H-XVD&G-XVD Series FEATURES

H-XVD&G-XVD Series
1W,FIXED INPUT,6000V ISOLATED&UNREGULATED SINGLE/DUAL OUTPUT DC-DC CONVERTER
PRODUCT PROGRAM
Input
Efficiency
(%,Typ)
Switching
Frequency
(KHz,Typ)
20
70
UL
12
72
UL
84
9
73
UL
15
67
7
74
UL
G0505XVD
±5
±100
±10
70
UL
DIP24 Package
G0509XVD
±9
±56
±6
71
UL
G0512XVD
±12
±42
±5
72
UL
6KVDC Isolation
G0515XVD
±15
±33
±4
73
UL
H1205XVD
5
200
20
70
UL
H1209XVD
9
111
12
71
UL
H1212XVD
12
84
9
72
UL
H1215XVD
15
67
7
74
UL
G1205XVD
±5
±100
±10
70
UL
G1209XVD
±9
±56
±6
71
UL
G1212XVD
±12
±42
±5
72
UL
G1215XVD
±15
±33
±4
75
UL
Max
Min
H0505XVD
5
200
H0509XVD
9
111
H0512XVD
12
Voltage(VDC)
Nominal
FEATURES
◆
◆
◆
H0515XVD
Small Footprint
◆
Temperature Range: -40℃~+85℃
◆
No Heat Sink Require
◆
◆
Output
Voltage
(VDC)
Order code
No External Component Require
Internal SMD Construction
◆
Industry Standard Pin out
◆
RoHS Compliance
②
③
④
⑤
12
ISOLATION
MODEL SELECTION
①
5
Item
⑥
H 05 05 X V D
Isolation voltage
①Product Series
②Input Voltage
③Output Voltage
④Fixed Input
⑤Footprint Rank Shape ⑥DIP24 Package
Isolation resistance
Range
4.5-5.5
10.8-13.2
Current
SPECIFICATIONS
Test Conditions
Min
Tested for 1 minute and 1mA max
6000
Test at 1000VDC
1000
Isolation capacitance
Typ
Max
Units
VDC
MΩ
3.5
pF
APPLICATIONS
The G-XVD& H-XVD Series are
specially designed for applications where a
group of polar power supplies are isolated
from the input power supply in a distributed
power supply system on a circuit board.
These products apply to:
1) Where the voltage of the input power
supply is fixed (voltage variation ≤10%);
2) Where isolation is necessary between
input and output (isolation voltage
≤6000VDC);
3) Where the regulation of the output
voltage and the output ripple noise are not
demanded.
Such as: purely digital circuits, ordinary low
frequency analog circuits, and IGBT power
device driving circuits.
COMMON SPECIFICATIONS
Item
Test Conditions
Min
Typ
Storage humidity range
Max
Units
95
%
Operating temperature
-40
85
Storage temperature
-55
125
Temp. rise at full load
Lead temperature
Short circuit protection*
15
1.5mm from case for 10 seconds
300
5V input voltage
1
12V input voltage
S
Continuous
Cooling
Free air convection
Case material
MTBF
℃
30
Plastic(UL94-V0)
3500
Weight
K hours
8.2
* When input voltage (Nominal) is 5V, Supply voltage must be discontinued at the end of short circuit
MICRODC R ESERVES THE COPYRIGHT
http://www.microdc.cn
duration.
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 1 of 2
g
H-XVD&G-XVD Series
OUTPUT SPECIFICATIONS
Item
Test conditions
Min
Output power
If
Typ
0.1
Line regulation
Load regulation
Recommended testing and application circuit
For Vin change of 1%
Max
Units
1
W
to
further
decrease
the
the
input/output ripple, an
input
and
output
ends of the DC/DC converter, see (Figure 1).
±1.2
10% to 100% load 5V output
10
15
10% to 100% load 9V output
8.3
15
10% to 100% load 12V output
6.8
15
10% to 100% load 15V output
6.3
15
Output voltage accuracy
you want
“ LC ” filtering network may be connected to
%
See tolerance envelope graph
Temperature drift
100% full load
Ripple & Noise*
20MHz Bandwidth
150
0.03
%/℃
200
mVp-p
It should also be noted that the inductance and the frequency of the
"LC" filtering network should be staggered with the DC/DC frequency to
avoid mutual interference. However, the capacitance of the output
filter capacitor must be proper. If the capacitance is too big, a
Switching frequency
Full load
5V input
12V input
nominal input
250
50
KHz
startup problem might arise. For every channel of
output,
provided the safe and reliable operation is ensured, the greatest
capacitance of its filter capacitor sees (Table 1).
EXTERNAL CAPACITOR TABLE (Table 1)
*Test ripple and noise by "parallel cable"method.
See detailed operation instructions at Testing of Power Converter section, application notes.
Note: Dual output models unbalanced load: ±5%.
%.
TYPICAL CHARACTERISTICS
Single
Cout
Dual
Vin
Cin
(VDC)
(uF)
5
4.7
5
10
±5
4.7
12
2.2
9
4.7
±9
2.2
24
1
12
2.2
±12
1
-
-
15
1
±15
1
Vout
(uF)
(VDC)
Vout
(VDC)
Cout
(uF)
It not recommend to connect any external capacitor in the
application field with less than 0.5 watt output.
Output Voltage Regulation and Over-voltage Protection Circuit
The simplest device for output voltage regulation, over-voltage and
over-current protection is a linear voltage regulator with overheat
protection that is connected to the input or output end in series (Figure 2).
Dual Output
OUTLINE DIMENSIONS & PIN CONNECTIONS
Overload Protection
Under normal operating conditions, the output circuit of
these products has no protection against overload. The simplest
method is to connect a self-recovery fuse in series at the input
end or add a circuit breaker to the circuit.
No parallel connection or plug and play
Note:
1. All specifications measured at Ta=25, humidity<75%,nominal input
voltage and rated output load unless otherwise specified.
2. Only typical models listed,
please contact
other models may be different,
our technical person
for more details.
3. Operation under minimum load will not damage the
converter; However, they may not meet all specification listed.
RoHS COMPLIANT INFORMATION
Microdc Professional Power Module,Inc.
Tel:0086-20-86000646
E-mail:[email protected]
Website:http://www.microdc.cn
Microdc Professional Power module,Inc.makes no representation that
the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or
future patent rights. Specifications are subject to change without notice.
2010 Microdc Professional Power Module, Inc. Guangzhou
http://www.microdc.cn
This series is compatible with RoHS soldering systems with a peak wave solder temperature
of 300°C for 10 seconds.
The pin termination finish on the SIP package type is Tin Plate, Hot Dipped over Matte Tin
with Nickel Preplate. The DIP types are Matte Tin over Nickel Preplate. Both types in this
series are backward compatible with Sn/Pb soldering systems.
REACH COMPLIANT INFORMATION
This series has proven that this product does not contain harmful chemicals, it also has
harmful chemical substances through the registration, inspection and approval.
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 2 of 2