PHE841 RoHS Compliant • EMI suppressor, class X1, metallized polypropylene • 0.01 – 2.2 µF, 330 VAC, +100°C L typical applications For worldwide use as electromagnetic interference suppressor in all X1 and across-the-line applications. B Construction Metallized polypropylene winding, encapsulated in self-extinguishing material meeting the requirements of UL 94 V–0. H 0.5 Not for use in series with the mains. See www.kemet.com for more information. Rated voltage 330 VAC 50/60 Hz Capacitance range 0.01 – 2.2 µF Capacitance tolerance ± 20% standard, ± 10% option Temperature range –40 to +100°C Climatic category 40/100/56/B Approvals ENEC, UL, cUL Dissipation factor tanδ Maximum values at +23°C C ≤ 0.1 µF 0.1µF < C ≤ 1 µF 1 kHz 0.1% 0.1% 10 kHz 0.2% 0.4% 100 kHz 0.6% – ∅d p Technical data C > 1 µF 0.1% 0.8% – Test voltage between terminals The 100% screening factory test is carried out at 3000 VDC. The voltage level is selected to meet the requirements in applicable equipment standards. All electrical characteristics are checked after the test. Resonance frequency Tabulated self-resonance frequencies f0 refer to 5 mm lead length. Insulation resistance C ≤ 0.33 µF: ≥ 30 000 MΩ C > 0.33 µF: ≥ 10 000 s In DC applications Recommended voltage: ≤ 1000 VDC p d std l max l b 10.0 ± 0.4 15.0 ± 0.4 22.5 ± 0.4 27.5 ± 0.4 37.5 ± 0.5 0.6 0.8 0.8 0.8 1.0 17 17 6 6 6 30 30 30 30 30 ±0.4 ±0.4 ±0.4 ±0.4 ±0.7 Tolerance in lead length < 30 mm +0 mm –1 30 mm +5 –0 mm Environmental test data Endurance EN/IEC 60384-14:2005 1.25 x UR VAC 50 Hz, once every hour increased to 1000 VAC for 0.1 s, 1000 h at upper rated temperature Vibration IEC 60068–2–6 Test Fc 3 directions at 2 hours each, 10–55 Hz at 0.75 mm or 98 m/s2 No visible damage No open or short circuit Bump IEC 60068–2–29 Test Eb 1000 bumps at 390 m/s2 No visible damage No open or short circuit Upper and lower rated temperature 5 cycles No visible damage Change of temperature IEC 60068–2–14 Test Na Active flammability EN/IEC 60384-14:2005 Passive flammability Enclosure material of UL94V–0 flammability class Humidity IEC 60068-2-3 Test Ca +40°C and 90 – 95% R.H. l b 56 days PHE841 article table Capaci-BoxMax dimensionsMax tance codein mm fO dU/dtArticle code µF BHLMHzV/µs Capaci-BoxMax dimensionsMax tance codein mm fO dU/dtArticle code µF BHLMHzV/µs Lead spacing 27.5 mm Lead spacing 10 mm 0.010 0.012 0.015 0.018 0.022 A02 A03 A03 A04 A04 4.5 5.0 5.0 6.0 6.0 10.5 11.0 11.0 12.0 12.0 13.0 13.0 13.0 13.0 13.0 11 10 9.4 8.7 8.1 100 100 100 100 100 PHE841EA5100MR17 PHE841EA5120MR17 PHE841EA5150MR17 PHE841EA5180MR17 PHE841EA5220MR17 Lead spacing 15 mm 0.010 0.012 0.015 0.018 0.022 0.027 0.033 0.039 0.047 0.056 0.068 0.082 0.10 B04 B04 B04 B04 B05 B15 B10 B06 B06 B12 B11 B14 B14 5.5 5.5 5.5 5.5 5.5 6.0 6.5 7.5 7.5 8.0 8.5 9.5 9.5 10.5 10.5 10.5 10.5 12.5 12.0 12.5 14.5 14.5 15.0 16.0 17.5 17.5 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 18.0 10 9.4 8.7 7.9 7.2 6.5 5.9 5.4 5.0 4.6 4.2 3.8 3.7 100 100 100 100 100 100 100 100 100 100 100 100 100 PHE841EB5100MR17 PHE841EB5120MR17 PHE841EB5150MR17 PHE841EB5180MR17 PHE841EB5220MR17 PHE841EB5270MR17 PHE841EB5330MR17 PHE841EB5390MR17 PHE841EB5470MR17 PHE841EB5560MR17 PHE841EB5680MR17 PHE841EB5820MR17 PHE841EB6100MR17 0.22 0.27 0.33 0.39 0.47 0.56 0.68 0.82 1.0 F11 F11 F12 F03 F03 F13 F14 F15 F16 10.5 10.5 11.5 13.5 13.5 14.5 17.5 19.0 21.0 20.5 20.5 22.5 23.0 23.0 24.5 28.0 29.0 30.0 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 2.0 1.8 1.6 1.4 1.3 1.2 1.1 1.0 1.0 100 100 100 100 100 100 100 100 100 PHE841EF6220MR06L2 PHE841EF6270MR06L2 PHE841EF6330MR06L2 PHE841EF6390MR06L2 PHE841EF6470MR06L2 PHE841EF6560MR06L2 PHE841EF6680MR06L2 PHE841EF6820MR06L2 PHE841EF7100MR06L2 Lead spacing 37.5 mm 0.68 0.82 1.0 1.2 1.5 1.8 2.2 * R05 R04 R04 R02 R03 R06 R06 13.0 15.0 15.0 16.5 19.0 21.0 21.0 24.0 26.0 26.0 32.0 36.0 38.0 38.0 41.0 41.0 41.0 41.0 41.0 41.0 41.0 1.1 1.0 0.92 0.84 0.74 0.67 0.60 100 100 100 100 100 100 100 PHE841ER6680MR06L2 PHE841ER6720MR06L2 PHE841ER7100MR06L2 PHE841ER7120MR06L2 PHE841ER7150MR06L2 PHE841ER7180MR06L2 PHE841ER7220MR06L2 Only ±20 % Lead spacing 22.5 mm 0.068 0.082 0.10 0.12 0.15 0.18 0.22 0.27 0.33 0.39 0.47 D13 D17 D17 D14 D15 D18 D18 D16 D16 D19 D19 6.5 7.0 7.0 8.0 9.0 10.5 10.5 11.0 11.0 15.5 15.5 14.5 16.5 16.5 16.0 18.5 19.0 19.0 21.5 21.5 24.5 24.5 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 26.0 2.9 2.8 2.7 2.6 2.5 2.3 2.2 2.0 1.9 1.6 1.5 100 100 100 100 100 100 100 100 100 100 100 PHE841ED5680MR06L2 PHE841ED5820MR06L2 PHE841ED6100MR06L2 PHE841ED6120MR06L2 PHE841ED6150MR06L2 PHE841ED6180MR06L2 PHE841ED6220MR06L2 PHE841ED6270MR06L2 PHE841EY6330MR06L2 * PHE841ED6390MR06L2 PHE841ED6470MR06L2 Marking Approvals Certification BodySpecification ENEC EN/IEC 60384-14:2005 UL UL 60384-14 CAN/CSA-E60384-14:09 • • • • • • • • • • RIFA RIFA article code Rated capacitance Capacitance tolerance code Rated voltage X1 Approval marks Manufacturing date code IEC climatic category Passive flammability class Ordering information The article code for the standard part is given in the article table. Statements of suitability for certain applications are based on our knowledge of typical operating conditions for such applications, but are not intended to constitute – and we specifically disclaim – any warranty concerning suitability for a specific customer application or use. This Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise provided by us with reference to the use of our products is given gratis, and we assume no obligation or liability for the advice given or results obtained.