AC-DC Converter DIP-Package ADR-5 Series, 5Watt FEATURES: Universal AC input range Typical Efficiency up to 80% Short circuit, over current and over voltage protections Board in-line type installation High voltage isolation 3000Vac 100% burn-in test 3 year warranty Output voltage (Vdc) Output current (mA) Efficiency Typ. ADR5-3 3.3 1500 74% ADR5-5 ADR5-9 ADR5-12 5 1000 80% 9 550 82% 12 410 82% ADR5-15 15 330 84% ADR5-24 24 210 83% Model Input voltage (Vac) 85-264 ELECTRICAL Input Parameters Symbols Test Conditions / Comment Min. Typ. Max. Units Input voltage Vin -- 85 -- 264 Vac Input frequency Fline -- 47 -- 63 Hz Full load, Vin =115Vac -- 200 -- mA Full load, Vin =230Vac -- 100 -- mA Iinrush Cold start, Vin =230Vac -- 40 -- A η Full voltage, full load -- 80 -- % Input current Inrush current Efficiency Iin Output Output voltage accuracy Line regulation www.pairuigroup.com -- Vin=100-240Vac -- 1 -- % Vout-line Vin from 100Vac to 240Vac -- 2 -- % Page: 1/4 Date: 07/30/2015 *Subject to change without notice AC-DC Converter DIP-Package ADR-5 Series, 5Watt ELECTRICAL Output Parameters Symbols Test Conditions / Comment Min. Typ. Max. Units Load regulation Vout-load 20%-100% load -- 3 -- % Set-up rise time -- Full load, Vin =230Vac -- 25 -- Switching frequency -- -- 60 -- 100 KHz Full load, Vin =115Vac -- 8 -- ms Full load, Vin =230Vac -- 40 -- ms -- -- 60 -- mV -40 -- +85 ℃ -25 -- +70 ℃ 10 -- 90 % 450 -- -- kHrs Hold-up time Ripple ms -- Vripple Protection Overload Typ.125-190% Overvoltage Typ.125-190% Environment Storage Ambient operating temperature Operating relative humidity MTBF Tstorage Humidity: 5% RH to 95% RH Startup at rated voltage Ta (Please refer to derating curve) Ha Non condensing TMTBF Full load, 230Vac input, 25 ℃ ambient temperature Dimension(LxWxH) 25.4 x 25.4 x 15.24mm Safety Safety standards EN609501-1, EN60950-1 Withstand voltage I/P-O/P: 3KVac Insulation Resistance I/P-O/P: 100M Ohms/500VDC/25 /70%RH EMI / RFI conducted EN55022, Level B conducted & radiated > ℃ ℃ and Notes: Unless otherwise specified, all the above parameters are measured at ambient temperature of 25 input nominal voltage. www.pairuigroup.com Page: 2/4 Date: 07/30/2015 *Subject to change without notice AC-DC Converter DIP-Package ADR-5 Series, 5Watt MECHANICAL CONNECTION PIN # SINGLE 1 AC(N) 2 AC(L) 3 NC 4 -Vo 5 +Vo Note: Unit is mm(inch). ELECTRICAL CURVE DERATING CURVE www.pairuigroup.com STATIC CHARACTERISTIC CURVE Page: 3/4 Date: 07/30/2015 *Subject to change without notice AC-DC Converter DIP-Package ADR-5 Series, 5Watt NOTE RECOMMENDED TEST AND APPLICATION CIRCUIT EMC RECOMMENDED APPLICATION CIRCUIT 3.3VDC 5VDC 9VDC 12VDC F1 T1A/250V RT1 7D471K R1, R2 2Ω/3W R3 1MΩ/2W L1 L=3-10mH, I=0.2-0.5A CX1, CX2 0.15-1μF/300Vac CY1, CY2 102K/400Vac C3 1μF/50V 15VDC 24VDC C4 470uF/16V 470uF/16V 150uF/25V 120uF/25V 120uF/25V 100uF/35V Z1 P6KE6.8A P6KE6.8A P6KE16A P6KE16A P6KE20A P6KE33A www.pairuigroup.com Page: 4/4 Date: 07/30/2015 *Subject to change without notice