PEG 126 150°c

PEG 126
RoHS
150°C
Compliant
• 150°C
• Resistance to vibrations
• Low ESR
•High ripple capability
application
Basic design
PEG 126 is a high performance axial
electrolytic capacitor. It is designed for
automotive applications with high demands
on resistance to vibrations and high ambient
temperature.
PEG126 is an electrolytic capacitor with
outstanding electrical performance.
Polarized, all-welded design, tinned copper
wire leads, negative pole connected to the
case, plastic insulation. The PEG 126 winding
is housed in a cylindrical aluminium can with
a high purity aluminium lid and a high quality
rubber gasket. Low ESR is a result of a low
resistive electrolyte/paper system and an
all-welded design. Thanks to its mechanical
robustness the PEG 126 is suitable for use
in mobile and aircraft installations, operation
up to 150°C.
Specification
IEC 60384-4 Long Life
Grade 40/125/56
250-4000µF
–10 to +30%
25-63 VDC
–40 to +150°C
8500 h at 125°C (Case Ø = 20 mm)
6500 h at 125°C (Case Ø = 16 mm)
5000 h at 0V+105°C, or
10 years at 0V +40°C
16 – 20 mm
10-2000 Hz, 1.5 mm
displacement amplitude or
max 20 g 3x2 hours
The capacitors shall be clamped
by their body.
2000 h, 150°C (Case Ø = 20 mm)
1500 h, 150°C (Case Ø = 16 mm)
Ø1.0±0.03
30
16 x 37 20 x 29 20 x 37 20 x 46 F G H J L 16 16 20
20 20 Radial version
See page 39
�0.8±0.1
15.24±0.1
dLL1
b+3/-2Weight
± 0.03±1
minBox
approx (g)
1.0 1.0 1.0 1.0 1.0 29.0
37.0
29.0
37.0
46.0
±0
.5
35.0
43.0
35.0
43.0
52.0
42 42 42 42 42 8
11
13
20
24
© KEMET 2006. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without KEMET's prior express consent is prohibited.
3.3±0.5
CaseD
code
±0.5
.5
Ø16.5±0.5
Dimensions table PEG 126 (mm)
D x L
16 x 29 17
H
Standards Capacitance range Capacitance tolerance Rated voltage Temperature range Operational life time
Shelf life at
Diameter range Resistance to vibrations Life test
PEG 126
Article table PEG 126 (150°C)
CR D x L IRAC *IRAC*
IRAC*IRAC*ESR* ESR* LESLArticle
125°C
105°C
125°C
150°C
20°C
20°CApprox
code
100 Hz
≥5 kHz
≥5kHz
≥5kHz
100Hz
100kHz
µF mm A
AAA
mΩ
mΩ nH
25 VDC (UR )
680
1000
1500
2200
3300
4000
16 x 29
16 x 37
16 x 37
20 x 29
20 x 37
20 x 46
1.4
1.7
2.1
2.5
3.2
3.7
6.9
8.8
9.2
9.4
11.7
13.1
4.1
5.2
5.4
5.5
6.9
7.7
1.6
2.0
2.1
2.1
2.6
2.9
120
80
63
51
34
29
43
28
26
25
17
14
10
12
12
12
15
17
PEG126HF368EQ
PEG126HG410EQ
PEG126HG415EQ
PEG126HH422EQ
PEG126HJ433EQ
PEG126HL440EM
150
120
75
71
58
43
37
45
30
23
26
22
18
17
10
12
12
12
12
15
17
PEG126KF347EQ
PEG126KG360EQ
PEG126KH410EQ
PEG126KH412EQ
PEG126KH415EQ
PEG126KJ422EQ
PEG126KL427EQ
240
160
130
90
69
53
37
32
23
18
10
12
12
15
17
PEG126MF325EQ
PEG126MG337EQ
PEG126MH347EQ
PEG126MJ368EQ
PEG126ML390EQ
40 VDC (UR )
470
600
1000
1200
1500
2200
2700
16 x 29
16 x 37
20 x 29
20 x 29
20 x 29
20 x 37
20 x 46
1.1
1.4
1.9
2.0
2.2
2.8
3.1
5.9
8.3
9.4
9.0
9.7
11.4
12.1
3.5
4.9
5.5
5.3
5.7
6.7
7.1
63 VDC (UR )
1.3
1.9
2.1
2.0
2.2
2.6
2.7
250
370
470
680
900
16 x 29
16 x 37
20 x 29
20 x 37
20 x 46
0.9
1.2
1.4
1.7
2.1
5.3
6.7
7.3
9.0
10.5
3.1
3.9
4.3
5.3
6.1
1.2
1.5
1.6
2.0
2.3
* Maximum specified values
customer design
On request PEG126 can be designed in other capacitance values and case sizes.
intermittent ripple current
During intermittent operation, the PEG 126-capacitors allows a significant increase of ripple current compared with specified values (IRAC
at continoues operation). Increased ripple current, with up to x1.95, is allowed at max 25% intermittence.
Hot-spot temperature during operation:
Max 135°C (see diagram)
LOP = 4700h
Example 2
Article: PEG126KL427
23A, 5kHz during 140 s, period time 17 minutes
(14.7 minutes without ripple, per cycle)
Ambient temperature: 105°C
→
Hot-spot temperature during operation:
Max 135°C
LOP = 4700h
10
10
120
110
20
100
0
1000
2000
Ripple Current (A)
→
Hot-spot temperature
10
Temperature (°C)
Example 1
Article: PEG126KL427
23A, 5kHz during 30 s, period time 120 s
(90 s without ripple)
Ambient temperature: 105°C
0
000
Time (s)
Th
IAC
Operational life can be calculated for arbitrary intermittence.
Please contact Customer Support.
© KEMET 2006. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without KEMET's prior express consent is prohibited.
31
PEG 126
OPERATIONAL LIFE AND RIPPLE CURRENT
Operational life (Lop), at ambient temperature Ta and ripple current IAC.
Diagram valid for ø20- case size.
Operational life, Ø16- case size: 0.75 x diagram value
Example:
Article: PEG126KJ422EQ (Ø20 x 37 mm)
Ambient temperature (Ta): 85°C
Ripple current, at 10kHz (IAC ): 12 A
2,5
raC
IRAC(125°C, ≥5kHz)= 6.7A (from data table)
→ IAC/ IRAC(125°C)= 12 / 6.7= 1.8
aC
Operational life: Interpolation between the
Lop-curves → Lop ~18kh (blue curves)
op
When the capacitor load is at 100Hz,
use IAC / IRAC(125°C, 100Hz) as input value to
the diagram (see data table). At other frequencies
use IAC/ IRAC(125°C, ≥5kHz) x 1/Corr =
Frequency correction factor, for ripple current (Corr):
Frequency
300 Hz
1 kHz
5 kHz
100 kHz
Correction factor (Corr)
(Typical value)
0.57
0.80
1.00
1.04
Reliability
LEakage current
Estimated field failure rate: < 2 ppm/year.
The expected failure rate, for this capacitor
range, is based on field experience for capacitors with structural similarity. This failure
rate is valued during first year of operation.
Expected failure rate thereafter: < 1 ppm/y.
(Until end of specified operational life)
Rated leakage current, IRL (µA)
Rated voltage, UR (V)
Rated capacitance, CR (µF)
IRL = 0.003 x CR x UR + 4
Ordering information
For further ordering information please see page 8.
PEG
1
2
6KF
3
4
7E
QE
1
1
4
5
6
9
10 11 13 15 2
3
7
8
12 14 16 17 18 19
20
Capacitance tolerances:
E1: Packed in boxes
Pos. 13: Q: –10 to +30%
M: -20 to +20%
Quantities and weights
CASE CODE Weight approx (g) Standard box quantity
F
G
H
J
8
125
11 100
13
150
20
125
L 24
100
Statements of suitability for certain applications are based on our knowledge of typical operating conditions for such applications, but are not intended to constitute –
and we specifically disclaim – any warranty concerning suitability for a specific customer application or use. This Information is intended for use only by customers who
have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise
provided by us with reference to the use of our products is given gratis, and we assume no obligation or liability for the advice given or results obtained.
32
© KEMET 2006. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without KEMET's prior express consent is prohibited.