Application Guidelines for Aluminum Electrolytic Capacitors

ALUMINUM ELECTROLYTIC CAPACITORS
Application Guidelines for Aluminum Electrolytic Capacitors
1. Circuit Design
(1)
Please make sure the application and mounting conditions to which the capacitor will be exposed to are within the
conditions specified in catalog or alternate product specification (Referred to as specification here after).
(2)
Operating temperature and applied ripple current shall be within the specification.
q The capacitor shall not be used in an ambient temperature which exceeds the operating temperature specified in
the specification.
w Do not apply excessive current which exceeds the allowable ripple current.
(3)
Appropriate capacitors which comply with the life requirement of the products should be selected when designing the
circuit.
(4)
Aluminum electrolytic capacitors are polarized. Make sure that no reverse voltage or AC voltage is applied to the
capacitors. Please use bi-polar capacitors for a circuit that can possibly see reversed polarity.
Note: Even bi-polar capacitors can not be used for AC voltage application.
(5)
For a circuit that repeats rapid charging / discharging of electricity, an appropriate capacitor that is capable of enduring
such a condition must be used. Welding machines and photo flash are a few examples of products that contain such a
circuit. In addition, rapid charging / discharging may be repeated in control circuits for servomotors, In which the
circuit voltage fluctuates substantially.
For appropriate choice of capacitors for circuit that repeat rapid charging / discharging, please consult Nichicon.
If excess a rush current due to drastic charge/dis-charge was applied to conductive polymer aluminum solid
electrolytic capacitors, it may cause a short circuit or an increase in leakage current. Therefore, Please do not apply a
rush current that is larger than 10A.
( 6 ) Make sure that no excess voltage (that is, higher than the rated voltage) is applied to the capacitor.
q Please pay attention so that the peak voltage, which is DC voltage overlapped by ripple current, will not exceed the
rated voltage.
w In the case where more than 2 aluminum electrolytic capacitors are used in series, please make sure that applied
voltage will be lower than rated voltage and the voltage be will applied to each capacitor equally using a balancing
resistor in parallel with the capacitors.
Please do not use conductive polymer alminum solid electrolytic capacitors for the application listed below, since
the solidorganicpolymeraluminum electrolytic capacitor cannot reach it's maximum performance.
1) Coupling circuits
2) R-C timing circuit
3) High impedance voltage retention circuit
4) Circuits, which extremely low voltage in compared to the rated voltage is only applie
5) Circuits, which are greatly affected by leakage currents for special use such as multiple parts used in a series,
please contact us for recommendations.
( 7 ) Aluminum electrolytic capacitors must be electrically isolated as follows:
The aluminum case and the cathode foil are connected by the unstable resistance of a naturally formed oxide layer
inside the aluminum case and the electrolyte.
q (a) Case and negative terminal (except axial leaded part such as JIS configuration 02 type)
(b) Case and positive terminal
(c) Case and circuit pattern
w (a) Auxialiary terminal of can type such as JIS style symbol 693, 694 or 695 and negative and positive terminal,
including the circuit pattern.
e Case and both terminals of a bi-polarized capacitor.
CAT.8100Z-2
ALUMINUM ELECTROLYTIC CAPACITORS
( 8 ) Outer sleeve of the capacitor is not guaranteed as an electrical insulator. Do not use a standard sleeve on a capacitor
in applications that require the electrical insulation. When the application requires special insulation, please contact
our sales office for details.
( 9 ) Capacitors may fail if they are used under the following conditions:
q Environmental (climatic) conditions
(a) Being exposed to water, high temperature & high humidity atmosphere, or condensation of moisture.
(b) Being exposed to oil or an atmosphere that is filled with particles of oil.
(c) Being exposed to salty water or an atmosphere that is filled with particles of salt.
(d) In an atmosphere filled with toxic gasses (such as hydrogen sulfide, sulfurous acid, nitrous acid, chlorine,
bromine, methyl bromide, ammonia, etc.).
(e) Being exposed to direct sunlight, ozone, ultraviolet ray, or radication.
( f ) Being exposed to acidic or alkaline solutions.
w Under severe conditions where vibration and/or mechanical shock exceed the applicable ranges of the
specifications.
(10) When designing a P.C. board, please pay attention to the following:
q Have the hole spacing on the P.C. board match the lead spacing of the capacitor.
w There should not be any circuit pattern or circuit wire above the capacitor pressure relief vent.
e Unless otherwise specified, following clearance should be made above the pressure relief vent.
Case Diameter
Clearance Required
φ 6.3 to 16mm
2mm or more
φ 18 to 35mm
3mm or more
φ 40mm or more
5mm or more
r In case the vent side is placed toward P.C. board (such as end seal vented parts), make a corresponding hole on the
P.C. board to release the gas when vent is operated. The hole should be made to match the capacitor vent position.
t Screw terminal capacitors must be installed with their end seal side facing up. When you install a screw terminal
capacitor lying down, the upper side must be the pressure relief vent or a positive terminal.
(11) The main chemical solution of the electrolyte and the separator paper used in the capacitors are combustible. The
electrolyte is conductive. When it comes in contact with the P.C. board, there is a possibility of pattern corrosion or
short circuit between the circuit pattern which could result in smoking or catching fire.
Do not locate any circuit pattern beneath the capacitor end seal.
(12) Do not design a circuit board so that heat generating components are placed near an aluminum electrolytic capacitor
or reverse side of P.C. board (under the capacitor).
(13) Please refer to the pad size layout recommendations in our catalog when designing in surface mount capacitors.
(14) Electrical characteristics may vary depending on changes in temperature and frequency. Please consider this
variation when you design circuits.
(15) When you mount capacitors on the double-sided P.C. boards, do not place capacitors on circuit patterns or over on
unused holes.
(16) The torque for terminal screw or brackets screws shall be within the specified value on Nichicon's drawings.
(17) When you install more than 2 capacitors in parallel, consider the balance of current flowing through the capacitors.
EspeciaIIy, When a solid conductive poIymer aluminum electroIytic capacitor and a standard aIuminum electroIytic
capacitor are conected in parallel, special consideration must be given.
(18) If more than 2 aluminum electrolytic capacitors are used in series, make sure the applied voltage will be lower than the
rated voltage and that voltage will be applied to each capacitor equally using a balancing resistor in parallel with each
capacitor.
CAT.8100Z-2
ALUMINUM ELECTROLYTIC CAPACITORS
2. Mounting
( 1 ) Once a capacitor has been assembled in the set and power applied, Even if a capacitor is discharged, an electric
potential(restriking voltage) may exist between the terminals.
( 2 ) Electric potential between positive and negative terminal may exist as a result of returned electromotive force, so please
discharge the capacitor using a 1kΩ resistor.
( 3 ) Leakage current of the parts that have been stored for more than 2 years may increase. If leakage current has
increased, please perform a voltage treatment using 1kΩ resistor.
( 4 ) Please confirm ratings before installing capacitors on the P.C. board.
( 5 ) Please confirm polarity before installing capacitors on the P.C. board.
( 6 ) Do not drop capacitors on the floor, nor use a capacitor that was dropped.
( 7 ) Do not damage the capacitor while installing.
( 8 ) Please confirm that the lead spacing of the capacitor matches the hole spacing of the P.C. board prior to installation.
( 9 ) Snap-in can type capacitor such as JIS style symbol 692, 693, 694 and 695 type should be installed tightly to the P.C.
board (allow no gap between the P.C. board an bottom of the capacitor).
(10) Please pay attention that the clinch force is not too strong when capacitors are placed and fixed by an automatic
insertion machine.
(11) Please pay attention to that the mechanical shock to the capacitor by suction nozzle of the automatic insertion machine
or automatic mounter, or by product checker,or by centering mechanism.
(12) Hand soldering.
q Soldering condition shall be confirmed to be within the specification.
w If it is necessary that the leads must be formed due to a mismatch of the lead space to hole space on the board,
bend the lead prior to soldering without applying too much stress to the capacitor.
e If you need to remove parts which were soldered, please melt the solder enough so that stress is not applied to lead.
r Please pay attention so that solder iron does not touch any portion of capacitor body.
(13) Flow soldering (Wave solder)
q Aluminum capacitor body must not be submerged into the solder bath. Aluminum capacitors must be mounted on
the "top side" of the P.C. board and only allow the bottom side of the P.C. board to come in contact with the solder.
w Soldering condition must be confirmed to be within Nichicon specification.
Solder temperature: 260 5oC Immersing lead time:10 1 second, Thickness of P.C. board : 1.6mm.
e Please avoid having flux adhere to any portion except the terminal.
r Please avoid contact between other components and the aluminum capacitor.
(14) Reflow soldering (SMD only)
q Soldering condition must be confirmed to be within Nichicon specification.(Please refer to page19)
w When an infrared heater is used, please pay attention to the extent of heating since the absorption rate of infrared,
will vary due to difference in the color of the capacitor body, material of the sleeve and capacitor size.
CAT.8100Z-2
ALUMINUM ELECTROLYTIC CAPACITORS
(15) Soldeing flux
There are non-halogen types of flux that do not contain ionic halides, but contain many non-ionic halides. When these
non-ionic halides infiltrate the capacitor, they cause a chemical reaction that is just as harmful as the use of cleaning
agents. Use soldering flux that dose not contain non-ionic halides.
(16) Shrinkage,bulging and/or cracking could be seen on the outer sleeve of the capacitor when capacitors are kept in for
more than 2 minutes at 150 °c ambient temperature during soldering at reflow process or resin curing process. Applying
high temperature gas or heat ray to capacitor can cause the same phenomenon.
(17) Do not tilt lay down or twist the capacitor body after the capacitor are soldered to the P.C. board.
(18) Do not carry the P.C. board by grasping the soldered capacitor.
(19) Please do not allow anything to touch the capacitor after soldering. If P.C. board are stored in a stack, please make
sure P.C. board or the other components do not touch the capacitor.
The capacitors shall not be effected by any radiated heat from the soldered P.C. board or other components after
soldering.
(20) Recommended Cleaning Condition
Applicable : Any type, any ratings.
Cleaning Agents
Based Alcohole solvent cleaning agent
Isopropyl Alcohol
Based water solvent cleaning agent
Premium alcohole solvent type
Pine Alpha ST-100S
Techno Care FRW 14 to17
Sanelek B-12
Surfactant type
Clean Through 750H, 750L, 710M
Alkaline saponification agent
Aqua Cleaner 210SEP
Cleaning Conditions :
Total cleaning time shall be no greater than 5 minutes by immersion, ultrasonic or other method.
(Temperature of the cleaning agent shall be 60oC maximun.)
After the board cleaning has been completed, the capacitors should be dried using hot air for a minimumn of 10
minutes.
If the cleaning solution is infiltrated between the case and the sleeve, the sleeve might soften and swell when hot
air temperature is too high. Therefore, hot air temperature should not exceed softening temperature(80oC) of the
sleeve.
Insufficient dries after water rinse may cause appearance problems, such as sleeve shrinking, bottom-plate
bulging.
ln addition, a monitoring of the contamination of cleaning agents (electric conductivity, pH, specific gravity, water
content, etc.) must be implemented.
After the cleaning, do not keep the capacitors in an atmosphere containing the cleaning agent or in an air tight
container.
Depending on the cleaning method, the marking on a capacitor may be erased or blurred.
Consult Nichicon before using a cleaning method or a cleaning agent other than those recommended.
The use of hydro-chlorofluorocarbon (HCFC) is expected to be banned in the future and Nichicon does not recommend the
use of HCFC as a cleaning agent considering its impact on the environment. When it is absolutely necessary to use HCFC,
cleaning is possible under the following conditions:
CAT.8100Z-2
ALUMINUM ELECTROLYTIC CAPACITORS
Cleaning Agent
AK-225AES
Miniature Type
Large Can Type
Applicable
Series
Aluminum Electrolytic Capacitors
Conductive Polymer Aluminum Chip (SMD) Type
Solid Electrolytic Capacitors
Miniature Type
Cleaning
Conditions
CF, CJ, CK,
CG, CS, CV
LF, LE, LG,
LS, LV
Chip (SMD) Type
ZD, ZR, ZE, ZG, ZS, ZP, ZT, WX,
WR, WJ, WP, WT, WZ, WF, WG,
UP, UT, UA, UL, CB, CW, CD,
CL, UD, WD, UB(50V or less),
WH, CJ, CZ, UR, WS,
UX (100V or less ), UQ, UN, UH,
UE, BC,
UG (100V or less)
UJ (100V or less)
Ultra-Miniature Type
MA, MP, MT, MF, SA, SR, SP,
ST, SF
Standard Products
VK(100V or less )
VR (100V or less )
VY (100V or less )
VZ (100V or less )
RS (100V or less )
RZ (100V or less )
RU(100V or less )
RY (100V or less )
VP, EP
High-Reliability Type
PM (100V or less )
PW (100V or less )
TT,PA,HV, HD, HC, HE, HM, HN, HZ
PJ (100V or less )
PS (100V or less )
TS,PV,PX
PB (100V or less )
BT (100V or less ), BW, BX
For Special Circuit
KL, TM, JB
VX 02 type (100V or less )
For Audio Use
KZ, FG, KW, FW, MW, SW, ES,
DB, GB, KT
Standard Products
LS (100V or less )
High-Reliability Type
GU (100V or less )
GY
Within 5 minutes, total cleaning time by immersion, vapor
spray, or ultrasonic and such. For SMD and
ultra-miniature type, within 2 minutes total cleaning time.
(Temp. of agent: 40°C or below)
(21) Fixing Material and Coating Material
1) Do not use any affixing or coating materials, which contain halide substance.
2) Remove flux and any contamination, which remains in the gap between the end seal and PC board.
3) Please dry the cleaning agent on the PC board before using affixing or coating materials.
4) Please do not apply any material all around the end seal when using affixing or coating materials.
There are variations of cleaning agents, fixing and coating materials, so please contact those manufacture or our sales
office to make sure that the material would not cause any problems.
(22) Others
Wooden package material may be subjected to fumigation by a halogen(e.g. methyl bromide) before they are exported
in order to protect them against pests. If devices with aluminum electrolytic capacitors or capacitors themselves are
directly fumigated or packed with the pallet that is fumigated, the capacitors may internaIly corrode due to the halogen
contents of fumigation agents.
3. In the equipment
( 1 ) Do not directly touch terminal by hand.
( 2 ) Do not short between terminals with conductor, nor spill conductible liquid such as alkaline or acidic solution on or
near the capacitor.
( 3 ) Please make sure that the ambient conditions where the set is installed not have any of the following conditions:
CAT.8100Z-2
ALUMINUM ELECTROLYTIC CAPACITORS
q Where capacitors are exposed to water, high temperature & high humidity atmosphere, or condensation of moisture.
w Where capacitors are exposed to oil or an atmosphere that is filled with particles of oil.
e Where capacitors are exposed to salty water, high temperature & high humidity atmosphere, or condensation of
moisture.
r The atmosphere is filled with toxic acid gasses (e.g. hydrogen sulfide, sulfurous acid, nitrous acid, chlorine,
bromine, methy bromide, etc.)
t The atmosphere is filled with toxic alkaline gasses (e.g. ammonia)
y Where capacitors are exposed to acidic or alkaline solutions.
u Since shrinkage, bulging and/or crack could be seen on outer sleeve of capacitor when capacitors are used in
atmosphere where condensation of moisture occures, please confirm their adaptation before the use.
The condensation of moisture could occure when temperature cycling test /Rapid change of temperature test is
performed, in this case, aforementioned sleeve problem could be seen.
4. Maintenance Inspection
( 1 ) Please periodically inspect the aluminum capacitors that are installed in industrial equipment.
should be checked:
The following items
q Appearance : Remarkable abnormality such as vent operation, leaking electrolyte etc.
w Electrical characteristic: Capacitance, dielectric loss tangent, leakage current, and items specified in the
specification.
5. In an Emergency
( 1 ) If you see smoke due to operation of safety vent, turn off the main switch or pull out the plug from the outlet.
( 2 ) Do not bring your face near the capacitor when the pressure relief vent operates. The gasses emitted from that are
over 100oC.
If the gas gets into your eyes, please flush your eyes immediately in pure water.
If you breathe the gas, immediately wash out your mouth and throat with water.
Do not ingest electrolyte. If your skin is exposed to electrolyte, please wash it away using soap and water.
6. Storage
( 1 ) lt is recommended to keep capacitors between the ambient temperatures of 5oC to 35oC and a relative humidity of
75% or below.
( 2 ) Please make sure the ambient storage conditions will be free from the conditions that are listed in clause 3. "In the
equipment" at (3).
In order to maintain the satisfactory soldering condition for conductive polymer aluminum solid electrolytic capacitors,
the following items must be strictly adhered to.
1) Parts should be stored sealed in a bag until they are actually used.
2) Once the sealed bag is cut open, all the parts should be used at one time. If not, then the remaining parts should be
places in a bag and sealed with tape.
3) In order to maintain a good solderability of the parts, shelf life of parts should not exceed 1 year.
CAT.8100Z-2
ALUMINUM ELECTROLYTIC CAPACITORS
7. Disposal
( 1 ) Take either of the following methods in disposing of capacitors.
q Make a hole in the capacitor body or crush capacitors and incinerate them.
w If incineration is not applicable, hand them over to a waste disposal agent and have them buried in a landfilI.
( 2 ) When removing a capacitor from the circuit board or when disposing of capacitor please ensure that the capacitor is
properly discharged.
The above mentioned material according to EIAJ RCR - 2367B (issued in March, 2002), titled "Guideline of notabilia for
aluminum electrolyic capacitors for use in electronic equipment".
Please refer to the book for details.
ESR, Impedance Measuring Point
Radial lead type
ESR should be measured at both of the terminal ends closest to the capacitor body.
Chip type
ESR should be measured at both of the terminal ends closest where the terminals protrude through the plastic platform.
Type numbering system
1
Type
2
3
4
Series name
5
Rated voltage
6
7
8
9
Rated capacitance Capacitance
tolerance
10
11
Configuration
See pages
25, 51 to 53
12
13
14
Size
code
See pages
27 to 307
See pages
27 to 307
Conductive
polymer type
(CA32,04)
P
Aluminum
electrolytic capacitors
Chip type
Radial lead type
(CE32,04)
U
Aluminum
electrolytic capacitors
Axial lead type
(CE02)
T
Aluminum
electrolytic capacitors
Can type
(CE621,622,692,
694,695,331)
L
Rated
voltage
(V)
2.5
4.0
5.5
6.3
10.0
16.0
20.0
25.0
35.0
50.0
63.0
80.0
100.0
110.0
Code
0E
0G
0L
0J
1A
1C
1D
1E
1V
1H
1J
1K
2A
2Q
Rated
voltage
(V)
125
160
180
200
220
250
315
350
400
420
450
500
550
630
Capacitance
Code
2B
2C
2Z
2D
2P
2E
2F
2V
2G
W6
2W
2H
2L
2J
(µF)
0.1
0.47
1
2.2
22
220
2200
22000
Code
0R1
R47
010
2R2
220
221
222
223
Cap. tol.
(%)
±10
±20
– 10 to +30
– 10 to +50
Special
Code
K
M
Q
T
A
Miniature
Type
Taped,
lead cut / formed
See pages
20 to 22
Large Can Type
Specification
code
CAT.8100Z-2
OVERSEAS FACTORY PRODUCTION ITEMS LIST
ALUMINUM ELECTROLYTIC CAPACITORS
Type
Classification
Series
NICHICON (MALAYSIA)
SDN. BHD.
NICHICON ELECTRONICS
(WUXI) CO., LTD.
™
™
WX, WR, WJ, WT,
WZ, WF, WG, UT,
UA, UL, CD, UD,
Chip Aluminum Electrolytic Capacitors
Chip Type
WD, UB, WH, UR,
WS, UX
MA, MT, SA, SR, ST
™
™
VK, VR, VY, VZ
™
™
VP, EP
™
™
™
™
™
™
BT
™
™
KL
™
™
WP, UP
Ultra-Miniature Type
Standard Type
PM, PW, HD, HE,
PJ, PS, PB
Miniature Aluminum
High Reliability Type
Electrolytic Capacitors
HV, HC, HM, PV, PT,
PZ, CA,CS
Special Equipment
™
AQ, AS
FW
™
MW, SW
™
LS, LG
™
™
™
™
For Audio Equipment
Standard Type
Large Can Aluminum
Electrolytic Capacitors
High Reliability Type
GU, GN, GG, GJ,
GY, GX
For Audio Equipment
KG, KS, KX
™
applicable size D φ63 to 100
L 80 to 200L
Please contact us for details.
Screw Terminal Electrolytic Capacitors
However, please contact us because there may be a series, size that cannot be produced at a given factory.
SOLID TANTALUM ELECTROLYTIC CAPACITORS
Type
Chip Solid Tantalum Electrolytic
Capacitors
Classification
Series
NICHICON ELECTRONICS (TIANJIN) CO., LTD.
Chip Type
F92, F93
™
CAT.8100Z-2