 NHD‐320240WG‐AFFH‐TZ#001‐C Graphic Liquid Crystal Display Module NHD‐ 320240‐ WG‐ A‐ F‐ F‐ H‐ TZ#001‐C Newhaven Display 320 x 240 pixels Display Type: Graphic Model White CCFL Backlight FSTN (+) Transflective, 6:00 view, Wide Temperature (‐20°C ~+70°C) Interface Cable RoHS Compliant Newhaven Display International, Inc. 2511 Technology Drive, Suite 101 Elgin IL, 60124 Ph: 847‐844‐8795 Fax: 847‐844‐8796 www.newhavendisplay.com [email protected] [email protected] [1] Document Revision History Revision 0 1 Date 6/7/2007 4/20/2010 Description Initial Release User guide reformat Functions and Features •
•
•
•
•
320 x 240 pixels No Controller Driver NT7086 +5.0V power supply RoHS Compliant [2] Changed by ‐ MC Mechanical Drawing
13.0MAX
6.5
1.0
166.8 0.5
160.0±0.5
4.0
152.0
141.0
122.0(VA)
115.18(AA)
25.0
28.41
4.0
8.5
11.31
2.15
11.0
127.0±5.0
BHR-03VS-1
(JST)
PIN1
10.0
(Supporting tape length)
101.0
92.0(VA)
86.38(AA)
1.52
1.0
(PCB)
Supporting tape
CCFL B/L
37.9
0.30±0.05
(Terminal thickness)
The non-specified tolerance of dimension is ±0.3 mm .
w=0.8
p=1.25
1.25
P1.25*13=16.25
18.75
Contact Side
SCALE 2/1
0.36
0.34
0.36
0.34
5.0
1.0
4-3.5PTH
4-PAD
94.0 3.0
104.7
109.0 0.5
~
320*240 Dots
PIN3
1
DB0
2
DB1
3
DB2
4
DB3
5 DISPOFF
6
FLM
NC
7
8
CL1
9
CL2
10
Vdd
Vss
11
12
Vee
13
Vo
FGND
14
Newhaven Display
DOT SIZE
SCALE 10/1
NHD-320240WG-AFFH-TZ#001-C
Pin Description and Wiring Diagram Pin No. Symbol 1‐4 5 6 7 8 9 10 11 12 13 14 D0‐D3 DISPOFF FLM NC CL1 CL2 VDD VSS VEE V0 FGND External Connection MPU MPU MPU ‐
MPU MPU Power Supply Power Supply Power Supply Adj Power Supply Power Supply Function Description
Bi‐directional data bus lines.
Active LOW display off signal.
First line mark signal. (Scan start‐up signal)
No Connect
Data latch pulse
Data shift pulse
Power supply for logic (+5.0V)
Ground
Negative voltage output (‐25V)
Power supply for contrast (approx.
Frame ground
Recommended LCD connector: 1.25mm pitch, 14‐pos FFC connector Backlight connector: JST p/n: BHR‐03VS‐1 Mates with: JST p/n: SM03(4.0)B‐BHS‐1‐TB [4] Electrical Characteristics Item Operating Temperature Range Storage Temperature Range Supply Voltage Supply Current Supply for LCD (contrast) “H” Level input “L” Level input “H” Level output “L” Level output Backlight Supply Voltage Backlight Supply Current Backlight Lifetime Symbol Top Tst VDD IDD VDD‐VLCD VIH VIL VOH VOL VFL IFL Condition
Absolute Max
Absolute Max
‐
‐
‐
Min.
‐20
‐30
‐
70.0
22.0
0.8VDD
0
‐0.4VDD
‐
Typ.
‐
‐
5.0
75.0
24.0
‐
‐
‐
‐
VFL=328Vrms
IFL=5.0mArms
‐
3.0
‐
328
5.0
15,000
Ta=25°C, VDD=5.0V
Ta=25°C
Max. +70 +80 5.5 80.0 26.0 VDD 0.2VDD ‐ 0.4 ‐ 6.0 ‐ Unit
⁰C ⁰C V mA
V V V V V Vrms
mArms
Hrs
Max. 60 45 ‐ 300 200 Unit
⁰ ⁰ ‐ ms
ms
Optical Characteristics Item Viewing Angle ‐ Vertical Viewing Angle ‐ Horizontal Contrast Ratio Response Time (rise) Response Time (fall) Symbol AV AH Cr Tr Tf Condition
Cr ≥ 2
Cr ≥ 2
‐
‐
Min.
‐30
‐45
‐
‐
‐
Typ.
‐
‐
5
200
150
Driver Information Built‐in NT7086. Download specification at http://www.newhavendisplay.com/app_notes/NT7086.pdf [5] Timing Characteristics [6] [7] [8] Quality Information Test Item Content of Test High Temperature storage Endurance test applying the high storage temperature for a long time. Endurance test applying the low storage temperature for a long time. Endurance test applying the electric stress (voltage & current) and the high thermal stress for a long time. Endurance test applying the electric stress (voltage & current) and the low thermal stress for a long time. Endurance test applying the electric stress (voltage & current) and the high thermal with high humidity stress for a long time. Endurance test applying the electric stress (voltage & current) during a cycle of low and high thermal stress. Endurance test applying vibration to simulate transportation and use. Low Temperature storage High Temperature Operation Low Temperature Operation High Temperature / Humidity Operation Thermal Shock resistance Vibration test Static electricity test Test Condition Endurance test applying electric static discharge. 2 ‐30⁰C , 200hrs
1,2
+70⁰C 200hrs
2 ‐20⁰C , 200hrs
1,2
+60⁰C , 90% RH , 96hrs 1,2
‐20⁰C,30min ‐> 25⁰C,5min ‐> 70⁰C,30min = 1 cycle 10 cycles 10‐55Hz , 15mm amplitude. 60 sec in each of 3 directions X,Y,Z For 15 minutes VS=800V, RS=1.5kΩ, CS=100pF One time Note 1: No condensation to be observed. Note 2: Conducted after 4 hours of storage at 25⁰C, 0%RH. Note 3: Test performed on product itself, not inside a container. Precautions for using LCDs/LCMs See Precautions at www.newhavendisplay.com/specs/precautions.pdf Warranty Information and Terms & Conditions http://www.newhavendisplay.com/index.php?main_page=terms [9] Note
+80⁰C , 200hrs
3