PHE844 RoHS Compliant •EMI suppressor, class X1, metallized polypropylene •0.1 – 2.2 µF, 440 VAC/480 VAC, +105°C L typical applications For worldwide use as electromagnetic interference suppressor in all X1 and across-the-line applications. B Construction Series winding of metallized polypropylene. Encapsulated in self-extinguishing material meeting the requirements of UL 94 V–0. H 0.5 Not for use in series with the mains. See www.kemet.com for more information. ∅d p Technical data Rated voltage 440 VAC 50/60 Hz (ENEC) 480 VAC 50/60 Hz (UL, CSA) Capacitance range 0.1 – 2.2 µF Capacitance tolerance ± 20% standard, ± 10% option Temperature range –40 to +105°C Climatic category 40/105/56/B p d 22.5 ± 0.4 27.5 ± 0.4 37.5 ± 0.5 l b std l max l b 0.8 6 30 0.8 6 30 1.0 6 30 ±0.4 ±0.4 ±0.7 Tolerance in lead length +0 < 30 mm –1 mm Approvals ENEC, UL, cUL Dissipation factor Maximum values at +23°C C ≤ 0.1 µF 0.1µF < C ≤ 1 µF 1 kHz 0.1% 0.1% 10 kHz 0.2% 0.4% 100 kHz 0.6% – 30 mm +5 –0 mm C > 1 µF 0.1% 0.8% – Test voltage between terminals The 100% screening factory test is carried out at 3000 VDC. The voltage level is selected to meet the requirements in applicable equipment standards. All electrical characteristics are checked after the test. Resonance frequency Tabulated self-resonance frequencies f0 refer to 5 mm lead length. Insulation resistance C ≤ 0.33 µF: ≥ 30 000 MΩ C > 0.33 µF: ≥ 10 000 s In DC application Recommended voltage: ≤1000VDC Environmental test data Endurance EN/IEC 60384-14:2005 1.25 x UR VAC 50 Hz, once every hour increased to 1000 VAC for 0.1 s, 1000 h at upper rated temperature Vibration IEC 60068–2–6 Test Fc 3 directions at 2 hours each, 10–55 Hz at 0.75 mm or 98 m/s2 No visible damage No open or short circuit Bump IEC 60068–2–29 Test Eb 1000 bumps at 390 m/s2 No visible damage No open or short circuit Change of temperature IEC 60068–2–14 Test Na Upper and lower rated temperature 5 cycles No visible damage Active flammability EN/IEC 60384-14:2005 Passive flammability EN/IEC 60384-14:2005 UL1414 Enclosure material of UL94V–0 flammability class Humidity IEC 60068-2-3 Test Ca +40°C and 90 – 95% R.H. 56 days 55 phe844 article table Capaci-BoxMax dimensionsMax tance codein mm fO dU/dtArticle code µF BHLMHzV/µs Lead spacing 22.5 mm 0.10 0.15 0.22 0.33 0.47 D14 8.0 16.0 26.0 D15 9.0 18.5 26.0 D16 11.0 21.5 26.0 D20 13.5 23.0 26.0 D19 15.5 24.5 26.0 3.2 2.6 2.1 1.8 1.5 100 100 100 100 100 PHE844RD6100MR06L2 PHE844RD6150MR06L2 PHE844RD6220MR06L2 PHE844RD6330MR06L2 PHE844RD6470MR06L2 Lead spacing 27.5 mm 0.22 0.33 0.47 0.68 1.0 F11 F03 F13 F14 F16 10.5 13.5 14.5 17.5 21.0 20.5 23.0 24.5 28.0 30.0 31.5 31.5 31.5 31.5 31.5 2.2 1.7 1.4 1.1 1.0 100 100 100 100 100 PHE844RF6220MR06L2 PHE844RF6330MR06L2 PHE844RF6470MR06L2 PHE844RF6680MR06L2 PHE844RF7100MR06L2 Lead spacing 37.5 mm 0.47 0.68 1.0 1.5 2.2 R05 R05 R04 R03 R06 13.0 13.0 15.0 19.0 21.0 24.0 24.0 26.0 36.0 38.0 41.0 1.3 100 PHE844RR6470MR06L2 41.0 1.1 100 PHE844RR6680MR06L2 41.0 0.92 100 PHE844RR7100MR06L2 41.0 0.74 100 PHE844RR7150MR06L2 41.0 0.60 100 PHE844RR7220MR06L2 Approvals Certification BodySpecification ENEC EN/IEC 60384-14:2005 UL UL 1283 UL 1414 (UR=480 VAC) (UR=250 VAC) cUL recognition C 22.2 No. 8 C 22.2 No. 1 (UR=480 VAC) (UR=250 VAC) Ordering information The article code for the standard part is given in the article table. For other options, see page 11. Marking • RIFA • RIFA article code • Rated capacitance • Capacitance tolerance code • Rated voltage • X1 • Approval marks • Manufacturing date code • IEC climatic category • Passive flammability class Statements of suitability for certain applications are based on our knowledge of typical operating conditions for such applications, but are not intended to constitute – and we specifically disclaim – any warranty concerning suitability for a specific customer application or use. This Information is intended for use only by customers who have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise provided by us with reference to the use of our products is given gratis, and we assume no obligation or liability for the advice given or results obtained.