Constant current LED Drivers For indoor use LSU-16C Series, 16Watt FEATURES: Constant current output Cooling by free air convection Short circuit, over voltage protections IP30 rating Class Ⅱ, no FG 100% burn-in test 2 year warranty Model LSU16-C350 LSU16-C700 Input voltage (Vac) 90-264 Output current (Vdc) Output voltage (Vdc) Output power (W) Min. Max. 350 12 48 16.8 700 9 24 16.8 ELECTRICAL Input Parameters Symbols Test Conditions / Comment Input voltage Vin -- Input frequency Fline Input current Min. Typ. Max. Units 90 -- 264 Vac 120 -- 370 Vdc -- 47 -- 63 Hz Full load, Vin =115Vac -- 0.5 -- A Full load, Vin =230Vac -- 0.3 -- A Iin Inrush current Iinrush Cold start, Vin =230Vac -- 45 -- A Leakage current Ileakage Vin =240Vac -- 0.25 -- mA η Full voltage, full load -- 83 -- % LSU16-C350 322 350 378 mA LSU16-C700 644 700 756 mA LSU16-C350 12 -- 48 V LSU16-C700 9 -- 24 V -- -- ±8 -- % Efficiency Output Output current Iout Output voltage Vout Output current accuracy www.pairuigroup.com -- Page: 1 / 3 Date: 07/17/2015 Constant current LED Drivers For indoor use LSU-16C Series, 16Watt ELECTRICAL Output Parameters Symbols Test Conditions / Comment Min. Typ. Max. Units Line regulation Iout-line -- -- ±1 -- % Load regulation Iout-load -- -- ±3 -- % Full load, Vin =115Vac -- -- mS Full load, Vin =230Vac -- -- mS LSU16-C350 -- -- 300 mAp-p LSU16-C700 -- -- 250 mAp-p Turn-on, rise time Ripple -- Iripple 3000, 200 3000, 200 Protection Short circuit Hiccup mode, it will recover automatically after fault conditions is removed Environment Storage Ambient operating temperature Operating relative humidity MTBF Temperature coefficient Tstorage Humidity: 5% RH to 95% RH Startup at rated voltage Ta (required Derating) Ha TMTBF -40 -- +80 ℃ -30 -- +70 ℃ 10 -- 95 % -- 1100 -- kHrs -- ±0.2 -- % Non condensing Full load, 220Vac input, ℃ ambient temperature 0~50℃ 25 -- Dimension(LxWxH) 77 x 40 x 29mm Safety / EMC Safety standards Design refer to UL8750, CSA C22.2 NO.250.0-08, TUV EN61347-1 Withstand voltage I/P-O/P: 3.75KVAC EMC Design refer to EN55015,EN61000-3-2 Class A, EN61000-3-3, EN61000-4-2, 3, 4, 6, 8, 11, EN61547; Light industry level (surge 2KV), criteria A ℃ Notes: 1. Unless otherwise specified, all the above parameters are measured at ambient temperature of 25 and Vin = 230Vac, rated load; 2. Ripple & Noise are measured at 20MHZ of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor. www.pairuigroup.com Page: 2 / 3 Date: 07/17/2015 Constant current LED Drivers For indoor use LSU-16C Series, 16Watt MECHANICAL Unit: mm ELECTRICAL CURVE DERATING CURVE www.pairuigroup.com STATIC CHARACTERISTICS Page: 3 / 3 Date: 07/17/2015