PHE844 - Kemet

PHE844 RoHS
Compliant
•EMI suppressor, class X1, metallized polypropylene
•0.1 – 2.2 µF, 440 VAC/480 VAC, +105°C
L
typical applications
For worldwide use as electromagnetic
interference suppressor in all X1 and
across-the-line applications.
B
Construction
Series winding of metallized polypropylene.
Encapsulated in self-extinguishing material
meeting the requirements of UL 94 V–0.
H
0.5
Not for use in series with the mains.
See www.kemet.com for more information.
∅d
p
Technical data
Rated voltage
440 VAC 50/60 Hz (ENEC)
480 VAC 50/60 Hz (UL, CSA)
Capacitance range
0.1 – 2.2 µF
Capacitance tolerance
± 20% standard, ± 10% option
Temperature range
–40 to +105°C
Climatic category
40/105/56/B
p
d
22.5 ± 0.4
27.5 ± 0.4
37.5 ± 0.5
l
b
std l
max l b
0.8 6 30
0.8 6 30
1.0 6 30
±0.4
±0.4
±0.7
Tolerance in lead length
+0
< 30 mm –1 mm
Approvals
ENEC, UL, cUL
Dissipation factor
Maximum values at +23°C
C ≤ 0.1 µF 0.1µF < C ≤ 1 µF
1 kHz
0.1%
0.1%
10 kHz
0.2%
0.4%
100 kHz
0.6%
–
30 mm
+5
–0
mm
C > 1 µF
0.1%
0.8%
–
Test voltage between
terminals
The 100% screening factory test is carried out at 3000
VDC. The voltage level is selected to meet the
requirements in applicable equipment standards. All
electrical characteristics are checked after the test.
Resonance frequency
Tabulated self-resonance frequencies f0 refer to 5 mm
lead length.
Insulation resistance
C ≤ 0.33 µF: ≥ 30 000 MΩ
C > 0.33 µF: ≥ 10 000 s
In DC application
Recommended voltage: ≤1000VDC
Environmental test data
Endurance
EN/IEC 60384-14:2005
1.25 x UR VAC 50 Hz,
once every hour increased
to 1000 VAC for 0.1 s,
1000 h at upper rated temperature
Vibration
IEC 60068–2–6
Test Fc
3 directions at 2 hours each, 10–55 Hz at 0.75 mm or 98 m/s2
No visible damage
No open or short circuit
Bump
IEC 60068–2–29
Test Eb
1000 bumps at
390 m/s2
No visible damage
No open or short circuit
Change of temperature
IEC 60068–2–14
Test Na
Upper and lower rated
temperature 5 cycles
No visible damage
Active flammability
EN/IEC 60384-14:2005
Passive flammability
EN/IEC 60384-14:2005
UL1414
Enclosure material of
UL94V–0 flammability class
Humidity
IEC 60068-2-3
Test Ca
+40°C and
90 – 95% R.H.
56 days
55
phe844
article table
Capaci-BoxMax dimensionsMax
tance codein mm
fO dU/dtArticle code
µF
BHLMHzV/µs
Lead spacing 22.5 mm
0.10
0.15
0.22
0.33
0.47
D14 8.0 16.0 26.0
D15 9.0 18.5 26.0
D16 11.0 21.5 26.0
D20 13.5 23.0 26.0
D19 15.5 24.5 26.0
3.2
2.6
2.1
1.8
1.5
100
100
100
100
100
PHE844RD6100MR06L2
PHE844RD6150MR06L2
PHE844RD6220MR06L2
PHE844RD6330MR06L2
PHE844RD6470MR06L2
Lead spacing 27.5 mm
0.22
0.33
0.47
0.68
1.0
F11
F03
F13
F14
F16
10.5
13.5
14.5
17.5
21.0
20.5
23.0
24.5
28.0
30.0
31.5
31.5
31.5
31.5
31.5
2.2
1.7
1.4
1.1
1.0
100
100
100
100
100
PHE844RF6220MR06L2
PHE844RF6330MR06L2
PHE844RF6470MR06L2
PHE844RF6680MR06L2
PHE844RF7100MR06L2
Lead spacing 37.5 mm
0.47
0.68
1.0
1.5
2.2
R05
R05
R04
R03
R06
13.0
13.0
15.0
19.0
21.0
24.0
24.0
26.0
36.0
38.0
41.0 1.3 100 PHE844RR6470MR06L2
41.0 1.1 100 PHE844RR6680MR06L2
41.0 0.92 100 PHE844RR7100MR06L2
41.0 0.74 100 PHE844RR7150MR06L2
41.0 0.60 100 PHE844RR7220MR06L2
Approvals
Certification BodySpecification
ENEC
EN/IEC 60384-14:2005
UL
UL 1283 UL 1414 (UR=480 VAC)
(UR=250 VAC)
cUL recognition
C 22.2 No. 8 C 22.2 No. 1 (UR=480 VAC)
(UR=250 VAC)
Ordering information
The article code for the standard part is given in the article table.
For other options, see page 11.
Marking
• RIFA
• RIFA article code
• Rated capacitance
• Capacitance tolerance code
• Rated voltage
• X1
• Approval marks
• Manufacturing date code
• IEC climatic category
• Passive flammability class
Statements of suitability for certain applications are based on our knowledge of typical operating conditions for such applications, but are not intended to constitute –
and we specifically disclaim – any warranty concerning suitability for a specific customer application or use. This Information is intended for use only by customers who
have the requisite experience and capability to determine the correct products for their application. Any technical advice inferred from this Information or otherwise
provided by us with reference to the use of our products is given gratis, and we assume no obligation or liability for the advice given or results obtained.