Isolated 1W Single&Dual Output DC/DC Converters

H-XM&G-XM Series
1W,Isolated 6000VDC Unregulated Single&Dual Output DC/DC Converters
SELECTION GUIDE
Input
Output
Voltage
Voltage
Output
Current
(V)
(V)
(MA)
G0505XM
5
±5
G0509XM
5
±9
FEATURES
G0512XM
5
G0515XM
RoHS compliant
Capacitate
±100
40
60
3.0
4950
±55
30
65
3.0
3832
±12
±42
20
65
3.0
2770
5
±15
±33
20
65
3.0
1903
G1205XM
12
±5
±100
40
60
3.0
3688
G1209XM
12
±9
±55
30
65
3.0
3029
G1212XM
12
±12
±42
20
65
3.0
2324
G1215XM
12
±15
±33
20
65
3.0
1682
G2424XM
24
±24
±21
20
64
3.0
1580
H0303XM
3.3
3.3
303
70
66
3.0
13780
load,-40℃~85℃
H0503XM
5
3.3
303
60
64
3.0
13460
H0505XM
5
5
200
50
68
3.0
13360
Single and dual output
H0509XM
5
9
111
50
72
3.0
12700
H0512XM
5
12
83
50
71
3.0
11490
H0515XM
5
15
66
50
71
3.0
9980
H1205XM
12
5
200
50
69
3.0
8447
H1209XM
12
9
111
50
73
3.0
8176
H1212XM
12
12
83
50
73
3.0
7660
H1215XM
12
15
66
50
74
3.0
6950
H2424XM
24
24
42
50
74
3.0
6840
◆
Efficiency up to 80%
◆
Power density up to 0.42W/cm3
◆
Wide temperature performance at full 1 Watt
◆
UV 94V-0 package material
◆
No heat sink required
◆
◆
3.3V,5V,12V,24V input
Industry standard pin out
◆
Footprint 1.91cm2
◆
6KVDC isolation
◆
3.3V,5V,9V,12V and 15V output
◆
◆
Parameter
Single-in-Line Package (SIP7)
Voltage range
Low coupling capacity
No external components required
◆
◆
Physical Clearance of Isolation Barrier 2.5 mm min.
Custom solutions available
Conditions
Min.
Typ.
Max
Units
2.97
3.3
3.63
V
Continuous operation,5V input types
4.5
5
5.5
V
Continuous operation,12V input types
10.8
12
13.2
V
Continuous operation,24V input types
21.6
24
26.4
Input current full load
MODEL SELECTION
③
④
②Input Voltage
④Fixed Input
APPLICATIONS
The H-XM&G-XM series are dual and single output DC/DC
converters in a 7 pin SIP package style offering pin and
functionality compatibility with the E series SIP DC/DC
converters.
The H_XM&G_XM series is Ul60950 recognized and suitable for
applications where safety and miniaturization are of paramount
importance.Isolation
barrier
approved
for
supplementary/reinforced insulation.
mA
12 Vin models
30
mA
5 Vin models
300
mA
12 Vin models
125
mA
0.3
Internal capacitor
Short-circuit protection3
1 second
Lead temperature 1.5mm from case for 10 seconds
300℃
Input voltage VIN,H/G03 types
5V
Input voltage VIN,H/G05 types
7V
Input voltage VIN,H/G12 types
15V
Ripple and noise (20 MHz Bandwidth)
120 mV pk-pk typ.
Voltage set accuracy
± 3%
Voltage balance (dual output models)
± 1 % max.
Temperature coefficient
± 0.02 % / K
Frequency change over line and load
± 30 % max.
Humidity (non condensing)
95 % rel H max.
Derating above 85℃
5%/K
1.Calculated using MIL-HDBK-217FN2 calculation model with nominal input voltage at full load.
2.See ripple & noise test method.
MICRODC R ESERVES THE COPYRIGHT
3.Supply voltage must be disconnected at the end of the short circuit duration.
All specifications typical at TA=25°C,nominal input voltage and rated output current unless otherwise specified.
http://www.microdc.cn
V
55
ABSOLUTE MAXIMUM RATINGS
⑤
H 05 05 X M
①Product Series
③Output Voltage
⑤Mini SIP7 Package
5 Vin models
Reverse voltage protection
Input filter
②
(PF)
Continuous operation,3V input types
Input current no load
MTTF up to 1.3 million hours
①
Ripple&Noise2
INPUT CHARACTERISTICS
◆
◆
MTTF1
(KHRS)
Efficiency
(%)
◆
◆
Isolation
(MA)
Order code
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 1 of 4
A
H-XM&G-XM Series
OUTPUT CHARACTERISTICS
Parameter
Rated Power1
Voltage Set Point
Line regulation
Conditions
Min.
Typ.
TA=-40℃~60℃
Max.
Units
1
W
%%
See tolerance envelope
High Vin to low Vin
1.0
1.2
10% load to rated load,xx03
10.0
15.0
Load regulation
10% load to rated load,0505
7.0
10.0
Single outputs
10% load to rated load,0509,0512,0515
6.0
10.0
10% load to rated load,12xx
5.0
7.0
10% load to rated load,5V output types
10.0
15.0
Load regulation
10% load to rated load,9V output types
6.0
10.0
Dual outputs
10% load to rated load,12V output types
6.0
10.0
10% load to rated load,15V output types
6.0
10.0
All types
250
Zero Load Power
%
%
MW
ISOLATION CHARACTERISTICS
Parameter
Isolation test voltage
Resistance
Conditions
Min.
Flash tested for 1 second
6000
Viso=500VDC
Typ.
Max.
Units
VDC
1
GΩ
Isolation voltage
I/O isolation voltage
3000
VAL rms
Isolation capacity
Input/Output
10
pF
Isolation resistance
Input/Output
>1000
M ohm
GENERAL CHARACTERISTICS
Parameter
Switching frequency
Package weight
Conditions
Min.
Typ.
Single output
50
Dual output
70
Single/Dual models
Max.
Units
kHz
4.0(0.14 )
g (oz)
Max.
Units
TEMPERATURE CHARACTERISTICS
Parameter
Conditions
Min.
Specification
All output types
Storage
Case Temperature above
Typ.
-40
60
-55
130
All output types
TEMPERATURE DERATING GRAPH
℃
33
TOLERANCE ENVELOPE
H-XM/G-XM
3.3V in,3V out type only
1.See derating graph.
All specifications typical at TA=25°C, nominal input voltage and rated output current unless otherwise specified.Another 24V& 48V products, please inquire Our technical department!
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 2 of 4
H-XM&G-XM Series
TECHNICAL NOTES
ISOLATION VOLTAGE
"Hi Pot Test","Flash Tested","Withstand Voltage","Proof Voltage","Dielectric Withstand Voltage"&”Isolation Test Voltage" are all terms that relate to the same thing, a test voltage.
Applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Professional Power Module H_XM&G_XM series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 6KVDC for 1 second.
A question commonly asked is,"What is the continuous voltage that can be applied across the part in normal operation?"
The H_XM&G_XM series has been recognized by Underwriters Laboratory to 300Vrms for Supplementary Insulation and 150Vrms for Reinforced Insulation.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials.
Construction and environment. We therefore strongly advise against repeated high voltage isolation testing. but if it is absolutely required, that the voltage be reduced by 20% from
specified test voltage.
OUTPUT RIPPLE REDUCTION
By using the values of inductance and capacitance stated, the output ripple at the rated load is lowered to 5mV p-p max.
Component selection
Capacitor: Ceramic chip capacitors are recommended. It is required that the ESR(Equivalent Series Resistance)should be as low as possible.X7R types are recommended.
The voltage rating should be at least twice(except for 15V output),the rated output voltage of the DC/DC converter.
Inductor: The rated current of the inductor should not be less than of the output of the DC/DC converter. At the rated current, the DC resistance of the inductor should be
such that the voltage drop across the inductor is <2% of the rated voltage of the DC/DC converter. The SRF(Self Resonant Frequency) should be >20MHz.
Single output types
Dual output types
OUTPUT RIPPLE REDUCTION
Ripple & Noise Characterisation Method
Ripple and noise measurements are performed with the following test configuration.
C1
1uF X7R multilayer ceramic capacitor, voltage rating to be a minimum of 3 times the output voltage of the DC/DC converter
C2
10uF tantalum capacitor, voltage rating to be a minimum of 1.5 times the output voltage of the DC/DC converter
C3
100nF multilayer ceramic capacitor, general purpose
R1
450Ω resistor, carbon film,±1% tolerance
R2
50Ω BNC termination
T1
3T of the coxa cable through a ferrite toroid
RLOAD
Resistive load to the maximum power rating of the DC/DC converter. Connections should be made via twisted wires
R3
50Ω resistor, carbon film,±1%
Measured values are multiplied by 10 to obtain the specified values.
Differential Mode Noise Test Schematic
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 3 of 4
H-XM&G-XM Series
MECHANICAL DIMENSIONS
PIN CONNECTIONS
SIP package
SINGLE OUTPUT
DUAL OUTPUT
PIN CONNECTIONS-7 PIN SIP
PIN CONNECTIONS-7 PIN SIP
pin
Function
pin
Function
1
+VIN
1
+VIN
2
-VIN
2
-VIN
5
-VOUT
5
-VOUT
7
+VOUT
6
0V(COMMON)
7
+VOUT
*Pin not fitted on single output variants.
All dimensions in inches ±0.01(mm±0.25mm).All pins on a 0.1(2.54) pitch and within ±0.01(0.25)of true
position.
Weight: 4.0g
PACKAGE SPECIFICATIONS
RECOMMENDED FOOTPRINT DETAILS
7 Pin SIP Package
*Hole not required for single output variants.
Unless otherwise stated all dimensions in inches ±0.01(mm ±0.25mm).
TUBE OUTLINE DIMENSIONS
7 Pin SIP Tube
Unless otherwise stated all dimensions in inches ±0.02(mm ±0.5mm).
Tube length(7 Pin SIP):20.669(525mm±2mm).
Tube Quantity:25
RoHS COMPLIANT INFORMATION
This series is compatible with RoHS soldering systems with a peak wave solder temperature
of 300°C for 10 seconds.
The pin termination finish on the SIP package type is Tin Plate, Hot Dipped over Matte Tin
with Nickel Preplate. The DIP types are Matte Tin over Nickel Preplate. Both types in this
series are backward compatible with Sn/Pb soldering systems.
Microdc Professional Power Module,Inc.
Tel:0086-20-86000646
E-mail:[email protected]
Website:http://www.microdc.cn
Microdc Professional Power module,Inc.makes no representation that
the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or
future patent rights. Specifications are subject to change without notice.
2010 Microdc Professional Power Module, Inc. Guangzhou
http://www.microdc.cn
REACH COMPLIANT INFORMATION
This series has proven that this product does not contain harmful chemicals, it also has
harmful chemical substances through the registration, inspection and approval.
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 4 of 4