PART NUMBER:
D0420SD-42-2001FN
FEATURES: 4 Rows x 20 Digits, 5x7 Dot Matrix
APPLICATION: POS: Character Display (Dot Matrix)
RATINGS: Below
Panel Length
Panel Height
Panel Thickness
P.L.
P.H.
P.T.
120.0
42.0
9.0
mm
mm
mm
Leads
Lead Pitch
Lead Out
L.P.
-
1.27
DIL
mm
Character Size
Character Height
Character Width
C.H.
C.W.
5.0
3.0
mm
mm
Outer Dimensions
Item
Symbol
Min.
Recommended
Max.
Unit
Filament Voltage
Peak Grid Voltage
Peak Anode Voltage
Duty
Cycle
Pulse Width
Operating Temperature
Storage Temperature
Ef
ec
eb
Du
4.0
-
4.4
30.0
30.0
1/ 22
4.8
36.0
36.0
-
Vac
Vp-p
Vp-p
-
tp
Topr
Tstg
-40
-50
100
-
+ 85
+ 95
uS
C
C
Color of Illumination
Green
-1-
D0420SD-42-2001FN
Electrical
Characteristics
Symbol
Test Condition
Min.
Typical
Max.
Unit
If
-
Ef = 4.4 Vac
eb = ec = 0
180.0
-
200.0
-
220.0
-
mAac
-
-
10.0
-
20.0
-
mAp-p
mAp-p
mAp-p
mAp-p
mAp-p
Item
Filament Current
Anode Current
ib/1~20G
-
Grid Current
ic/1~20G
-
-
10.0
-
20.0
-
mAp-p
mAp-p
-
-
-
-
mAp-p
mAp-p
mAp-p
L(G)
-
350
(102)
700
(204)
-
cd/m2
fL
50
-
-
%
-5.0
-
-
Vdc
-5.0
-
-
Vdc
Luminance
Ef = 4.4 Vac
eb = 30.0 Vp-p
ec = 30.0 Vp-p
Du = 1/22
tp = 100 uS
Lmin/Lmax
Luminance Ratio
Ecco
Grid Cut-off Voltage
Ebco
Anode Cut-off Voltage
Ef = 4.4 Vac
Eb = 30.0 Vdc
Ef = 4.4 Vac
ec = 30.0 Vp-p
Du = 1/22
tp = 100 uS
* Drive Mode is Dynamic State
-2-
$3$&.
$3$&.
$3$&.
$3$&.