F:\\\271\346\270\361\312\351\\00 AC-DC Converter\\AC-DC

AC-DC Converter
DIP-Package
ALR-150 Series, 150Watt
FEATURES:
Universal AC input range
Short circuit, and over current protections
Board in-line type installation
High voltage isolation
Metal case
Model
ALR150-12
ALR150-15
ALR150-24
ALR150-48
Input voltage
(Vac)
85-265
Output voltage
(Vdc)
Output current
(A)
Output power
(W)
12
12.5
150
15
10
150
24
6.25
150
48
3.125
150
Notes: Above models are default to metal case and with heatsink.
ELECTRICAL
Input
Parameters
Symbols
Test Conditions / Comment
Min.
Typ.
Max.
Units
Input voltage
Vin
--
85
--
265
Vac
Input frequency
Fline
--
47
--
63
Hz
η
Full voltage, full load
--
85
--
%
Efficiency
Output
--
Vin=100-240Vac
--
1
--
%
Line regulation
Iout-line
Vin from 100Vac to 240Vac
--
0.2
--
%
Load regulation
Iout-load
20%-100% load
--
0.5
--
%
Ripple
--
--
--
--
120
mV
Turn-on delay time
--
--
--
1
--
S
Output voltage Accuracy
www.pairuigroup.com
Page: 1 / 4
V2.1.2 Date: 08/27/2014
AC-DC Converter
DIP-Package
ALR-150 Series, 150Watt
ELECTRICAL
Protection
Parameters
Symbols
Test Conditions / Comment
Over current
Continuous Automatic Recovery
Short circuit
Continuous Automatic Recovery
Min.
Typ.
Max.
Units
Environment
Storage
Ambient operating
temperature
Case temperature
Operating relative
humidity
MTBF
Tstorage
Humidity: 5% to 95% RH
-40
--
+105
℃
Ta
--
-25
--
+65
℃
Tc
--
--
--
+90
℃
Ha
Non condensing
10
--
90
%
TMTBF
--
--
--
200
kHrs
Dimension(LxWxH)
127x88.9x17.2mm
Weight
507g
Safety
Input-Output: 2500Vac≦1.5mA//1min
Isolation Voltage
Input-Case: 1500Vac≦1.5mA//1min
output-Case: 1500Vac≦1.5mA//1min
Notes: Unless otherwise specified, all the above parameters are measured at ambient temperature of 25
Vin = 100Vac to 240Vac.
www.pairuigroup.com
Page: 2 / 4
℃ and
V2.1.2 Date: 08/27/2014
AC-DC Converter
DIP-Package
ALR-150 Series, 150Watt
MECHANICAL
CONNECTION
LAYOUT
PIN #
SINGLE
1
NC
2
FG
3
AC(N)
4
AC(L)
5, 6
+Vo
7, 8
No Pin
9, 10
GND
11
+S
12
TRIM
13
-S
Note: Unit is mm(inch);
PIN#1,2,11,12,13 Φ=1.0mm,
others Φ=1.5mm
TEMPERATURE GRAPH
www.pairuigroup.com
Page: 3 / 4
V2.1.2 Date: 08/27/2014
AC-DC Converter
DIP-Package
ALR-150 Series, 150Watt
RECOMMENDED TEST AND APPLICATION CIRCUIT
EMC RECOMMENDED APPLICATION CIRCUIT
12VDC
15VDC
F1
T3.15A/250V
RT1
14D417K
NTC1
5D-14
R3
1MΩ/2W
L1
L=3-10mH,I=0.2-0.5A
CX1, CX2
0.15-3.3μF/300Vac
C3
1μF/50V
24VDC
C4
470uF/16V
120uF/25V
100uF/35V
Z1
P6KE6.8A
P6KE20A
P6KE33A
www.pairuigroup.com
Page: 4 / 4
V2.1.2 Date: 08/27/2014