proportioned,
the L-Series fits
into an industry
standard mounting
hole of 1.734 x .867
[44.0mm x 22.0mm].
INTEGRATES EASILY
INTO YOUR SYSTEM
Available with two
industry standard
termination options,
.250 TAB or .187 TAB.
ENSURES GREATER
SHOCK PROTECTION
Welded lamp connection
and one-piece internal,
jumperless terminal
withstand extreme shock
and vibration.
WITHSTANDS EXTREME
TEMPERATURES
Roller pin mechanism eliminates need for lubricants,
Withstanding temperatures
from -40°C to +85°C.
MAXIMIZES YOUR
DESIGN FLEXIBILITY
Twelve terminals offers
an extensive range of
switch and lamp circuit
options, including LED or
incandescent illumination.
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
L–Series Sealed Rocker Switches - General Specifications | 3
Electrical
Contact Rating
.4VA @ 24VDC (MAX) resistive
15 amps, 125VAC
10 amps, 250VAC
20 amps, 4-14VDC
15 amps, 15-28VDC
Dielectric Strength
1250 Volts RMS between pole to pole
3750 Volts RMS between live parts
and accessible surfaces
Insulation Resistance
50 Megaohms
Initial Contact Resistance 10 milliohms max. @ 4VDC
Life
100,000 cycles maintained,
50,000 cycles momentary at rated
voltage and current
Contacts
90/10 silver-nickel, silver tin-oxide,
gold
Terminals
Brass or copper/silver plate
3/16” (4.76mm) & 1/4” (6.3mm) Quick
Connect terminations standard.
Mechanical
Endurance
250,000 cycles minimum
Physical
Lighted
Incandescent - rated 10,000 hours
LED - rated 100,000 hours 1/2 life
(LED is internally ballasted for
voltages to 24 VDC)
Rocker, base & bracket are sealed.
Nylon 66 GF rated to 85°C with a
flammability rating of 94V0.
Nylon 66 Reinforced, rated to 105°C
(modular lens). Locking rocker,
standard rocker & paddle. Laser
etching with a polycarbonate actuator.
Acetal
Polycarbonate rated at 100°C.
Nylon Zytel
Nylon 66 rated at 85°C. Polarized.
Seals
Base
Rocker
Lock
Lens
Bracket
Connector
Actuator Travel (Angular Displacement)
2 position
3 positions
26°
1.970
13° from center
.390 [9.91]
Environmental
Environmental
IP67 for above panel components
of the actual switch, representing
an index of protection as applied to
electrical equipment in accordance
with IEC 529, BS 5490, DIN 400 50 &
NFC 20 010.
Corrosion
Mixed Flowing Gas MFG Class III per
ASTM B-827 & B-845, Method H, with
3 years exposure.
Operating Temperature -40°C to + 85°C
Vibration 1
Per Mil-Std 202F, Method 204D Test
Condition A 0.06 DA or 10G’s 10-500
Hz. Tested with VCH connector. Test
criteria - No loss of circuit during
test and pre and post test contact
resistance.
Vibration 2
Resonance search
24-50 Hz 0.40 DA
50-2000 ±10 G’s peak
Results Horizontal Axis 3-5 G’s max.
Random
24 Hz 0.06 PSD-Gsq/Hz
60 Hz 0.50
100 Hz 0.50
200 Hz 0.025
2000 Hz0.025
No loss of circuit during test; <10µ
chatter.
Shock
Per Mil-Std 202F, Method 213B, Test
Condition K @ 30G’s. Tested with VCH
connector. Test criteria - No loss of
circuit during test, pre, and post test
contact resistance.
Salt Spray
Per Mil-Std 202F, Method 101D, Test
Condition A, 48 Hrs.
Thermal Shock Per Mil-Std 202F, Method 107F, Test
Condition A, -55°C to 85°C. Test
criteria - pre and post test contact
resistance.
Moisture Resistance
Per Mil-Std 202F, Method 106F, Test
Criteria - pre and post test contact
resistance.
Mounting Specifications
.867 [22.02]
1.734 [44.04]
.260 [6.60]
1.020 [25.91]
TEST CUT
HOLE IN
ACTUAL
MATERIAL
MOUNTING HOLE
.100 [2.54]
2.265 [57.53]
3.055 [77.60]
*Manufacturer reserves the right to change product specification without prior notice.
T1
BAT
T2
OUTPUT
(LOAD)
Panel Thickness Range
Acceptable Panel Thickness
.030 to .156 (.76mm to 3.96mm)
Recommended:
.030, .062, .093, .125 and .156
.250 X .031
[6.35 X .79]
T3
GROUND
PADDLE STYLE ACTUATOR
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
1.300 [33.02]
Q.C. SELECTION GUIDE
4 | L-Series Sealed Rocker Switches – Dimensional Specifications in. [mm]
Dimensional Specifications: in. [mm]
L-SERIES
L-SERIES
SHOWN WITH LASER ETCHED
ACTUATOR
SHOWN WITH ROCKER GUARD
1.970 [50.04]
1.020 [25.91]
.435 [10.16]
.400 [10.16]
1.450 [36.83]
.855 [21.72]
L-SERIES
L-SERIES
SHOWN WITH LARGE LENS
AND PADDLE ACTUATOR
SHOWN WITH BAR LENS, LOCK
AND CONNECTOR
1.970 [50.04]
1.020 [25.91]
.453 [11.51]
.400 [10.16]
Connector
LC1-01
LC2-01
LC3-01
12 4 3
2 1 10
12 4 3
2 1 10
Hole Plug
L-SERIES
CONNECTOR
L-SERIES
HOLE PLUG
BLACK .250 TAB CONNECTOR (PACKARD 630 SERIES)
BLACK .187 TAB CONNECTOR (PACKARD 480 SERIES)
1.970 [50.04]
BLACK .250 TAB CONNECTOR (AMP ONLY)
2.380 [60.45]
LH1
REMOVABLE HOLE PLUG
WITH NON-SERRATED WINGS
LH2 HOLE PLUG WITH
SERRATED WINGS
1.020 [25.91]
.500 [12.70]
1.325 [33.66]
.920 [23.37]
1.710 [43.43]
.790 [20.07]
.300 [7.62]
.855 [21.72]
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
L-Series Sealed Rocker Switches – Dimensional Specifications in. [mm] | 5
Dimensional Specifications: in. [mm]
+.008
-.000
+.008
-.000
.984 [25.00]
2.020 [51.31]
R .093 MAX TYP
R .093 MAX TYP
MOUNTING PANEL
TEST
CUT
HOLE IN
ACTUAL
MATERIAL
TEST
CUT
HOLE IN
ACTUAL
MATERIAL
+.008
-.000
1.900 [48.26]
LMS
MOUNTING PANEL
HOLE
FOR ADDITIONAL UNITS, ADD 1.03 [26.2] PER UNIT.
FOR MORE THAN 2 L-SERIES SWITCHES, ADD MIDDLE
SECTION. AVAILABLE IN PANEL THICKNESSES LISTED
BELOW. CONSULT FACTORY
+.008
-.000
1.900 [48.26]
DIMENSIONS: LME 2.02 [51.3mm] PLUS NUMBER OF
CENTER BEZELS (LMM) X 1.034 [26.26mm]
MOUNTING PANEL THICKNESS
.062 [1.57]
.093 [2.36]
.125 [3.17]
.156 [3.96]
MOUNTING PANEL
OPENING
(2) UNITS
2.300 [58.42]
2.300 [58.42]
1.187 [30.15]
1.030 [26.16]
LME MOUNTING PANEL
END
1.990 [50.55]
2.300 [58.42]
1.340 [34.04]
LMM MOUNTING PANEL
MIDDLE
LMS
MOUNTING PANEL
1.700 [43.18]
1.030 [26.16]
1.030 [26.16]
.670 [17.02]
2.300 [58.42]
2.300 [58.42]
3.400 [86.36]
4.430 [112.52]
LM3 MOUNTING PANEL
PANEL OPENING SIZE: 1.90 X 3.06 [48.3mm X 77.7mm]
LM4 MOUNTING PANEL
PANEL OPENING SIZE: 1.90 X 4.09 [48.3mm X 103.9mm]
1.030 [26.16]
.670 [17.02]
2.300 [58.42]
6.490 [164.85]
LM6 MOUNTING PANEL
PANEL OPENING SIZE: 1.90 X 6.15 [48.3mm X 156.2mm]
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
6 | L-Series Switch – Circuit Diagrams
CIRCUIT
CODE
CIRCUIT
CODE
SCHEMATIC
CIRCUIT
CODE
SCHEMATIC
5
4
4
11
22
6
2
4
2
23
2
6
2
1
4
2
1
14
2
6
4
54
2
2
1
4
6
4
8
5
26
15
2
4
1
1
17
2
6
4
6
2
1
18
4
2
1
3
31
2
6
2
21
6
4
3
4
58
2
8
1
8
5
30
4
3
57
2
4
4
8
5
28
1
4
3
8
5
2
4
3
56
2
1
4
1
2
6
4
27
16
2
55
2
1
4
3
8
5
25
1
3
53
2
4
4
1
8
5
24
1
4
3
52
2
13
3
5
4
4
1
51
2
12
SCHEMATIC
4
5
7
2
8
1
3
5
7
2
4
6
8
61
2
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
L-Series Switch – Circuit Diagrams | 7
CIRCUIT
CODE
CIRCUIT
CODE
SCHEMATIC
3
SCHEMATIC
7
1
62
4
5
4
5
8
71
2
4
1
3
6
8
5
7
2
1
7
63
8
72
2
4
6
7
2
8
3
4
7
64
8
73
2
4
1
3
6
7
2
8
5
5
4
7
65
8
80
2
4
6
6
2
8
3
4
7
5
1
8
81
66
2
4
6
6
2
8
3
1
7
67
5
4
8
82
2
4
6
6
3
8
8
4
1
68
2
3
4
7
8
A2
INTERNAL
CONNECTION
7
2
6
8
4
1
69
1
4
7
8
A3
INTERNAL
CONNECTION
7
2
1
4
2
5
6
8
70
2
7
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
8 | L-Series Lamp – Circuit Diagrams
ILLUMIN.
CODE
SCHEMATIC
ILLUMIN.
CODE
-9
-9
A
A
1
ILLUMIN.
CODE
SCHEMATIC
SCHEMATIC
ILLUMIN.
CODE
-9
J
1
1
B
B
C
+10
+12
-9
+4
D
1
-9
+4
E
1
F
1
1
2
2
1
1
-12
INTERNAL
CONNECTION
INTERNAL
CONNECTION
2
2
-12
K
K
(+)10
+4
INTERNAL
CONNECTION
INTERNAL
CONNECTION
1
+10
+10
(–)9
(–)9
1
1
(+)10
SYMBOL
+8
1
2
-9
SYMBOL
DEFINITION
TERMINAL LOCATION
MAINTAINED CIRCUIT
MAINTAINED CIRCUIT
2
MOMENTARY CIRCUIT
MOMENTARY CIRCUIT
INTERNAL CONNECTION
(JUMPER TERMINAL)
+4
2 POSITION CONNECTION
G
1
2
2
P3
P1
P3
+10
-9
-9
H
1
+10
P3
H
1
2
2
P2
P1
P3
INTERNAL CONNECTION
(JUMPER TERMINAL)
2 POSITION CONNECTION
P1
2 POSITION
2 POSITION
+10
DEFINITION
TERMINAL LOCATION
LAMP LOCATION
LAMP LOCATION
+10
+4
LEGEND
LEGEND
2
-9
2
+10
+10
+12
+4
1
2
+8
+10
G
2
+10
-9
-9
1
2
-12
1
+10
F
+4
-12
+12
1
2
+10
E
2
+12
-9
1
-9
1
2
-9
D
J
-11
-11
-9
+4
+1
+10
+10
C
+1
SCHEMATIC
-9
P2
P1
3 POSITION
+10
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
3 POSITION
L-Series Sealed Rocker Switches – Ordering Scheme | 9
L 11 E 3 C H N 1 — 3 A A 45 — 1 48
2
Circuit
3
Rating
4
5
6
Termination Illumination Lamp
7
Lamp
8
Bracket
1 SERIES
L
Terminal Orientation
( ) - momentary
SP - single pole - uses terminals 1, 2 & 4.
DP - double pole uses terminals 5, 6 & 8.
Terminals 9, 10 & 11 for lamp circuit only.
1
SPDP
2 & 3, 6 & 8
1121
ON
1222
(ON)
1323
ON
1424
ON
1525
ON
1626
ON
1727
ON
1828
(ON)
CIRCUITS WITH JUMPER TERMINALS
30*
(2,4 & 5), (1,6&8)
31
1, 2 & 5
PROGRESSIVE CIRCUITS
51
3&4
52
3&4
53
(3 & 4)
54
(3 & 4)
55
(3 & 4)
56
(3 & 4)
57
3&4
58*
2&4
61
3 & 4, 7 & 8
62
3 & 4, 7 & 8
63
(3 & 4) , ( 7 & 8)
64
(3 & 4) , ( 7 & 8)
65
(3 & 4) , ( 7 & 8)
66
(3 & 4) , ( 7 & 8)
67
3 & 4, 7 & 8
68
2 & 4, 7 & 8
69*
2 & 4, 1, 7 & 8
70
(2 & 4) , ( 7 & 8)
71
(2 & 4) , ( 7 & 8)
72
2 & 4, 7 & 8
73
(2 & 4) , ( 7 & 8)
80
2 & 4, 6 & 8
HAZARD WARNING CIRCUITS
A2
6,7&8,3&4
A3
6,7&8,2&4
* Available with ratings 1, 4, & E only.
2
3
OFF, OFF
2, 3 & 7
(1,2 & 8), (4,5&6)
2, 4 & 8
2&3
2&3
2&3
2&3
2&3
2&3
2&3
2&3
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 4, OFF
2 & 4, OFF
2 & 4, 5 & 7
2 & 4, 5 & 7
2 & 4, 5 & 7
2 & 4, OFF
2 & 4, OFF
1&2
OFF
1&2
OFF
(1 & 2)
(OFF)
(OFF)
1&2
1 & 2, 5 & 6
OFF, OFF
1 & 2, 5 & 6
OFF, OFF
(1 & 2), (5 & 6)
(OFF, OFF)
(OFF, OFF)
OFF, OFF
OFF, OFF
(1 & 2), (5 & 7)
1 & 2, 5 & 7
1 & 2, 5 & 7
OFF, OFF
OFF, 5 & 6
NONE
NONE
OFF, 1 & 2
OFF, 1 & 2
Connected Terminals
NONE
NONE
NONE
NONE
NONE
OFF
OFF
OFF
1 & 2, 5 & 6
OFF
OFF
(OFF)
ON
(ON)
ON
(ON)
(ON)
3 RATING2
1
4
B
C
D
E
G
H
.4VA @ 28VDC Resistive
10A 250VAC 1/2 HP, 15A 125VAC 1/2 HP, No Listings
15A 24V
20A 18V
20A 12V
15A 12V
20A 6V
20A 3V
4 TERMINATION2,3,4
1
3
10
11
12
Lens Style Lens Style Legend
& Color
& Color
13
14
Legend
Actuator
Orientation Lens Legend
5 ILLUMINATION
2 CIRCUIT2
Position:
9
Actuator
.250 (6.4mm) TAB (QC)
.187 (4.7mm) TAB (QC)
6,7 LAMP (SAME CODING FOR BOTH SELECTIONS)
Selection 6: above terminals 10 & 9; Selection 7: above terminals 12 & 11
0
No lamp
7 18V
4 3V
5 6V
6 12V
Incandescent
Red
Amber
Green
LED*
A
L
F
2VDC
B
M
G
6VDC
C
N
H
12VDC
D
P
J
24VDC
* Consult factory for “daylight bright”, blue/green and white LED options.
Typical current draw for LED is 20ma.
8 BRACKET COLOR1
Black
1
A
E
Standard Bracket
Rockerguard at Lamp 1
Rockerguard at Lamp 2
White
2
B
F
9 ACTUATOR STYLE AND COLOR1
Black
A
J
Rocker
Paddle
White
B
N
Gray
C
K
Gray
3
C
G
Red
4
D
H
Red
D
M
Laser Etched
3
4
8 24V
10 & 11 LENS STYLE AND COLOR
Lens color for LEDs must be clear, white, or match color of LED.
0 - No Actuator Z - No Lens
Clear
White
Amber
Green
Red
Blue
1
B
G
M
T Large Transparent
7
C
H
N
U Large Translucent
3
D
J
P
V Bar Transparent
9
E
K
R
W Bar Translucent
5
A
­- Laser Etch background color
12 LASER ETCH, LENS OR BODY LEGEND
00
No legend this location / no actuator
For legend options & codes, see pages 54-65 of the Carling Transportation catalog.
13 LEGEND ORIENTATION
0
1
2
3
4
No legend (used with codes 11-18 in selection 12)
Orientation 1 - vertical, lamp 1 on top
Orientation 2 - horizontal, lamp 1 on right
Orientation 3 - vertical, lamp 1 on bottom
Orientation 4 - vertical, lamp 1 on left
Orientation
1
Orientation
2
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 Circuits 30, 31, 58, 69 are not available with rating codes 4, C, D, G or H.
3 Termination 3 only available with rating codes 1, B, and E.
4 Termination 1 not available with rating code 4.
5 Not available with circuits 11-18, 51-57 and 69.
Lamp #1:above terminals 9 & 10 end of switch.; Lamp #2 above terminals 11 & 12 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only.
Lamps
Illumination Type
Lamp wired to Terminals
NONE
S
#1
Independent
10+ 9A
B
#2
Independent
12+ 11C
#1
Independent
10+ 9&#2
Independent
12+ 9#1
Dependent
4+
9D
E
#1
Independent
10+ 9&#2
Dependent
4+
9F5
#1
Independent
10+ 9&#2
Dependent
8+
9#1
Dependent
4+
9G
&#2
Independent
10+ 9#1
Both Independent
10+ 9H
&#2
(in series)
#1
Dependent
4+
9J
&#2
Dependent
1+
91
#2
Hazard
6+
1012#1
Hazard
6+
10122
Orientation
4
1
Series
AA
46
46
3AA-146
AA
3AA-246
14 ACTUATOR LENS LEGEND
Orientation
3
00
No legend this location / no actuator
For legend options & codes, see pages 54-65 of the Carling Transportation catalog.
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
10 | L-Series Sealed Locking Rocker Switches – Ordering Scheme
L 11 D 1 S W C J — P M H 00 — 0
2
Circuit
3
Rating
4
5
6
Termination Illumination Lock
7
Lamp
8
Bracket
1 SERIES
L
W
Position:
( ) - momentary
SP - single pole - uses terminals 1, 2 & 4.
DP - double pole uses terminals 5, 6 & 8.
Terminals 9, 10 & 11 for lamp circuit only.
1
SPDP
2 & 3, 6 & 8
1121
ON
1424
ON
1626
ON
1727
ON
1828
(ON)
CIRCUITS WITH JUMPER TERMINALS
302
(2 ,4 & 5), (1,6&8)
312
1, 2 & 5
PROGRESSIVE CIRCUITS
51
3&4
52
3&4
53
(3 & 4)
54
(3 & 4)
55
(3 & 4)
56
(3 & 4)
57
3&4
58
2&4
61
3 & 4, 7 & 8
62
3 & 4, 7 & 8
63
(3 & 4) , ( 7 & 8)
64
(3 & 4) , ( 7 & 8)
65
(3 & 4) , ( 7 & 8)
66
(3 & 4) , ( 7 & 8)
67
3 & 4, 7 & 8
68
2 & 4, 7 & 8
69
2 & 4, 1, 7 & 8
70
(2 & 4) , ( 7 & 8)
71
(2 & 4) , ( 7 & 8)
72
2 & 4, 7 & 8
73
(2 & 4) , ( 7 & 8)
80
2 & 4, 6 & 8
2
Connected Terminals
NONE
NONE
OFF
OFF
OFF
3 (Lock location)
1 & 2, 5 & 6
OFF
ON
ON
(ON)
(ON)
OFF, OFF
2, 3 & 7
(1,2 & 8), (4,5&6)
2, 4 & 8
2&3
2&3
2&3
2&3
2&3
2&3
2&3
2&3
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 3, 6 & 7
2 & 4, OFF
2 & 4, OFF
2 & 4, 5 & 7
2 & 4, 5 & 7
2 & 4, 5 & 7
2 & 4, OFF
2 & 4, OFF
1&2
OFF
1&2
OFF
(1 & 2)
(OFF)
(OFF)
1&2
1 & 2, 5 & 6
OFF, OFF
1 & 2, 5 & 6
OFF, OFF
(1 & 2), (5 & 6)
(OFF, OFF)
(OFF, OFF)
OFF, OFF
OFF, OFF
(1 & 2), (5 & 7)
1 & 2, 5 & 7
1 & 2, 5 & 7
OFF, OFF
OFF, 5 & 6
3 RATING6
.4VA @ 28VDC Resistive
10A 250VAC 1/2 HP, 15A 125VAC 1/2 HP, No Listings
15A 24V
20A 18V
20A 12V
15A 12V
20A 6V
20A 3V
13
Legend
Orientation
Lock above terminals 10 & 9.
7 LAMP
Above terminals 12 & 11
No lamp
Incandescent
LED*
2VDC
6VDC
12VDC
24VDC
0
4 3V
Red
A
B
C
D
5 6V
Amber
L
M
N
P
6 12V
Green
F
G
H
J
7 18V
* Consult factory for “daylight bright”, blue/green and white LED options.
Typical current draw for LED is 20ma.
8 BRACKET COLOR1
J
Black
9 ACTUATOR STYLE AND COLOR1
Black Red
P
R
Locking Rocker
10 LENS STYLE AND COLOR
Lens color for LEDs must be clear, white, or match color of LED.
0 - No Actuator
Clear White
1
7
3
9
Z - No Lens
Amber Green
B
G
C
H
D
J
E
K
Red
M
N
P
R
Blue
T Large Transparent
U Large Translucent
V Bar Transparent
W Bar Translucent
11 LOCK FUNCTION AND COLOR
Locking Position
Down
H
J
K
L
M
Up
A
B
C
D
E
Up & Down
R
S
T
U
V
Center3
1
2
3
4
5
Lock Color
Match Actuator
Black
White
Red
Safety Orange
13 LEGEND ORIENTATION
0
1
2
3
4
5 ILLUMINATION2
Lamp #1:above terminals 9 & 10 end of switch.; Lamp #2 above terminals 11 & 12 end of
switch. Positive (+) and negative (-) symbols apply to LED lamps only.
Lamps
Illumination Type
Lamp wired to Terminals
Independent
8 24V
00
No legend this location / no actuator
For legend options & codes, see pages 54-65 of the Carling Transportation catalog.
.250 (6.4mm) TAB (QC)
.187 (4.7mm) TAB (QC)
NONE
#2
12
Legend
12 LASER ETCH, LENS OR BODY LEGEND
4 TERMINATION4,5
S
B
11
Lock
12+
11-
ORIENTATION OF
ACTUATOR/LENS IN PANEL
No legend (used with codes 11-18 in selection 12)
Orientation 1 - vertical, lamp 1 on top
Orientation 2 - horizontal, lamp 1 on right
Orientation 3 - vertical, lamp 1 on bottom
Orientation 4 - vertical, lamp 1 on left
ORIENTATION 1
LOCK
P
LOCK
PZAY2-2
LOCK
P
P
P
P
LOCK
LOCK
P
PZAY2-1
Notes:
Consult factory to verify horsepower rating for your particular circuit choice.
1 Custom colors are available. Consult factory.
2 Additional lamp circuits available. Consult factory.
3 Available only with 3 position circuits.
4 Termination 1 not available with rating 4.
5 Termination 3 only available with ratings 1, B and E.
6 Circuits 30, 31, 58 and 69, are not available with rating codes 4, C, D, G or H.
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
LOCK
ORIENTATION 3
ORIENTATION 2
Terminal Orientation
1
3
10
Lens
6 LOCK
2 CIRCUIT6
1
4
B
C
D
E
G
H
9
Actuator
ORIENTATION 4
1
Series
| 11
* Intentionally left blank
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: [email protected] • www.carlingtech.com
Worldwide Headquarters
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062-1177
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: [email protected] • www.carlingtech.com
East Region Sales Office, CT • [email protected]
Midwest Region Sales Office, IL • [email protected]
West Region Sales Office, CA • [email protected]
Asia-Pacific Headquarters
Carling Technologies, Asia-Pacific Ltd.,
Kowloon, Hong Kong
Int + 852-2737-2277 • Fax: Int + 852-2736-9332
Email: [email protected]
Shenzhen, China • [email protected]
Shanghai, China • [email protected]
Pune, India • [email protected]
Kaohsiung, Taiwan • [email protected]
Yokohama, Japan • [email protected]
Europe/Middle East/Africa Headquarters
Carling Technologies, Ltd.,
Devon, England 06062-1177
Int + 44 1392-364422 • Fax: Int + 44 1392-364477
Email: [email protected]
GmbH, Germany • [email protected]
SAS, France • [email protected]
REV_SW_L_0612