A-XS-W25&B-XLS

A-XS-W25&B-XLS-W25 Series
0.25W, FIXED INPUT, ISOLATED&UNREGULATED DUAL/SINGLE OUTPUT DC-DC CONVERTER
PRODUCT PROGRAM
Input
Part
Number
B0303XLS-W25
FEATURES
Small Footprint
◆
1KVDC Isolation
Output
Voltage (VDC)
Nominal
Nominal
3.3
3.0-3.6
Voltage
(VDC)
Current (mA)
Efficiency
(%, Typ)
Max
3.3
75.8
62
B0305XLS-W25
5
50
65
A0505XS-W25
±5
±25
62
A0509XS-W25
±9
±13.8
64
A0512XS-W25
±12
±10.4
66
A0515XS-W25
±15
±8.3
65
◆
SIP Package
◆
Internal SMD Construction
◆
Temperature Range: -40℃to +85℃
◆
5
4.5-5.5
B0505XLS-W25
5
50
64
B0509XLS-W25
9
27.8
65
B0512XLS-W25
12
20.8
67
No Heat sink Required
B0515XLS-W25
15
16.7
65
No External Component Required
A1205XS-W25
±5
±25
62
A1209XS-W25
±9
±13.8
63
A1212XS-W25
±12
±10.4
64
A1215XS-W25
±15
±8.3
65
3.3
75.8
62
◆
◆
Industry Standard Pin out
◆
MODEL SELECTION
B1203XLS-W25
①
②
③ ④
⑤
⑥
B 05 05 X LS -W25
①Product Series
③Output Voltage
⑤Lengthened SIP Package
②Input Voltage
④Fixed Input
⑥Rated Power
APPLICATIONS
The A-XS-W25&B-XLS-W25 Series are
specially designed for applications where a
group of polar power supplies are isolated from
the input power supply in a distributed power
supply system on a circuit board.
These products apply to:
1) Where the voltage of the input power supply
is fixed (voltage variation ±10%);
2) Where isolation is necessary between input
and output (isolation voltage ±1000VDC);
3) Where the regulation of the output voltage
and the output ripple noise are not demanding.
Such as: purely digital circuits,ordinary low
frequency analog circuits, and IGBT power
device driving circuits.
12
10.8-13.2
B1205XLS-W25
5
50
65
B1209XLS-W25
9
27.8
66
B1212XLS-W25
12
20.8
67
B1215XLS-W25
15
16.7
66
A2405XS-W25
±5
±25
63
A2409XS-W25
±9
±13.8
64
A2412XS-W25
±12
±10.4
65
±15
±8.3
65
5
50
63
B2409XLS-W25
9
27.8
63
B2412XLS-W25
12
20.8
65
B2415XLS-W25
15
16.7
65
B2424XLS-W25
24
10.4
64
A2415XS-W25
B2405XLS-W25
24
21.6-26.4
COMMON SPECIFICATIONS
Item
Test conditions
Min
Typ
Storage humidity
Units
95
%
Operating Temperature
-40
85
Storage Temperature
-55
125
Temp. rise at full load
Lead temperature
15
1.5mm from case for 10 seconds
1
Cooling
s
Free air convection
Case material
MTBF
℃
25
300
Short circuit protection*
MICRODC RESERVES THE COPYRIGHT
Max
Plastic (UL94-V0)
3500
Weight
K hours
2.1
g
*Supply voltage must be discontinued at the end of short circuit duration.
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 1 of 2
A-XS-W25&B-XLS-W25 Series
ISOLATION SPECIFICATIONS
Item
APPLICATION NOTE
Test conditions
Min
Isolation voltage
Tested for 1 minute and 1 mA max
1000
Typ
Max
Units
VDC
Isolation resistance
Test at 500VDC
1000
MΩ
Requirement on output load
To ensure this module can operate efficiently and
reliably, During operation, the minimum output load
is not less than 10% of the full load, and that this
product should never be operated under no load! If
the actual output power is very small, please connect
OUTPUT SPECIFICATIONS
Item
a resistor with proper resistance at the output end in
Test conditions
Min
Typ
Output power
Line regulation
Max
Units
0.25
W
parallel to increase the load.
Overload Protection
For Vin change
(3.3V input)
±1.5
Under normal operating conditions, the output
of ±1%
(Others input)
±1.2
circuit of these products has no protection against
overload. The simplest method is to connect a
(3.3V output)
10% to 100%
Load regulation
12
20
(5V output)
10.5
15
(9V output)
8.3
15
(12V output)
6.8
15
(15V output)
6.3
15
self-recovery fuse in series at the input end or add a
%
load
Output voltage accuracy
Recommended circuit
If you want to further decrease the input/output
ripple, an "LC" filtering network may be connected to
the input and output ends of the DC/DC converter,
See tolerance envelope graph
Temperature drift
100% full load
Ripple & Noise*
20MHz Bandwidth
50
Switching frequency
Full load, nominal input
100
circuit breaker to the circuit.
0.03
%/℃
75
mVp-p
see (Figure 1).
KHz
*Test ripple and noise by "parallel cable" method. See detailed operation instructions at Testing .
Note:
1. All specifications measured at T A =25℃, humidity<75%, nominal input voltage and rated output load unless otherwise
specified.
2. See below recommended circuits for more details.
3. Dual output models unbalanced load: ±5%.
TYPICAL CHARACTERISTICS
it should also be noted that the inductance and the
frequency of the "LC" filtering network should be
staggered with the DC/DC frequency to avoid mutual
interference. However, the capacitance of the output
filter capacitor must be proper. If the capacitance is
too big, a startup problem might arise. It's not
recommended to connect any external capacitor in
the application field.
Output Voltage Regulation and
Over-voltage
Protection Circuit
OUTLINE DIMENSIONS & PIN CONNECTIONS
The simplest device for output voltage regulation,
over-voltage and over-current protection is a linear
voltage regulator with overheat protection that is
connected to the input or output end in series (Figure
2).
No parallel connection or plug and play.
http://www.microdc.cn
Technical Enquiries-Email:[email protected] Tel:0086-20-86000646
Page 2 of 2