Constant voltage LED Drivers For outdoor use LFU-100V Series, 100Watt FEATURES: Constant voltage output Active power factor correction Short circuit, and over voltage protections Designed to worldwide safety standards for lighting Cooling by free air convection Ⅱ Class , no FG 100% burn-in test 2 year warranty Model Input voltage (Vac) Output voltage (Vdc) Output current (A) Output power (W) Min. Max. 5 0 12 60 12 0 8.5 102 15 0 6.7 100.5 24 0 4.2 100.8 LFU100-V36 36 0 2.8 100.8 LFU100-V48 48 0 2.1 100.8 LFU100-V5 LFU100-V12 LFU100-V15 LFU100-V24 90-264 ELECTRICAL Input Parameters Symbols Test Conditions / Comment Min. Typ. Max. Units Input voltage Vin -- 90 -- 264 Vac Input frequency Fline -- 47 -- 63 Hz Input current Iin Full load, Vin =230Vac -- -- 0.6 A Power factor PF 70%~100% load, Vin =230Vac -- 0.9 -- PF Inrush current Iinrush Cold start, Vin =230Vac -- 35 -- A η Full voltage, full load -- 90 -- % Ton_delay Cold start, power on -- 1000 -- ms Efficiency Turn-on delay time www.pairuigroup.com Page: 1 / 4 Date: 07/17/2015 Constant voltage LED Drivers For outdoor use LFU-100V Series, 100Watt ELECTRICAL Output Parameters Test Conditions / Comment Min. Typ. Max. Units LFU100-V5 0 -- 12 A LFU100-V12 0 -- 8.5 A LFU100-V15 0 -- 6.7 A LFU100-V24 0 -- 4.2 A LFU100-V36 0 -- 2.8 A LFU100-V48 0 -- 2.1 A LFU100-V5 -- 5 -- V LFU100-V12 -- 12 -- V LFU100-V15 -- 15 -- V LFU100-V24 -- 24 -- V LFU100-V36 -- 36 -- V LFU100-V48 -- 48 -- V -- -- -- ±5 -- % Line regulation Vout-line -- -- ±1.0 -- % Load regulation Vout-load -- -- ±2.0 -- % Vripple --- -- 5%Vo -- mVp-p -- Vin =115Vac, output load≥50% -- -- 20 % Output current Output voltage Output voltage accuracy Ripple THD Symbols Iout Vout Protection Overvoltage Typical:110-150% Short circuit Hiccup mode, it will recover automatically after fault condition is removed Environment Storage Ambient operating temperature Operating relative humidity MTBF Dimension(LxWxH) www.pairuigroup.com Tstorage Ta Ha TMTBF Humidity: 5% RH to 95% RH Startup at rated voltage (required Derating) Non condensing Full load, 220Vac input, 25 ambient temperature ℃ -40 -- +80 ℃ -25 -- +50 ℃ 10 -- 95 % 400 -- -- kHrs 190.0 x 52.0 x 37.0mm Page: 2 / 4 Date: 07/17/2015 Constant voltage LED Drivers For outdoor use LFU-100V Series, 100Watt ELECTRICAL Safety / EMC Safety standards EN61347-1, EN61347-2-13 EMC EN55015, EN61000-3-2, EN61000-3-3, EN61000-4-2, 3, 4, 6, 8, 11, EN61547 Notes: 1.Unless otherwise specified, all the above parameters are measured at ambient temperature of 25 and Vin =230Vac, rated load. 2.Ripple & Noise are measured at 20MHZ of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor; ℃ MECHANICAL Unit: mm RECOMMEND INSTALLATION BLOCK DIAGRAM Unit: mm www.pairuigroup.com Page: 3 / 4 Date: 07/17/2015 Constant voltage LED Drivers For outdoor use LFU-100V Series, 100Watt ELECTRICAL CURVE DERATING CURVE www.pairuigroup.com STATIC CHARACTERISTIC CURVE Page: 4 / 4 Date: 07/17/2015