LSU-16C - Pairui

Constant current LED Drivers
For indoor use
LSU-16C Series, 16Watt
FEATURES:
Constant current output
Cooling by free air convection
Short circuit, over voltage protections
IP30 rating
Class
Ⅱ, no FG
100% burn-in test
2 year warranty
Model
LSU16-C350
LSU16-C700
Input voltage
(Vac)
90-264
Output current
(Vdc)
Output voltage
(Vdc)
Output power
(W)
Min.
Max.
350
12
48
16.8
700
9
24
16.8
ELECTRICAL
Input
Parameters
Symbols
Test Conditions / Comment
Input voltage
Vin
--
Input frequency
Fline
Input current
Min.
Typ.
Max.
Units
90
--
264
Vac
120
--
370
Vdc
--
47
--
63
Hz
Full load, Vin =115Vac
--
0.5
--
A
Full load, Vin =230Vac
--
0.3
--
A
Iin
Inrush current
Iinrush
Cold start, Vin =230Vac
--
45
--
A
Leakage current
Ileakage
Vin =240Vac
--
0.25
--
mA
η
Full voltage, full load
--
83
--
%
LSU16-C350
322
350
378
mA
LSU16-C700
644
700
756
mA
LSU16-C350
12
--
48
V
LSU16-C700
9
--
24
V
--
--
±8
--
%
Efficiency
Output
Output current
Iout
Output voltage
Vout
Output current accuracy
www.pairuigroup.com
--
Page: 1 / 3
Date: 07/17/2015
Constant current LED Drivers
For indoor use
LSU-16C Series, 16Watt
ELECTRICAL
Output
Parameters
Symbols
Test Conditions / Comment
Min.
Typ.
Max.
Units
Line regulation
Iout-line
--
--
±1
--
%
Load regulation
Iout-load
--
--
±3
--
%
Full load, Vin =115Vac
--
--
mS
Full load, Vin =230Vac
--
--
mS
LSU16-C350
--
--
300
mAp-p
LSU16-C700
--
--
250
mAp-p
Turn-on, rise time
Ripple
--
Iripple
3000,
200
3000,
200
Protection
Short circuit
Hiccup mode, it will recover automatically after fault conditions is removed
Environment
Storage
Ambient operating
temperature
Operating relative humidity
MTBF
Temperature coefficient
Tstorage
Humidity: 5% RH to 95% RH
Startup at rated voltage
Ta
(required Derating)
Ha
TMTBF
-40
--
+80
℃
-30
--
+70
℃
10
--
95
%
--
1100
--
kHrs
--
±0.2
--
%
Non condensing
Full load, 220Vac input,
℃ ambient temperature
0~50℃
25
--
Dimension(LxWxH)
77 x 40 x 29mm
Safety / EMC
Safety standards
Design refer to UL8750, CSA C22.2 NO.250.0-08, TUV EN61347-1
Withstand voltage
I/P-O/P: 3.75KVAC
EMC
Design refer to EN55015,EN61000-3-2 Class A, EN61000-3-3, EN61000-4-2, 3, 4, 6, 8, 11,
EN61547; Light industry level (surge 2KV), criteria A
℃
Notes: 1. Unless otherwise specified, all the above parameters are measured at ambient temperature of 25 and
Vin = 230Vac, rated load;
2. Ripple & Noise are measured at 20MHZ of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μF
& 47μF parallel capacitor.
www.pairuigroup.com
Page: 2 / 3
Date: 07/17/2015
Constant current LED Drivers
For indoor use
LSU-16C Series, 16Watt
MECHANICAL
Unit: mm
ELECTRICAL CURVE
DERATING CURVE
www.pairuigroup.com
STATIC CHARACTERISTICS
Page: 3 / 3
Date: 07/17/2015