NHD-5.7-640480WF-CTXL #

 NHD‐5.7‐640480WF‐CTXL# TFT (Thin‐Film‐Transistor) Color Liquid Crystal Display Module NHD‐ 5.7‐ 640480‐ WF‐ C‐ T‐ X‐ L‐ # Newhaven Display 5.7” Diagonal 640xRGBx480 pixels Model Built‐in driver + Controller White LED backlight TFT 12:00 view, Wide Temp RoHS Compliant Newhaven Display International, Inc. 2511 Technology Drive, Suite 101 Elgin IL, 60124 Ph: 847‐844‐8795 Fax: 847‐844‐8796 www.newhavendisplay.com [email protected] [email protected] Document Revision History Revision 0 1 Date 3/9/2009 6/18/2012 Description Initial Release Pin description updated Functions and Features •
•
•
•
640xRGBx480 resolution LED backlight 8‐bit parallel interface SSD1963 Controller [2] Changed by CL AK Mechanical Drawing
1
2
4
79.70
21.25
60.60
64.40
0.8
9.25
103.70
12.05
B
26.85
46.70
40.00
86.40(AA)
3.00
115.20(AA)
1.85
117.50(VA)
0.18
0.18
52.10
RGB
4-R0.8
C
RGB
31.95
88.70(VA)
Date
24.05
26.85
98.80±0.3
6
Description
A
31.95
40.00
5
4.20
B
C
Rev
12
3.50
2.35
3.89
1.50
1.81
A
3
0.06
Dots Size 30/1
5.70
5.95
8.30MAX
125.00±0.3
D
D
Date
06/18/12
1
2
3
4
[3]
Gen. Tolerance
Unit
±0.3mm
mm
5
Model:
NHD-5.7-640480WF-CTXL#
6
1
A
2
3
4
Rev
5
Date
21
CN2
A
16.00
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
4-PTH
22
32
1
CON1
1.00
1
1.00
1
28.6
24.5
Parts Area
24.0L*16.0W
CN1
25.30
50
p0.5*49=24.50
0.50
44.9
46.9
0.30
50
1
(Down-Side)
50
3.00
1
38.70
CON2
CON3
B
C
6
Description
79.60
GND
VDD
VO
A0
R/W
E
DB0
DB1
DB2
DB3
DB4
DB5
DB6
DB7
CS
UD
LR
RST
NC
NC
B
C
20.10
D
D
Date
06/18/12
1
2
3
4
[4]
Gen. Tolerance
Unit
±0.3mm
mm
5
Model:
NHD-5.7-640480WF-CTXL#
6
Pin Description Note: CON2 has a 20‐pin, 1.0mm pitch, Top‐Contact FFC Connector. Pins 21 and 22 are not connected. CON2: Pin No. Symbol 1 2 3 4 5 6 7‐14 15 16 17 18 19 20 GND VCC NC D/C# WR# RD# [DB0‐DB7] CS# U/D R/L RES# NC NC External Connection Power Supply Power Supply ‐
MPU MPU MPU MPU MPU MPU MPU MPU ‐
‐
Function Description
Ground
Power supply for LCD and logic (3.3V)
No Connect
Register Select signal – 0: Command, 1: Data
Active LOW Write signal, 8080 MPU interface
Active LOW Read signal, 8080 MPU interface
Bi‐directional data bus lines
Active LOW Chip Select signal
Scan direction 1: Up, 0: Down
Scan direction 1: Right, 0: Left
Active LOW Reset signal
No Connect
No Connect
Recommended LCD connector: 1.0mm pitch 20‐Conductor FFC. Molex p/n 52746‐2070 Backlight: Pin No. Symbol 1 2 VCC VCC External Connection Power Supply Power Supply Function Description
LED Anode (60mA @ 23.1V)
LED Cathode
Backlight connector: JST p/n: BHSR‐02VS‐1 Mates with: JST p/n: SM 02B‐BHSS‐1 [5] Controller Information Built‐in SSD1963 controller. Please download specification at http://www.newhavendisplay.com/app_notes/SSD1963.pdf 8080 Mode Interface: The 8080 mode MPU interface consists of CS#, D/C, RD#, WR#, and DB[7:0]. This interface uses WR# to define a write cycle and RD# to define a read cycle. If the WR# goes LOW when the CS# signal is LOW, the data or command will be latched into the system at the rising edge of WR#. Similarly, the read cycle will start when RD# goes LOW and end at the rising edge of RD#. See the SSD1963 datasheet for detailed timing diagrams. Command Instructions: See the SSD1963 datasheet for the Instruction Table and Command Descriptions. Pixel Data Format: [6] Electrical Characteristics Item Operating Temperature Range Storage Temperature Range Supply Voltage Supply Current Backlight Supply Current Backlight Supply Voltage Backlight Lifetime Symbol Top Tst VCC ICC IB VBL Condition
Absolute Max
Absolute Max
‐
VCC=3.3
Min.
‐20
‐30
3.0
‐
Typ.
‐
‐
3.3
190
60
23.1
25,000
Max. +70 +80 3.6 250 ‐ 24.5 ‐ Unit
⁰C ⁰C V mA
mA
V Hr ‐
‐
‐
‐
‐
10,000
Symbol Cr YL Tr Tr Condition
Cr ≥ 10
Cr ≥ 10
Cr ≥ 10
Cr ≥ 10
‐
‐
‐
‐
Min.
‐
‐
‐
‐
150
250
‐
‐
Typ.
60
40
60
60
250
300
25
25
Max. ‐ ‐ ‐ ‐ ‐ ‐ 40 40 Unit
⁰ ⁰ ⁰ ⁰ cd/m2
ms
ms
Optical Characteristics Item Viewing Angle – Top Viewing Angle – Bottom Viewing Angle – Left Viewing Angle – Right Contrast Ratio Luminance Response Time (rise) Response Time (fall) [7] Quality Information Test Item Content of Test High Temperature storage Endurance test applying the high storage temperature for a long time. Endurance test applying the low storage temperature for a long time. Endurance test applying the electric stress (voltage & current) and the high thermal stress for a long time. Endurance test applying the electric stress (voltage & current) and the low thermal stress for a long time. Endurance test applying the electric stress (voltage & current) and the high thermal with high humidity stress for a long time. Endurance test applying the electric stress (voltage & current) during a cycle of low and high thermal stress. Endurance test applying vibration to simulate transportation and use. Low Temperature storage High Temperature Operation Low Temperature Operation High Temperature / Humidity Operation Thermal Shock resistance Vibration test Static electricity test Test Condition Endurance test applying electric static discharge. 2 ‐30⁰C , 200hrs
1,2
+70⁰C 200hrs
2 ‐20⁰C , 200hrs
1,2
+60⁰C , 90% RH , 96hrs 1,2
‐20⁰C,30min ‐> 25⁰C,5min ‐> 70⁰C,30min = 1 cycle 10 cycles 10‐55Hz , 15mm amplitude. 60 sec in each of 3 directions X,Y,Z For 15 minutes VS=800V, RS=1.5kΩ, CS=100pF One time Note 1: No condensation to be observed. Note 2: Conducted after 4 hours of storage at 25⁰C, 0%RH. Note 3: Test performed on product itself, not inside a container. Precautions for using LCDs/LCMs See Precautions at www.newhavendisplay.com/specs/precautions.pdf Warranty Information and Terms & Conditions http://www.newhavendisplay.com/index.php?main_page=terms [8] Note
+80⁰C , 200hrs
3