LGU-60V - Pairui

Constant voltage LED Drivers
For outdoor use
LGU-60V Series, 60 Watt
FEATURES:
Constant voltage output
Universal AC input: 90-305VAC
Active power factor correction
Short circuit, over voltage, over current protections
Designed to worldwide safety standards for lighting
Cooling by free air convection
5 year warranty
Model
Nominal
Input voltage
(Vac)
LGU60-V12
LGU60-V18
LGU60-V24
100-277
LGU60-V36
Output voltage
(Vdc)
Output current
(mA)
Output power
(W)
Min.
Max.
12
0
5000
60
18
0
3170
60
24
0
2110
60
36
0
1810
60
Note: other output models may available on request.
ELECTRICAL
Input
Parameters
Symbols
Test Conditions / Comment
Min.
Typ.
Max.
Units
Input voltage
Vin
--
90
--
305
Vac
Input frequency
Fline
--
47
--
63
Hz
Full load, Vin = 110Vac
--
0.78
--
A
Full load, Vin = 220Vac
--
0.41
--
A
Cold start, Vin = 220Vac
--
--
60
A
Full load, Vin = 110Vac
--
0.99
--
A
Full load, Vin = 220Vac
--
0.96
--
A
η
Full load, Vin = 220Vac
87
--
91
%
Ileakage
Full load, Vin = 220Vac
--
--
0.75
A
--
--
--
5
--
%
Input current
Iin
Inrush current
Iinrush
Power factor
PF
Efficiency
Leakage current
Output voltage accuracy
www.pairuigroup.com
Page: 1 / 3
Date: 09/24/2014
Constant voltage LED Drivers
For outdoor use
LGU-60V Series, 60 Watt
ELECTRICAL
Output
Parameters
Symbols
Test Conditions / Comment
Min.
Typ.
Max.
Units
Line regulation
Iout-line
Vin from 90Vac to 305Vac
--
--
1
%
Load regulation
Iout-load
Vout from min. to max.
--
--
2
%
Turn-on delay time
Ton_delay
Cold start, power on
--
--
1.2
S
--
--
--
3
--
%
Ripple
Protection
Over voltage
110-150% rated output voltage
Over current
120-150% rated output current
Short circuit
In hiccup mode, it will recover automatically after fault condition is removed
Over temperature
Typ. 105
℃
Environment
Storage
Ambient operating
temperature
Operating relative
humidity
MTBF
Tstorage
Humidity: 10% RH to 95% RH
-40
--
+85
℃
Ta
Startup at rated voltage
-40
--
+70
℃
Ha
Non condensing
10
--
95
%
--
50
--
kHrs
TMTBF
Dimension(LxWxH)
Full load, 220Vac input,
℃
25
ambient temperature
211 x 67.5 x 37mm
Weight
760g
Safety / EMC
Safety standards
Withstand voltage
Isolation resistance
EMC
IEC/EN61347-1, IEC/EN61347-2-13, GB19510.1, GB19510.14, GB7000.1
I/P-O/P:3KVac I/P-FG:1.55KVac O/P-FG: 0.5KVac
(withstand voltage test before gas discharge tube installation)
℃
I/P-O/P, I/P-FG, O/P-FG: 100MΩ/500Vdc/25 /70%RH
IEC/EN55015, IEC/EN61547, IEC/EN61000-3-2, 3, IEC/EN61000-4-2, 3, 4, 5, 6, 8, 11,
GB17743, GB17625.1
℃ and
Notes: Unless otherwise specified, all the above parameters are measured at ambient temperature of 25
Vin = 100Vac to 277Vac.
www.pairuigroup.com
Page: 2 / 3
Date: 09/24/2014
Constant voltage LED Drivers
For outdoor use
LGU-60V Series, 60 Watt
MECHANICAL
Unit: mm
DERATING CURVE
www.pairuigroup.com
STATIC CHARACTERISTIC CURVE
Page: 3 / 3