LFU-100V

Constant voltage LED Drivers
For outdoor use
LFU-100V Series, 100Watt
FEATURES:
Constant voltage output
Active power factor correction
Short circuit, and over voltage protections
Designed to worldwide safety standards for lighting
Cooling by free air convection
Ⅱ
Class , no FG
100% burn-in test
2 year warranty
Model
Input voltage
(Vac)
Output voltage
(Vdc)
Output current
(A)
Output power
(W)
Min.
Max.
5
0
12
60
12
0
8.5
102
15
0
6.7
100.5
24
0
4.2
100.8
LFU100-V36
36
0
2.8
100.8
LFU100-V48
48
0
2.1
100.8
LFU100-V5
LFU100-V12
LFU100-V15
LFU100-V24
90-264
ELECTRICAL
Input
Parameters
Symbols
Test Conditions / Comment
Min.
Typ.
Max.
Units
Input voltage
Vin
--
90
--
264
Vac
Input frequency
Fline
--
47
--
63
Hz
Input current
Iin
Full load, Vin =230Vac
--
--
0.6
A
Power factor
PF
70%~100% load, Vin =230Vac
--
0.9
--
PF
Inrush current
Iinrush
Cold start, Vin =230Vac
--
35
--
A
η
Full voltage, full load
--
90
--
%
Ton_delay
Cold start, power on
--
1000
--
ms
Efficiency
Turn-on delay time
www.pairuigroup.com
Page: 1 / 4
Date: 07/17/2015
Constant voltage LED Drivers
For outdoor use
LFU-100V Series, 100Watt
ELECTRICAL
Output
Parameters
Test Conditions / Comment
Min.
Typ.
Max.
Units
LFU100-V5
0
--
12
A
LFU100-V12
0
--
8.5
A
LFU100-V15
0
--
6.7
A
LFU100-V24
0
--
4.2
A
LFU100-V36
0
--
2.8
A
LFU100-V48
0
--
2.1
A
LFU100-V5
--
5
--
V
LFU100-V12
--
12
--
V
LFU100-V15
--
15
--
V
LFU100-V24
--
24
--
V
LFU100-V36
--
36
--
V
LFU100-V48
--
48
--
V
--
--
--
±5
--
%
Line regulation
Vout-line
--
--
±1.0
--
%
Load regulation
Vout-load
--
--
±2.0
--
%
Vripple
---
--
5%Vo
--
mVp-p
--
Vin =115Vac, output load≥50%
--
--
20
%
Output current
Output voltage
Output voltage accuracy
Ripple
THD
Symbols
Iout
Vout
Protection
Overvoltage
Typical:110-150%
Short circuit
Hiccup mode, it will recover automatically after fault condition is removed
Environment
Storage
Ambient operating
temperature
Operating relative
humidity
MTBF
Dimension(LxWxH)
www.pairuigroup.com
Tstorage
Ta
Ha
TMTBF
Humidity: 5% RH to 95% RH
Startup at rated voltage
(required Derating)
Non condensing
Full load, 220Vac input, 25
ambient temperature
℃
-40
--
+80
℃
-25
--
+50
℃
10
--
95
%
400
--
--
kHrs
190.0 x 52.0 x 37.0mm
Page: 2 / 4
Date: 07/17/2015
Constant voltage LED Drivers
For outdoor use
LFU-100V Series, 100Watt
ELECTRICAL
Safety / EMC
Safety standards
EN61347-1, EN61347-2-13
EMC
EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 6, 8, 11, EN61547
Notes: 1.Unless otherwise specified, all the above parameters are measured at ambient temperature of 25
and Vin =230Vac, rated load.
2.Ripple & Noise are measured at 20MHZ of bandwidth by using a 12” twisted pair-wire terminated with a
0.1μF & 47μF parallel capacitor;
℃
MECHANICAL
Unit: mm
RECOMMEND INSTALLATION
BLOCK DIAGRAM
Unit: mm
www.pairuigroup.com
Page: 3 / 4
Date: 07/17/2015
Constant voltage LED Drivers
For outdoor use
LFU-100V Series, 100Watt
ELECTRICAL CURVE
DERATING CURVE
www.pairuigroup.com
STATIC CHARACTERISTIC CURVE
Page: 4 / 4
Date: 07/17/2015