application notes - NewHaven Display

User’s Guide
C-28-0704
VFD
(Vacuum Fluorescent Character Display Module)
For product support, contact
New haven Display International
2511 Technology Drive #101
E lgin , IL 601 24
Tel: (847) 8 44-8795
Fax: (847) 8 44-8796
October 31, 2006
Newhav en Display International
C-28-0704
October 31, 2006
Vacuum Fluorescent Display
Specification
PART NUMBER:
C-28-0704
FEATURES: 8 Digits, Seven Segmented, with Icons – DVD, SVCD
APPLICATION: Character Display (7-Seg)
RATINGS: Below
Panel Length
Panel Height
Panel Thickness
P.L.
P.H.
P.T.
112.0
25.0
6.8
mm
mm
mm
Leads
Lead Pitch
Lead Out
L.P.
-
2.54
SIL
Mm
Character Size
Character Height
Character Width
C.H.
C.W.
Multi
Multi
mm
mm
Outer Dimensions
Item
Symbol
Min.
Recommended
Max.
Unit
Filament Voltage
Peak Grid Voltage
Peak Anode Voltage
Cut-off Bias
Duty
Cycle
Pulse Width
Operating Temperature
Storage Temperature
Ef
Ec
Eb
Ek
Du
3.9
-
4.3
25.0
25.0
1/8
4.7
28.0
28.0
-
Vac
Vp-p
Vp-p
-
Tp
Topr
Tstg
-20
-55
100
-
+ 70
+ 85
uS
C
C
Green / Red / Yellow
Color of Illumination
-1-
C-28-0704
Electrical Characteristics
Item
Symbol
Test Condition
Min.
Typical
Max.
Unit
If
-
Ef = 4.3 Vac
eb = ec = 0
117.0
-
130.0
-
143.0
-
mAac
-
Anode Current
ib/1G
ib/2G
ib/3,4G
ib/5,6,7G
-
Ef = 4.3 Vac
eb = 25.0 Vp-p
ec = 25.0 Vp-p
Du = 1/8
tp = 100 uS
-
11.0
13.0
6.0
9.0
-
22.0
26.0
12.0
18.0
-
mAp-p
mAp-p
mAp-p
mAp-p
mAp-p
Grid Current
ic/1G
ic/2G
ic/3,4G
ic/5,6,7G
-
-
11.0
13.0
8.0
11.0
-
22.0
26.0
16.0
22.0
-
mAp-p
mAp-p
mAp-p
mAp-p
mAp-p
L(G)
350
(102)
35
(10)
60
(17)
700
(204)
70
(20)
120
(34)
-
cd/m2
(fL)
cd/m2
(fL)
cd/m2
(fL)
50
-
-
%
-4.5
-
-
Vdc
-4.5
-
-
Vdc
Filament Current
Luminance
L(R)
L(Y)
Lmin/Lmax
Luminance Ratio
Ecco
Grid Cut-off Voltage
Ebco
Anode Cut-off Voltage
Ef = 4.3 Vac
Eb = 25.0 Vdc
Ef = 4.3 Vac
ec = 25.0 Vp-p
Du = 1/8
tp = 100 uS
-2-
F= Filament,
G= Grid,
P= Anode,
NC= No Connect,
NP= No Pin
C28-0704
C28-0704
C28-0704